Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 80(11): 113102, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19947712

RESUMO

We report on an innovative two-dimensional imaging extreme ultraviolet (XUV) interferometer operating at 32 nm based on the mutual coherence of two laser high order harmonics (HOH) sources, separately generated in gas. We give the first evidence that the two mutually coherent HOH sources can be produced in two independent spatially separated gas jets, allowing for probing centimeter-sized objects. A magnification factor of 10 leads to a micron resolution associated with a subpicosecond temporal resolution. Single shot interferograms with a fringe visibility better than 30% are routinely produced. As a test of the XUV interferometer, we measure a maximum electronic density of 3x10(20) cm(-3) 1.1 ns after the creation of a plasma on aluminum target.

2.
Rev Sci Instrum ; 80(4): 043101, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19405645

RESUMO

We describe a Fourier transform (FT) spectrometer designed to operate down to 60 nm (20 eV) on a synchrotron radiation beamline for high resolution absorption spectrometry. As far as we know, such an instrument is not available below 140 nm mainly because manufacturing accurate and efficient beam splitters remains a major problem at these wavelengths, especially if a wide bandwidth operation is desired. In order to overcome this difficulty, we developed an interferometer based on wave front division instead of amplitude division. It relies on a modified Fresnel bimirror configuration that requires only flat mirrors. The instrument provides path difference scanning through the translation of one reflector. During the scanning, the moving reflector is controlled by an optical system that keeps its direction constant within a tolerable value and provides an accurate interferometric measurement of the path difference variation. Therefore, a regular interferogram sampling is obtained, producing a nominal spectral impulse response and an accurate spectral calibration. The first results presented in this paper show a measured spectral resolution of delta(sigma)=0.33 cm-1 (interval between spectral samples). This was obtained with a sampling interval of 29 nm (path difference) and 512 K samples from a one-sided interferogram using a cosine FT. Such a sampling interval should allow the recording of large bandwidth spectra down to lambda=58 nm with an ultimate resolving power of 500,000 at this wavelength. In order to check the instrument performances, we first recorded an interferogram from a He-Ne stabilized laser. This provided the actual spectral impulse function, which was found to be fully satisfactory. The determination of the impulse response distortion and of the noise on the vacuum ultraviolet (VUV) spectral range provided accurate information in the sampling error profile over a typical scan. Finally, the instrument has been moved to the SU5 undulator-based synchrotron radiation beamline (Super-ACO facility, LURE, Orsay, France). A high resolution spectrum of O2 (the Schumann-Runge absorption bands, 185-200 nm) was computed from recorded interferograms using the beamline monochromator at the zeroth order to feed the instrument with an 11% relative bandwidth "white" beam (2003). These UV measurements are very close to those found in the literature, showing nominal performances of the FT spectrometer that should translate into an unprecedented resolving power at shortest VUV wavelengths. A recent upgrade (2007) and future developments will be discussed in light of the current installation of the upgraded FT spectrometer as a permanent endstation for ultrahigh resolution absorption spectrometry on the VUV beamline DESIRS at SOLEIL, the new French third generation synchrotron facility.

3.
4.
Appl Opt ; 14(7): 1549-55, 1975 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-20154870

RESUMO

The visualization of traveling acoustic waves is achieved by means of acoustic stroboscopy. The limitations of the technique, interpretation of results, frequency range, and optical noise are reviewed. Two methods of noise reduction are studied: spatial filtering and holography. Optical holography of acoustic fields is also shown to offer the best advantages among the various methods of visualization outlined here.

5.
Appl Opt ; 14(9): 2184-9, 1975 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-20154981

RESUMO

Optical Fourier analysis of acoustic fields is used for the interpretation of acoustic disturbances. The method is applied to the study of modes propagating in an elastic waveguide. In particular, the mode dispersion curves are determined with an accuracy greater than that with purely acoustic methods.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA