1.
Appl Radiat Isot ; 205: 111160, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38171076

RESUMO

Source strength measurements are of critical importance for brachytherapy and are often performed in hospitals using well-type chambers. Quality assurance and quality control procedures should be implemented, but that may prove difficult in some hospitals due to the lack of equipment or metrological support. A study was conducted to investigate the status of the measurement equipment in Serbian hospitals and to organize an intercomparison campaign using a hospital 192Ir source. All the hospitals were able to measure the source strength with the required accuracy, but the quality assurance can be improved. Two hospitals performed stability checks, which were evaluated. Uncertainty budget was created during the exercise and is presented in this paper. The described methodology can be used to quickly assess the performance of brachytherapy centers, and can be easily adapted to calibration procedure.


Assuntos
Braquiterapia , Braquiterapia/métodos , Sérvia , Dosagem Radioterapêutica , Controle de Qualidade , Calibragem , Radiometria/métodos , Radioisótopos de Irídio
2.
Medicina (Kaunas) ; 58(6)2022 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-35744008

RESUMO

Background and Objectives: Reducing time of treatment during COVID-19 outbreaks has been recommended by the leading Radiation Oncology societies. Still minimizing radiation induced tissue toxicity is one of the most important issues in breast cancer patients. The study aimed to investigate compliance, clinical and dosimetry normal tissue toxicity, and cosmetic results between moderated and ultra-fractionated regimes for breast cancer patients during COVID-19 pandemic. Materials and Methods: This pilot prospective randomized study included 60 patients with early breast cancer after preserving surgery, 27 patients advocated to ultra-hypofractionated whole-breast three dimensional (3D) conformal radiotherapy of 26 Gy in 5 fractions over 1 week and 33 patients with moderate fractionated breast 3D conformal radiotherapy patients between March 2020 and July 2020, during the COVID pandemic outbreak. The compliance to treatment, dosimetric parameters, acute and late skin toxicity, subcutaneous tissue toxicity, cosmetic results and clinical follow up for 18 months for the two regimes were analyzed and compared. Results: When two regimes were compared 5 fraction group had significantly lower prevalence of newly infected cases of SARS-CoV-2 and thus delayed/interrupted treatment (p = 0.05), comparable grade 1 CTCAE v5, acute skin toxicity (p = 0.18), Grade 1 Radiation Morbidity Scoring Scheme (RESS) subcutaneous tissue toxicity (p = 0.18), Grade 1 RESS late skin toxicity (p = 0.88) and cosmetic results (p = 0.46). Dosimetric results reveled that patients in 5 fraction group received significantly lower median ipsilateral lung doses (p < 0.01) in addition to left breast cancer patients that received significantly lower median heart dose (p < 0.01) and median left anterior descending artery (LAD) dose (p < 0.01). Conclusion: Ultra-hypofractionated radiotherapy for breast cancer is comparable to moderate hypofractionation regimen regarding grade 1 acute skin toxicity, grade 1 subcutaneous tissue toxicity, late skin toxicity and cosmetic results. Application of ultra-hypofractionated radiotherapy with significantly lower radiation doses for lung and heart could be crucial in reducing the risk of acute/late pulmonary and heart radiation-induced toxicity.


Assuntos
Neoplasias da Mama , COVID-19 , Lesões por Radiação , Radioterapia Conformacional , Neoplasias da Mama/epidemiologia , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Feminino , Humanos , Pandemias , Estudos Prospectivos , Radioterapia Conformacional/efeitos adversos , Radioterapia Conformacional/métodos , SARS-CoV-2
3.
Radiother Oncol ; 170: 89-94, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35189156

RESUMO

PURPOSE: To update the 2011 ESTRO-EFOMP core curriculum (CC) for education and training of medical physics experts (MPE)s working in radiotherapy (RT), in line with recent EU guidelines, and to provide a framework for European countries to develop their own curriculum. MATERIAL AND METHODS: Since September 2019, 27 European MPEs representing ESTRO, EFOMP and National Societies, with expertise covering all subfields of RT physics, have revised the CC for recent advances in RT. The ESTRO and EFOMP Education Councils, all European National Societies and international stakeholders have been involved in the revision process. RESULTS: A 4-year training period has been proposed, with a total of 240 ECTS (European Credit Transfer and Accumulation System). Training entrance levels have been defined ensuring the necessary physics and mathematics background. The concept of competency-based education has been reinforced by introducing the CanMEDS role framework. The updated CC includes (ablative) stereotactic-, MR-guided- and adaptive RT, particle therapy, advanced automation, complex quantitative data analysis (big data/artificial intelligence), use of biological images, and personalized treatments. Due to the continuously increasing RT complexity, more emphasis has been given to quality management. Clear requirements for a research project ensure a proper preparation of MPE residents for their central role in science and innovation in RT. CONCLUSION: This updated, 3rd edition of the CC provides an MPE training framework for safe and effective practice of modern RT, while acknowledging the significant efforts needed in some countries to reach this level. The CC can contribute to further harmonization of MPE training in Europe.


Assuntos
Inteligência Artificial , Radioterapia (Especialidade) , Currículo , Europa (Continente) , Física Médica/educação , Humanos , Radioterapia (Especialidade)/educação
4.
Phys Med ; 91: 117-120, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34773831

RESUMO

INTRODUCTION: Sentinel node biopsy is a procedure used for axillary nodal staging in breast cancer surgery. The process uses radioactive 99mTc isotope for mapping the sentinel node(s) and all the staff involved in the procedure is potentially exposed to ionizing radiation. The colloid for radiolabelling (antimone-sulphide) with 99mTc isotope (half-life 6 h) is injected into the patient breast. The injection has activity of 18.5 MBq. The surgeon removes the primary tumor and detects active lymph nodes with gamma detection unit. The tumor as well as the active nodal tissue is transferred to pathologist for the definitive findings. The aim of the study was to measure dose equivalents to extremities and whole body for all staff and suggest practice improvement in order to minimize exposure risk. MATERIALS AND METHODS: The measurements of the following operational quantities were performed: Hp(10) personal dose equivalent to whole body and Hp(0.07) to extremities for staff as well as ambiental dose for operating theatre and during injection. Hp(0.07) were measured at surgeon's finger by ring thermoluminescent dosimeter (TLD) type MTS-N, and reader RADOS RE2000. Surgeon and nurse were wearing TLD personal dosimeter at the chest level. Anesthesiologist and anesthetist were wearing electronic personal dosimeters, while pathologist was wearing ring TLD while manipulating tissue samples. Electronic dosimeters used were manufactured by Polimaster, type PM1610. All TLD and electronic dosimeters data were reported, including background radiation. Background radiation was also monitored separately. Personal TLDs are standard for this type of personal monitoring, provided by accredited laboratory. Measurements of ambiental dose in workplaces of other staff involved around the patient was performed before the surgery took place, by calibrated survey meters manufactured by Atomtex, type 1667. The study involved two surgeons and one pathologist, two anesthesiologists and three anesthetists during two months period. RESULTS AND DISCUSSION: The doses received by all staff are evaluated using passive and active personal dosimeters and ambiental dose monitors and practice was improved based on results collected. Average annual whole body dose for all staff involved in the procedure was less than 0.8 mSv. Extremity dose equivalents to surgeon and pathologist were far below the limits set for professionally exposed (surgeon) and for public (pathologist). CONCLUSIONS: Although has proven to be very safe for all staff, additional measures for radiation protection, in accordance to ALARA principle (As Low As Reasonably Achievable) should be conducted. The recommendations for practice improvement with respect to radiation protection were issued.


Assuntos
Exposição Ocupacional , Proteção Radiológica , Humanos , Exposição Ocupacional/análise , Doses de Radiação , Compostos Radiofarmacêuticos , Biópsia de Linfonodo Sentinela
5.
Phys Med ; 84: 65-71, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33862451

RESUMO

PURPOSE: ESTRO-EFOMP intend to update the core curriculum (CC) for education and training of medical physicists in radiotherapy in line with the European Commission (EC) guidelines on Medical Physics Experts (MPE), the CanMEDS methodology and recent developments in radiotherapy. As input, a survey of the current structure of radiotherapy MPE national training schemes (NTS) in Europe was carried out. METHODS: A 35-question survey was sent to all European medical physics national societies (NS) with a focus on existence of an NTS, its format and duration, required entry-level education, and financial support for trainees. RESULTS: Twenty-six of 36 NS responded. Twenty had an NTS. Minimum required pre-training education varied from BSc in physics or related sciences (5/2) to MSc in medical physics, physics or related sciences (6/5/2) with 50-210 ECTS in fundamental physics and mathematics. The training period varied from 1 to 5 years (median 3 years with 50% dedicated to radiotherapy). The ratio of time spent on university lectures versus hospital training was most commonly 25%/75%. In 14 of 20 countries with an NTS, a research project was mandatory. Residents were paid in 17 of 20 countries. The recognition was mostly obtained by examination. Medical physics is recognised as a healthcare profession in 19 of 26 countries. CONCLUSIONS: The NTS entrance level, duration and curriculum showed significant variations. This survey serves to inform the design of the updated CC to define a realistic minimum training level for safe and effective practice aiming at further harmonization in line with EC guidelines.


Assuntos
Radioterapia (Especialidade) , Currículo , Escolaridade , Europa (Continente) , Física Médica , Humanos
6.
Acta Oncol ; 53(5): 628-36, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24164104

RESUMO

BACKGROUND AND PURPOSE: One of the newer audit modalities operated by the International Atomic Energy Agency (IAEA) involves audits of treatment planning systems (TPS) in radiotherapy. The main focus of the audit is the dosimetry verification of the delivery of a radiation treatment plan for three-dimensional (3D) conformal radiotherapy using high energy photon beams. The audit has been carried out in eight European countries - Estonia, Hungary, Latvia, Lithuania, Serbia, Slovakia, Poland and Portugal. The corresponding results are presented. MATERIAL AND METHODS: The TPS audit reviews the dosimetry, treatment planning and radiotherapy delivery processes using the 'end-to-end' approach, i.e. following the pathway similar to that of the patient, through imaging, treatment planning and dose delivery. The audit is implemented at the national level with IAEA assistance. The national counterparts conduct the TPS audit at local radiotherapy centres through on-site visits. TPS calculated doses are compared with ion chamber measurements performed in an anthropomorphic phantom for eight test cases per algorithm/beam. A set of pre-defined agreement criteria is used to analyse the performance of TPSs. RESULTS: TPS audit was carried out in 60 radiotherapy centres. In total, 190 data sets (combination of algorithm and beam quality) have been collected and reviewed. Dosimetry problems requiring interventions were discovered in about 10% of datasets. In addition, suboptimal beam modelling in TPSs was discovered in a number of cases. CONCLUSIONS: The TPS audit project using the IAEA methodology has verified the treatment planning system calculations for 3D conformal radiotherapy in a group of radiotherapy centres in Europe. It contributed to achieving better understanding of the performance of TPSs and helped to resolve issues related to imaging, dosimetry and treatment planning.


Assuntos
Garantia da Qualidade dos Cuidados de Saúde , Radiometria/normas , Planejamento da Radioterapia Assistida por Computador/normas , Radioterapia Conformacional/normas , Europa (Continente) , Humanos , Agências Internacionais , Auditoria Médica
7.
Vojnosanit Pregl ; 70(8): 735-9, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24069821

RESUMO

BACKGROUND/AIM: Development of imaging techniques, computed tomography (CT), magnetic resonance imaging (MRI), and positron emission tomography (PET), made great impact on radiotherapy treatment planning by improving the localization of target volumes. Improved localization allows better local control of tumor volumes, but also minimizes geographical misses. Mutual information is obtained by registration and fusion of images achieved manually or automatically. The aim of this study was to validate the CT-MRI image fusion method and compare delineation obtained by CT versus CT-MRI image fusion. METHODS: The image fusion software (XIO CMS 4.50.0) was applied to delineate 16 patients. The patients were scanned on CT and MRI in the treatment position within an immobilization device before the initial treatment. The gross tumor volume (GTV) and clinical target volume (CTV) were delineated on CT alone and on CT+MRI images consecutively and image fusion was obtained. RESULTS: Image fusion showed that CTV delineated on a CT image study set is mainly inadequate for treatment planning, in comparison with CTV delineated on CT-MRI fused image study set. Fusion of different modalities enables the most accurate target volume delineation. CONCLUSION: This study shows that registration and image fusion allows precise target localization in terms of GTV and CTV and local disease control.


Assuntos
Neoplasias Encefálicas , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia/métodos , Neoplasias Encefálicas/patologia , Neoplasias Encefálicas/radioterapia , Pesquisa Comparativa da Efetividade , Humanos , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Carga Tumoral
8.
Srp Arh Celok Lek ; 141(5-6): 375-9, 2013.
Artigo em Sérvio | MEDLINE | ID: mdl-23858811

RESUMO

INTRODUCTION: Rhabdomyosarcoma (RMS) is the most common sarcoma of the soft tissue, mostly affecting the region of head and neck (orbit, paranasal sinus). Histological types include embryonal (66-70%) with better prognosis, and alveolar type (20%) with poorer prognosis. There are also diffuse anaplastic and undifferentiated sarcomas (10%). Due to multimodal therapy approach (surgery, chemotherapy and radiotherapy), RMS survival rate is considerably improving. Nevertheless, early diagnosis of RMS is of crucial importance for the outcome of treatment. Standard conformal radiation therapy is very complex due to closeness of many critical structures of head and neck, thus limiting optimal tumor dose coverage. CASE OUTLINE: Patient aged 59 years, surgically treated for RMS of nasal cavity several times before radiation therapy treatment. Due to relapse, patient was re-operated, when subtotal re-resection of the maxilla with exenteration of the right orbit was done. The patient received IV cycles of polychemotherapy postoperatively. Standard procedure and planning for conformal radiation therapy did not lead to acceptable irradiation plan, and hence modification in the patient's preparation was done, resulting in optimal therapeutic plan according to internationally recognized recommendations. CONCLUSION: The reported case shows a rare pediatric tumor, which often occurs in children but extremely rare in adults. The problem of inadequate isodose distribution obtained by standard conformal plan was solved by placing bolus material into the orbital cavity.The outcome of the treatment plan showed much better isodose distribution and tumor bed coverage.


Assuntos
Evisceração do Olho/métodos , Recidiva Local de Neoplasia , Neoplasias Orbitárias/radioterapia , Radioterapia Conformacional/métodos , Rabdomiossarcoma , Quimiorradioterapia Adjuvante/métodos , Terapia Combinada , Relação Dose-Resposta à Radiação , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Nasais/efeitos adversos , Procedimentos Cirúrgicos Nasais/métodos , Recidiva Local de Neoplasia/patologia , Recidiva Local de Neoplasia/radioterapia , Recidiva Local de Neoplasia/cirurgia , Neoplasias Nasais/patologia , Neoplasias Nasais/cirurgia , Neoplasias Orbitárias/patologia , Neoplasias Orbitárias/cirurgia , Reoperação , Rabdomiossarcoma/patologia , Rabdomiossarcoma/radioterapia , Rabdomiossarcoma/cirurgia , Resultado do Tratamento
9.
Radiat Oncol ; 7: 155, 2012 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-22971539

RESUMO

BACKGROUND: Independent external audits play an important role in quality assurance programme in radiation oncology. The audit supported by the IAEA in Serbia was designed to review the whole chain of activities in 3D conformal radiotherapy (3D-CRT) workflow, from patient data acquisition to treatment planning and dose delivery. The audit was based on the IAEA recommendations and focused on dosimetry part of the treatment planning and delivery processes. METHODS: The audit was conducted in three radiotherapy departments of Serbia. An anthropomorphic phantom was scanned with a computed tomography unit (CT) and treatment plans for eight different test cases involving various beam configurations suggested by the IAEA were prepared on local treatment planning systems (TPSs). The phantom was irradiated following the treatment plans for these test cases and doses in specific points were measured with an ionization chamber. The differences between the measured and calculated doses were reported. RESULTS: The measurements were conducted for different photon beam energies and TPS calculation algorithms. The deviation between the measured and calculated values for all test cases made with advanced algorithms were within the agreement criteria, while the larger deviations were observed for simpler algorithms. The number of measurements with results outside the agreement criteria increased with the increase of the beam energy and decreased with TPS calculation algorithm sophistication. Also, a few errors in the basic dosimetry data in TPS were detected and corrected. CONCLUSIONS: The audit helped the users to better understand the operational features and limitations of their TPSs and resulted in increased confidence in dose calculation accuracy using TPSs. The audit results indicated the shortcomings of simpler algorithms for the test cases performed and, therefore the transition to more advanced algorithms is highly desirable.


Assuntos
Algoritmos , Auditoria Clínica , Garantia da Qualidade dos Cuidados de Saúde , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Calibragem , Carcinoma/radioterapia , Humanos , Neoplasias Pulmonares/radioterapia , Estudos Multicêntricos como Assunto , Imagens de Fantasmas/normas , Radiometria/métodos , Radiometria/normas , Dosagem Radioterapêutica/normas , Planejamento da Radioterapia Assistida por Computador/normas , Radioterapia Conformacional/métodos , Radioterapia Conformacional/normas , Sérvia
10.
Rep Pract Oncol Radiother ; 17(2): 97-103, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-24377007

RESUMO

AIM: To examine the impact of beam rate on dose distribution in IMRT plans and then to evaluate agreement of calculated and measured dose distributions for various beam rate values. BACKGROUND: Accelerators used in radiotherapy utilize some beam rate modes which can shorten irradiation time and thus reduce ability of patient movement during a treatment session. This aspect should be considered in high conformal dynamic techniques. MATERIALS AND METHODS: Dose calculation was done for two different beam rates (100 MU/min and 600 MU/min) in an IMRT plan. For both, a comparison of Radiation Planning Index (RPI) and MU was conducted. Secondly, the comparison of optimal fluence maps and corresponding actual fluence maps was done. Next, actual fluence maps were measured and compared with the calculated ones. Gamma index was used for that assessment. Additionally, positions of each leaf of the MLC were controlled by home made software. RESULTS: Dose distribution obtained for lower beam rates was slightly better than for higher beam rates in terms of target coverage and risk structure protection. Lower numbers of MUs were achieved in 100 MU/min plans than in 600 MU/min plans. Actual fluence maps converted from optimal ones demonstrated more similarity in 100 MU/min plans. Better conformity of the measured maps to the calculated ones was obtained when a lower beam rate was applied. However, these differences were small. No correlation was found between quality of fluence map conversion and leaf motion accuracy. CONCLUSION: Execution of dynamic techniques is dependent on beam rate. However, these differences are minor. Analysis shows a slight superiority of a lower beam rate. It does not significantly affect treatment accuracy.

11.
Radiol Oncol ; 44(3): 199-206, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22933916

RESUMO

INTRODUCTION: Enhanced dynamic wedges (EDW) are known to increase drastically the radiation therapy treatment efficiency. This paper has the aim to compare linear array measurements of EDW with the calculations of treatment planning system (TPS) and the electronic portal imaging device (EPID) for 15 MV photon energy. MATERIALS AND METHODS: The range of different field sizes and wedge angles (for 15 MV photon beam) were measured by the linear chamber array CA 24 in Blue water phantom. The measurement conditions were applied to the calculations of the commercial treatment planning system XIO CMS v.4.2.0 using convolution algorithm. EPID measurements were done on EPID-focus distance of 100 cm, and beam parameters being the same as for CA24 measurements. RESULTS: Both depth doses and profiles were measured. EDW linear array measurements of profiles to XIO CMS TPS calculation differ around 0.5%. Profiles in non-wedged direction and open field profiles practically do not differ. Percentage depth doses (PDDs) for all EDW measurements show the difference of not more than 0.2%, while the open field PDD is almost the same as EDW PDD. Wedge factors for 60 deg wedge angle were also examined, and the difference is up to 4%. EPID to linear array differs up to 5%. CONCLUSIONS: The implementation of EDW in radiation therapy treatments provides clinicians with an effective tool for the conformal radiotherapy treatment planning. If modelling of EDW beam in TPS is done correctly, a very good agreement between measurements and calculation is obtained, but EPID cannot be used for reference measurements.

SELEÇÃO DE REFERÊNCIAS