Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 229
Filtrar
1.
Minerva Cardioangiol ; 60(2): 157-66, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22495164

RESUMO

Percutaneous coronary intervention of degenerated saphenous vein grafts remains relatively high risk when compared to native vessel interventions, despite advances in pharmacotherapy and embolic protection. This article discusses the phenomenon of distal embolization that seems to plague saphenous vein graft interventions, reviews device-based strategies for embolic protection, and offers a perspective on the utility of percutaneous saphenous vein graft intervention in both elective and acute settings.


Assuntos
Ponte de Artéria Coronária , Dispositivos de Proteção Embólica , Embolia/prevenção & controle , Embolização Terapêutica/instrumentação , Embolização Terapêutica/métodos , Veia Safena/transplante , Stents , Embolia/tratamento farmacológico , Humanos
3.
Heart ; 95(15): 1214-9, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19196732

RESUMO

Clinical trials have demonstrated the beneficial impact of clopidogrel in preventing major adverse cardiovascular events (MACE), particularly in patients undergoing percutaneous coronary intervention (PCI). The concept of biological clopidogrel resistance emerged with the finding of persistent platelet activation despite clopidogrel therapy in some patients. Further, a link between biological clopidogrel resistance and thrombotic recurrence after PCI was observed and a threshold of platelet reactivity (PR) for thrombotic events was suggested. Consistently, in recent trials, enhanced PR inhibition translated into a reduction in the rate of MACE after PCI. This review aims to present the emergence of the concept of PR monitoring in patients undergoing PCI following recent advances in this field.


Assuntos
Trombose Coronária/terapia , Inibidores da Agregação Plaquetária/uso terapêutico , Agregação Plaquetária/efeitos dos fármacos , Piridinas/uso terapêutico , Ticlopidina/análogos & derivados , Angioplastia Coronária com Balão , Clopidogrel , Resistência a Medicamentos , Humanos , Testes de Função Plaquetária , Antagonistas do Receptor Purinérgico P2 , Ticlopidina/uso terapêutico
4.
Heart ; 89(1): 84-90, 2003 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-12482801

RESUMO

OBJECTIVE: To compare the effects of arterial remodelling and plaque characteristics on the mechanisms of direct stenting and predilatation stenting. Direct stenting has become routine in some laboratories and differs technically from predilatation stenting. METHODS: Pre- and post-interventional volumetric intravascular ultrasound (IVUS) was undertaken in 30 patients with direct stenting and in 30 with predilatation stenting of non-calcified native coronary lesions, using the same stent design and stent length. Lumen, vessel (external elastic membrane (EEM)), and plaque (plaque + media) volumes were calculated. Remodelling was determined by comparing the EEM area at the centre of the lesion with the EEM areas at proximal and distal reference sites. Plaque eccentricity was defined as the thinnest plaque diameter to the thickest plaque diameter ratio. Plaque composition was characterised as soft, mixed, or dense. RESULTS: All volumetric IVUS changes were similar in the two groups. Pre-intervention remodelling remained uninfluenced after direct stenting, but was neutralised after predilatation stenting. Eccentric lesions responded to intervention by a greater luminal gain owing to greater vessel expansion in direct stenting. Plaque composition influenced luminal gain in direct stenting, the gain being greatest in the softest plaques; in predilatation stenting, luminal gain was equivalent but vessel expansion was greater for "dense" plaque and plaque reduction greater for "soft" plaque. CONCLUSIONS: In non-calcified lesions, the mechanisms of lumen enlargement after direct or predilatation stenting are significantly influenced by atherosclerotic remodelling, plaque eccentricity, and plaque composition.


