1.
Clin Chem ; 64(9): 1294, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30154197
2.
J Appl Lab Med ; 3(2): 231-239, 2018 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-33636933

RESUMO

BACKGROUND: Serum thyroid-stimulating hormone (TSH) reference intervals are dependent on population characteristics, including prevalent thyroid disease and iodine status. Studies in the US have demonstrated increasing TSH levels with age, and the American Thyroid Association recommends higher TSH goals for older patients taking thyroid supplementation, but few laboratories offer age-specific reference intervals for TSH. Our objective was to establish TSH reference ranges in our racially diverse population in northern California. METHODS: Data mining of electronic medical records was used with the a posteriori approach to select a euthyroid reference population for TSH reference intervals. A report gathered all TSH results from 2 weeks from >1 year in the past, excluding results from patients with thyroid-related disease or medication use at any time before or after the TSH test. RESULTS: The reference population numbered 33038 and consisted of approximately 44% of the total TSH results reported in the selected time periods. The population identified as 46.5% white, 18.3% Asian, 17.0% Hispanic/Latino, 8.0% black/African American, and 10.3% other or unknown. These data demonstrate an increase in the median and 97.5 percentile of TSH levels with increasing age in adults. No clinically significant difference was seen between female and male individuals or between the self-identified races, except for lower TSH levels in the black/African American population. CONCLUSIONS: The a posteriori approach using data mining for disease-specific criteria proved to be an efficient method for obtaining a large healthy reference population. Age-specific TSH reference ranges could prevent inappropriate diagnoses of subclinical hypothyroidism in older patients.

3.
Clin Chem ; 63(5): 962, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28455302
4.
J Appl Lab Med ; 2(1): 76-85, 2017 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-33636957

RESUMO

BACKGROUND: Efficient tools are needed to stage liver disease before treatment of patients infected with hepatitis C virus (HCV). Compared to biopsy, several studies demonstrated favorable performance of noninvasive multianalyte serum fibrosis marker panels [fibrosis-4 (FIB-4) index] and aspartate aminotransferase (AST)-to-platelet ratio index (APRI), but suggested cutoffs vary widely. Our objective was to evaluate FIB-4 index and APRI and their component tests for staging fibrosis in our HCV-infected population and to determine practical cutoffs to help triage an influx of patients requiring treatment. METHODS: Transient elastography (TE) results from 1731 HCV-infected patients were mapped to an F0-F4 equivalent scale. Each patient's APRI and FIB-4 index were calculated. Areas under the receiver operator curve (AUROCs) and false-positive and false-negative rates were calculated to retrospectively compare the performance of the indices and their component tests. RESULTS: The highest AUROCs for distinguishing severe (F3-F4) from mild-to-moderate (F0-F2) fibrosis had overlapping 95% CIs: APRI (0.77; 0.74-0.79), FIB-4 index (0.76; 0.73-0.78), and AST (0.74; 0.72-0.77). Cutoffs had false-negative rates of 2.7%-2.8% and false-positive rates of 6.4%-7.4% for all 3 markers. CONCLUSIONS: AST was as effective as FIB-4 index and APRI at predicting fibrosis. Published cutoffs for APRI and FIB-4 index would have been inappropriate in our population, with false-negative rates as high as 11%. For our purposes, no serum fibrosis marker was sufficiently sensitive to rule-out significant fibrosis, but cutoffs developed for AST, FIB-4 index, and APRI all had specificities of 79.2%-80.3% for ruling-in severe fibrosis and could be used to triage 1/3 of our population for treatment without waiting for TE or liver biopsy.

5.
Clin Toxicol (Phila) ; 54(5): 424-7, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26942940

RESUMO

INTRODUCTION: Carbamazepine (CBZ) overdose can result in significant neurologic and cardiovascular toxicity, and is compounded by the presence of an active metabolite, carbamazepine-10,11-epoxide (CBZE). Existing publications describing continuous venovenous hemofiltration (CVVH) in CBZ overdose are limited in their ability to calculate accurate clearances. We report a case of CBZ overdose treated with CVVH with detailed measurement of CBZ, CBZE and their respective clearances calculated utilizing serial effluent measurements. This was coupled with serum level determinations comparing two analytical methodologies, time-of-flight mass spectroscopy and an immunoassay. CASE DETAILS: A 41-year-old woman presented unresponsive after an overdose of CBZ. Initial CBZ serum levels were markedly elevated (57.8 µg/mL) and continued to rise. Due to continued hemodynamic instability, extracorporeal removal was initiated using CVVH. MATERIALS AND METHODS: During the first 30 h of CVVH, interval serum samples and all ultrafiltrate bags were collected and analyzed. Serum and effluent levels of CBZ and CBZE were measured using an Agilent 6230 time-of-flight high-resolution mass spectrometer (TOF-MS). CBZ levels were also obtained utilizing the Microgenics CEDIA Carbamazepine Immunoassay (Thermo Fisher, Waltham, MA) for serum and effluent samples. Immunoassay analysis was performed using Siemens ADVIA 1800 instrument. RESULTS: The clearances achieved for CBZE (mean = 25.2, range 17.7-42.6 mL/min) exceeded that for CBZ (mean = 18.1, range 12.7-28.7 mL/min). CVVH removed a total of 1293 and 1261 mg of CBZ and CBZE, respectively. Serum levels of CBZ measured by immunoassay when compared with TOF-MS indicated cross reactivity of CBZE with the immunoassay. CONCLUSIONS: CVVH removed CBZE with higher clearances than CBZ. However, CVVH clearance rates for both CBZ and CBZE were lower than published clearances of CBZ and CBZE by intermittent hemodialysis. Our methodology allowed for a precise pharmacokinetic assessment of clearance based on total quantity of parent drug and active metabolite removed. Use of an immunoassay to determine CBZ serum levels reflects both parent compound and active metabolite due to cross-reactivity with CBZE.


Assuntos
Anticonvulsivantes/sangue , Carbamazepina/análogos & derivados , Carbamazepina/sangue , Overdose de Drogas/sangue , Hemofiltração/métodos , Adulto , Anticonvulsivantes/intoxicação , Carbamazepina/intoxicação , Cromatografia Líquida de Alta Pressão , Overdose de Drogas/terapia , Feminino , Humanos , Taxa de Depuração Metabólica , Diálise Renal , Resultado do Tratamento
7.
Clin Chim Acta ; 439: 61-7, 2015 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-25283872

RESUMO

BACKGROUND: Beckman Coulter recently released the first commercially available hCG reagent calibrated against the 5th International Standard (IS) for hCG (total ßhCG (5th IS)). We performed a comprehensive analytical validation of this reagent. METHODS: Precision experiments were completed using 3 concentrations of commercial quality control material. Linearity, sample stability, and analytical sensitivity were evaluated using pools of human serum. Reportable range was assessed by comparing manual dilutions to those performed by the instrument. Male and female reference intervals were established using residual serum specimens submitted for routine testing. Inter-lot variability of hCG assay reagent was assessed by analyzing serum specimens with detectable hCG using 2 different reagent lots. Inter-assay variability was established using 203 serum specimens analyzed for hCG on 6 different reagent platforms. RESULTS: Inter-day precision showed a CV of <6.0% for all concentrations of QC material. LOB, LOD, and LOQ were determined to be 0.3, 0.4, and 0.6 U/l, respectively. The Access (5th IS) reagent has an average positive bias of approximately 20% when compared to most platforms and the previous generation Beckman hCG assay. Results were consistent between lots. Female reference intervals varied by age: <1.0 U/l (<41 y), <6.0 U/l (41-50 y), and <8.0 U/l (>50 y). Male reference intervals were <2.0 U/l. CONCLUSIONS: The analytical performance of the total ßhCG (5th IS) was established. Care should be taken to re-baseline patients needing serial monitoring and/or notify physicians when transitioning to the total ßhCG (5th IS) reagent.


Assuntos
Gonadotropina Coriônica Humana Subunidade beta/sangue , Imunoensaio , Adulto , Gonadotropina Coriônica Humana Subunidade beta/normas , Feminino , Humanos , Imunoensaio/normas , Masculino , Pessoa de Meia-Idade , Valores de Referência
8.
Clin Biochem ; 48(4-5): 268-74, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25464016

