Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Radiat Isot ; 158: 108923, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32174381

RESUMO

The thermal neutron-induced gamma-ray background in 124Sn is investigated in connection with neutrinoless double beta decay (0νßß) studies in 124Sn. For this purpose, a 99.26% enriched 124Sn sample was irradiated with a thermal neutron fluence of 3×1015/cm2 in the Dhruva reactor at the Bhabha Atomic Research Centre, Mumbai. The gamma ray spectra of the irradiated sample were measured in a low background counting setup to study both long-lived and short-lived activities. The present data give an independent measurement of the half-life of 125Sn*(32+) and 125Sn(112-) as 10.01(8) min and 9.63(2) d, respectively. The impact of the observed high-energy gamma rays and the residual activity due to 125Sb, on the background in the region of interest around the Qßß value of 124Sn (~2.291 MeV) is discussed.

2.
Rev Sci Instrum ; 90(9): 096104, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31575278

RESUMO

This paper reports the detailed noise characterization, investigation of various noise sources, and its mitigation to improve the performance of a cryogenic bolometer detector for the TIN.TIN experiment. The noise spectrum has been measured for a sapphire bolometer test setup with an indigenously developed neutron transmutation doped Ge sensor in the cryogen free dilution refrigerator system at Mumbai. The effect of external noise, arising either from ground loops in the system or from the diagnostic and control electronics of the cryostat, on the performance of the bolometer is assessed. A systematic comparison of the influence of different noise pickups on the bolometer resolution is also presented. The best-achieved resolution (σE) at 15 mK is ∼15 keV for heater pulses and appears to be mainly limited by the noise due to the pulse tube cryocooler.

3.
Opt Lett ; 40(19): 4540-3, 2015 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-26421576

RESUMO

We demonstrate continuous wave (CW) terahertz generation from antennas fabricated on C12-irradiated semi-insulating (SI) GaAs substrates. The dark current drawn by the antennas fabricated on irradiated substrates is ∼3 to 4 orders of magnitude lower compared to antennas fabricated on un-irradiated substrates, while the photocurrents decrease by only ∼1.5 orders of magnitude. This can be attributed to the strong reduction of the carrier lifetime that is 2.5 orders of magnitude, with values around τ(rec)=0.2 ps. Reduced thermal heating allows for higher bias voltages to the irradiated antenna devices resulting in higher CW terahertz power, just slightly lower than that of low-temperature grown GaAs (LT GaAs)at similar excitation conditions.

4.
Opt Express ; 23(5): 6656-61, 2015 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-25836882

RESUMO

We report here a photoconductive material for THz detection with sub-picosecond carrier lifetime made by C(12) (Carbon) irradiation on commercially available semi-insulating (SI) GaAs. We are able to reduce the carrier lifetime of SI-GaAs down to sub-picosecond by irradiating it with various irradiation dosages of Carbon (C(12)) ions. With an increase of the irradiation dose from ~10(12) /cm(2) to ~10(15) /cm(2) the carrier lifetime of SI-GaAs monotonously decreases to 0.55 picosecond, whereas that of usual non-irradiated SI-GaAs is ~70 picosecond. This decreased carrier lifetime has resulted in a strong improvement in THz pulse detection compared with normal SI-GaAs. Improvement in signal to noise ratio as well as in detection bandwidth is observed. Carbon irradiated SI-GaAs appears to be an economical alternative to low temperature grown GaAs for fabrication of THz devices.

5.
Phys Rev Lett ; 111(6): 062502, 2013 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-23971569

RESUMO

An earlier measurement on the 4+ to 2+ radiative transition in 8Be provided the first electromagnetic signature of its dumbbell-like shape. However, the large uncertainty in the measured cross section does not allow a stringent test of nuclear structure models. This Letter reports a more elaborate and precise measurement for this transition, via the radiative capture in the 4He + 4He reaction, improving the accuracy by about a factor of 3. Ab initio calculations of the radiative transition strength with improved three-nucleon forces are also presented. The experimental results are compared with the predictions of the alpha cluster model and ab initio calculations.

6.
Phys Rev Lett ; 103(23): 232701, 2009 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-20366144

RESUMO

A modern variation of the Rutherford experiment to probe the tunneling of exotic nuclear matter from the measurement of the residues formed in the bombardment of (197)Au by extremely neutron-rich (8)He nuclei is presented. Using a novel off-beam technique the most precise and accurate measurements of fusion and neutron transfer involving reaccelerated unstable beams are reported. The results show unusual behavior of the tunneling of (8)He compared to that for lighter helium isotopes, highlighting the role of the intrinsic structure of composite many-body quantum systems and pairing correlations.

7.
Phys Rev Lett ; 103(23): 232702, 2009 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-20366145

RESUMO

Results of measurement of residues formed in fusion of (6)Li with (198)Pt in the energy range of 0.68 < E/V(b) < 1.3 using a new sensitive off-beam technique are reported. The fusion excitation function and the derived average angular momenta do not indicate a change of slope at deep sub-barrier energies, contrary to recent observations. The present results for a system with weakly bound projectile confront the current understanding of the fusion hindrance at these low energies, underlying the role of internal reorganization on the dynamical path towards fusion.

8.
Phys Rev Lett ; 101(3): 032701, 2008 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-18764247

RESUMO

Angular distributions for 1n and 2n transfer are reported for the 6He+65Cu system at E_{lab}=22.6 MeV. For the first time, triple coincidences between alpha particles, neutrons, and characteristic gamma rays from the targetlike residues were used to separate the contributions arising from 1n and 2n transfer. The differential cross sections for these channels, elastic scattering, and fusion were analyzed using a coupled reaction channels approach. The large measured ratio of the 2n-to-1n cross section and the strong influence of 2n transfer on other channels indicate that the dineutron configuration of 6He plays a dominant role in the reaction mechanism.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA