Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 313
Filtrar
1.
JTCVS Open ; 18: 12-30, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38690415

RESUMO

Objective: Anterior mitral anular calcification, particularly in radiation heart disease, and previous valve replacement with destroyed intervalvular fibrosa are challenging for prosthesis sizing and placement. The Commando procedure with intervalvular fibrosa reconstruction permits double-valve replacement in these challenging conditions. We referenced outcomes after Commando procedures to standard double-valve replacements. Methods: From January 2011 to January 2022, 129 Commando procedures and 1191 aortic and mitral double-valve replacements were performed at the Cleveland Clinic, excluding endocarditis. Reasons for the Commando were severe calcification after radiation (n = 67), without radiation (n = 43), and others (n = 19). Commando procedures were referenced to a subset of double-valve replacements using balancing-score methods (109 pairs). Results: Between balanced groups, Commando versus double-valve replacement had higher total calcium scores (median 6140 vs 2680 HU, P = .03). Hospital outcomes were similar, including operative mortality (12/11% vs 8/7.3%, P = .35) and reoperation for bleeding (9/8.3% vs 5/4.6%, P = .28). Survival and freedom from reoperation at 5 years were 54% versus 67% (P = .33) and 87% versus 100% (P = .04), respectively. Higher calcium score was associated with lower survival after double-valve replacement but not after the Commando. The Commando procedure had lower aortic valve mean gradients at 4 years (9.4 vs 11 mm Hg, P = .04). After Commando procedures for calcification, 5-year survival was 60% and 59% with and without radiation, respectively (P = .47). Conclusions: The Commando procedure with reconstruction of the intervalvular fibrosa destroyed by mitral anular calcification, radiation, or previous surgery demonstrates acceptable outcomes similar to standard double-valve replacement. More experience and long-term outcomes are required to refine patient selection for and application of the Commando approach.

2.
J Am Coll Cardiol ; 83(15): 1431-1443, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38599719

RESUMO

This focused review highlights the latest issues in native valve infective endocarditis. Native valve disease moderately increases the risk of developing infective endocarditis. In 2023, new diagnostic criteria were published by the Duke-International Society of Cardiovascular Infectious Diseases group. New pathogens were designated as typical, and findings on computed tomography imaging were included as diagnostic criteria. It is now recognized that a multidisciplinary approach to care is vital, and the role of an "endocarditis team" is highlighted. Recent studies have suggested that a transition from intravenous to oral antibiotics in selected patients may be reasonable, and the role of long-acting antibiotics is discussed. It is also now clear that an aggressive surgical approach can be life-saving in some patients. Finally, results of several recent studies have suggested there is an association between dental and other invasive procedures and an increased risk of developing infective endocarditis. Moreover, data indicate that antibiotic prophylaxis may be effective in some scenarios.


Assuntos
Endocardite Bacteriana , Endocardite , Próteses Valvulares Cardíacas , Humanos , Endocardite/diagnóstico , Endocardite/etiologia , Endocardite Bacteriana/diagnóstico , Tomografia Computadorizada por Raios X , Antibacterianos/uso terapêutico , Antibioticoprofilaxia , Próteses Valvulares Cardíacas/efeitos adversos , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos
4.
Clin Infect Dis ; 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38466039

RESUMO

This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multi-societal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multi-focal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.

5.
Artigo em Inglês | MEDLINE | ID: mdl-38466252

RESUMO

This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multi-societal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with fluorine-18 fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multi-focal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.

6.
J Nucl Cardiol ; 34: 101786, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38472038

RESUMO

This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multi-societal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multi-focal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.


Assuntos
Infecções Cardiovasculares , Endocardite , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Fluordesoxiglucose F18 , Consenso , Tomografia Computadorizada por Raios X , Imagem Multimodal , Endocardite/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único
7.
Heart Rhythm ; 21(5): e1-e29, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38466251

RESUMO

This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multi-societal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multi-focal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.


Assuntos
Consenso , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Compostos Radiofarmacêuticos , Humanos , Fluordesoxiglucose F18/farmacologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Compostos Radiofarmacêuticos/farmacologia , Leucócitos , Estados Unidos , Infecções Cardiovasculares/diagnóstico , Sociedades Médicas , Imagem Multimodal/métodos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Endocardite/diagnóstico , Endocardite/diagnóstico por imagem
8.
JACC Case Rep ; 29(4): 102199, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38379657

RESUMO

Transcatheter aortic valve replacement is not widely used in patients with congenital heart disease. We describe our single-center experience of transcatheter aortic valve replacement in congenital heart disease, demonstrating short-term feasibility and safety, role in lifetime management of congenital aortic valve disease, and use as a bridge to recovery, future surgery, or transplantation.

