Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Dent. press endod ; 11(3): 24-30, Sept-Dec.2021. Tab, Ilus
Artigo em Inglês | LILACS | ID: biblio-1378771

RESUMO

Objetivo: Avaliar a molhabilidade do cimento AH Plus em contato com a dentina radicular após diferentes protocolos quelantes envolvendo ácido etidrônico (HEBP) e o EDTA. Métodos: Cinquenta e seis fatias de dentina radicular foram utilizadas e irrigadas com 5.25% de hipoclorito de sódio (NaOCl) ou com uma mistura de 5.25%NaOCl/18%HEBP para simular a irrigação durante o preparo químico-mecânico. As amostras irrigadas com NaOCl foram divididas em 5 grupos, de acordo com o agente quelante: G1- água destilada (AD); G2-17%EDTA; G3-17%EDTA+2.5%NaOCl; G4-18%HEBP; e G5-18%HEBP+2.5%NaOCl. As amostras irrigadas com a mistura de NaOCl/HEBP foram dividias em 2 grupos: G6-AD; G7-NaOCl/HEBP+2.5%- NaOCl. Todos os protocolos receberam irrigação de AD entre as substâncias irrigadoras e como lavagem final. O goniômetro Rame-Hart foi utilizado para mesurar o ângulo de contato entre a superfície da dentina radicular e o cimento. O teste estatístico Kruskal-Wallis e Dunn foram aplicados (p<0.05). Resultados: Os grupos onde a smear layer foi removida apresentaram menor ângulo de contato (p<0.05), com exceção do G7. O G6 apresentou o menor ângulo de contato do AH Plus, entretanto, a irrigação final com NaOCl (G7) aumentou significativamente o ângulo de contato. G2 e G4 apresentaram comportamento similar e a irrigação final com NaOCL (G3 e G4) não modificou a molhabilidade da dentina. Conclusão: O tratamento da dentina radicular com a mistura NaOCl/HEBP, quando usada como irrigante, conferiu boa molhabilidade desta superfície ao cimento AH Plus(AU).


Evaluate the wettability of AH Plus in contact with root dentin after different chelating protocols involving etidronic acid (HEBP) and EDTA. Material and Methods: Fifty six human polished root dentin slices were used. They were irrigated with 5.25% sodium hypochlorite (NaOCl) or a mixture of 5.25%NaOCl/18%HEBP to simulate irrigation during chemomechanical preparation. The specimens irrigated with NaOCl were divided into 5 groups regarding chelating agents: G1-destiled water (DW); G2- 17%EDTA; G3-17%EDTA+2.5%NaOCl; G4-18%HEBP; and G5-18%HEBP+2.5%NaOCl. The specimens irrigated with the mixture NaOCl/HEBP were divided into 2 groups: G6-DW; G7-NaOCl/HEBP+2.5%NaOCl. All protocols received irrigation with DW between irrigants and as final rinse. Rame-Hart goniometer was used to measure the contact angle between the dentin surfaces and the sealer. Kruskal-Wallis and Dunn tests were applied (p<0.05). Results: Groups in which the smear layer was removed showed a lower contact angle (p<0.05), except for G7. The G6 showed the lowest contact angle of AH Plus, but the NaOCl final irrigation (G7) increased the angle. G2 and G4 have similar behaviour and final irrigation with NaOCl (G3 and G5) did not change wettability when these chelators were used. Conclusions: The mixture NaOCl/HEBP showed good effect on the wettability of sealer on to the root canal dentine, when used as main irrigant (AU).


Assuntos
Humanos , Irrigantes do Canal Radicular , Molhabilidade , Cavidade Pulpar , Dentina , Resinas Epóxi , Hipoclorito de Sódio , Quelantes , Guias como Assunto
2.
Open Dent J ; 12: 189-201, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29541265

RESUMO

Advances in endodontics have enabled the evolution of file manufacturing processes, improving performance beyond that of conventional files. In the present study, systems manufactured using state of the art methods and possessing special properties related to NiTi alloys (i.e., CM-Wire, M-Wire and R-Phase) were selected. The aim of this review was to provide a detailed analysis of the literature about the relationship between recently introduced NiTi files with different movement kinematics and shaping ability, apical extrusion of debris and dentin defects in root canal preparations. From March 2016 to January 2017, electronic searches were conducted in the PubMed and SCOPUS databases for articles published since January 2010. In vitro studies performed on extracted human teeth and published in English were considered for this review. Based on the inclusion criteria, 71 papers were selected for the analysis of full-text copies. Specific analysis was performed on 45 articles describing the effects of reciprocating, continuous and adaptive movements on the WaveOne Gold, Reciproc, HyFlex CM and Twisted File Adaptive systems. A wide range of testing conditions and methodologies have been used to compare the systems. Due the controversies among the results, the characteristics of the files used, such as their design and alloys, appear to be inconsistent to determine the best approach.

3.
J Endod ; 42(6): 886-9, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27071975

RESUMO

INTRODUCTION: Radiation therapy (RT) of malignant tumors in the head and neck area may have damaging effects on surrounding tissues. The aim of this investigation was to evaluate the long-term effects of ionizing radiation on pulp vitality by measuring pulp oxygenation levels (%SpO2) in patients with history of RT of intraoral and oropharyngeal tumors 4-6 years after treatment. METHODS: In an experimental group RT (n = 90, history of RT) and a control group CON (n = 90, no history of RT), pulp vitality was assessed by measuring %SpO2 by using pulse oximetry and pulp sensitivity by cold thermal testing. All anterior teeth without history of endodontic therapy of the participants in group RT were measured (n = 693), regardless of the quadrant and the irradiated area. An equal number of anterior teeth were tested in group CON. RESULTS: There was no significant difference between the %SpO2 levels in group RT (92.7%; standard deviation, ± 1.83) and group CON (92.6%; standard deviation, ± 1.80). All teeth in RT and CON groups showed a positive response to the thermal test. All tested teeth were considered vital. CONCLUSIONS: Pulp %SpO2 was found to be within normal limits 4-6 years after RT. This suggests that RT may not have a long-term influence on pulp vitality, and reported short-term changes in pulpal microcirculation because of RT may be temporary.


Assuntos
Teste da Polpa Dentária/métodos , Polpa Dentária/efeitos da radiação , Neoplasias de Cabeça e Pescoço/radioterapia , Oximetria/métodos , Radioterapia/efeitos adversos , Adulto , Idoso , Polpa Dentária/irrigação sanguínea , Feminino , Humanos , Incisivo/efeitos da radiação , Masculino , Microcirculação/efeitos da radiação , Pessoa de Meia-Idade , Neoplasias Orofaríngeas/radioterapia , Oxigênio/análise , Oxigênio/sangue , Radiação Ionizante , Fluxo Sanguíneo Regional/efeitos da radiação
4.
Am J Dent ; 28(1): 40-4, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25864241

RESUMO

PURPOSE: To present an overview of clinical evidence of strontium acetate and arginine-based toothpastes, in order to determine which of these substances was the most effective to relieve dentin hypersensitivity (DH). METHODS: An electronic search was performed in PubMed, EMBASE, The Cochrane Library, LILACS, Web of Science and Open Grey databases. The search strategy included MeSH terms, synonyms and keywords with no language or date restriction. Randomized controlled clinical trial studies that compared the effectiveness of arginine/calcium carbonate and strontium acetate toothpaste were included. The risk of bias in the included studies was assessed and classified through the Cochrane Collaboration's common scheme for bias. Data were subgrouped and heterogeneity was tested via comprehensive meta-analysis. RESULTS: A total of 3,883 potentially relevant studies were identified. After title and abstract examination, only six studies fulfilled the eligibility criteria and were classified as having a "low risk of bias". The majority of studies found better results for arginine/calcium carbonate in comparison with strontium acetate in alleviating DH. Only one study reported superior efficacy of strontium acetate, and only for tactile stimuli, after 8 weeks of home use. The arginine/calcium carbonate-based toothpaste provided a higher level of efficacy in terms of DH relief than the strontium-based toothpaste.


