Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Materials (Basel) ; 14(21)2021 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-34772014

RESUMO

In this study, assessment of the antimicrobial activity of a novel, plasma-cured 2.5% (w/v) Cu(NO3)2-containing sol-gel surface was performed. In contrast to state-of-the-art sol-gel coatings, the plasma curing led to a gradient in cross-linking with the highest values at the top of the coating. As a result, the coating behaved simultaneously hard, scratch-resistant, and tough, the latter due to the more flexible bulk of the coating toward the substrate. Further, the diffusion and permeation through the coating also increased toward the substrate. In our study, tests according to ISO 22196 showed antibacterial activity of the 2.5% (w/v) Cu(NO3)2-containing sol-gel surface against all bacterial strains tested, and we expanded the testing further using a "dry" evaluation without an aqueous contact phase, which confirmed the antimicrobial efficacy of the 2.5% (w/v) Cu(NO3)2-containing sol-gel surface. However, further investigation under exposure to soiling with the addition of 0.3% albumin, used to simulate organic load, led to a significant impairment in the antibacterial effect under both tested conditions. Furthermore, re-testing of the surface after disinfection with 70% ethanol led to a total loss of antibacterial activity. Our results showed that besides the mere application of an antimicrobial agent to a surface coating, it is also necessary to consider the future use of these surfaces in the experimental phase combining industry and science. Therefore, a number of tests corresponding to the utilization of the surface should be obligative on the basis of this assessment.

2.
Nanomaterials (Basel) ; 9(2)2019 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-30781817

RESUMO

Zn-doped and Cu-doped SiOx films were synthesized by atmospheric pressure plasma chemical vapor deposition to study their antibacterial efficiency against Gram-negative Escherichia coli and their cytotoxic effect on the growth of mouse cells. Zn-rich and Cu-rich particles with diameters up to several microns were found to be homogeneously distributed within the SiOx films. For both doping elements, bacteria are killed within the first three hours after exposure to the film surface. In contrast, mouse cells grow well on the surfaces of both film types, with a slight inhibition present only after the first day of exposure. The obtained results indicate that the films show a high potential for use as effective antibacterial surfaces for medical applications.

3.
Skin Pharmacol Physiol ; 29(5): 257-265, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27811481

RESUMO

BACKGROUND: Application of cold atmospheric pressure plasmas (CAPs) in or on the human body was termed 'plasma medicine'. So far, plasmas were utilized for sterilization of implants, other heat-sensitive products, or employed for chemical surface modifications. By now, CAPs are further used effectively for wound treatment. The present study analyses the effect of a plasma jet with air or nitrogen as process gas, previously evaluated for antimicrobial efficacy, on human cells using a 3D skin model. METHODS: CAP treatment of 3D skin models consisting of a keratinocyte-containing epidermal layer and a fibroblast/collagen dermal matrix was performed using the Tigres plasma MEF technology. To evaluate the effects on the 3D skin models, the following plasma parameters were varied: process gas, input power, and treatment time. RESULTS: Low CAP doses exhibited good cell compatibility. Increasing input power or elongating treatment intervals led to detrimental effects on 3D skin model morphology as well as to release of inflammatory cytokines. It was further observed that air as process gas was more damaging compared to nitrogen. CONCLUSIONS: Treatment of 3D skin models with the plasma MEF nozzle using air or nitrogen is reported. A clearly dose- and time-dependent effect of CAPs could be observed in which the CAP based on nitrogen exhibited higher cell compatibility than the CAP generated from air. These settings might be recommended for medical in vivo applications such as wound decontamination.


Assuntos
Gases em Plasma , Pele/patologia , Ar , Técnicas de Cultura de Células , Células Cultivadas , Colágeno , Citocinas/genética , Citocinas/metabolismo , Fibroblastos , Expressão Gênica , Humanos , Queratinócitos , Nitrogênio , Técnicas de Cultura de Órgãos , Pele/metabolismo
4.
J Mater Sci Mater Med ; 26(2): 76, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25631274

RESUMO

The main goal of this investigation was the preparation of an antibacterial layer system for additional modification of wound dressings with atmospheric plasma. Furthermore, the modified wound dressings were checked on there bactericidal and cytotoxic activity. The layer system was applied by using a novel atmospheric pressure plasma chemical vapour deposition technique on a variety of textile substrates which are suitable as wound dressing materials. The layer system composed of silicon dioxide with in situ generated embedded silver nanoparticles. The bactericidal activity of the produced wound dressings was investigated against different bacteria like Staphylococcus aureus and Klebsiella pneumoniae while the cytotoxic potential of the coated wound dressings was verified using human keratinocytes. Even at low concentrations of silver precursor a strong antibacterial effect was observed in direct contact with S. aureus and K. pneumoniae. Furthermore, extractions produced from the coated textiles showed a good antibacterial effect. By means of optimised coating parameters a therapeutic window for those wound dressings could be identified. Consequently, the atmospheric pressure plasma chemical vapour deposition technique promise an effective and low cost modification of wound dressing materials.


Assuntos
Fenômenos Fisiológicos Bacterianos/efeitos dos fármacos , Bandagens/microbiologia , Materiais Revestidos Biocompatíveis/farmacologia , Nanopartículas Metálicas/administração & dosagem , Gases em Plasma/química , Prata/farmacologia , Antibacterianos/administração & dosagem , Antibacterianos/química , Pressão Atmosférica , Sobrevivência Celular/efeitos dos fármacos , Materiais Revestidos Biocompatíveis/síntese química , Portadores de Fármacos/síntese química , Portadores de Fármacos/farmacologia , Teste de Materiais , Nanopartículas Metálicas/química , Nanopartículas Metálicas/ultraestrutura , Prata/química
5.
Opt Express ; 19(18): 16985-95, 2011 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-21935058

RESUMO

Third harmonic generation (THG) of femtosecond laser pulses in sputtered nanocrystalline TiO2 thin films is investigated. Using layers of graded thickness, the dependence of THG on the film parameters is studied. The maximum THG signal is observed at a thickness of 180 nm. The corresponding conversion efficiency is 26 times larger compared to THG at the air-glass interface. For a demonstration of the capabilities of such a highly nonlinear material for pulse characterization, third-order autocorrelation and interferometric frequency-resolved optical gating (IFROG) traces are recorded with unamplified nanojoule pulses directly from a broadband femtosecond laser oscillator.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...