Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 609
Filtrar
1.
Phys Chem Chem Phys ; 26(19): 14448-14455, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38713487

RESUMO

Cobaltcarbonyl-tert-butylacetylene (CCTBA) is a conventional precursor for the selective atomic layer deposition of Co onto silicon surfaces. However, a limited understanding of the deposition mechanism of such cobalt precursors curbs rational improvements on their design for increased efficiency and tuneable selectivity. The impact of using a less reactive internal alkyne instead of a terminal alkyne was investigated using experimental and computational methods. Using electrospray-ionization mass spectrometry, the formation of CCTBA analogs and their gas phase decomposition pathways were studied. Decomposition experiments show very similar decomposition pathways between the two complexes. The internal alkyne dissociates from the Co complex at slightly lower energies than the terminal alkyne, suggesting that an internal alkynyl ligand may be more suited to low temperature ALD. In addition, transition state calculations using the nudged elastic band method confirm an increased reaction barrier between the internal alkyne and the Si-H surface bonds on Si(111). These results suggests that using a less reactive internal alkyne will result in fewer embedded carbon impurities during deposition onto Si wafers. DFT calculations using the PBE functional and periodic boundary conditions also predict increased surface binding with the metal centers of the internal alkynyl complex.

2.
J Am Chem Soc ; 146(15): 10581-10590, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38580459

RESUMO

Positron emission tomography is a widely used imaging platform for studying physiological processes. Despite the proliferation of modern synthetic methodologies for radiolabeling, the optimization of these reactions still primarily relies on inefficient one-factor-at-a-time approaches. High-throughput experimentation (HTE) has proven to be a powerful approach for optimizing reactions in many areas of chemical synthesis. However, to date, HTE has rarely been applied to radiochemistry. This is largely because of the short lifetime of common radioisotopes, which presents major challenges for efficient parallel reaction setup and analysis using standard equipment and workflows. Herein, we demonstrate an effective HTE workflow and apply it to the optimization of copper-mediated radiofluorination of pharmaceutically relevant boronate ester substrates. The workflow utilizes commercial equipment and allows for rapid analysis of reactions for optimizing reactions, exploring chemical space using pharmaceutically relevant aryl boronates for radiofluorinations, and constructing large radiochemistry data sets.


Assuntos
Cobre , Tomografia por Emissão de Pósitrons , Radioquímica , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Radioisótopos de Flúor
3.
Org Lett ; 26(16): 3419-3423, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38630573

RESUMO

We present a photo- and Cu-mediated 11C cyanation of bench-stable (hetero)aryl thianthrenium salts via an aryl radical addition pathway. The thianthrenium substrates can be readily accessed via C-H functionalization, and the radiocyanation protocol proceeds under mild conditions (<50 °C, 5 min) and can be automated using open-source, readily accessible augmentations to existing radiochemistry equipment.

4.
Nucl Med Biol ; 132-133: 108907, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38599143
5.
Nucl Med Biol ; 130-131: 108892, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38447298

RESUMO

INTRODUCTION: Increased demand for NetSpot and Illuccix as requirement to receive the respective Lutathera and Pluvicto radiotherapies, and monitor subsequent response to treatment, have reinforced the need to develop alternative ways of producing gallium-68 (68Ga). Building on our efforts to produce 68Ga in a liquid target on a GE PETtrace, the goal of this work is to modify the current GE Gallium Chloride cassette using the FASTLab 2 synthesis module to produce [68Ga]GaCl3 equivalent to a 1.85 GBq generator and demonstrate compatibility with FDA-approved kits for production of 68Ga-labeled radiopharmaceuticals. METHODS: 68Ga was produced in a liquid target via the 68Zn(p,n)68Ga reaction. 68Ga was loaded onto various sizes of ZR resins (ZR Load, 0.3 mL, 1 mL, or 2 mL). The loading efficiency was determined using a dose calibrator. After washing with HNO3, 1.75 M HCl was used to elute the ZR Load resin through various sizes of a second ZR resin (ZR CG, 0 mL, 2 mL, 4 mL). Using 0.5 mL fractions, the elution profile was determined. Compatibility of the [68Ga]GaCl3 with NetSpot and Illuccix kits was investigated. Radiochemical purity (RCP) and 4 h stability were determined using radioTLC and radioHPLC. Using a modified [68Ga]GaCl3 cassette and new FASTLab program, 6 validation preparations were conducted using NetSpot and Illuccix kits for which RCP, stability, sterility and suitability were determined. Dual irradiation of 2 liquid targets was also performed, which was used to simultaneously prepare 1 NetSpot and 2 Illuccix kits by diluting the required activity with 0.1 M HCl. RESULTS: The commercially available GE Cassette gave low RCP using commercial FDA kits. To optimize this, the loading efficiency onto ZR Load and the ratio of ZR resin used to load the initial activity and subsequent elution were explored. When using a 2:4 ratio of ZR Load to ZR CG, 97.89 % RCP was observed when a 3.8 mL [68Ga]GaCl3 solution was used. For Dotatate validation, 0.55 mL of buffer was added to 4.2 mL of [68Ga]GaCl3 which gave 1.35 GBq of formulated product. For Illuccix validation, [68Ga]GaCl3 was added to 2.5 mL of buffer which gave 1.52 GBq of [68Ga]Ga-PSMA-11. Formulated products passed package insert quality control (QC) requirements. When dual target irradiations were performed, 2.84 GBq was delivered to an external vial and used to label 1 NetSpot and 2 Illuccix kits simultaneously, and each kit also met or exceeded established QC criteria. CONCLUSION: Methods are reported for using cyclotron-produced 68Ga from a liquid target in conjunction with FDA-approved NetSpot and Illucix kits. By employing a 2 mL ZR Load resin with a 4 mL ZR CG resin, adequate resolution between residual 68Zn and desired 68Ga was achieved. By modifying the FASTLab procedure to retain the final 2.5 mL of eluate from the ZR CG resin, [68Ga]GaCl3 equivalent to a new 1.85 GBq generator was obtained. This was suitable for labeling NetSpot and Illucix kits, resulting in high incorporation of 68Ga (RCP >95 %), which has not previously been demonstrated. Delivering [68Ga]GaCl3 into an external vial and diluting with 0.1 M HCl makes it possible to prepare multiple kits simultaneously. These new procedures should facilitate use of cyclotron-produced [68Ga]GaCl3 for clinical production going.


Assuntos
Radioisótopos de Gálio , Compostos Organometálicos , Compostos Radiofarmacêuticos , Compostos Radiofarmacêuticos/metabolismo , Radioisótopos de Gálio/metabolismo , Ciclotrons
6.
Chimia (Aarau) ; 78(3): 123-128, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38547013

RESUMO

Two applications of a radical trap based on a homolytic substitution reaction (SH2') are presented for the trapping of short-lived radical intermediates in organic reactions. The first example is a photochemical cyanomethylation catalyzed by a Ru complex. Two intermediate radicals in the radical chain propagation have been trapped and detected using mass spectrometry (MS), along with the starting materials, products and catalyst degradation fragments. Although qualitative, these results helped to elucidate the reaction mechanism. In the second example, the trapping method was applied to study the radical initiation catalyzed by a triethylboronoxygen mixture. In this case, the concentration of trapped radicals was sufficiently high to enable their detection by nuclear magnetic resonance (NMR). Quantitative measurements made it possible to characterize the radical flux in the system under different reaction conditions (including variations of solvent, temperature and concentration) where modelling was complicated by chain reactions and heterogeneous mass transfer.

7.
J Am Soc Mass Spectrom ; 35(3): 449-455, 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38345910

RESUMO

Mass spectrometers have an enormous number of user-changeable parameters that drastically affect the observed mass spectrum. Using optimal parameters can significantly improve mass spectrometric data by increasing signal stability and signal-to-noise ratio, which decreases the limit of detection, thus revealing previously unobservable species. However, ascertaining optimal parameters is time-consuming, tedious, and made further challenging by the fact that parameters can act dependently on each other. Consequently, suboptimal parameters are frequently used during characterization, reducing the quality of results. OptiMS, an open-source, cross-platform program, was developed to simplify, accelerate, and more accurately determine optimal mass spectrometer parameters for a given system. It addresses common difficulties associated with existing software such as slow performance, high costs, and limited functionality. OptiMS efficacy was demonstrated through its application to multiple systems, quickly and successfully optimizing instrument parameters unassisted to maximize a user-defined metric, such as the intensity of a particular analyte. Additionally, among other features, OptiMS allows running of a sequence of predefined parameter configurations, reducing the workload of users wishing to obtain mass spectra under multiple sets of conditions.

8.
J Pain ; 25(4): 1070-1081, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37956741

RESUMO

This study explored the association between experimentally-induced pain sensitivity and µ-opioid receptor (µOR) availability in patients with temporomandibular disorder (TMD) and further investigated any changes in the pain and µOR availability following high-definition transcranial direct current stimulation (HD-tDCS) over the primary motor cortex (M1) with pilot randomized clinical trials. Seven patients with TMD completed either active (n = 3) or sham treatment (n = 4) for 10 daily sessions and underwent positron emission tomography (PET) scans with [11C]carfentanil, a selective µOR agonist, a week before and after treatment. PET imaging consisted of an early resting and late phase with the sustained masseteric pain challenge by computer-controlled injection of 5% hypertonic saline. We also included 12 patients with TMD, obtained from our previous study, for baseline PET analysis. We observed that patients with more sensitivity to pain, indicated by lower infusion rate, had less µOR availability in the right amygdala during the late phase. Moreover, active M1 HD-tDCS, compared to sham, increased µOR availability post-treatment in the thalamus during the early resting phase and the amygdala, hippocampus, and parahippocampal gyrus during the late pain challenge phase. Importantly, increased µOR availability post-treatment in limbic structures including the amygdala and hippocampus was associated with decreased pain sensitivity. The findings underscore the role of the µOR system in pain regulation and the therapeutic potential of HD-tDCS for TMD. Nonetheless, large-scale studies are necessary to establish the clinical significance of these results. TRIAL REGISTRATION: ClinicalTrial.gov (NCT03724032) PERSPECTIVE: This study links pain sensitivity and µ-opioid receptors in patients with TMD. HD-tDCS over M1 improved µOR availability, which was associated with reduced pain sensitivity. Implications for TMD pain management are promising, but larger clinical trials are essential for validation.


Assuntos
Transtornos da Articulação Temporomandibular , Estimulação Transcraniana por Corrente Contínua , Humanos , Estimulação Transcraniana por Corrente Contínua/métodos , Projetos Piloto , Limiar da Dor/fisiologia , Dor , Transtornos da Articulação Temporomandibular/diagnóstico por imagem , Transtornos da Articulação Temporomandibular/terapia
9.
Macromol Rapid Commun ; 45(2): e2300470, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37716013

RESUMO

Herein, an evaluation of the initial step of benzoxazine polymerization is presented by mass spectrometry, with a focus on differentiating the phenoxy and phenolic products formed by distinct pathways of the cationic ring opening polymerization (ROP) mechanism of polybenzoxazine formation. The use of infrared multiple photon dissociation (IRMPD) and ion mobility spectrometry (IMS) techniques allows for differentiation of the two pathways and provides valuable insights into the ROP mechanism. The results suggest that type I pathway is favored in the initial stages of the reaction yielding the phenoxy product, while type II product should be observed at later stages when the phenoxy product would interconvert to the most stable type II phenolic product. Overall, the findings presented here provide important information on the initial step of the benzoxazine polymerization, allowing the development of optimal polymerization conditions and represents a way to evaluate other multifunctional polymerization processes.


Assuntos
Benzoxazinas , Fenóis , Polimerização , Benzoxazinas/química , Fenóis/química , Cátions
10.
Angew Chem Int Ed Engl ; 63(2): e202316365, 2024 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-38010255

RESUMO

This report describes the development of a Zn(OTf)2 -mediated method for converting α-tertiary haloamides to the corresponding fluorine-18 labelled α-tertiary fluoroamides with no-carrier-added [18 F]tetramethylammonium fluoride. 1,5,7-Triazabicyclo[4.4.0]dec-5-ene is an essential additive for achieving high radiochemical conversion. Under the optimised conditions, radiofluorination proceeds at sterically hindered tertiary sites in high radiochemical conversions, yields, and purities. This method has been successfully automated and applied to access >200 mCi (>7.4 GBq) of several model radiofluorides. Mechanistic studies led to the development of a new, nucleophilic C-H radiofluorination process using N-sulphonyloxyamide substrates.

11.
Methods Mol Biol ; 2729: 45-53, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38006490

RESUMO

Direct C-H functionalization of (hetero)aromatic C-H bonds with iridium-catalyzed borylation followed by copper-mediated radiofluorination of the in situ generated organoboronates affords fluorine-18 labeled aromatics in high radiochemical conversions and meta-selectivities. This protocol describes the benchtop reaction assembly of the C-H borylation and radiofluorination steps, which can be utilized for the fluorine-18 labeling of densely functionalized bioactive scaffolds.


Assuntos
Cobre , Irídio , Cobre/química , Irídio/química , Radioisótopos de Flúor/química , Catálise
12.
Brain Sci ; 13(12)2023 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-38137159

RESUMO

Flumazenil is an allosteric modulator of the γ-aminobutyric acid-A receptor (GABAAR) benzodiazepine binding site that could normalize neuronal signaling and improve motor impairments in Parkinson's disease (PD). Little is known about how regional GABAAR availability affects motor symptoms. We investigated the relationship between regional availability of GABAAR benzodiazepine binding sites and motor impairments in PD. Methods: A total of 11 Patients with PD (males; mean age 69.0 ± 4.6 years; Hoehn and Yahr stages 2-3) underwent [11C]flumazenil GABAAR benzodiazepine binding site and [11C]dihydrotetrabenazine vesicular monoamine transporter type-2 (VMAT2) PET imaging and clinical assessment. Stepwise regression analysis was used to predict regional cerebral correlates of the four cardinal UPDRS motor scores using cortical, striatal, thalamic, and cerebellar flumazenil binding estimates. Thalamic GABAAR availability was selectively associated with axial motor scores (R2 = 0.55, F = 11.0, ß = -6.4, p = 0.0009). Multi-ligand analysis demonstrated significant axial motor predictor effects by both thalamic GABAAR availability (R2 = 0.47, ß = -5.2, F = 7.2, p = 0.028) and striatal VMAT2 binding (R2 = 0.30, ß = -3.9, F = 9.1, p = 0.019; total model: R2 = 0.77, F = 11.9, p = 0.0056). Post hoc analysis demonstrated that thalamic [11C]methyl-4-piperidinyl propionate cholinesterase PET and K1 flow delivery findings were not significant confounders. Findings suggest that reduced thalamic GABAAR availability correlates with worsened axial motor impairments in PD, independent of nigrostriatal degeneration. These findings may augur novel non-dopaminergic approaches to treating axial motor impairments in PD.

13.
EJNMMI Radiopharm Chem ; 8(1): 39, 2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-37950112

RESUMO

The International Atomic Energy Agency (IAEA) held the 3rd International Symposium on Trends in Radiopharmaceuticals, (ISTR-2023) at IAEA Headquarters in Vienna, Austria, during the week of 16-21 April 2023. This procedural paper summarizes highlights from symposium presentations, posters, panel discussions and satellite meetings, and provides additional resources that may be useful to researchers working with diagnostic and therapeutic radiopharmaceuticals in the academic, government and industry setting amongst IAEA Member States and beyond. More than 550 participants in person from 88 Member States attended the ISTR-2023. Over 360 abstracts were presented from all over the world by a diverse group of global scientists working with radiopharmaceuticals. Given this group of international radiochemists is unique to ISTR (IAEA funding enabled many to attend), there was an invaluable wealth of knowledge on the global state of the radiopharmaceutical sciences present at the meeting. The intent of this Proceedings paper is to share this snapshot from our international colleagues with the broader radiopharmaceutical sciences community by highlighting presentations from the conference on the following topics: Isotope Production and Radiochemistry, Industrial Insights, Regional Trends, Training and Education, Women in the Radiopharmaceutical Sciences, and Future Perspectives and New Initiatives. The authors of this paper are employees of IAEA, members of the ISTR-2023 Organizing Committee and/or members of the EJNMMI Radiopharmacy and Chemistry Editorial Board who attended ISTR-2023. Overall, ISTR-2023 fostered the successful exchange of scientific ideas around every aspect of the radiopharmaceutical sciences. It was well attended by a diverse mix of radiopharmaceutical scientists from all over the world, and the oral and poster presentations provided a valuable update on the current state-of-the-art of the field amongst IAEA Member States. Presentations as well as networking amongst the attendees resulted in extensive knowledge transfer amongst the various stakeholders representing 88 IAEA Member States. This was considered particularly valuable for attendees from Member States where nuclear medicine and the radiopharmaceutical sciences are still relatively new. Since the goal is for the symposium series to be held every four years; the next one is anticipated to take place in 2027.

14.
Chem Sci ; 14(43): 12068-12072, 2023 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-37969612

RESUMO

This report describes a net C-H radiocyanation reaction for the transformation of electron rich (hetero)aromatic substrates into 11CN-labeled products. Electrophilic C(sp2)-H iodination of the (hetero)arene with N-iodosuccinimide is followed by Cu-mediated radiocyanation with K11CN. This sequence is applied to a variety of substrates, including the nucleobases uracil and cytosine, the amino acids tyrosine and tryptophan, and the peptide LYRAGWRAFS, which undergoes selective C-H radiocyanation at the tryptophan (W) residue.

15.
J Nucl Med ; 64(12): 1848-1854, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37827839

RESUMO

The development of artificial intelligence (AI) within nuclear imaging involves several ethically fraught components at different stages of the machine learning pipeline, including during data collection, model training and validation, and clinical use. Drawing on the traditional principles of medical and research ethics, and highlighting the need to ensure health justice, the AI task force of the Society of Nuclear Medicine and Molecular Imaging has identified 4 major ethical risks: privacy of data subjects, data quality and model efficacy, fairness toward marginalized populations, and transparency of clinical performance. We provide preliminary recommendations to developers of AI-driven medical devices for mitigating the impact of these risks on patients and populations.


Assuntos
Inteligência Artificial , Aprendizado de Máquina , Humanos , Coleta de Dados , Comitês Consultivos , Imagem Molecular
16.
Chem Sci ; 14(36): 9970-9977, 2023 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-37736619

RESUMO

Kinetic analysis of catalytic reactions is a powerful tool for mechanistic elucidation but is often challenging to perform, limiting understanding and therefore development of these reactions. Establishing order in a catalyst is usually achieved by running several reactions at different loadings, which is both time-consuming and complicated by the challenge of maintaining consistent run-to-run experimental conditions. Continuous addition kinetic elucidation (CAKE) was developed to circumvent these issues by continuously injecting a catalyst into a reaction, while monitoring reaction progress over time. For reactions that are mth order in a single yield-limiting reactant and nth order in catalyst, a plot of reactant concentration against time has a shape dependent only on the orders m and n. Therefore, fitting experimental CAKE data (using open access code or a convenient web tool) allows the reactant and catalyst orders, rate constant, and the amount of complete catalyst inhibition to be determined from a single experiment. Kinetic information obtained from CAKE experiments showed good agreement with the literature.

17.
J Nucl Med ; 64(10): 1509-1515, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37620051

RESUMO

The deployment of artificial intelligence (AI) has the potential to make nuclear medicine and medical imaging faster, cheaper, and both more effective and more accessible. This is possible, however, only if clinicians and patients feel that these AI medical devices (AIMDs) are trustworthy. Highlighting the need to ensure health justice by fairly distributing benefits and burdens while respecting individual patients' rights, the AI Task Force of the Society of Nuclear Medicine and Molecular Imaging has identified 4 major ethical risks that arise during the deployment of AIMD: autonomy of patients and clinicians, transparency of clinical performance and limitations, fairness toward marginalized populations, and accountability of physicians and developers. We provide preliminary recommendations for governing these ethical risks to realize the promise of AIMD for patients and populations.