Assuntos
Doença da Artéria Coronariana/patologia , Vasos Coronários/patologia , Stents , Cateterismo/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Elasticidade , Humanos , Variações Dependentes do Observador , Imagens de Fantasmas , Valor Preditivo dos Testes , Pressão , Valores de Referência , Sensibilidade e Especificidade , Ultrassonografia
5.
Circulation ; 104(25): 3020-2, 2001 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-11748092

RESUMO

BACKGROUND: We used serial volumetric (post-irradiation and follow-up) intravascular ultrasound (IVUS) to compare the effectiveness of gamma-irradiation ((192)Ir) in saphenous vein graft (SVG) versus native coronary artery in-stent restenosis (ISR). METHODS AND RESULTS: The study population consisted of 47 patients with native coronary artery ISR from WRIST (Washington Radiation for In-Stent Restenosis Trial) and 31 patients with SVG ISR (12 from the WRIST and 19 from SVGWRIST). After irradiation and at 6-month follow-up, stent, lumen, and intimal hyperplasia (IH, stent minus lumen) areas were measured every 1 mm. ISR length was similar in the 2 groups (29+/-12 versus 29+/-14 mm, P=0.9). Post-intervention measurements of stent (280+/-154 versus 324+/-270 mm(3), P=0.4), lumen (184+/-91 versus 214+/-172 mm(3), P=0.3), and IH (96+/-77 versus 109+/-119 mm(3), P=0.5) volumes were similar in the 2 groups. The post-intervention minimum lumen cross sectional areas tended to be smaller in native artery ISR lesions (4.7+/-1.7 versus 5.4+/-1.6 mm(2), P=0.11). During follow-up, there was a slight increase in IH volume (9+/-38 mm(3)) in native artery ISR lesions and a slight decrease in IH volume in SVG ISR lesions (-9+/-32 mm(3), P=0.0463). There was also a slight decrease in minimum lumen area in the native artery ISR lesions versus a slight increase in minimum lumen area in the SVG ISR lesions (-0.8+/-1.7 versus 0.2+/-1.1, P=0.0087). As a result, the follow-up minimum lumen area in native artery lesions was smaller than in SVG ISR lesions (4.1+/-2.1 mm(2) versus 5.6+/-2.2 mm(2), P=0.0067). CONCLUSION: gamma-Irradiation with (192)Ir brachytherapy appears to be as effective in SVGs as it is in native artery ISR lesions.


Assuntos
Doença das Coronárias/radioterapia , Vasos Coronários/efeitos da radiação , Raios gama/uso terapêutico , Veia Safena/transplante , Stents , Idoso , Angiografia Coronária , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/terapia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Resultado do Tratamento , Ultrassonografia de Intervenção
6.
Am Heart J ; 142(6): 970-4, 2001 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11717599

RESUMO

OBJECTIVES: Serial intravascular ultrasonographic (IVUS) studies have shown that in-stent restenosis is the result of intimal hyperplasia (IH). However, routine preintervention IVUS imaging has suggested that many restenotic stents were inadequately deployed. The purpose of this IVUS study was to determine the incidence of mechanical problems contributing to in-stent restenosis (ISR). METHODS: Between April 1994 and June 2000, 1090 patients with ISR were treated at the Washington Hospital Center. All underwent preintervention IVUS imaging. IVUS measurements included proximal and distal reference lumen areas and diameters; stent, minimum lumen, and IH (stent minus lumen) areas; and IH burden (IH/stent area). RESULTS: In 49 ISR lesions (4.5%), there were morphologic findings that contributed to the restenosis. These were termed mechanical complications. Examples include (1) missing the lesion (eg, an aorto-ostial stenosis), (2) stent "crush," and (3) having the stent stripped off the balloon during the implantation procedure. Excluding mechanical complications, stent underexpansion was common. In 20% of the ISR cases the stents had a cross-sectional area (CSA) at the site of the lesion <80% of the average reference lumen area. Twenty percent of lesions had a minimum stent area <5.0 mm(2) and an additional 18% had a minimum stent area of 5.0 to 6.0 mm(2). Twenty-four percent of lesions had an IH burden <60%. CONCLUSION: Mechanical problems related to stent deployment procedures contribute to a significant minority of ISR lesions (approximately 25%).


