Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Nanosci Nanotechnol ; 19(3): 1780-1785, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30469266

RESUMO

In this study, H2S-sensing characteristics of the spincoated ruthenium loaded molybdenum trioxide nanoflake (Ru-MoO3 NFs) thick films with 0-1.00 wt% Ru concentrations have been studied. The morphologies, cross section and elemental compositions of sensing films were characterized by SEM and EDS line-scan analyses. The influence of Ru concentration on H2S response of the thick film sensor was studied at the operating temperatures ranging from 200 to 350 °C. It was found that 0.5 wt% RuMoO3 film exhibited an enhanced response of ~30 to 10 ppm H2S, which was more than one order of magnitude higher than that of unloaded one. Plausible mechanisms responsible for the enhanced H2S response by sensing films of Ru-MoO3 NFs were discussed on the basis of the catalytic spill-over effects and enhanced specific surface area provided by Ru nanoparticles.

2.
J Biomater Appl ; 31(2): 230-40, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27358375

RESUMO

Recently, three-dimensional graphene interconnected network has attracted great interest as a scaffold structure for tissue engineering due to its high biocompatibility, high electrical conductivity, high specific surface area and high porosity. However, free-standing three-dimensional graphene exhibits poor flexibility and stability due to ease of disintegration during processing. In this work, three-dimensional graphene is composited with polydimethylsiloxane to improve the structural flexibility and stability by a new simple two-step process comprising dip coating of polydimethylsiloxane on chemical vapor deposited graphene/Ni foam and wet etching of nickel foam. Structural characterizations confirmed an interconnected three-dimensional multi-layer graphene structure with thin polydimethylsiloxane scaffold. The composite was employed as a substrate for culture of L929 fibroblast cells and its cytocompatibility was evaluated by cell viability (Alamar blue assay), reactive oxygen species production and vinculin immunofluorescence imaging. The result revealed that cell viability on three-dimensional graphene/polydimethylsiloxane composite increased with increasing culture time and was slightly different from a polystyrene substrate (control). Moreover, cells cultured on three-dimensional graphene/polydimethylsiloxane composite generated less ROS than the control at culture times of 3-6 h. The results of immunofluorescence staining demonstrated that fibroblast cells expressed adhesion protein (vinculin) and adhered well on three-dimensional graphene/polydimethylsiloxane surface. Good cell adhesion could be attributed to suitable surface properties of three-dimensional graphene/polydimethylsiloxane with moderate contact angle and small negative zeta potential in culture solution. The results of electrochemical study by cyclic voltammetry showed that an oxidation current signal with no apparent peak was induced by fibroblast cells and the oxidation current at an oxidation potential of +0.9 V increased linearly with increasing cell number. Therefore, the three-dimensional graphene/polydimethylsiloxane composite exhibits high cytocompatibility and can potentially be used as a conductive substrate for cell-based electrochemical sensing.


Assuntos
Materiais Biocompatíveis/química , Dimetilpolisiloxanos/química , Técnicas Eletroquímicas/métodos , Grafite/química , Alicerces Teciduais/química , Animais , Adesão Celular , Linhagem Celular , Fibroblastos/citologia , Camundongos , Níquel/química , Espécies Reativas de Oxigênio/química , Propriedades de Superfície
3.
Sci Rep ; 6: 23733, 2016 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-27020705

RESUMO

In this work, a novel platform for surface-enhanced Raman spectroscopy (SERS)-based chemical sensors utilizing three-dimensional microporous graphene foam (GF) decorated with silver nanoparticles (AgNPs) is developed and applied for methylene blue (MB) detection. The results demonstrate that silver nanoparticles significantly enhance cascaded amplification of SERS effect on multilayer graphene foam (GF). The enhancement factor of AgNPs/GF sensor is found to be four orders of magnitude larger than that of AgNPs/Si substrate. In addition, the sensitivity of the sensor could be tuned by controlling the size of silver nanoparticles. The highest SERS enhancement factor of ∼ 5 × 10(4) is achieved at the optimal nanoparticle size of 50 nm. Moreover, the sensor is capable of detecting MB over broad concentration ranges from 1 nM to 100 µM. Therefore, AgNPs/GF is a highly promising SERS substrate for detection of chemical substances with ultra-low concentrations.

4.
ACS Appl Mater Interfaces ; 7(43): 24338-52, 2015 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-26479951

RESUMO

In this work, flame-spray-made undoped SnO2 nanoparticles were loaded with 0.1-5 wt % electrolytically exfoliated graphene and systematically studied for NO2 sensing at low working temperatures. Characterizations by X-ray diffraction, transmission/scanning electron microscopy, and Raman and X-ray photoelectron spectroscopy indicated that high-quality multilayer graphene sheets with low oxygen content were widely distributed within spheriodal nanoparticles having polycrystalline tetragonal SnO2 phase. The 10-20 µm thick sensing films fabricated by spin coating on Au/Al2O3 substrates were tested toward NO2 at operating temperatures ranging from 25 to 350 °C in dry air. Gas-sensing results showed that the optimal graphene loading level of 0.5 wt % provided an ultrahigh response of 26,342 toward 5 ppm of NO2 with a short response time of 13 s and good recovery stabilization at a low optimal operating temperature of 150 °C. In addition, the optimal sensor also displayed high sensor response and relatively short response time of 171 and 7 min toward 5 ppm of NO2 at room temperature (25 °C). Furthermore, the sensors displayed very high NO2 selectivity against H2S, NH3, C2H5OH, H2, and H2O. Detailed mechanisms for the drastic NO2 response enhancement by graphene were proposed on the basis of the formation of graphene-undoped SnO2 ohmic metal-semiconductor junctions and accessible interfaces of graphene-SnO2 nanoparticles. Therefore, the electrolytically exfoliated graphene-loaded FSP-made SnO2 sensor is a highly promising candidate for fast, sensitive, and selective detection of NO2 at low operating temperatures.

5.
Talanta ; 84(5): 1384-9, 2011 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-21641456

RESUMO

In this work, the use of three-electrode electrochemical sensing system with an electrowetting-on-dielectric (EWOD) digital microfluidic device is reported for quantitative analysis of iodide. T-junction EWOD mixer device was designed using arrays of 50-µm spaced square electrodes for mixing buffer reagent and analyte droplets. For fabrication of EWOD chips, 5-µm thick silver EWOD electrodes were formed on a glass substrate by means of sputtering and lift-off process. PDMS and Teflon thin films were then coated on the electrodes by spin coating to yield hydrophobic surface. An external three-electrode system consisting of Au working, Ag reference and Pt auxiliary wires were installed over EWOD electrodes at the end of T-junction mixer. In experiment, a few-microliter droplets of Tris buffer and iodide solutions were moved toward the mixing junction and transported toward electrochemical electrodes by EWOD process. A short processing time within seconds was achieved at EWOD applied voltage of 300V. The analyte droplets mixed with different concentrations were successfully analyzed by cyclic voltametry. Therefore, the combination of EWOD digital microfluidic and electrochemical sensing system has successfully been demonstrated for rapid chemical analysis with minimal reagent consumption.


Assuntos
Eletroquímica/instrumentação , Eletroumectação/instrumentação , Iodetos/análise , Condutividade Elétrica , Impedância Elétrica , Eletrodos , Concentração de Íons de Hidrogênio , Iodetos/química , Cinética
6.
Talanta ; 84(5): 1390-5, 2011 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-21641457

RESUMO

In this work, carbon nanotubes (CNTs) nanoarrays in anodized aluminum oxide (AAO-CNTs) nanopore is integrated on a microfluidic flow injection system for in-channel electrochemical detection of iodide. The device was fabricated from PDMS (polydimethylsiloxane) microchannel bonded on glass substrates that contains three-electrode electrochemical system, including AAO-CNTs as a working electrode, silver as a reference electrode and platinum as an auxiliary electrode. Aluminum, stainless steel catalyst, silver and platinum layers were sputtered on the glass substrate through shadow masks. Aluminum layer was then anodized by two-step anodization process to form nanopore template. CNTs were then grown in AAO template by thermal chemical vapor deposition. The amperometric detection of iodide was performed in 500-µm-wide and 100-µm-deep microchannels on the microfluidic chip. The influences of flow rate, injection volume and detection potential on the current response were optimized. From experimental results, AAO-CNTs electrode on chip offers higher sensitivity and wider dynamic range than CNTs electrode with no AAO template.


Assuntos
Óxido de Alumínio/química , Análise de Injeção de Fluxo/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Nanotubos de Carbono/química , Iodeto de Potássio/análise , Dimetilpolisiloxanos/química , Eletrodos , Vidro/química , Indicadores e Reagentes/química , Iodeto de Potássio/química , Fatores de Tempo , Volatilização
7.
Sensors (Basel) ; 10(8): 7705-15, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-22163623

RESUMO

In this work we have fabricated hydrogen gas sensors based on undoped and 1 wt% multi-walled carbon nanotube (MWCNT)-doped tungsten oxide (WO(3)) thin films by means of the powder mixing and electron beam (E-beam) evaporation technique. Hydrogen sensing properties of the thin films have been investigated at different operating temperatures and gas concentrations ranging from 100 ppm to 50,000 ppm. The results indicate that the MWCNT-doped WO(3) thin film exhibits high sensitivity and selectivity to hydrogen. Thus, MWCNT doping based on E-beam co-evaporation was shown to be an effective means of preparing hydrogen gas sensors with enhanced sensing and reduced operating temperatures. Creation of nanochannels and formation of p-n heterojunctions were proposed as the sensing mechanism underlying the enhanced hydrogen sensitivity of this hybridized gas sensor. To our best knowledge, this is the first report on a MWCNT-doped WO(3) hydrogen sensor prepared by the E-beam method.


Assuntos
Gases/análise , Hidrogênio/análise , Nanotecnologia/métodos , Nanotubos de Carbono/química , Óxidos/química , Reprodutibilidade dos Testes , Temperatura , Tungstênio/química
8.
Sensors (Basel) ; 9(11): 8658-68, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-22291529

RESUMO

In this report, a new cholesterol sensor is developed based on a vertically aligned CNT electrode with two-step electrochemical polymerized enzyme immobilization. Vertically aligned CNTs are selectively grown on a 1 mm(2) window of gold coated SiO(2)/Si substrate by thermal chemical vapor deposition (CVD) with gravity effect and water-assisted etching. CNTs are then simultaneously functionalized and enzyme immobilized by electrochemical polymerization of polyaniline and cholesterol enzymes. Subsequently, ineffective enzymes are removed and new enzymes are electrochemically recharged. Scanning electron microscopic characterization indicates polymer-enzyme nanoparticle coating on CNT surface. Cyclic voltammogram (CV) measurements in cholesterol solution show the oxidation and reduction peaks centered around 450 and -220 mV, respectively. An approximately linear relationship between the cholesterol concentration and the response current could be observed in the concentration range of 50-300 mg/dl with a sensitivity of approximately 0.22 µA/mg·dl(-1), which is considerably higher compared to previously reported CNT bioprobe. In addition, good specificity toward glucose, uric acid acetaminophen and ascorbic acid have been obtained. Moreover, sensors have satisfactory stability, repeatability and life time. Therefore, the electropolymerized CNT bioprobe is promising for cholesterol detection in normal cholesterol concentration in human blood.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA