Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Stroke ; 50(2): 298-304, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30661490

RESUMO

Background and Purpose- We sought to explore the effect of genetic imbalance on functional outcome after ischemic stroke (IS). Methods- Copy number variation was identified in high-density single-nucleotide polymorphism microarray data of IS patients from the CADISP (Cervical Artery Dissection and Ischemic Stroke Patients) and SiGN (Stroke Genetics Network)/GISCOME (Genetics of Ischaemic Stroke Functional Outcome) networks. Genetic imbalance, defined as total number of protein-coding genes affected by copy number variations in an individual, was compared between patients with favorable (modified Rankin Scale score of 0-2) and unfavorable (modified Rankin Scale score of ≥3) outcome after 3 months. Subgroup analyses were confined to patients with imbalance affecting ohnologs-a class of dose-sensitive genes, or to those with imbalance not affecting ohnologs. The association of imbalance with outcome was analyzed by logistic regression analysis, adjusted for age, sex, stroke subtype, stroke severity, and ancestry. Results- The study sample comprised 816 CADISP patients (age 44.2±10.3 years) and 2498 SiGN/GISCOME patients (age 67.7±14.2 years). Outcome was unfavorable in 122 CADISP and 889 SiGN/GISCOME patients. Multivariate logistic regression analysis revealed that increased genetic imbalance was associated with less favorable outcome in both samples (CADISP: P=0.0007; odds ratio=0.89; 95% CI, 0.82-0.95 and SiGN/GISCOME: P=0.0036; odds ratio=0.94; 95% CI, 0.91-0.98). The association was independent of age, sex, stroke severity on admission, stroke subtype, and ancestry. On subgroup analysis, imbalance affecting ohnologs was associated with outcome (CADISP: odds ratio=0.88; 95% CI, 0.80-0.95 and SiGN/GISCOME: odds ratio=0.93; 95% CI, 0.89-0.98) whereas imbalance without ohnologs lacked such an association. Conclusions- Increased genetic imbalance was associated with poorer functional outcome after IS in both study populations. Subgroup analysis revealed that this association was driven by presence of ohnologs in the respective copy number variations, suggesting a causal role of the deleterious effects of genetic imbalance.


Assuntos
Isquemia Encefálica/genética , Dosagem de Genes , Adulto , Idoso , Isquemia Encefálica/reabilitação , Cromossomos Humanos/genética , Seguimentos , Duplicação Gênica , Genótipo , Humanos , Pessoa de Meia-Idade , Polimorfismo de Nucleotídeo Único , Recuperação de Função Fisiológica , Índice de Gravidade de Doença
2.
Adv Biochem Eng Biotechnol ; 109: 1-18, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-17992487

RESUMO

This is a first attempt at a brief sketch of the history of biosensors. It is far from complete and rather unsystematic. Many names are still missing, and we apologize for this. But the authors hope to have laid a humble cornerstone for a future "Complete History of Biosensors". We hope that many of our colleagues will contribute!


Assuntos
Técnicas Biossensoriais/história , Animais , Alemanha , História do Século XX , História do Século XXI , Humanos
3.
Analyst ; 127(8): 1076-81, 2002 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12195949

RESUMO

Both the antibody affinity and the detectability of the label are essential in deciding the final characteristics of a heterogeneous immunoassay. This paper describes an approach to obtain a supplementary enhancement of the signal generated by using an enzyme label, e.g., by including the product of the enzymatic reaction in an additional amplification cycle during the detection step performed with an amperometric biosensor based on glucose dehydrogenase (GDH). An immunoassay format with a labelled analyte derivative that competes with the analyte present in the sample for a limited amount of antibody binding sites was employed. The beta-galactosidase label hydrolyses the substrate aminophenyl-beta-galactopyranoside, and the generated aminophenol enters then into a bioelectrocatalytic amplification cycle at the GDH biosensor. The principle was applied for determination of 4-nitrophenol, with the best minimal concentration of 1.5 microM and a midpoint of the calibration of 24 microM. The potentials and limitations of such a system are discussed.


Assuntos
Nitrofenóis/análise , Técnicas Biossensoriais , Técnica de Imunoensaio Enzimático de Multiplicação , Glucose 1-Desidrogenase , Glucose Desidrogenase
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...