Assuntos
Medicina Nuclear , Médicos , Humanos , Inteligência Artificial , Comitês Consultivos , Imagem Molecular
18.
Artigo em Inglês | MEDLINE | ID: mdl-37608567

RESUMO

An in-loop 11 C-carbonylation process for the radiosynthesis of 11 C-carboxylic acids and esters from halide precursors has been developed. The reaction proceeds at room temperature under mild conditions and enables 11 C-carbonylation of both electron deficient and electron rich (hetero)aromatic halides to provide 11 C-carboxylic acids and esters in good to excellent radiochemical yields, high radiochemical purity, and excellent molar activity. The process has been fully automated using commercial radiochemistry synthesis modules, and application to clinical production is demonstrated via validated cGMP radiosyntheses of [11 C]bexarotene and [11 C]acetoacetic acid.

19.
J Pain Res ; 16: 2509-2523, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37497372

RESUMO

Objective: The current understanding of utilizing HD-tDCS as a targeted approach to improve headache attacks and modulate endogenous opioid systems in episodic migraine is relatively limited. This study aimed to determine whether high-definition transcranial direct current stimulation (HD-tDCS) over the primary motor cortex (M1) can improve clinical outcomes and endogenous µ-opioid receptor (µOR) availability for episodic migraineurs. Methods: In a randomized, double-blind, and sham-controlled trial, 25 patients completed 10-daily 20-min M1 HD-tDCS, repeated Positron Emission Tomography (PET) scans with a selective agonist for µOR. Twelve age- and sex-matched healthy controls participated in the baseline PET/MRI scan without neuromodulation. The primary endpoints were moderate-to-severe (M/S) headache days and responder rate (≥50% reduction on M/S headache days from baseline), and secondary endpoints included the presence of M/S headache intensity and the use of rescue medication over 1-month after treatment. Results: In a one-month follow-up, at initial analysis, both the active and sham groups exhibited no significant differences in their primary outcomes (M/S headache days and responder rates). Similarly, secondary outcomes (M/S headache intensity and the usage of rescue medication) also revealed no significant differences between the two groups. However, subsequent analyses showed that active M1 HD-tDCS, compared to sham, resulted in a more beneficial response predominantly in higher-frequency individuals (>3 attacks/month), as demonstrated by the interaction between treatment indicator and baseline frequency of migraine attacks on the primary outcomes. These favorable outcomes were also confirmed for the secondary endpoints in higher-frequency patients. Active treatment also resulted in increased µOR concentration compared to sham in the limbic and descending pain modulatory pathway. Our exploratory mediation analysis suggests that the observed clinical efficacy of HD-tDCS in patients with higher-frequency conditions might be potentially mediated through an increase in µOR availability. Conclusion: The 10-daily M1 HD-tDCS can improve clinical outcomes in episodic migraineurs with a higher baseline frequency of migraine attacks (>3 attacks/month). This improvement may be, in part, facilitated by the increase in the endogenous µOR availability. Clinical Trial Registration: www.ClinicalTrials.gov, identifier - NCT02964741.

20.
J Labelled Comp Radiopharm ; 66(9): 269-285, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37322805

RESUMO

Positron emission tomography (PET) is a powerful tool in medicine and drug development, allowing for non-invasive imaging and quantitation of biological processes in live organisms. Targets are often probed with small molecules, but antibody-based PET is expanding because of many benefits, including ease of design of new antibodies toward targets, as well as the very strong affinities that can be expected. Application of antibodies to PET imaging of targets in the central nervous system (CNS) is a particularly nascent field, but one with tremendous potential. In this review, we discuss the growth of PET in imaging of CNS targets, present the promises and progress in antibody-based CNS PET, explore challenges faced by the field, and discuss questions that this promising approach will need to answer moving forward for imaging and perhaps even radiotherapy.


Assuntos
Imunoconjugados , Tomografia por Emissão de Pósitrons , Tomografia por Emissão de Pósitrons/métodos , Anticorpos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...