Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Food Res Int ; 160: 111692, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36076397

RESUMO

For the first time, structural analogues to bisphenol A were investigated in infant formulas marketed in Brazil. A fast and high throughput UPLC-MS/MS method was established for simultaneous analysis of bisphenol A, B, E, F, and S in complex infant formula matrices. The influence of mobile phase composition on electrospray ionization response in negative mode was studied to improve the detectability of the method. As also, the main sample preparation variables that could affect the extraction and cleanup were screened by the Plackett-Burman design. The method performance characteristics were adequate, including reliable limits of detection (5-10 µg kg-1) and quantification (10-20 µg kg-1) with suitable recoveries (84.2-108.9 %) and precision (≤18 %). Sixty-one infant formulas were analyzed, and 36 % of total samples contained at least one bisphenol analogue, whose levels ranged between 10.9 and 198.9 µg kg-1. Based on a deterministic approach, the estimated daily intakes for babies up to 6 months old, fed exclusively with infant formula, were below the temporary tolerable daily intake of 4 µg kg-1 body weight set for bisphenol A by the European Food Safety Authority.


Assuntos
Fórmulas Infantis , Espectrometria de Massas em Tandem , Compostos Benzidrílicos , Brasil , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida , Exposição Dietética , Humanos , Lactente , Fórmulas Infantis/química , Fenóis
2.
Food Chem ; 362: 129902, 2021 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-34175690

RESUMO

This paper describes a fast, sensitive, environment-friendly method for the determination of 19 primary aromatic amines (PAAs) in cooking utensils by capillary zone electrophoresis coupled with tandem mass spectrometry. The best electrophoretic separation of PAAs was obtained in 0.1 mol l-1 formic acid (pH 2.4) as the background electrolyte, fused silica capillary (67 cm) with a run time below 6 min. The proposed method presented a linear calibration with correlation coefficients higher than 0.99 and reproducibility in a range of 1-25%. Limits of detection were in the range of 0.2-1.3 µg kg-1 and recoveries were in a range of 85-120% for all the PAAs. The validated method was employed to determine PAAs on 36 samples of cooking utensils using acetic simulant. The results showed that 4,4'-diaminodiphenylmethane and aniline being the most frequently found PAAs in these samples and 28% of cooking utensils were not compliant.


Assuntos
Aminas/análise , Utensílios de Alimentação e Culinária , Eletroforese Capilar , Espectrometria de Massas em Tandem , Compostos de Anilina/análise , Calibragem , Eletroforese Capilar/métodos , Reprodutibilidade dos Testes
3.
J Chromatogr A ; 1602: 217-227, 2019 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-31133424

RESUMO

The aim of this paper is to develop and validate a methodology with potential for routine analysis that allows a fast and easy quantification of 19 primary aromatic amines (PAAs) in acid simulant (3% (w/v) acetic acid aqueous) in food contact materials (FCM). The main reason for studying these amines was the fact that some of them have a carcinogenic factor according to toxicological studies. To validate the method, the parameters linearity, limit of detection (LOD) and limit of quantification (LOQ), precision and accuracy using an UPLC-MS/MS were evaluated. This study also analyzed 36 samples of kitchenware obtained from retail markets: 16 were made of polyamide (PA), one was made of polypropylene (PP) and 19 were made of silicone. The origins of samples were Brazil, China and Turkey. Eleven samples had levels of 4,4´-diaminodiphenylmethane higher than permitted by legislation and five samples showed values of aniline above the limit. Considering the Mood test for polyamides, there were significant differences between the samples from Brazil and China, as well as between the colors in the silicone samples. Regarding the polyamides, the Chinese samples showed higher amounts of PAAs than the Brazilian ones, being above that allowed by legislation. Three Chinese silicone samples presented values above the legislation limit. These were all from the same importer.


Assuntos
Aminas/análise , Técnicas de Química Analítica/métodos , Cromatografia Líquida , Utensílios de Alimentação e Culinária/normas , Contaminação de Alimentos/análise , Espectrometria de Massas em Tandem , Compostos de Anilina/análise , Brasil , Carcinógenos/análise , China , Contaminação de Alimentos/prevenção & controle , Limite de Detecção , Nylons/química , Polipropilenos/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA