Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Abdom Radiol (NY) ; 46(7): 3428-3436, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33606062

RESUMO

PURPOSE: To evaluate safety and efficacy of radiation segmentectomy (RS) with 90Y glass microspheres in patients with limited metastatic liver disease not amenable to resection or percutaneous ablation. METHODS: Patients with ≤ 3 tumors treated with RS from 6/2015 to 12/2017 were included. Target tumor radiation dose was > 190 Gy based on medical internal radiation dose (MIRD) dosimetry. Tumor response, local tumor progression (LTP), LTP-free survival (LTPFS) and disease progression rate in the treated segment were defined using Choi and RECIST 1.1 criteria. Toxicities were evaluated using modified SIR criteria. RESULTS: Ten patients with 14 tumors underwent 12 RS. Median tumor size was 3 cm (range 1.4-5.6). Median follow-up was 17.8 months (range 1.6-37.3). Response rates per Choi and RECIST 1.1 criteria were 8/8 (100%) and 4/9 (44%), respectively. Overall LTP rate was 3/14 (21%) during the study period. One-, two- and three-year LTPFS was 83%, 83% and 69%, respectively. Median LTPFS was not reached. Disease progression rate in the treated segment was 6/18 (33%). Median overall survival was 41.5 months (IQR 16.7-41.5). Median delivered tumor radiation dose was 293 Gy (range 163-1303). One major complication was recorded in a patient post-Whipple procedure who suffered anaphylactic reaction to prophylactic cefotetan and liver abscess in RS region 6.5 months post-RS. All patients were alive on last follow-up. CONCLUSION: RS of ≤ 3 hepatic segments can safely provide a 2-year local tumor control rate of 83% in selected patients with limited metastatic liver disease and limited treatment options. Optimal dosimetry methodology requires further investigation.


Assuntos
Neoplasias Hepáticas , Radioisótopos de Ítrio , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Microesferas , Pneumonectomia , Estudos Retrospectivos , Resultado do Tratamento , Radioisótopos de Ítrio/uso terapêutico
2.
Cardiovasc Intervent Radiol ; 41(10): 1530-1544, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29845348

RESUMO

PURPOSE: To review outcomes following microwave ablation (MWA) of colorectal cancer pulmonary metastases and assess predictors of oncologic outcomes. METHODS: Technical success, primary and secondary technique efficacy rates were evaluated for 50 patients with 90 colorectal cancer pulmonary metastases at immediate, 4-8 weeks post-MWA and subsequent follow-up CT and/or 18F-FDG PET/CT. Local tumor progression (LTP) rate, LTP-free survival (LTPFS), cancer-specific and overall survivals were assessed. Complications were recorded according to SIR classification. RESULTS: Median follow-up was 25.6 months. Median tumor size was 1 cm (0.3-3.2 cm). Technical success, primary and secondary technique efficacy rates were 99, 90 and 92%, respectively. LTP rate was 10%. One-, 2- and 3-year LTPFS were: 93, 86 and 86%, respectively, with median LTPFS not reached. Median overall survival was 58.6 months, and median cancer-specific survival (CSS) was not reached. One-, 2- and 3-year overall and CSS were 94% and 98, 82 and 90%, 61 and 70%, respectively. On univariate analysis, minimal ablation margin (p < 0.001) and tumor size (p = 0.001) predicted LTPFS, with no LTP for minimal margin ≥ 5 mm and/or tumor size < 1 cm. Pleural-based metastases were associated with increased LTP risk (p = 0.002, SHR = 7.7). Pre-MWA CEA level > 10 ng/ml (p = 0.046) and ≥ 3 prior chemotherapy lines predicted decreased CSS (p = 0.02). There was no 90-day death. Major complications rate was 13%. CONCLUSIONS: MWA with minimal ablation margin ≥ 5 mm is essential for local control of colorectal cancer pulmonary metastases. Pleural-based metastases and larger tumor size were associated with higher risk of LTP. CEA level and pre-MWA chemotherapy impacted CSS.


Assuntos
Ablação por Cateter/métodos , Neoplasias Colorretais/cirurgia , Neoplasias Pulmonares/secundário , Micro-Ondas/uso terapêutico , Adulto , Idoso , Neoplasias Colorretais/diagnóstico por imagem , Feminino , Fluordesoxiglucose F18 , Seguimentos , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/cirurgia , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
3.
Cardiovasc Intervent Radiol ; 41(9): 1419-1427, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29766239

RESUMO

OBJECTIVES: To assess safety and efficacy of 90Y resin microspheres administration using undiluted non-ionic contrast material (UDCM) {100% Omnipaque-300 (Iohexol)} in both the "B" and "D" lines. MATERIALS AND METHODS: We reviewed all colorectal cancer liver metastases patients treated with 90Y resin microspheres radioembolization (RAE) from 2009 to 2017. As of April 2013, two experienced operators started using UDCM (study group) instead of standard sandwich infusion (control group). Occurrence of myelosuppression (leukopenia, neutropenia, erythrocytopenia or/and thrombocytopenia), stasis, nontarget delivery (NTD), median fluoroscopy radiation dose (FRD), median infusion time (IT), liver progression-free (LPFS) and overall survivals (OS) was evaluated. Complications within 6 months post-RAE were reported according to CTCAE v3.0 criteria. RESULTS: Study and control groups comprised 23(28%) and 58(72%) patients, respectively. Median follow-up was 9.1 months. There was no statistically significant difference in myelosuppression incidence within 6 months post-RAE between groups. Median FRD and IT for study and control groups were 44.6 vs. 97.35 Gy/cm2 (p = 0.048) and 31 vs. 39 min (p = 0.006), respectively. A 38% lower stasis incidence in study group was not significant (p = 0.34). NTD occurred in 1/27(4%) study vs. 5/73(7%) control group procedures (p = 1). Grade 1-2 and grade 3-4 toxicities between study and control group patients were 36%(8/22) vs. 45%(26/58), p = 0.61 and 9%(2/22) vs. 16%(9/58), p = 0.72, respectively. There was no difference in LPFS and OS between groups. CONCLUSION: Administration of 90Y resin microspheres using UDCM in both lines is safe and effective, resulting in lower fluoroscopy radiation dose and shorter infusion time, without evidence of myelosuppression or increased stasis incidence.


Assuntos
Braquiterapia/métodos , Neoplasias Colorretais/radioterapia , Embolização Terapêutica/métodos , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/secundário , Microesferas , Radioisótopos de Ítrio/uso terapêutico , Adulto , Idoso , Braquiterapia/efeitos adversos , Neoplasias Colorretais/mortalidade , Embolização Terapêutica/efeitos adversos , Feminino , Seguimentos , Humanos , Iohexol , Neoplasias Hepáticas/mortalidade , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Análise de Sobrevida , Resultado do Tratamento , Radioisótopos de Ítrio/efeitos adversos
4.
Cardiovasc Intervent Radiol ; 41(1): 104-111, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28770316

RESUMO

PURPOSE: Dedicated tumor feeding vessel detection software (TFVDS) using cone beam CT has shown a higher sensitivity to detect tumor feeding vessels during hepatic arterial embolization (HAE) of hepatocellular carcinoma (HCC) compared to 2D imaging. Our primary hypothesis was that HCC tumors treated with HAE guided by a TFVDS would show more complete response (CR) than when treated with 2D imaging alone. Secondary analysis of the impact on X-ray exposure was performed. MATERIALS AND METHODS: Nineteen males and 8 females (median age: 69 year, 46-85) with 44 tumors (median size: 38 mm, 6-100) treated with selective HAE between January 2013 and December 2014 were included. Exclusion criteria were: extra-hepatic supply, >4 tumors, tumor size >10 cm, and adjunctive local therapy. Baseline patient and procedure characteristics were reviewed. Differences in CR per modified Response Evaluation Criteria in Solid Tumors were assessed by univariate and multivariate analyses for tumor size, number, location, particles size, and use of TFVDS. RESULTS: Median imaging follow-up was 20.1 months (2-33). Use of TFVDS (13 patients, 19 tumors) was the only factor predictive of CR (OR = 3.85 [CI95%: 1.09, 13.67], p = 0.04) on univariate analysis but not on multivariate analysis (OR = 3.26 [0.87, 12.23], p = 0.08). A higher rate of CR was observed for HAE using TFVDS guidance versus 2D imaging alone (68.4%, 13-19, vs. 36%, 9-25, p = 0.03). Median dose area product was lower when TFVDS was used (149.7 Gy.cm2, 38-365, vs. 227.8 Gy.cm2, 85.3-468.6, p = 0.05). CONCLUSIONS: HCC embolized with TFVDS may result in improved local tumor response without increasing the dose exposure.


Assuntos
Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Artéria Hepática/fisiopatologia , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/terapia , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/irrigação sanguínea , Carcinoma Hepatocelular/diagnóstico por imagem , Feminino , Seguimentos , Artéria Hepática/diagnóstico por imagem , Humanos , Neoplasias Hepáticas/irrigação sanguínea , Neoplasias Hepáticas/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Radiografia Intervencionista/métodos , Resultado do Tratamento
5.
Diagn Interv Imaging ; 98(9): 609-617, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28869200

RESUMO

Focal treatment with radiofrequency, microwave and cryoablation has been increasingly used for the treatment of tumors in patients who cannot undergo surgical resection and in select patients with early stage or oligometastatic disease. Each of these ablation modalities has a unique working principle and biophysics underlying the ablative effect, which largely determines the clinical indication for its application. Irreversible electroporation, a relatively new ablation technique with a predominantly nonthermal cell killing mechanism has emerged as an alternative treatment technique for tumors that are contraindicated for thermal ablation because of safety or efficacy considerations. Here, established thermal ablation techniques are compared with irreversible electroporation for treatment of tumors in the lung, liver, kidney and bone, and rationale is provided to guide selection of the most appropriate technique for each clinical setting.


Assuntos
Técnicas de Ablação/métodos , Eletroporação , Neoplasias/cirurgia , Humanos , Neoplasias/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...