9.
J Am Coll Cardiol ; 83(8): 811-823, 2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38383096

RESUMO

BACKGROUND: Persons who inject drugs and require surgery for infective endocarditis have 2 potentially lethal diseases. Current postoperative rehabilitation efforts seem ineffective in preventing loss to follow-up, injection drug use relapse (relapse), and death. OBJECTIVES: The purpose of this study was to characterize drug use, psychosocial issues, surgical outcome, and postoperative addiction management, as well as loss to follow-up, relapse, and mortality and their risk factors. METHODS: From January 2010 to June 2020, 227 persons who inject drugs, age 36 ± 9.9 years, underwent surgery for infective endocarditis at a quaternary hospital having special interest in developing addiction management programs. Postsurgery loss to follow-up, relapse, and death were assessed as competing risks and risk factors identified parametrically and by machine learning. CIs are 68% (±1 SE). RESULTS: Heroin was the most self-reported drug injected (n = 183 [81%]). Psychosocial issues included homelessness (n = 56 [25%]), justice system involvement (n = 150 [66%]), depression (n = 118 [52%]), anxiety (n = 104 [46%]), and post-traumatic stress disorder (n = 33 [15%]). Four (1.8%) died in-hospital. Medication for opioid use disorder prescribed at discharge increased from 0% in 2010 to 100% in 2020. At 1 and 5 years, conditional probabilities of loss to follow-up were 16% (68% CI: 13%-22%) and 59% (68% CI: 44%-65%), relapse 32% (68% CI: 28%-34%) and 79% (68% CI: 74%-83%), and mortality 21% (68% CI: 18%-23%) and 68% (68% CI: 62%-72%). Younger age, heroin use, and lower education level were predictors of relapse. CONCLUSIONS: Infective endocarditis surgery can be performed with low mortality in persons who inject drugs, but addiction is far more lethal. Risk of loss to follow-up and relapse require more effective addiction strategies without which this major loss to society will continue.


Assuntos
Usuários de Drogas , Endocardite Bacteriana , Endocardite , Abuso de Substâncias por Via Intravenosa , Humanos , Adulto , Pessoa de Meia-Idade , Analgésicos Opioides , Heroína , Abuso de Substâncias por Via Intravenosa/complicações , Abuso de Substâncias por Via Intravenosa/epidemiologia , Estudos Retrospectivos , Endocardite Bacteriana/etiologia , Endocardite Bacteriana/complicações , Endocardite/epidemiologia , Endocardite/etiologia , Recidiva
10.
Struct Heart ; 8(1): 100217, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38283567

RESUMO

Background: The Ozaki procedure using autologous pericardium is an interesting but complex alternative for aortic valve replacement. We present a standardized approach to minimize the learning curve and confirm reproducibility. Methods: After careful preparation, from May 2015 to February 2021, an Ozaki procedure was performed on 46 patients age 51 ± 14 years. Seven had unicuspid (15%), 29 bicuspid (63%), and 10 tricuspid (22%) aortic valves, and 2 patients had endocarditis. Endpoints were operative learning curves, perioperative outcomes, intermediate-term valve hemodynamics, reintervention, health-related quality of life (MacNew Heart Disease Health-Related Quality of Life questionnaire), and mortality. Results: Cardiopulmonary bypass and aortic clamp times decreased from 145 to 125 â€‹minutes and 120 to 100 â€‹minutes, respectively, over the first 20 cases, reflecting the learning curve. There was no major perioperative morbidity or mortality. Median postoperative stay was 6.9 days. Aortic regurgitation was mild or less in all but 2 patients who developed moderate aortic regurgitation. Mean aortic valve gradient was 7.9 mmHg postoperatively, 9.2 mmHg by 6 months, and constant thereafter. Left ventricular ejection fraction was 58% preoperatively, 60% at 6 months, and remained stable thereafter. One patient developed infective endocarditis 7 months postoperatively, failed medical management, and underwent valve replacement at 14 months. Two-year survival was 96%, with 1 noncardiac death at 16 months. Health-related quality of life in mental, physical, and emotional domains was better than matched norms, global 6.2 vs. 5.0 (p < 0.0001). Conclusions: Using a well-prepared standardized approach, the Ozaki procedure is reproducible with a short learning curve, excellent hemodynamic performance, and good quality of life.

12.
J Thorac Cardiovasc Surg ; 167(1): 127-140.e15, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-35927083

RESUMO

OBJECTIVE: The objectives of this study were to investigate patient characteristics, valve pathology, bacteriology, and surgical techniques related to outcome of patients who underwent surgery for isolated native (NVE) or prosthetic (PVE) mitral valve endocarditis. METHODS: From January 2002 to January 2020, 447 isolated mitral endocarditis operations were performed, 326 for NVE and 121 for PVE. Multivariable analysis of time-related outcomes used random forest machine learning. RESULTS: Staphylococcus aureus was the most common causative organism. Of 326 patients with NVE, 88 (27%) underwent standard mitral valve repair, 43 (13%) extended repair, and 195 (60%) valve replacement. Compared with NVE with standard repair, patients who underwent all other operations were older, had more comorbidities, worse cardiac function, and more invasive disease. Hospital mortality was 3.8% (n = 17); 0 (0%) after standard valve repair, 3 (7.0%) after extended repair, 8 (4.1%) after NVE replacement, and 6 (5.0%) after PVE re-replacement. Survival at 1, 5, and 10 years was 91%, 75%, and 62% after any repair and 86%, 62%, and 44% after replacement, respectively. The most important risk factor for mortality was renal failure. Risk-adjusted outcomes, including survival, were similar in all groups. Unadjusted extended repair outcomes, particularly early, were similar or worse than replacement in terms of reinfection, reintervention, regurgitation, gradient, and survival. CONCLUSIONS: A patient- and pathology-tailored approach to surgery for isolated mitral valve endocarditis has low mortality and excellent results. Apparent superiority of standard valve repair is related to patient characteristics and pathology. Renal failure is the most powerful risk factor. In case of extensive destruction, extended repair shows no benefit over replacement.


Assuntos
Endocardite Bacteriana , Endocardite , Infecções Relacionadas à Prótese , Insuficiência Renal , Humanos , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/cirurgia , Endocardite Bacteriana/microbiologia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Valva Mitral/microbiologia , Valva Aórtica/cirurgia , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/cirurgia , Infecções Relacionadas à Prótese/microbiologia , Endocardite/patologia , Resultado do Tratamento
13.
Artigo em Inglês | MEDLINE | ID: mdl-38058148

RESUMO

Our goal was to replace the previous composite graft with a bioprosthesis. The approach involved axillary artery and femoral vein cannulation and cardiopulmonary bypass with moderate hypothermia for re-entry of the chest and deep hypothermia with circulatory arrest to get control of and to clamp the aorta when entering the pseudoaneurysm. The myocardial protection strategy was general cooling and retrograde cardioplegia through direct coronary sinus cannulation and antegrade cardioplegia in the coronary ostia when possible. After the pseudoaneurysm was entered, the graft was divided in the middle, and the distal end was dissected out under circulatory arrest sufficiently to allow clamping and to resume systemic circulation. The graft was not dissected out beyond the previous anastomosis. Under another period of circulatory arrest, the distal graft was removed to the mid-arch, and a new graft was attached with a hemiarch anastomosis. Then the root was dissected out, and both coronary ostia were mobilized. The mechanical aortic valve and previous graft material were explanted. A new bioprosthetic valved conduit was used to replace the aortic root, and the coronary buttons were re-implanted directly in the new graft.


Assuntos
Falso Aneurisma , Aorta Torácica , Humanos , Aorta Torácica/cirurgia , Falso Aneurisma/etiologia , Falso Aneurisma/cirurgia , Aorta/cirurgia , Ponte Cardiopulmonar , Cateterismo , Reoperação
14.
Artigo em Inglês | MEDLINE | ID: mdl-38081538

RESUMO

OBJECTIVE: Patient characteristics, risks, and outcomes associated with reoperative multivalve cardiac surgery are poorly characterized. Effect of patient variables and surgical components of each reoperation were evaluated with regard to operative mortality. METHODS: From January 2008 to January 2022, 2324 patients with previous cardiac surgery underwent 2352 reoperations involving repair or replacement of multiple cardiac valves at Cleveland Clinic. Mean age was 66 ± 14 years. Number of surgical components representing surgical complexity (valve procedures, aortic surgery, coronary artery bypass grafting, and atrial fibrillation procedures) ranged from 2 to 6. Random forest for imbalanced data was used to identify risk factors for operative mortality. RESULTS: Surgery was elective in 1327 (56%), urgent in 1006 (43%), and emergency in 19 (0.8%). First-time reoperations were performed in 1796 (76%) and 556 (24%) had 2 or more previous operations. Isolated multivalve operations comprised 54% (1265) of cases; 1087 incorporated additional surgical components. Two valves were operated on in 80% (1889) of cases, 3 in 20% (461), and 4 in 0.09% (2). Operative mortality was 4.2% (98 out of 2352), with 1.7% (12 out of 704) for elective, isolated multivalve reoperations. For each added surgical component, operative mortality incrementally increased, from 2.4% for 2 components (24 out of 1009) to 17% for ≥5 (5 out of 30). Predictors of operative mortality included coronary artery bypass grafting, surgical urgency, cardiac, renal dysfunction, peripheral artery disease, New York Heart Association functional class, and anemia. CONCLUSIONS: Elective, isolated reoperative multivalve surgery can be performed with low mortality. Surgical complexity coupled with key physiologic factors can be used to inform surgical risk and decision making.

16.
Artigo em Inglês | MEDLINE | ID: mdl-37778501

RESUMO

OBJECTIVE: The study objective was to identify the effects of surgeon experience and age, in the context of cumulative institutional experience, on risk-adjusted hospital mortality after cardiac reoperations. METHODS: From 1951 to 2020, 36 surgeons performed 160,338 cardiac operations, including 32,871 reoperations. Hospital death was modeled using a novel tree-bagged, generalized varying-coefficient method with 6 variables reflecting cumulative surgeon and institutional experience up to each cardiac operation: (1) number of total and (2) reoperative cardiac operations performed by a surgeon, (3) cumulative institutional number of total and (4) reoperative cardiac operations, (5) year of surgery, and (6) surgeon age at each operation. These were adjusted for 46 patient characteristics and surgical components. RESULTS: There were 1470 hospital deaths after cardiac reoperations (4.5%). At the institutional level, hospital death decreased exponentially and became less variable, leveling at 1.2% after approximately 14,000 cardiac reoperations. For all surgeons as a group, hospital death decreased rapidly over the first 750 reoperations and then gradually decreased with increasing experience to less than 1% after approximately 4000 reoperations. Surgeon age up to 75 years was associated with ever-decreasing hospital death. CONCLUSIONS: Surgeon age and experience have been implicated in adverse surgical outcomes, particularly after complex cardiac operations, with young surgeons being novices and older surgeons having declining ability. However, at Cleveland Clinic, outcomes of cardiac reoperations improved with increasing primary surgeon experience, without any suggestion to mid-70s of an age cutoff. Patients were protected by the cumulative background of institutional experience that created a culture of safety and teamwork that mitigated adverse events after cardiac surgery.

17.
Artigo em Inglês | MEDLINE | ID: mdl-37074251

RESUMO

OBJECTIVE: To investigate outcomes after aortic root allograft reoperation, identify risk factors for morbidity and mortality, and describe practice evolution since publication of our 2006 allograft reoperation study. METHODS: From January 1987 to July 2020, 602 patients underwent 632 allograft-related reoperations at Cleveland Clinic: 144 before 2006 (early era, which suggested radical explant was superior to aortic-valve-replacement-within-allograft [AVR-only]), and 488 from 2006 to present (recent era). Indications for reoperation were structural valve deterioration in 502 (79%), infective endocarditis in 90 (14%), and nonstructural valve deterioration/noninfective endocarditis in 40 (6.3%). Reoperative techniques included radical allograft explant in 372 (59%), AVR-only in 248 (39%), and allograft preservation in 12 (1.9%). Perioperative events and survival were assessed among indications, techniques, and eras. RESULTS: Operative mortality by indication was 2.2% (n = 11) for structural valve deterioration, 7.8% (n = 7) in those with infective endocarditis, and 7.5% (n = 3) for nonstructural valve deterioration/noninfective endocarditis, and by surgical approach 2.4% (n = 9) after radical explant, 4.0% (n = 10) for AVR-only, and 17% (n = 2) for allograft preservation. Operative adverse events occurred in 4.9% (n = 18) of radical explants and 2.8% (n = 7) of AVR-only procedures (P = .2). Patients undergoing radical explants received larger valves than those undergoing AVR-only (median, 25 vs 23 mm). CONCLUSIONS: Aortic root allograft reoperations present a technical challenge but can be performed with low mortality and morbidity. Radical explant offers outcomes similar to AVR-only while allowing for implant of larger prostheses. Increasing experience with allograft reoperations has permitted excellent outcomes; thus, risk of reoperation should not dissuade surgeons from using allografts for invasive aortic valve infective endocarditis and other indications.

18.
Artigo em Inglês | MEDLINE | ID: mdl-36841346

RESUMO

We sought to couple current cardiac magnetic resonance (CMR) thresholds of right ventricular (RV) size and function with longitudinal trajectories of RV recovery, after pulmonary valve replacement (PVR). We aimed to identify optimal timing of PVR and couple CMR-based metrics with contemporaneous echocardiographic metrics. From June 2002 to January 2019, 174 patients with severe pulmonary regurgitation and peak RV outflow tract gradient <30 mm Hg underwent PVR at Cleveland Clinic. Mean age was 35 ± 16 years and 60 (34%) had concomitant tricuspid valve surgery. RV end diastolic area index (RVEDAi) and function metrics were measured by offline image review on preoperative and 794 postoperative echocardiograms. Contemporaneous RV end diastolic volume index (RVEDVi) was assessed on CMR and correlated to RVEDAi. Multiphase nonlinear mixed-effects models were used to analyze the longitudinal change in RV size and function after PVR. RVEDAi was correlated with RVEDVi (P < 0.0001, r = 0.59). RVEDAi decreased slowly over 10 years following PVR. An inflection point at 24 cm2/m2 was noted at 1 year post-PVR and was associated with failure of RV reverse remodeling and RVEDVi ≥150 mL/m2. Compared to patients with preoperative RVEDVi ≥150 mL/m2, patients with RVEDVi <150 mL/m2 had accelerated recovery of longitudinal trajectories of RV size and function metrics on echocardiograms. Reverse remodeling of RV following PVR is an ongoing process. Current accepted threshold values for PVR are associated with greatest RV recovery, suggesting that earlier PVR is warranted. Echocardiography can potentially be utilized in lieu of CMR for surveillance and interventional triage.

20.
J Am Heart Assoc ; 12(2): e027391, 2023 01 17.
Artigo em Inglês | MEDLINE | ID: mdl-36628965

RESUMO

Background We assessed the Ozaki procedure, aortic valve reconstruction using autologous pericardium, with respect to its learning curve, hemodynamic performance, and durability compared with a stented bioprosthesis. Methods and Results From January 2007 to January 2016, 776 patients underwent an Ozaki procedure at Toho University Ohashi Medical Center. Learning curves, aortic regurgitation (AR), and peak gradient, assessed by serial echocardiograms, valve rereplacement, and survival were investigated. Valve performance and durability were compared with 627 1:1 propensity-matched patients receiving stented bovine pericardial valves implanted from 1982 to 2011 at Cleveland Clinic. Learning curves were observed for aortic clamp and cardiopulmonary bypass times, AR prevalence, and early mortality. Decreased aortic clamp time was observed over the first 300 cases. New surgeons performing parts of the procedure after case 400 resulted in a slight increase in aortic clamp and cardiopulmonary bypass times. Among matched patients, the Ozaki cohort had more AR than the PERIMOUNT cohort (severe AR at 1 and 6 years, 0.58% and 3.6% versus 0.45% and 1.0%, respectively; P[trend]=0.006), although with a steep learning curve. Peak gradient showed the opposite trend: 14 and 17 mm Hg for Ozaki and 24 and 28 mm Hg for PERIMOUNT at these times (P[trend]<0.001). Freedom from rereplacement was similar (P=0.491). Survival of the Ozaki cohort was 85% at 6 years. Conclusions Patients undergoing the Ozaki procedure had lower gradients but more recurrent AR than those receiving PERIMOUNT bioprostheses. Although recurrent AR is concerning, results confirm low risk and good midterm performance of the Ozaki procedure, supporting its continued use.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Animais , Bovinos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Aórtica/cirurgia , Pericárdio/cirurgia , Hemodinâmica , Resultado do Tratamento , Estenose da Valva Aórtica/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...