Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Foods ; 13(5)2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38472862

RESUMO

In samples of Artemisia campestris (AC), Artemisia herba-alba (AHA) and Salvia jordanii (SJ) essential oils, up to 200 distinct volatile compounds were identified. Using headspace solid-phase microextraction combined with gas chromatography-olfactometry-mass spectrometry (HS-SPME-GC-O-MS), different panelists detected 52 of these compounds. This study offers the most detailed analysis of bioactive compound profiles conducted so far. The most abundant compounds identified were curcumene, making up 12.96% of AC, and camphor, constituting 21.67% of AHA and 19.15% of SJ. The compounds with the highest odor activity value (OAV) were (E,Z)-2,4-nonadienal (geranium, pungent), 3-nonenal (cucumber) and 2-undecenal (sweet) in AC, AHA and SJ, respectively. AHA essential oil showed significant antioxidant activity (IC50 = 41.73 ± 4.14 mg/g) and hydroxyl radical generation (hydroxylation percentage = 29.62 ± 3.14), as assessed by the diphenylpicrylhydrazyl (DPPH) method. In terms of oxygen radical absorbance capacity (ORAC), the strongest antioxidant activity was obtained for SJ essential oil (antioxidant activity of the essential oils, AOX = 337.49 ± 9.87).

2.
Talanta ; 172: 37-44, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28602301

RESUMO

Recently oxobiodegradable polyethylene gained popularity as food packaging material due to its potential to reduce polymer waste. However, this type of material can release after its oxidation off-odour compounds that affect the organoleptic properties of packaged food. Odour compounds released from both polyethylene and oxobiodegradable polyethylene before and after oxidation under a free radicals flow were investigated after 1 day, 2 days and 3 days of oxidation. The samples were analysed using headspace solid phase microextraction followed by gas chromatography-mass spectrometry and headspace solid phase microextraction coupled to gas chromatography-olfactometry-mass spectrometry. Sixty-two different odorous compounds were identified. 4-methylthio-2-butanone (fruit), nonanal (fat) and 3,6-nonadienal (fat) were present in different materials before oxidation. Multiple headspace-solid phase microextraction has been used to quantify all analytes. The most abundant compound was (Z)-3-hexenyl hexanoate with a concentration range between 1.5791±0.1387µg/g and 4.8181±0.3123µg/g. Compounds such as 2-dodecenal, 2-octenal, 2-pentanol, 3-nonenal, 3,6-nonadienal, ethyl 3-methylbutanoate, ethyl octenoate, hexanone, isopropyl hexanoate, octanal were below their LOD evaluated using MS detector; however, they were detected by gas chromatography-olfactometry. The minimum LOD and LOQ were 0.011µg/g and 0.036µg/g, respectively.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Odorantes/análise , Olfatometria/métodos , Polietileno/química , Microextração em Fase Sólida/métodos , Embalagem de Alimentos , Radicais Livres/química , Oxirredução
3.
J Chromatogr A ; 1432: 73-83, 2016 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-26777782

RESUMO

61 different non-volatile compounds were determined in Agaricus Bisporus sliced mushrooms using UHPLC/Q-TOF with MS(E) technology. Both positive and negative electrospray ionization were applied. Chemical profile of three parts of mushroom was created: cap, gills and stipe. The analysed mushrooms were oxidized to identify the non-volatile markers in their parts. MarkerLynx(®) was proposed as a powerful tool to distinguish mushrooms purchased in different countries (Spain and Portugal) by determining their non-volatile markers. Some metabolites were identified. Surprisingly a mix of polyethylene glycols (PEGs) was detected in cap and gills of mushrooms. Whole mushrooms were considered as vegetable resistant to migration from packaging compounds. Additionally migration tests were performed to determine the source of migrating compounds.


Assuntos
Agaricus/química , Animais , Biomarcadores/análise , Cromatografia Líquida de Alta Pressão/métodos , Embalagem de Alimentos , Espectrometria de Massas/métodos , Oxirredução , Espanha
4.
Food Chem ; 141(4): 3993-9, 2013 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-23993576

RESUMO

A procedure for the determination of mineral oils in edible oil has been fully developed. The procedure consists of using a sulphuric acid-impregnated silica gel (SAISG) glass column to eliminate the fat matter. A chemical combustion of the fatty acids takes place, while the mineral oils are not affected by the sulphuric acid. The column is eluted with hexane using a vacuum pump and the final extract is concentrated and analysed by gas chromatography (GC) with flame ionisation detector (FID). The detection limit (LOD) and the quantification limit (LOQ) in hexane were 0.07 and 0.21 µg g(-1) respectively and the LOQ in vegetable oil was 1 µg g(-1). Only a few minutes were necessary for sample treatment to have a clean extract. The efficiency of the process, measured through the recoveries from spiked samples of edible oil was higher than 95%. The procedure has been applied to determine mineral oil in olive oil from the retailed market.


Assuntos
Cromatografia Gasosa/métodos , Contaminação de Alimentos/análise , Óleo Mineral/análise , Óleos de Plantas/química , Cromatografia Gasosa/instrumentação , Análise Discriminante , Limite de Detecção , Azeite de Oliva
5.
Anal Chim Acta ; 756: 49-59, 2012 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-23176739

RESUMO

Toxic primary aromatic amines (PAAs) are reaction products from residual isocyanates in polyurethane adhesives. The maximum migration level of the total sum of PAAs is 10 ng g(-1) of food. This paper reports on a method for quantification of 18 PAAs by UHPLC-MS/MS that was optimised and applied to a series of industrial laminates prepared from polyurethane adhesives. Non-intentionally added substances (NIAS), impurities and other migrants were identified by Q-TOF/MS(E). A comparison of the quantitative values obtained by the colorimetric method using NEDA and by UHPLC-MS/MS confirmed that the first method can overestimate the quantification of PAAs. This could be attributed to the impurities and other NIAS present in the plastic laminate. Values of R(2) in the analytical characteristics of UHPLC-MS/MS were obtained, the best value being 0.9964 and the most unfavourable 0.7626. The detection limit (LOD) and the quantification limit (LOQ) were 2 pg g(-1) and 7 pg g(-1), respectively. The stability of the PAAs over time in the acidic simulant in contact with the plastic laminate is also reported.


Assuntos
Adesivos/química , Aminas/análise , Contaminação de Alimentos , Poliuretanos/química , Espectrometria de Massas em Tandem , Aminas/química , Embalagem de Alimentos
6.
Anal Chim Acta ; 745: 92-8, 2012 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-22938611

RESUMO

Ethyl Lauroyl Arginate (LAE) is a cationic tensoactive compound, soluble in water, with a wide activity spectrum against moulds and bacteria. LAE has been incorporated as antimicrobial agent into packaging materials for food contact and these materials require to comply with the specific migration criteria. In this paper, one analytical procedure has been developed and optimized for the analysis of LAE in food simulants after the migrations tests. It consists of the formation of an ionic pair between LAE and the inorganic complex Co(SCN)(4)(2-) in aqueous solution, followed by a liquid-liquid extraction in a suitable organic solvent and further UV-Vis absorbance measurement. In order to evaluate possible interferences, the ionic pair has been also analyzed by high performance liquid chromatography with UV-Vis detection. Both procedures provided similar analytical characteristics, with linear ranges from 1.10 to 25.00 mg kg(-1), linearity higher than 0.9886, limits of detection and quantification of 0.33 and 1.10 mg kg(-1), respectively, accuracy better than 1% as relative error and precision better than 3.6% expressed as RSD. Optimization of analytical techniques, thermal and chemical stability of LAE, as well as migration kinetics of LAE from experimental active packaging are reported and discussed.


Assuntos
Antibacterianos/análise , Arginina/análogos & derivados , Cobalto/química , Embalagem de Alimentos , Extração Líquido-Líquido/métodos , Tiocianatos/química , Arginina/análise , Cromatografia Líquida de Alta Pressão/métodos , Cobalto/análise , Cinética , Limite de Detecção , Reprodutibilidade dos Testes , Soluções , Espectrofotometria Ultravioleta , Tiocianatos/análise , Água/química
7.
J Chromatogr A ; 1218(10): 1319-30, 2011 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-21292271

RESUMO

A method for the determination of volatile organic compounds (VOCs) in recycled polyethylene terephthalate and high-density polyethylene using headspace sampling by solid-phase microextraction and gas chromatography coupled to mass spectrometry detection is presented. This method was used to evaluate the efficiency of cleaning processes for VOC removal from recycled PET. In addition, the method was also employed to evaluate the level of VOC contamination in multilayer packaging material containing recycled HDPE material. The optimisation of the extraction procedure for volatile compounds was performed and the best extraction conditions were found using a 75 µm carboxen-polydimethylsiloxane (CAR-PDMS) fibre for 20 min at 60 °C. The validation parameters for the established method were linear range, linearity, sensitivity, precision (repeatability), accuracy (recovery) and detection and quantification limits. The results indicated that the method could easily be used in quality control for the production of recycled PET and HDPE.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Polietilenotereftalatos/química , Polietileno/química , Microextração em Fase Sólida/métodos , Compostos Orgânicos Voláteis/análise , Embalagem de Alimentos , Modelos Lineares , Reciclagem , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
J Chromatogr A ; 1216(18): 3731-9, 2009 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-19303074

RESUMO

The determination of specific migration in the three aqueous food simulants (water, 3% acetic acid and 10% ethanol) from experimental active packaging polypropylene-based films containing natural essential oils as active agents has been carried out for the first time by a two-phase hollow fibre liquid phase microextraction (HFLPME). Due to the high number of variables involved, an experimental design has been applied. High throughput, with six samples running simultaneously in a highly automated system working in dynamic extraction mode, has been achieved. The main analytical characteristics are detection limits as low as 0.01 microg kg(-1), linearity higher than 0.99 for almost 5 magnitude orders, average precision below 16% as RSD and concentration factors ranging from 4 to 189. Migration of 43 compounds including terpenes, alkanes, plastic additives and degradation compounds is reported. According to the results obtained and European legislation, the packaging prototypes tested could be safely marketed.


Assuntos
Ácido Acético/química , Etanol/química , Embalagem de Alimentos/métodos , Óleos Voláteis/química , Polipropilenos/química , Microextração em Fase Sólida/métodos , Microextração em Fase Sólida/instrumentação
9.
J Chromatogr A ; 1178(1-2): 126-33, 2008 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-18068177

RESUMO

An experimental laboratory-made assembly to determine for the first time the antioxidant capacity with respect to hydroxyl (OH*) radicals of several new active packagings directly in the materials has been developed. Gas-phase OH* radicals are generated by UV-light irradiation of an aqueous H(2)O(2) aerosol. After on-line reaction with up to eight parallel test samples, remaining OH* is quantitatively trapped by a salicylic acid solution, and antioxidant capacity is indirectly assessed by HPLC-fluorescence determination of the high sensitive 2,5-dihydroxybenzoic acid formed. Several natural essential oils as well as active plastic films including in their formulation such oils have been subjected to oxidation. Polymers containing clove and oregano were the most efficient ones (up to 7.2 and 4.7 times, respectively, more antioxidant than blanks), whereas rosemary, citronella and propolis showed average efficiency. On the other hand, active materials containing ferulic acid, quercetin, catechin and thymol, as well as commercial active bags with ethylene-absorption properties, showed limited or none antioxidant protection. Experimental results and full details about experimental assembly are given.


Assuntos
Antioxidantes , Cromatografia Líquida de Alta Pressão , Embalagem de Alimentos , Hidroxibenzoatos/análise , Radical Hidroxila/análise , Fluorescência , Óleos Voláteis/química , Oxirredução , Ácido Salicílico/química
10.
J Chromatogr A ; 1174(1-2): 85-94, 2007 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-17765253

RESUMO

A two-phase based hollow fibre liquid-phase microextraction (HFLPME) with a high automatization degree and able to process up to six samples simultaneously by means of a multiple channel syringe pump has been successfully developed. The experimental set-up allows to carry out dynamic extractions with a considerable reduction of sample handling. The system has been applied for the first time to the determination in aqueous food simulant of migrants from prototypes of active packagings to assess their safety before marketing, showing detection limits in the ng g(-1) range, relative standard deviations below 13% and concentration factors ranging from 83 to 338.


Assuntos
Técnicas de Química Analítica/métodos , Embalagem de Alimentos , Óleos Voláteis/análise , Intervalos de Confiança , Cromatografia Gasosa-Espectrometria de Massas , Concentração Osmolar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...