Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Hosp Infect ; 99(1): 94-97, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29191610

RESUMO

Infective endocarditis (IE) after transcatheter aortic valve implantation (TAVI) is a rare but severe complication. Among 326 patients who underwent TAVI at Grenoble Alpes University Hospital, six (1.8%) cases of IE and 11 (3.4%) cases of bacteraemia were identified. No cases of IE were linked to the intervention; one was due to Staphylococcus aureus despite a screening and targeted decolonization strategy. This underscores the need for randomized studies to evaluate the benefit and cost-effectiveness of this policy.


Assuntos
Bacteriemia/epidemiologia , Endocardite/complicações , Endocardite/epidemiologia , Hospitais Universitários , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Feminino , França/epidemiologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Infecções Estafilocócicas/epidemiologia , Staphylococcus aureus/isolamento & purificação
2.
J Hosp Infect ; 91(3): 244-9, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26341270

RESUMO

BACKGROUND: In spite of 25 recently built high-risk haematology rooms with a protected environment and fitted with en-suite bathrooms in our university hospital centre in 2008, sporadic cases of hospital-acquired invasive aspergillosis remained in these wards. AIM: This study aimed to identify unsuspected environmental sources of filamentous fungal contamination in these rooms. METHODS: Over two months, environmental fungal flora in the air (150 samples) as well as air particle counting and physical environmental parameters (airspeed, temperature, humidity, pressure) were prospectively monitored twice on the sampling day in all 25 protected rooms and en-suite bathrooms in use, and on bathroom surfaces (150 samples). FINDINGS: In rooms under laminar airflow, in the presence of patients during sampling sessions, fungi were isolated in two samples (4%, 2/50) with a maximum value of 2cfu/500L (none was Aspergillus sp.). However, 88% of the air samples (44/50) in the bathroom were contaminated with a median range and maximum value of 2 and 16cfu/500L. Aspergillus spp. were involved in 24% of contaminated samples (12/44) and A. fumigatus in 6% (3/44). Bathroom surfaces were contaminated by filamentous fungi in 5% of samples (8/150). CONCLUSION: This study highlighted that en-suite bathrooms in protected wards are likely to be a source of fungi. Before considering specific treatment of air in bathrooms, technicians have first corrected the identified deficiencies: replacement of high-efficiency particulate air filters, improvement of air control automation, and restoration of initial technical specifications. Assessment of measure effectiveness is planned.


Assuntos
Microbiologia Ambiental , Fungos/isolamento & purificação , Doenças Hematológicas/complicações , Micoses/epidemiologia , Isoladores de Pacientes , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , Feminino , Hospitais Universitários , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...