Assuntos
Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Stents/efeitos adversos , Análise de Falha de Equipamento , Feminino , Humanos , Hiperplasia/diagnóstico por imagem , Masculino , Recidiva , Estudos Retrospectivos , Túnica Íntima/diagnóstico por imagem , Ultrassonografia de Intervenção
9.
J Am Coll Cardiol ; 38(4): 1049-53, 2001 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11583881

RESUMO

OBJECTIVES: This study was designed to analyze the in-hospital and six-month clinical and angiographic outcomes of patients with chronic renal failure (CRF) treated with intracoronary radiation for the prevention of recurrence of in-stent restenosis. BACKGROUND: Patients with CRF are at a higher risk than the general population for accelerated atherosclerotic cardiovascular disease and for restenosis after percutaneous coronary intervention. Previous studies have shown the effectiveness of both beta and gamma radiation in preventing recurrent restenosis in patients with in-stent restenosis. METHODS: We studied the in-hospital and six-month clinical and angiographic outcomes of 118 patients with CRF and 481 consecutive patients without CRF who were treated with intracoronary radiation for the prevention of recurrence of in-stent restenosis in native coronaries and saphenous vein grafts. RESULTS: Patients with CRF were usually older, women, hypertensive and diabetic, with multivessel disease and with reduced left ventricular function. In-hospital outcome for patients with CRF was marred by a higher incidence of death, non-Q-wave myocardial infarction and major vascular and bleeding complications. At six-month follow-up, the mortality rate was higher in patients with CRF, 7.6% compared with 1.9% in non-CRF patients (p = 0.003). Restenosis, target lesion revascularization (TLR) and target vessel revascularization (TVR) rates were similar in the two groups. In patients with CRF, radiation therapy compared to placebo reduced restenosis (53.8% vs. 22.6%, p = 0.04), TLR (71.4% vs. 15.3%, p < 0.0001) and TVR (78.6% vs. 23.7%, p = 0.0002). CONCLUSIONS: Intracoronary radiation for the prevention of recurrence of in-stent restenosis achieved similar rates of restenosis and revascularization procedures in patients with and without CRF. Despite this benefit, patients with renal dysfunction continued to have significantly higher in-hospital and six-month adverse outcomes.


Assuntos
Doença das Coronárias/radioterapia , Falência Renal Crônica/complicações , Idoso , Braquiterapia , Angiografia Coronária , Doença das Coronárias/complicações , Doença das Coronárias/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Prevenção Secundária , Stents
11.
Am J Cardiol ; 88(4): 365-70, 2001 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-11545755

RESUMO

The purpose of this study was to use intravascular ultrasound (IVUS) to clarify the morphology of coronary aneurysms diagnosed by angiography. Seventy-seven consecutive patients with an aneurysmal dilatation in a native coronary artery diagnosed by angiography (defined as a lesion lumen diameter 25% larger than reference) were evaluated by IVUS. IVUS true aneurysms were defined as having an intact vessel wall and a maximum lumen area 50% larger than proximal reference. IVUS pseudoaneurysms had a loss of vessel wall integrity and damage to adventitia or perivascular tissue. Complex plaques were lesions with ruptured plaque or spontaneous or unhealed dissection. Aneurysmal dilatation and reference segments were assessed using standard IVUS quantitative techniques. Twenty-one lesions (27%) were classified as true aneurysms, 3 (4%) were classified as pseudoaneurysms, 12 (16%) were complex plaques, and the other 41 (53%) were normal arterial segments adjacent to > or =1 stenosis. The maximum lumen area within the aneurysmal segment was largest for pseudoaneurysm (35.1 +/- 10.4 mm(2)), 22.1 +/- 9.9 mm(2) for true aneurysm, and similar for complex plaques (11.2 +/- 3.5 mm(2)) and normal segments with adjacent stenoses (13.8 +/- 6.4 mm(2)): analysis of variance, p <0.0001. Only one third of angiographically diagnosed aneurysms had the IVUS appearance of a true or pseudoaneurysm. Instead, most angiographically diagnosed aneurysms had the morphology of complex plaques or normal segments with adjacent stenoses.


