Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann Emerg Med ; 74(3): 430-432, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-30773411

RESUMO

We present a case of elective naloxone-induced opioid withdrawal followed by buprenorphine rescue to initiate opioid use disorder treatment in the emergency department. This strategy may represent a safe alternative to prescribing buprenorphine for outpatient initiation, a method that puts the patient at risk for complications of unmonitored opioid withdrawal, including relapse. After confirmation that the naloxone-induced withdrawal was adequately treated with buprenorphine, the patient was discharged with prescribed buprenorphine to follow up in an addiction medicine clinic, where he was treated 2 days later.


Assuntos
Buprenorfina/administração & dosagem , Naloxona/administração & dosagem , Antagonistas de Entorpecentes/administração & dosagem , Tratamento de Substituição de Opiáceos/métodos , Síndrome de Abstinência a Substâncias/tratamento farmacológico , Administração Intravenosa , Adulto , Relação Dose-Resposta a Droga , Quimioterapia Combinada , Serviço Hospitalar de Emergência , Dependência de Heroína/tratamento farmacológico , Humanos , Masculino , Naloxona/efeitos adversos , Antagonistas de Entorpecentes/efeitos adversos
2.
Lab Chip ; 16(17): 3260-7, 2016 08 16.
Artigo em Inglês | MEDLINE | ID: mdl-27416111

RESUMO

Fluid control remains a challenge in development of portable lab-on-a-chip devices. Here, we show that microfluidic networks driven by single-frequency audio tones create resonant oscillating flow that is predicted by equivalent electrical circuit models. We fabricated microfluidic devices with fluidic resistors (R), inductors (L), and capacitors (C) to create RLC networks with band-pass resonance in the audible frequency range available on portable audio devices. Microfluidic devices were fabricated from laser-cut adhesive plastic, and a "buzzer" was glued to a diaphragm (capacitor) to integrate the actuator on the device. The AC flowrate magnitude was measured by imaging oscillation of bead tracers to allow direct comparison to the RLC circuit model across the frequency range. We present a systematic build-up from single-channel systems to multi-channel (3-channel) networks, and show that RLC circuit models predict complex frequency-dependent interactions within multi-channel networks. Finally, we show that adding flow rectifying valves to the network creates pumps that can be driven by amplified and non-amplified audio tones from common audio devices (iPod and iPhone). This work shows that RLC circuit models predict resonant flow responses in multi-channel fluidic networks as a step towards microfluidic devices controlled by audio tones.

3.
Prosthet Orthot Int ; 40(3): 320-8, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25710944

RESUMO

BACKGROUND: Lower-limb prosthesis users typically experience residual limb volume losses over the course of the day that can detrimentally affect socket fit. OBJECTIVES: To determine whether temporarily doffing the prosthesis encouraged residual limb fluid volume recovery and whether the recovered fluid was maintained. STUDY DESIGN: Experimental design. METHODS: Residual limb fluid volume was monitored on 16 participants in three test sessions each. Participants conducted six cycles of resting/standing/walking. Between the third and fourth cycles, participants sat for 30 min with the prosthesis and liner: donned (ON), the prosthesis doffed but the liner donned (LINER), or the prosthesis and liner doffed (OFF). RESULTS: Percentage fluid volume gain and retention were greatest for the OFF condition followed by the LINER condition. Participants experienced fluid volume losses for the ON condition. CONCLUSION: Doffing the prosthesis or both the prosthesis and liner during rest improved residual limb fluid volume retention compared with leaving the prosthesis and liner donned. CLINICAL RELEVANCE: Practitioners should advise patients who undergo high daily limb volume losses to consider temporarily doffing their prosthesis. Fluid volume retention during subsequent activity will be highest if both the prosthesis and liner are doffed.


Assuntos
Cotos de Amputação/fisiopatologia , Amputação Cirúrgica/reabilitação , Deslocamentos de Líquidos Corporais/fisiologia , Desenho de Prótese/métodos , Ajuste de Prótese/métodos , Adulto , Idoso , Amputação Cirúrgica/métodos , Amputados/reabilitação , Impedância Elétrica , Líquido Extracelular , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tíbia/cirurgia , Fatores de Tempo
4.
IEEE Trans Biomed Eng ; 63(8): 1760-70, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-26595906

RESUMO

OBJECTIVE: The objective of this research was to develop a bioimpedance platform for monitoring fluid volume in residual limbs of people with trans-tibial limb loss using prostheses. METHODS: A customized multifrequency current stimulus profile was sent to thin flat electrodes positioned on the thigh and distal residual limb. The applied current signal and sensed voltage signals from four pairs of electrodes located on the anterior and posterior surfaces were demodulated into resistive and reactive components. An established electrical model (Cole) and segmental limb geometry model were used to convert results to extracellular and intracellular fluid volumes. Bench tests and testing on amputee participants were conducted to optimize the stimulus profile and electrode design and layout. RESULTS: The proximal current injection electrode needed to be at least 25 cm from the proximal voltage sensing electrode. A thin layer of hydrogel needed to be present during testing to ensure good electrical coupling. Using a burst duration of 2.0 ms, intermission interval of 100 µs, and sampling delay of 10 µs at each of 24 frequencies except 5 kHz, which required a 200-µs sampling delay, the system achieved a sampling rate of 19.7 Hz. CONCLUSION: The designed bioimpedance platform allowed system settings and electrode layouts and positions to be optimized for amputee limb fluid volume measurement. SIGNIFICANCE: The system will be useful toward identifying and ranking prosthetic design features and participant characteristics that impact residual limb fluid volume.


Assuntos
Cotos de Amputação/fisiopatologia , Amputados/reabilitação , Membros Artificiais , Impedância Elétrica , Líquido Extracelular/fisiologia , Processamento de Sinais Assistido por Computador , Eletrodos , Humanos , Hidrogel de Polietilenoglicol-Dimetacrilato , Desenho de Prótese
5.
Resuscitation ; 83(8): 961-5, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22310728

RESUMO

BACKGROUND: Quality of cardiopulmonary resuscitation (CPR) is a key determinant of outcome following out-of-hospital cardiac arrest (OHCA). Recent evidence shows manual chest compressions are typically too shallow, interruptions are frequent and prolonged, and incomplete release between compressions is common. Mechanical chest compression systems have been developed as adjuncts for CPR but interruption of CPR during their use is not well documented. AIM: Analyze interruptions of CPR during application and use of the LUCAS™ chest compression system. METHODS: 54 LUCAS 1 devices operated on compressed air, deployed in 3 major US emergency medical services systems, were used to treat patients with OHCA. Electrocardiogram and transthoracic impedance data from defibrillator/monitors were analyzed to evaluate timing of CPR. Separately, providers estimated their CPR interruption time during application of LUCAS, for comparison to measured application time. RESULTS: In the 32 cases analyzed, compressions were paused a median of 32.5s (IQR 25-61) to apply LUCAS. Providers' estimates correlated poorly with measured pause length; pauses were often more than twice as long as estimated. The average device compression rate was 104/min (SD 4) and the average compression fraction (percent of time compressions were occurring) during mechanical CPR was 0.88 (SD 0.09). CONCLUSIONS: Interruptions in chest compressions to apply LUCAS can be <20s but are often much longer, and users do not perceive pause time accurately. Therefore, we recommend better training on application technique, and implementation of systems using impedance data to give users objective feedback on their mechanical chest compression device use.


Assuntos
Reanimação Cardiopulmonar/instrumentação , Serviços Médicos de Emergência/métodos , Parada Cardíaca Extra-Hospitalar/terapia , Cardiografia de Impedância , Reanimação Cardiopulmonar/métodos , Humanos , Inquéritos e Questionários
6.
J Rehabil Res Dev ; 49(8): 1229-38, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23341315

RESUMO

A device using radio frequency identification (RFID) technology was developed to continuously monitor sock use in people who use prosthetic limbs. RFID tags were placed on prosthetic socks worn by subjects with transtibial limb loss, and a high-frequency RFID reader and antenna were placed in a portable unit mounted to the outside of the prosthetic socket. Bench testing showed the device to have a maximum read range between 5.6 cm and 12.7 cm, depending on the RFID tag used. Testing in a laboratory setting on three participants with transtibial amputation showed that the device correctly monitored sock presence during sitting, standing, and walking activity when one or two socks were worn but was less reliable when more socks were used. Accurate detection was sensitive to orientation of the tag relative to the reader, presence of carbon fiber in the prosthetic socket, pistoning of the limb in the socket, and overlap among the tags. Use of ultra-high-frequency RFID may overcome these limitations. With improvements, the technology may prove useful to practitioners prescribing volume accommodation strategies for patients by providing information about sock use between clinical visits, including timing and consistency of daily sock-ply changes.


Assuntos
Cotos de Amputação/fisiopatologia , Amputados/reabilitação , Membros Artificiais , Dispositivo de Identificação por Radiofrequência/métodos , Caminhada , Vestuário , Impedância Elétrica , Humanos , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Ajuste de Prótese , Tíbia/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...