Assuntos
Acetatos/uso terapêutico , Arginina/uso terapêutico , Carbonato de Cálcio/uso terapêutico , Dessensibilizantes Dentinários/uso terapêutico , Sensibilidade da Dentina/terapia , Fluoretos/uso terapêutico , Fosfatos/uso terapêutico , Estrôncio/uso terapêutico , Cremes Dentais/uso terapêutico , Viés , Humanos , Projetos de Pesquisa , Resultado do Tratamento
5.
Braz Dent J ; 24(2): 117-20, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23780365

RESUMO

The aim of this study was to assess cyclic fatigue resistance in rotary nickel-titanium instruments after simulated clinical use in curved root canals (40-degree, 5-mm radius curve). Thirty-six RaCe rotary NiTi files, size #5, taper 0.04, were divided into 3 groups: Groups A, B and C with one, three and five cycles of use, respectively. Time to failure was recorded with a stopwatch in seconds and subsequently converted to number of cycles to fracture. The data were analyzed statistically by ANOVA and Tukey's test (α=0.05). Five sets of clinically used files (group C) reached significantly lower cycle-numbers before fracture (mean=197.5 cycles) when compared with one set of clinically used files (mean=309.2) and three sets (mean=287.5). Results showed that the number of simulated clinical uses of RaCe instruments for shaping curved canals affects adversely the fatigue resistance of these instruments after five uses.


Assuntos
Ligas Dentárias/química , Cavidade Pulpar/anatomia & histologia , Níquel/química , Preparo de Canal Radicular/instrumentação , Titânio/química , Desenho de Equipamento , Falha de Equipamento , Humanos , Modelos Anatômicos , Rotação , Estresse Mecânico , Fatores de Tempo
6.
Braz. dent. j ; 24(2): 117-120, Mar-Apr/2013. graf
Artigo em Inglês | LILACS | ID: lil-675666

RESUMO

The aim of this study was to assess cyclic fatigue resistance in rotary nickel-titanium instruments after simulated clinical use in curved root canals (40-degree, 5-mm radius curve). Thirty-six RaCe rotary NiTi files, size #5, taper 0.04, were divided into 3 groups: Groups A, B and C with one, three and five cycles of use, respectively. Time to failure was recorded with a stopwatch in seconds and subsequently converted to number of cycles to fracture. The data were analyzed statistically by ANOVA and Tukey's test (α=0.05). Five sets of clinically used files (group C) reached significantly lower cycle-numbers before fracture (mean=197.5 cycles) when compared with one set of clinically used files (mean=309.2) and three sets (mean=287.5). Results showed that the number of simulated clinical uses of RaCe instruments for shaping curved canals affects adversely the fatigue resistance of these instruments after five uses.


Resumo O objetivo deste estudo foi avaliar a resistência à fadiga cíclica de instrumentos rotatórios de níquel-titânio após simulação de uso clinico em canais curvos (curvatura de 40° e raio de 5 mm). Trinta e seis instrumentos, calibre n° 25 conicidade 0,04, foram divididos em três grupos: o Grupo A com um ciclo de uso; Grupo B, três ciclos de uso e grupo C, cinco ciclos de uso. Um cronômetro digital aferiu em segundos o tempo até a fratura do instrumento que, posteriormente, foi convertido em número de ciclos para fratura. Os dados foram analisados por ANOVA e teste de Tukey (p<0,05). O grupo que utilizou o instrumento por cinco ciclos (grupo C) atingiu significativamente menores números de ciclos antes da fratura (média = 197,5 ciclos) quando comparado com os instrumentos utilizados em um ciclo (média = 309,2) e três ciclos (média = 287,5). Os resultados mostraram que o número de uso de instrumentos RaCe para modelar canais curvos afeta negativamente a resistência à fadiga cíclica dos instrumentos após cinco usos. .


Assuntos
Humanos , Ligas Dentárias/química , Cavidade Pulpar/anatomia & histologia , Níquel/química , Preparo de Canal Radicular/instrumentação , Titânio/química , Desenho de Equipamento , Falha de Equipamento , Modelos Anatômicos , Rotação , Estresse Mecânico , Fatores de Tempo
7.
J Endod ; 37(9): 1197-200, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21846533

RESUMO

INTRODUCTION: The aim of this study was to evaluate pulp oxygenation levels (%SpO(2)) in patients with malignant intraoral and oropharyngeal tumors treated by radiotherapy (RT). METHODS: Pulp oxygenation levels were measured by pulse oximetry. Twenty patients were selected, and two teeth of each participant (n = 40) were analyzed, regardless of the quadrant and the area irradiated, at four different time points: TP1, before RT; TP2, at the beginning of RT with radiation doses between 30 and 35 Gy; TP3, at the end of RT with radiation doses between 60 and 70 Gy; and TP4, 4 to 5 months after the beginning of cancer treatment. RESULTS: Mean %SpO(2) at the different time points were 93% (TP1), 83% (TP2), 77% (TP3), and 85% (TP4). The Student's t test showed statistically significant differences between TP1 and TP2 (P < .01), TP3 (P < .01), and TP4 (P < .01). TP3 was also statistically significantly different when compared with TP2 (P < .01) and TP4 (P < .01). No statistically significant difference could be observed between TP2 and TP4. CONCLUSIONS: Because the mean %SpO(2) before RT was greater than during and after therapy and values obtained 4 to 5 months after the beginning of RT were close to the initiation of RT, pulp tissue may be able to regain normal blood flow after RT. If the changes in the microcirculation of the dental pulp were indeed transitory, preventive endodontic treatment or extraction in patients who are currently undergoing or recently received RT and who show negative signs of pulp sensitivity may not be necessary for pulpal reasons.


Assuntos
Assistência Odontológica para Doentes Crônicos/estatística & dados numéricos , Polpa Dentária/irrigação sanguínea , Neoplasias Orofaríngeas/radioterapia , Adulto , Teste da Polpa Dentária , Feminino , Humanos , Masculino , Microcirculação/efeitos da radiação , Pessoa de Meia-Idade , Oximetria , Oxigênio/sangue , Dente não Vital/prevenção & controle , Procedimentos Desnecessários
8.
Dent. press endod ; 1(2): 89-93, 2011. ilus
Artigo em Português | LILACS | ID: lil-685802

RESUMO

Objetivo: demonstrar para o clínico geral a importância do uso do lençol de borracha durante o tratamento endodôntico e descrever o monitoramento empregado no caso de um paciente que ingeriu acidentalmente uma lima rotatória Protaper® S1 (Dentsply Maillefer, Suíça) durante o preparo dos canais. Relato do caso: um paciente de 28 anos de idade foi submetido ao tratamento endodôntico sem isolamento absoluto e, durante o preparo químico cirúrgico do canal, engoliu uma lima Protaper® S1. Foi acompanhado até o hospital onde, a princípio, foi realizada uma endoscopia gastro intestinal alta e uma tomografia computadorizada. Permaneceu assintomático após essas duas intervenções iniciais,sendo monitorado durante quatro dias, através de radiografias de tórax e abdômen, até a eliminação desse corpo estranho. Conclusão: os clínicos gerais que fazem Endodontia devem estar atentos aos riscos envolvidos na deglutição e/ou aspiração acidental de corpos estranhos durante o tratamento endodôntico, bem como saber evitar esse tipo de problema adotando uma medida simples: a utilização do lençol de borracha


Assuntos
Humanos , Corpos Estranhos/complicações , Deglutição , Diques de Borracha , Endodontia/instrumentação , Preparo de Canal Radicular/instrumentação
9.
J Endod ; 36(7): 1183-6, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20630295