RESUMO

BACKGROUND: Beckman Coulter has recently introduced a new troponin assay manufactured for the Access2 and DxI platforms, releasing it under the name AccuTnI+3. Clinical laboratories are required to validate method performance before testing and reporting patient results. METHODS: Beckman Coulter Access 2 instruments (n=42) across Kaiser Permanente Northern California were evaluated for their performance characteristics using the AccuTnI+3 reagent. Precision, linearity, and patient sample comparisons were performed on each instrument. Limit of the blank (LOB), limit of detection (LOD), limit of quantitation (LOQ), serum plasma comparisons, and specimen stability were evaluated using a single instrument. RESULTS: The assay was linear from 0-100,000ng/L. The LOB, LOD and LOQ were determined to be 5, 8 and 20ng/L, respectively. Interday precision on the low QC (mean concentration 41ng/L) ranged from 3.0% to 14.2%. The bias observed between the former assay (AccuTnI) and the AccuTnI+3 was comparable to the inter-instrument bias for either assay. Non-uniform distribution was observed in the precision and inter-instrument/inter-assay comparisons among the instruments evaluated. CONCLUSIONS: The AccuTnI and AccuTnI+3 troponin assays are equivalent across the analytical measuring range. There was no significant difference at the medical decision point. No changes in patient results are anticipated. However, the assay-independent inter-instrument bias observed is an important consideration for harmonization efforts.


Assuntos
Bioensaio/normas , Técnicas de Laboratório Clínico/normas , Prestação Integrada de Cuidados de Saúde/normas , Troponina I/sangue , Bioensaio/métodos , Biomarcadores/sangue , Técnicas de Laboratório Clínico/métodos , Prestação Integrada de Cuidados de Saúde/métodos , Humanos , Limite de Detecção
9.
J Clin Endocrinol Metab ; 99(4): 1171-9, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24423284

RESUMO

CONTEXT: An index case of a clinically euthyroid woman of South Asian descent was identified with discordant TSH results: undetectable TSH on our routine assay and normal TSH on an alternate assay. Low TSH concentrations due to functionally compromising TSH mutations have been reported. Here we describe a new phenomenon of functional TSH that is undetectable by 4 widely used US Food and Drug Administration (FDA)-approved TSH immunoassays marketed by a single vendor. OBJECTIVE: The purpose of this study was to identify additional cases and investigate the cause of the falsely undetectable TSH. DESIGN: All samples with TSH results of <0.01 µIU/mL were retested with a second TSH assay. Discordant samples were evaluated on up to 8 FDA-approved TSH immunoassays and the TSHß gene was sequenced. Retrospectively, thyroid function tests, diagnoses, and medications from 1.6 million individuals were analyzed. RESULTS: Out of approximately 2 million individuals, we have identified a cohort of 20 hypothyroid and euthyroid patients of shared ethnicity with falsely undetectable TSH (<0.01 µIU/mL) in 4 of 8 commercially available TSH assays. Half of these individuals were initially treated based on repeated falsely undetectable TSH values (7 euthyroid patients were treated with methimazole and 2 hypothyroid patients had doses of levothyroxine decreased). In all cases, a retrospective chart review revealed that clinical assessments and free T4 and total T3 results were inconsistent with the undetectable TSH results. Specific antibodies failing to detect TSH in these cases were identified in the 4 affected assays. A novel TSHß point mutation was identified. CONCLUSIONS: Our data suggest that these individuals have a previously unrecognized, functionally normal, TSH variant to which some monoclonal antibodies fail to bind. To assure appropriate patient management, clinicians and laboratorians need to be aware that certain TSH variants may be undetectable in some hyperselective TSH assays.


Assuntos
Erros de Diagnóstico , Hipotireoidismo/diagnóstico , Tireotropina/sangue , Adulto , Idoso , Povo Asiático/estatística & dados numéricos , California/epidemiologia , Estudos de Coortes , Erros de Diagnóstico/estatística & dados numéricos , Reações Falso-Negativas , Feminino , Humanos , Hipotireoidismo/sangue , Hipotireoidismo/epidemiologia , Imunoensaio/normas , Imunoensaio/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Testes de Função Tireóidea/normas , Testes de Função Tireóidea/estatística & dados numéricos , Adulto Jovem
12.
J Lipid Res ; 46(5): 862-71, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15716578

RESUMO

We previously demonstrated that cholesterol deprivation increases endothelial cyclooxygenase-2 (COX-2)-dependent prostacyclin [prostaglandin I2 (PGI2)] production in vitro. Cholesterol directly regulates gene transcription through the sterol response element binding protein (SREBP). In this work, we demonstrate that SREBP directly regulates COX-2 expression. Cholesterol reduces human COX-2 promoter-luciferase reporter construct activity in transiently transfected endothelial cells. Conversely, cotransfection with a constitutively active mutant SREBP increases COX-2 promoter activity. SREBP-1a and -2 specifically bind a putative sterol response element (SRE) sequence in the COX-2 promoter. This sequence competes for SREBP binding to a low density lipoprotein receptor consensus sequence in an electromobility-shift assay. These data indicate that endothelial COX-2 is regulated by cholesterol via the SREBP pathway. The present study identifies COX-2 as the first vascular gene without a clear role in lipid metabolism transactivated by SREBP, and suggests that enhanced production of PGI2 through this pathway may be an additional benefit of cholesterol-lowering therapies.


Assuntos
Proteínas Estimuladoras de Ligação a CCAAT/fisiologia , Proteínas de Ligação a DNA/fisiologia , Endotélio Vascular/enzimologia , Regulação Enzimológica da Expressão Gênica/fisiologia , Prostaglandina-Endoperóxido Sintases/genética , Fatores de Transcrição/fisiologia , Animais , Sequência de Bases , Bovinos , Células Cultivadas , Ciclo-Oxigenase 2 , Primers do DNA , Endotélio Vascular/citologia , Endotélio Vascular/efeitos dos fármacos , Endotélio Vascular/metabolismo , Epoprostenol/biossíntese , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/farmacologia , Lovastatina/farmacologia , Proteínas de Membrana , Regiões Promotoras Genéticas , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Proteína de Ligação a Elemento Regulador de Esterol 1 , Proteína de Ligação a Elemento Regulador de Esterol 2
13.
Circ Res ; 95(3): 269-75, 2004 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-15217907

RESUMO

To investigate the molecular mechanisms involved in the estrogen-dependent control of plasminogen activator inhibitor-1 (PAI-1) gene expression in vascular cells, we compared the transactivation properties of estrogen receptors (ERalpha and ERbeta) in regulating the activity of a human PAI-1 promoter reporter construct in transfected bovine aortic endothelial cells (BAECs). ERalpha increased PAI-1 promoter activity in BAECs by an estrogen-dependent mechanism, whereas ERbeta suppressed PAI-1 promoter activity by an estrogen-independent mechanism. The suppressive activity of ERbeta was dominant over the inductive activity of ERalpha. Mutation of a putative estrogen response element (ERE) located at position -427 in the proximal promoter abolished the ERalpha action without influencing the suppressive effects of ERbeta. Mutation of either AP1-like site did not eliminate the ERalpha or ERbeta actions at the PAI-1 promoter, suggesting that other promoter elements are involved in these responses. These mutations significantly reduced the -3.4kbp PAI-1 promoter response to serum. We concluded that ERalpha and ERbeta exert differential effects on the PAI-1 promoter activity in transfected BAECs. ERalpha activated the PAI-1 promoter through a proximal ERE (-427) and possibly additional EREs located within the PAI-1 promoter, whereas ERbeta suppressed the promoter construct via an unidentified mechanism. This is the first demonstration of the differential regulation of a vascular gene promoter by ERalpha and ERbeta.


Assuntos
Células Endoteliais/metabolismo , Endotélio Vascular/metabolismo , Receptor alfa de Estrogênio/fisiologia , Receptor beta de Estrogênio/fisiologia , Inibidor 1 de Ativador de Plasminogênio/genética , Regiões Promotoras Genéticas/genética , Ativação Transcricional , Animais , Aorta/citologia , Sítios de Ligação/genética , Bovinos , Células Cultivadas/metabolismo , Sequência Consenso , Ensaio de Desvio de Mobilidade Eletroforética , Endotélio Vascular/citologia , Moduladores de Receptor Estrogênico/farmacologia , Receptor alfa de Estrogênio/efeitos dos fármacos , Receptor beta de Estrogênio/efeitos dos fármacos , Estrogênios/farmacologia , Mutagênese Sítio-Dirigida , Inibidor 1 de Ativador de Plasminogênio/biossíntese , Regiões Promotoras Genéticas/efeitos dos fármacos , Proteínas Recombinantes de Fusão/fisiologia , Sequências Reguladoras de Ácido Nucleico/efeitos dos fármacos , Tamoxifeno/farmacologia , Fator de Transcrição AP-1/fisiologia , Ativação Transcricional/efeitos dos fármacos , Transfecção