Assuntos
Aneurisma Coronário/diagnóstico por imagem , Ultrassonografia de Intervenção , Idoso , Falso Aneurisma/diagnóstico por imagem , Constrição Patológica , Aneurisma Coronário/patologia , Angiografia Coronária , Doença da Artéria Coronariana/patologia , Vasos Coronários/patologia , Dilatação Patológica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
13.
J Am Coll Cardiol ; 38(3): 638-41, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11527609

RESUMO

OBJECTIVES: We evaluated the vascular complications after hemostasis with arteriotomy closure devices (ACD) versus manual compression after percutaneous coronary interventions (PCI). BACKGROUND: Previous clinical studies have indicated that ACD can be used for achievement of hemostasis and early ambulation after PCI. This study investigated the safety of ACD in achieving hemostasis after PCI compared with manual compression in a large cohort of consecutive patients. METHODS: A total of 5,093 patients were followed after PCI was performed with the transfemoral approach. Univariate and multivariate analysis were used to identify the predictors of vascular complications with ACD (n = 516) or with manual compression (n = 5,892) as a hemostasis option after sheath removal. RESULTS: The use of ACD was associated with a more frequent occurrence of hematoma compared with manual compression (9.3 vs. 5.1%, p < 0.001). There was also a higher rate of significant hematocrit drop (>15%) with ACD versus manual compression (5.2% vs. 2.5%, p < 0.001). Similar rates of pseudoaneurysm and arteriovenous fistulae were noted with either hemostasis technique. Vascular surgical repair at the access site was required more often with ACD versus manual compression (2.5 vs. 1.5%, p = 0.03). CONCLUSIONS: In this early experience with ACD after PCI, their use was associated with higher vascular complication rates than hemostasis with manual compression.


Assuntos
Angioplastia Coronária com Balão , Técnicas Hemostáticas , Punções/efeitos adversos , Doenças Vasculares/etiologia , Idoso , Falso Aneurisma/etiologia , Fístula Arteriovenosa/etiologia , Feminino , Artéria Femoral , Hematócrito , Hematoma/etiologia , Técnicas Hemostáticas/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Pressão , Estudos Retrospectivos
14.
Circulation ; 104(8): 856-9, 2001 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-11514368

RESUMO

BACKGROUND: The efficacy of coronary gamma-irradiation in preventing recurrent in-stent restenosis (ISR) is well established. However, brachytherapy may be less effective in very long, diffuse ISR lesions. METHODS AND RESULTS: We used serial intravascular ultrasound (IVUS) to study patients with long, diffuse ISR lesions (length, 36 to 80 mm) who were enrolled in (1) Long WRIST (Washington Radiation In-Stent Restenosis Trial), a double-blind, placebo-controlled trial of intracoronary gamma-irradiation (15 Gy at 2 mm from the source) and (2) high-dose (HD) Long WRIST, a registry that used a dose prescription of 18 Gy at 2 mm from the source. IVUS was performed using automated pullback (0.5 mm/s). Stent, lumen, and intimal hyperplasia were measured at 2-mm intervals. Complete postintervention and follow-up IVUS imaging was available in 30 irradiated and 34 placebo patients from Long WRIST and in 25 patients from HD Long WRIST. Stent length was longer in HD Long WRIST than in placebo or treated patients in Long WRIST (P=0.0064 and P=0.0125, respectively). Otherwise, baseline measurements were similar. At follow-up, the minimum lumen area was largest in the HD Long WRIST patients (4.0+/-1.4 mm(2)); areas were 2.9+/-1.0 mm(2) in irradiated patients in Long WRIST and 1.9+/-1.1 mm(2) in placebo patients in Long WRIST (P<0.005 for all comparisons). CONCLUSIONS: - Serial IVUS analysis shows that gamma-irradiation reduces recurrent in-stent neointimal hyperplasia in long, diffuse ISR lesions; however, it is even more effective when given at a higher dose.


Assuntos
Raios gama/uso terapêutico , Oclusão de Enxerto Vascular/prevenção & controle , Revascularização Miocárdica , Stents , Ultrassonografia de Intervenção , Braquiterapia/métodos , Doença das Coronárias/cirurgia , Relação Dose-Resposta à Radiação , Método Duplo-Cego , Oclusão de Enxerto Vascular/classificação , Oclusão de Enxerto Vascular/diagnóstico , Humanos , Pessoa de Meia-Idade , Revascularização Miocárdica/efeitos adversos , Revascularização Miocárdica/métodos , Fatores de Risco , Prevenção Secundária , Stents/efeitos adversos , Resultado do Tratamento , Grau de Desobstrução Vascular/efeitos da radiação
15.
J Am Coll Cardiol ; 38(1): 150-4, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11451265

RESUMO

OBJECTIVES: We sought to determine whether strategies to reduce procedural distal embolization and late repeat revascularization have resulted in more favorable outcomes after saphenous vein graft (SVG) angioplasty. BACKGROUND: Angioplasty of SVG lesions has been associated with frequent procedural and late cardiac events. Therefore, evolving strategies have been attempted to improve outcomes after SVG angioplasty. METHODS: We compared our earlier experience (1990 to 1994) of 1,055 patients with 1,412 SVG lesions with a recent group (1995 to 1998) of 964 patients with 1,315 lesions. RESULTS: Baseline characteristics were similar between the groups. However, there were significantly more unfavorable lesion characteristics (older, longer and significantly more degenerated SVGs) in the recent series. Between the two periods, there was decreased use ofatheroablative devices, whereas stent use increased. The procedural success rates (96.6% vs. 96.1%) were similar. However, one-year outcome (event-free survival) was significantly improved in the more recent experience (70.7% vs. 59.1%, p < 0.0001), especially late mortality (6.1% vs. 11.3%, p < 0.0001). Multivariate analysis showed stent use to be the only protective variable for both periods. CONCLUSIONS: This study shows that despite higher risk lesions, strategies to reduce distal embolization have maintained high procedural success. Late cardiac events, including mortality, have also been substantially reduced.


Assuntos
Angioplastia com Balão , Ponte de Artéria Coronária/métodos , Doença das Coronárias/cirurgia , Oclusão de Enxerto Vascular/terapia , Veia Safena/transplante , Idoso , Doença das Coronárias/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Stents , Resultado do Tratamento
16.
Am J Cardiol ; 88(2): 129-33, 2001 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-11448408

RESUMO

Troponin I is a predictive marker of short- and intermediate-term adverse cardiac events in patients with acute coronary syndromes (ACS). These high-risk patients may benefit from early percutaneous coronary intervention. However, whether additional myocardial injury, defined as postprocedural troponin I elevation, may be associated with adverse short- and intermediate-term outcomes has not been fully explored. Accordingly, we studied 132 consecutive patients with non-ST-elevation ACS (62% with non-Q-wave myocardial infarction) and elevated troponin I levels at admission (>0.15 ng/ml) who underwent percutaneous coronary intervention > or =48 hours after admission. Troponin I levels were routinely measured at 6 and 18 to 24 hours after intervention and patients were stratified according to the presence or absence of troponin I re-elevation, defined as postprocedural troponin I levels >1 times the admission levels. In-hospital and cumulative 6-month clinical outcomes were compared between groups. Patients with troponin I re-elevation (n = 51) were older (68 +/- 13 vs 64 +/- 12 years, p = 0.05) and had experienced prior myocardial infarction more frequently (92.5 vs 82.1, p = 0.09), but otherwise had similar baseline clinical characteristics. Patients with troponin I re-elevation had significantly higher in-hospital mortality (9.8% vs 0%, p = 0.016) and a higher 6-month cumulative death rate (24% vs 3.7%, p = 0.001). There was a trend for an increased 6-month myocardial infarction rate in patients with troponin I re-elevation (13.7% vs 3.7%, p = 0.11) and target vessel revascularization was similar between groups (16.7% vs 17.4%, p = 0.92). By multivariate analysis, troponin I re-elevation (odds ratio [OR] 6.2, p = 0.011) and diabetes mellitus (OR 5.7, p = 0.014) were the strongest independent predictors for increased 6-month cumulative mortality, whereas creatine kinase MB-fraction re-elevation had no prognostic value. We conclude that troponin I re-elevation after percutaneous coronary intervention in high-risk patients with ACS is associated with a substantial increase in mortality and reduced event-free survival at 6-month follow-up.


Assuntos
Infarto do Miocárdio/sangue , Infarto do Miocárdio/terapia , Troponina I/sangue , Idoso , Angioplastia Coronária com Balão , Estudos de Coortes , Creatina Quinase/sangue , Creatina Quinase Forma MB , Intervalo Livre de Doença , Feminino , Seguimentos , Mortalidade Hospitalar , Humanos , Isoenzimas/sangue , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/mortalidade , Valor Preditivo dos Testes , Prognóstico , Medição de Risco , Stents , Fatores de Tempo
18.
Am J Cardiol ; 87(12): 1356-60, 2001 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-11397353

RESUMO

We evaluated the short- and long-term clinical outcomes of 326 consecutive patients with chronic renal failure, not on dialysis, who had creatine kinase (CK)-myocardial band (MB) fraction elevation after successful percutaneous coronary intervention in a native coronary artery. Based on peak CK-MB levels measured after intervention, patients were divided into 3 groups: no elevation (group 1, n = 184), 1 to 3 x upper normal levels (group 2, n = 72), and >3 x upper normal levels (group 3, n = 70). Baseline clinical and angiographic characteristics were similar among the 3 groups. Angiographic success was similar among the 3 groups, although there was a significantly higher use of intra-aortic balloon pump in patients who had postprocedural CK-MB >3 x normal values and a higher rate of in-hospital complications, i.e., repeat catheterization, repeat target lesion intervention, pulmonary edema, renal function deterioration, emergency dialysis, and major bleeding complications. At 1-year follow-up, mortality rates were significantly higher in these patients (35.4% vs 22.0% for patients with CK-MB 1 to 3 x normal values and 16.7% for patients without CK-MB elevation, p = 0.007). Multivariate analysis showed that CK-MB >3 x normal (odds ratio 3.04; 95% confidence interval 1.41 to 6.57, p = 0.005) and intra-aortic balloon pump (odds ratio 1.49; confidence interval 1.15 to 1.93, p = 0.002) were independent predictors of late mortality. Therefore, patients with chronic renal failure who had CK-MB elevation >3 x the upper normal limit after a successful percutaneous coronary intervention had a higher incidence of in-hospital complications and a significantly higher mortality rate at 1-year follow-up than patients without CK-MB elevation or with <3 x normal CK-MB elevation.


Assuntos
Angioplastia Coronária com Balão , Doença das Coronárias/enzimologia , Creatina Quinase/sangue , Isoenzimas/sangue , Falência Renal Crônica/enzimologia , Idoso , Idoso de 80 Anos ou mais , Angiografia Coronária , Doença das Coronárias/mortalidade , Doença das Coronárias/terapia , Creatina Quinase Forma MB , Feminino , Seguimentos , Humanos , Falência Renal Crônica/mortalidade , Falência Renal Crônica/terapia , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/enzimologia , Infarto do Miocárdio/mortalidade , Fatores de Risco , Taxa de Sobrevida , Resultado do Tratamento
19.
Am J Cardiol ; 88(1): 1-4, 2001 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-11423049

RESUMO

Eighty-seven left main stenoses were evaluated by angiography and intravascular ultrasound. Intravascular ultrasound analysis included left main length (bifurcation to ostium), stenosis location, stenosis length, stenosis external elastic membrane, lumen, plaque & media cross-sectional area (CSA), plaque burden (plaque & media/external elastic membrane CSA), calcium arc, calcium length, eccentricity, and remodeling index (stenosis/reference external elastic membrane CSA). Long anatomic left main arteries (length > or =10 mm, n = 43) were compared with short anatomic left main arteries (length <10 mm, n = 44) regarding stenosis location. Ostial (proximal third of left main artery) (n = 32) and nonostial (midthird and distal third) stenoses (n = 55) were compared regarding stenosis morphology. Short anatomic left main arteries developed stenoses more frequently near the ostium (ostium 55%, bifurcation 38%). Conversely, long anatomic left main arteries developed stenoses more frequently near the bifurcation (ostium 18%, bifurcation 77%, p = 0.001). Ostial left main stenoses were more common in women (44% vs 20%, p = 0.02), had larger lumen area (6.2 +/- 2.2 vs 4.6 +/- 2.3 mm(2), p = 0.002), less plaque burden (62 +/- 15% vs 80 +/- 9%, p <0.0001), less calcification (arc = 78 +/- 65 degrees vs 195 +/- 101 degrees, p <0.0001), and more negative remodeling (remodeling index = 0.87 +/- 0.19 vs 1.01 +/- 0.21, p = 0.005) than nonostial left main stenoses. Most ostial left main stenoses were categorized as eccentric (97% vs 76%, p = 0.01). Short and long left main arteries develop stenoses at different locations. Stenosis morphology was significantly different in these 2 locations.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Ultrassonografia de Intervenção , Idoso , Distribuição de Qui-Quadrado , Angiografia Coronária , Vasos Coronários/anatomia & histologia , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Fatores de Risco
20.
Circulation ; 103(19): 2332-5, 2001 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-11352879

RESUMO

BACKGROUND: Intracoronary gamma-radiation reduces recurrent in-stent restenosis. Late thrombosis (>30 days after radiation therapy) is identified as a serious complication. The Washington Radiation for In-Stent Restenosis Trial (WRIST) PLUS, which involved 6 months of treatment with clopidogrel and aspirin, was designed to examine the efficacy and safety of prolonged antiplatelet therapy for the prevention of late thrombosis. METHODS AND RESULTS: A total of 120 consecutive patients with diffuse in-stent restenosis in native coronary arteries and vein grafts with lesions <80 mm underwent percutaneous coronary transluminal angioplasty, laser ablation, and/or rotational atherectomy. Additional stents were placed in 34 patients (28.3%). After the intervention, a closed-end lumen catheter was introduced into the artery, a ribbon with different trains of radioactive (192)Ir seeds was positioned to cover the treated site, and a dose of 14 Gy to 2 mm was prescribed. Patients were discharged with clopidogrel and aspirin for 6 months and followed angiographically and clinically. All patients but one tolerated the clopidogrel. The late occlusion and thrombosis rates were compared with the gamma-radiation-treated (n=125) and the placebo patients (n=126) from the WRIST and LONG WRIST studies (which involved only 1 month of antiplatelet therapy). At 6 months, the group receiving prolonged antiplatelet therapy had total occlusion and late thrombosis rates of 5.8% and 2.5%, respectively; these rates were lower than those in the active gamma-radiation group and similar to those in the placebo historical control group. CONCLUSIONS: Six months of clopidogrel and aspirin and a reduction in re-stenting for patients with in-stent restenosis treated with gamma-radiation is well tolerated and associated with a reduction in the late thrombosis rate compared with a similar cohort treated with only 1 month of clopidogrel and aspirin.


Assuntos
Doença das Coronárias/terapia , Inibidores da Agregação Plaquetária/uso terapêutico , Trombose/prevenção & controle , Ticlopidina/análogos & derivados , Ticlopidina/uso terapêutico , Idoso , Clopidogrel , Angiografia Coronária , Feminino , Seguimentos , Raios gama/efeitos adversos , Raios gama/uso terapêutico , Humanos , Masculino , Pessoa de Meia-Idade , Stents/efeitos adversos , Trombose/etiologia , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...