RESUMO

INTRODUCTION: The aim of this study was to assess cyclic fatigue resistance in rotary nickel-titanium instruments submitted to nitrogen ion implantation by using a custom-made cyclic fatigue testing apparatus. METHODS: Thirty K3 files, size #25, taper 0.04, were divided into 3 experimental groups as follows: group A, 12 files exposed to nitrogen ion implantation at a dose of 2.5 x 10(17) ions/cm(2), accelerating voltage of 200 kV, currents of 1 microA/cm(2), 130 degrees C temperature, and vacuum conditions of 10 x 10(-6) torr for 6 hours; group B, 12 nonimplanted files; and group C, 6 files submitted to thermal annealing for 6 hours at 130 degrees C. One extra file was used for process control. All files were submitted to a cyclic fatigue test that was performed with an apparatus that allowed the instruments to rotate freely, simulating rotary instrumentation of a curved canal (40-degree, 5-mm radius curve). An electric motor handpiece was used with a contra-angle of 16:1 at an operating speed of 300 rpm and a torque of 2 N-cm. Time to failure was recorded with a stopwatch in seconds and subsequently converted to number of cycles to fracture. Data were analyzed with the Student t test (P < .05). RESULTS: Ion-implanted instruments reached significantly higher cycle numbers before fracture (mean, 510 cycles) when compared with annealed (mean, 428 cycles) and nonimplanted files (mean, 381 cycles). CONCLUSIONS: Our results showed that nitrogen ion implantation improves cyclic fatigue resistance in rotary nickel-titanium instruments. Industrial implementation of this surface modification technique would produce rotary nickel-titanium instruments with a longer working life.


Assuntos
Ligas Dentárias/química , Níquel/química , Nitrogênio/química , Preparo de Canal Radicular/instrumentação , Titânio/química , Técnicas Eletroquímicas , Falha de Equipamento , Humanos , Teste de Materiais , Metalurgia , Pressão , Rotação , Estresse Mecânico , Propriedades de Superfície , Temperatura , Fatores de Tempo , Torque , Vácuo
10.
Rev. odontol. UNESP (Online) ; 39(2): 89-94, abr. 2010. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-874372

RESUMO

Este estudo avaliou a resistência à fadiga flexural de instrumentos rotatórios de níquel-titânio de diferentes características geométricas, antes e após o uso em canais artificiais. Foram selecionados instrumentos rotatórios dos sistemas Race (FKG Dentaire) e K3 (SybronEndo) com diâmetro de ponta de 0,25 mm, conicidade 0,04 e 25 mm de comprimento. Os instrumentos foram divididos em quatro grupos (n = 12 cada grupo), totalizando 48 instrumentos, como segue: Grupo Controle 01 (GC 01), instrumentos Race sem uso; Grupo Controle 02 (GC 02), instrumentos K3 sem uso; Grupo Experimental 01 (GE 01), instrumentos Race de cinco usos, e Grupo Experimental 02 (GE 02), instrumentos K3 de cinco usos. A simulação de uso foi realizada em canais artificiais de resina, com ângulo de curvatura de 40° e raio de 5 mm, utilizando-se um motor elétrico com velocidade de 350 rpm e torque de 1 N.cm-1.Todos os grupos foram submetidos a ensaios de fadiga flexural em um dispositivo que permitia ao instrumento girar livremente, reproduzindo a instrumentação rotatória em canal curvo. O tempo despendido até a fratura foi aferido por um cronômetro. O teste ANOVA mostrou diferença estatisticamente significante entre as amostras (p < 0,05). O uso e a característica geométrica dos instrumentos influenciam na sua resistência à fadiga flexural (p < 0,05). Os instrumentos do GC 01 (K3 sem uso) apresentaram maior resistência à fadiga, quando comparados aos instrumentos dos demais grupos, independentemente do número de usos.


This study evaluated the flexural fatigue resistance of rotary instruments of nickel-titanium with different geometrical characteristics before and after use in artificial root canals. Systems Race (FKG Dentaire) and K3 (SybronEndo) with tip diameter of 0.25 mm, 0.04 taper and 25 mm of length were the rotary instruments selected. The instruments were divided into four groups (n = 12 each group), totaling forty-eight instruments, as follows: 01 Control Group (CG 01), new instruments unused Race; 02 Control Group (CG 02), new instruments unused K3 instruments ; Experimental Group 01 (SG 01), five uses Race instruments and Experimental Group 02 (SG 02), five instruments K3 uses. The simulation was carried out using artificial canals in resin, angle of curvature of 40 and a radius of 5 mm, using an electric motor with a speed of 350 rpm and 1 N.cm-1 of torque. All groups were tested for flexural fatigue in a device that allowed the instrument to rotate freely, reproducing the rotary movement in curved canals. The time spent until the fracture was measured by a chronometer. The ANOVA test showed significant difference between samples (p < 0.05). The use and feature geometric instruments influence the resistance to flexural fatigue (p < 0.05). The instruments of GC 01 (K3 unused) showed greater resistance to fatigue when compared to other groups of instruments, regardless of the number of use.


Assuntos
Análise de Variância , Endodontia , Instrumentos Odontológicos , Níquel , Titânio
11.
Rev. odontol. UNESP (Online) ; 38(1): 37-43, jan.-fev. 2009. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-621787

RESUMO

O objetivo deste trabalho é avaliar a eficiência de remoção do hidróxido de cálcio [Ca (OH)2] do interior do canal radicular, valendo-se de diferentes métodos. Vinte e seis incisivos inferiores foram preparados com a técnica escalonada regressiva e preenchidos com Ca(OH)2associado a soro fisiológico. As amostras foram armazenadas a 37 °C, em 100% de umidade relativa, por sete dias e foram divididas em dois grupos, de acordo com a técnica de remoção da medicação intracanal. No Grupo1 (G1): irrigação com 5 mL de hipoclorito de sódio 1%; limagem com instrumento memória por 1 minuto; irrigação com 5 mL de hipoclorito de sódio 1%; patência por 10 segundos; irrigação final com 10 mL de EDTA-T 17%. No Grupo 2 (G2), procederam-se as mesmas etapas do G1, acrescendo-se o uso do ultrassom por 1 minuto com lima #15. As amostras foram avaliadas qualitativamente em microscópio eletrônico de varredura, por meio de imagens de diferentes áreas do terço apical. De acordo com o teste de Mann-Whitney, com nível de significância de 5%, G1 não diferiu estatisticamente do G2. O teste de Friedman indicou diferenças estatisticamente significativas entre as áreas do terço apical para os dois grupos, sugerindo que à medida que se aproxima da área mais apical, menos eficaz é a remoção do hidróxido de cálcio. Os resultados mostraram que nenhuma técnica removeu completamenteo Ca (OH)2 do canal radicular.


The purpose of this study was to evaluate the efficiency of different methods of removal of calcium hydroxide [Ca (OH)2]. Twenty six inferior incisors had been prepared using the regressive technique and filled with Ca (OH)2. The samples had been stored to 37 °C in 100% of relative humidity per 7 days. The teeth had been divided in two groups in accordance with the technique of removal of the intracanal medication. In the Grupo1 (G1) ? 5 mL of 1% sodium hypochlorite (NaOCl); instrumented for 1 minute; 5 mL of 1% NaOCl; patency per 10 seconds; 10 mL of EDTA - T 17%. Group 2 (G2) follows the same stages of the G1, increasing the use of the ultrasonic for 1 minute. The samples had been evaluated qualitatively in electron microscope, through images of different areas of apical third. In accordance with the test of Mann-Whitney, with level of significance of 5%, G1 does not differ from G2. The test of Friedman indicates significant differences between the areas of apical third for the two groups. Results showed that no technique removed all Ca (OH)2.


