Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 93(11): 113512, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36461481

RESUMO

Dedicated nuclear diagnostics have been designed, developed, and built within EUROFUSION enhancement programs in the last ten years for installation at the Joint European Torus and capable of operation in high power Deuterium-Tritium (DT) plasmas. The recent DT Experiment campaign, called DTE2, has been successfully carried out in the second half of 2021 and provides a unique opportunity to evaluate the performance of the new nuclear diagnostics and for an understanding of their behavior in the record high 14 MeV neutron yields (up to 4.7 × 1018 n/s) and total number of neutrons (up to 2 × 1019 n) achieved on a tokamak. In this work, we will focus on the 14 MeV high resolution neutron spectrometers based on artificial diamonds which, for the first time, have extensively been used to measure 14 MeV DT neutron spectra with unprecedented energy resolution (Full Width at Half Maximum of ≈1% at 14 MeV). The work will describe their long-term stability and operation over the DTE2 campaign as well as their performance as neutron spectrometers in terms of achieved energy resolution and high rate capability. This important experience will be used to outline the concept of a spectroscopic neutron camera for the SPARC tokamak. The proposed neutron camera will be the first one to feature the dual capability to measure (i) the 2.5 and 14 MeV neutron emissivity profile via the conventional neutron detectors based on liquid or plastics scintillators and (ii) the 14 MeV neutron spectral emission via the use of high-resolution diamond-based spectrometers. The new opportunities opened by the spectroscopic neutron camera to measure plasma parameters will be discussed.

2.
Rev Sci Instrum ; 93(9): 093525, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36182521

RESUMO

The most performant deuterium-tritium (DT) plasma discharges realized by the Joint European Torus (JET) tokamak in the recent DT campaign have produced neutron yields on the order of 1018 n/s. At such high neutron yields, gamma-ray spectroscopy measurements with scintillators are challenging as events from the neutron-induced background often dominate over the signal, leading to a significant fraction of pileup events and instability of the photodetector gain along with the consequent degradation of the reconstructed spectrum. Here, we describe the solutions adopted for the tangential lanthanum bromide spectrometer installed at JET. A data acquisition system with free streaming mode digitization capabilities for the entire duration of the discharge has been used to solve dead-time related issues and a data reconstruction code with pileup recovery and photodetector gain drift restoration has been implemented for off-line analysis of the data. This work focuses on the acquired data storage and parsing, with a detailed explanation of the pileup recovery and gain drift restoration algorithms.

3.
Rev Sci Instrum ; 92(5): 053529, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243238

RESUMO

The Joint European Torus (JET) gamma-ray camera has been recently upgraded with the installation of new gamma-ray detectors, based on LaBr3(Ce) scintillation crystals, which add spectroscopic capability to the existing system allowing measurements with good energy resolution (5% at 0.622 MeV), a dynamic range from hundreds of keV up to about 30 MeV, and high counting rate capabilities of MCps. First gamma-ray measurements during the C38 campaign of the JET have been successfully carried out, in particular, in D-3He plasmas from three-ion ion cyclotron resonance heating experiments, where the detection of 16.4 MeV γ-rays from D + 3He → γ + 5Li reactions with the gamma-ray camera upgrade allowed determining the spatial profile of alpha particles born in D + 3He fusion reactions.

4.
Rev Sci Instrum ; 89(10): 10I126, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399810

RESUMO

A set of gamma ray spectrometers has been designed for ITER within the Radial Gamma Ray Spectrometer (RGRS) project. The aim of this project is designing a system, integrated with the ITER radial neutron camera, which is able to measure the gamma-rays emitted from the plasma with a good energy resolution (about 1.5% at 4.44 MeV) and at high counting rates (in excess of 1 MHz). The RGRS will be able to operate both in the D phase and in the full-power DT phase and will measure gamma rays from (i) reactions between fast ions, such as α particles, and light impurities and (ii) bremsstrahlung emission generated by runaway electron interactions with both plasma bulk and tokamak walls. The RGRS detectors are arranged in nine lines of sights (able to cover a radial region with r < a/3), each featuring a large LaBr3 scintillator crystal. Due to the high neutron flux and magnetic field, several solutions have been adopted to guarantee a good signal to background ratio and MHz counting rate capabilities. The RGRS is capable to combine space and energy distribution measurements of α particles and runaway electrons, which will help the study of the fast particle physics in a burning plasma.