Assuntos
Irrigantes do Canal Radicular , Hipoclorito de Sódio , Ultrassom , Hidróxido de Cálcio , Microscopia Eletrônica de Varredura , Cavidade Pulpar , Estatísticas não Paramétricas
12.
Rev. ABENO ; 9(1): 11-16, 2009.
Artigo em Português | BBO - Odontologia | ID: biblio-868317

RESUMO

O propósito deste artigo é apresentar resultados parciais de um estudo sobre concepções e práticas de avaliação de aprendizagem de docentes do Curso de Odontologia do Centro Universitário do Pará - CESUPA. O objetivo principal é analisar as concepções e significados atribuídos pelos docentes às atividades avaliativas discentes. O percurso metodológico compreendeu uma revisão bibliográfica sobre avaliação do processo-ensino aprendizagem, a seleção de depoimentos oriundos de questionário semi-estruturado aplicado junto a 16 docentes do Curso de Odontologia; sistematização, análise e discussão dos resultados, orientadas pela técnica de análise de conteúdo. Os resultados revelam o predomínio de uma concepção formativa de suas práticas avaliativas, além da presença de uma prática docente mais crítica e transformadora (AU).


The objective of the present study was to consider the evaluation practices of the Dentistry Course of the Pará University Center (CESUPA). The main purpose was to analyze conceptions and meanings attributed by the faculty to their evaluation practices. The methodological process involved a bibliographic review of higher education teaching, emphasizing both national and international scientific productions, particularly texts on the learning evaluation and specifically on the teaching of dentistry; a questionnaire applied to 16 professors from different years of the Dentistry Course; systematization of data; and analysis and discussion of the results through content analysis. The results revealed the predominance of a formative conception of their evaluation practices (AU).


Assuntos
Humanos , Masculino , Feminino , Estudos Prospectivos , Pesquisa em Odontologia/estatística & dados numéricos , Avaliação Educacional/estatística & dados numéricos , Docentes de Odontologia/estatística & dados numéricos , Percepção Social , Brasil/epidemiologia , Inquéritos e Questionários , Educação em Odontologia
13.
JBE j. bras. endodontia ; 5(20): 372-375, mar.-jun. 2005. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-521913

RESUMO

O objetivo do presente estudo foi avaliar a resistência à torção de instrumentos rotatórios de níquel-titânio em razão do diâmetro da sua ponta. Trinta limas Quantec Faire de conicidade 0,10mm e comprimento de 17mm foram divididas em dois grupos de quinze limas casa. No grupo I, não se realizou nenhuma modificação nas limas, enquanto que no grupo II foi removido 1mm da extremidade do instrumento, transformando o seu d1 de 0,25mmm para 0,35mm. Um suporte metálico foi utilizado para manter a peça de mão em posição como também apreender a extremidade de lima durante os ensaios de torção. Foi utilizado um motor elétrico e um contra-ângulo redutor (16:1) com velocidade calibrada em 350rpm com aumento gradativo de torque. O torque máximo que cada lima suportou antes de fraturada foi medido por um torquímetro acoplado ao suporte. Os resultados mostraram qeu os instrumentos com a ponta modificada apresentam superioridade de resistência à torção, quando comparados aos instrumentos de diâmetro original.


Assuntos
Anormalidade Torcional/diagnóstico , Instrumentos Odontológicos , Níquel/química , Preparo de Canal Radicular/instrumentação , Teste de Materiais/normas , Titânio/química , Interpretação Estatística de Dados
14.
São Paulo; s.n; 2003. 92 p. ilus, tab. (BR).
Tese em Português | LILACS, BBO - Odontologia | ID: lil-388531

RESUMO

O objetivo do presente estudo foi avaliar a resistência à fadiga cíclica dos instrumentos rotatórios de níquel-titânio, após diferentes números de uso, valendo-se de dispositivo desenvolvido para realizar ensaios dinâmicos. Foram selecionadas limas rotatórias Race (FKG Dentaire) de conicidade 0,04, 25 mm de comprimento e diâmetro de ponta 25, padrão ISO. As mesmas foram divididas em quatro grupos experimentais com doze limas cada, totalizando quarenta e oito limas. Os grupos foram assim divididos: grupo A, instrumentos sem nenhum uso; grupo B, instrumentos de um único uso; grupo C, de três usos e grupo D, de cinco usos. A simulação foi realizada em canais artificiais de resina com curvatura de 40º e raio de 5 mm. Todas as limas foram submetidas a ensaios de fadiga cíclica que foi realizado num dispositivo que permitia o instrumento girar livremente, reproduzindo uma instrumentação rotatória num canal curvo. Foi utilizada uma peça de mão com contra-ângulo redutor de 16:1, acionado por motor elétrico na velocidade de 300 rpm e 2 N cm de torque. O tempo despendido até a fratura foi aferido por um cronômetro. Para a avaliação estatística empregou-se o teste de ANOVA para um fator de variação e observou-se diferença significante entre as amostras. O teste de Tukey foi utilizado para determinar a diferença entre as médias dos grupos experimentais. Os resultados mostraram que os instrumentos do grupo A exibiram maior resistência a fadiga cíclica, não havendo diferença entre este e o grupo B. As limas empregadas cinco vezes (grupo D) apresentaram a maior fadiga cíclica quando comparadas aos espécimes dos demais grupos experimentais (p < 0,05).


Assuntos
Instrumentos Odontológicos , Endodontia , Fadiga
15.
Rev. odontol. Univ. Säo Paulo ; 8(2): 95-101, abr.-jun. 1994. tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-143467

RESUMO

O presente trabalho teve por objetivo comparar três grupos de operadores (especialistas em Endodontia, clínicos gerais e acadêmicos de Odontologia) relativamente a capacidade e eficiência de corte, valendo-se da pesagem de dentes humanos extraídos antes e após o preparo químico-mecânico dos canais radiculares. Ocorreram variaçöes no desgaste da dentina quando do preparo químico-mecânico do canal radicular em funçäo dos três grupos de operadores. O grupo dos especialistas proporcionou a maior quantidade de dentina removida, seguindo-se, em ordem decrescente, os clínicos e os acadêmicos e, entre esses dois últimos grupos, näo ocorreu diferença significativa no ponto de vista estatístico. O grupo dos especialistas consumiu o menor tempo para o preparo químico-mecânico do canal radicular, seguindo-se, em ordem decrescente, o dos clínicos gerais e o dos acadêmicos e, entre esses dois últimos grupos, näo houve diferença estatisticamente significante. O grupo dos especialistas propiciou maior eficiência no que respeita ao desgaste dentinário, perfilando-se, em ordem decrescente, o grupo dos clínicos gerais e dos acadêmicos, havendo diferença estatisticamente significante entre os três grupos


Assuntos
Tratamento do Canal Radicular/instrumentação , Especialização , Fatores de Tempo , Conhecimentos, Atitudes e Prática em Saúde , Eficiência , Endodontia , Corpo Clínico
16.
Rev. odontol. UNICID ; 5(1): 21-6, jan.-jun. 1993. tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-150340

RESUMO

O objetivo deste trabalho foi de analisar a morfologia obtida, em dentes diafanizadas, por canais radiculares preparados pela técnica convencional e pela técnica escalonada. Para tanto, 30 raízes mesiais de primeiros molares inferiores foram divididos em dois grupos de 15 e preparados por duas técnicas. Após a diafanizaçäo dos dentes, observou-se visualmente que o preparo convencional mostrou uma incidência maior de conicidade näo gradual, nos três terços, e de desvio apical em cerca de 23,3 por cento dos casos. O preparo escalonado exibiu desvio apical em 3,3 por cento dos casos, além de apresentar a melhor conicidade gradual nos três terços


Assuntos
Tratamento do Canal Radicular , Tratamento do Canal Radicular/instrumentação
17.
Odontol. USF ; 10(1/2): 27-34, jan.-dez. 1992. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-852203

RESUMO

Amálgama de prata, cimento de N-Rickert e ionômero de vidro foram utilizados, "in vitro", como materiais retro-obturadores. Após imersão no corante azul de metileno a 2//, foram obtidos índices de penetração para cada material utilizado, quando o cimento de N-Rickert mostrou-se superior


Assuntos
Humanos , Materiais Restauradores do Canal Radicular , Obturação do Canal Radicular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...