5.
Rep Prog Phys ; 79(9): 094301, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27502571

RESUMO

Neutron scattering techniques are attracting an increasing interest from scientists in various research fields, ranging from physics and chemistry to biology and archaeometry. The success of these neutron scattering applications is stimulated by the development of higher performance instrumentation. The development of new techniques and concepts, including radiative capture based neutron detection, is therefore a key issue to be addressed. Radiative capture based neutron detectors utilize the emission of prompt gamma rays after neutron absorption in a suitable isotope and the detection of those gammas by a photon counter. They can be used as simple counters in the thermal region and (simultaneously) as energy selector and counters for neutrons in the eV energy region. Several years of extensive development have made eV neutron spectrometers operating in the so-called resonance detector spectrometer (RDS) configuration outperform their conventional counterparts. In fact, the VESUVIO spectrometer, a flagship instrument at ISIS serving a continuous user programme for eV inelastic neutron spectroscopy measurements, is operating in the RDS configuration since 2007. In this review, we discuss the physical mechanism underlying the RDS configuration and the development of associated instrumentation. A few successful neutron scattering experiments that utilize the radiative capture counting techniques will be presented together with the potential of this technique for thermal neutron diffraction measurements. We also outline possible improvements and future perspectives for radiative capture based neutron detectors in neutron scattering application at pulsed neutron sources.

6.
Rev Sci Instrum ; 85(4): 043506, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24784606

RESUMO

First simultaneous measurements of deuterium-deuterium (DD) and deuterium-tritium neutrons from deuterium plasmas using a Single crystal Diamond Detector are presented in this paper. The measurements were performed at JET with a dedicated electronic chain that combined high count rate capabilities and high energy resolution. The deposited energy spectrum from DD neutrons was successfully reproduced by means of Monte Carlo calculations of the detector response function and simulations of neutron emission from the plasma, including background contributions. The reported results are of relevance for the development of compact neutron detectors with spectroscopy capabilities for installation in camera systems of present and future high power fusion experiments.

7.
Rev Sci Instrum ; 81(10): 10D321, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21058454

RESUMO

A new high efficiency, high resolution, fast γ-ray spectrometer was recently installed at the JET tokamak. The spectrometer is based on a LaBr3(Ce) scintillator coupled to a photomultiplier tube. A digital data acquisition system is used to allow spectrometry with event rates in excess of 1 MHz expected in future JET DT plasmas. However, at the lower rates typical of present day experiments, digitization can degrade the energy resolution of the system, depending on the algorithms used for extracting pulse height information from the digitized pulses. In this paper, the digital and analog spectrometry methods were compared for different experimental conditions. An algorithm based on pulse shape fitting was developed, providing energy resolution equivalent to the traditional analog spectrometry method.

8.
Phys Rev E Stat Nonlin Soft Matter Phys ; 73(4 Pt 2): 046402, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16711934

RESUMO

We present experimental results on fast-electron energy deposition into solid targets in ultrahigh intensity laser-matter interaction. X-ray K alpha emission spectroscopy with absolute photon counting served to diagnose fast-electron propagation in multilayered targets. Target heating was measured from ionization-shifted K alpha emission. Data show a 200 microm fast-electron range in solid Al. The relative intensities of spectrally shifted Al K alpha lines imply a mean temperature of a few tens of eV up to a 100 microm depth. Experimental results suggest refluxing of the electron beam at target rear side. They were compared with the predictions of both a collisional Monte Carlo and a collisional-electromagnetic, particle-fluid transport code. The validity of the code modeling of heating in such highly transient conditions is discussed.

9.
Phys Rev E Stat Nonlin Soft Matter Phys ; 69(6 Pt 2): 066414, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15244752

RESUMO

Electron transport within solid targets, irradiated by a high-intensity short-pulse laser, has been measured by imaging K(alpha) radiation from high- Z layers (Cu, Ti) buried in low- Z (CH, Al) foils. Although the laser spot is approximately 10 microm [full width at half maximum (FWHM)], the electron beam spreads to > or =70 microm FWHM within <20 microm of penetration into an Al target then, at depths >100 microm, diverges with a 40 degree spreading angle. Monte Carlo and analytic models are compared to our data. We find that a Monte Carlo model with a heuristic model for the electron injection gives a reasonable fit with our data.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...