Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J AOAC Int ; 99(6): 1555-1564, 2016 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-27634328

RESUMO

A performance validation of the ANSR® for Campylobacter method was conducted in selected matrixes. This assay used selective nicking enzyme amplification technology to amplify target genes. Samples were enriched for 20 to 24 h and then lysed. The assay was completed within 50 min using real-time detection in a combination incubator/fluorescence detector and software. When 50 distinct strains of Campylobacter jejuni, C. lari, or C. coli were tested for inclusivity, all 50 strains produced positive results. In exclusivity testing, 31 strains of related organisms, including seven nontarget Campylobacter strains and other common species, were evaluated. All 31 species generated negative ANSR assay results, including the nontarget Campylobacter strains. The ANSR for Campylobacter method was compared to the U.S. Department of Agriculture, Food Safety and Inspection Service Microbiology Laboratory Guidebook reference method using naturally contaminated chicken carcass rinse or turkey carcass sponge samples. ANSR method performance was not statistically different from the reference method using two different enrichment options. Equivalent results were observed at both time points (20 and 24 h) and in both atmospheres (microaerobic and aerobic) to reference methods. Method performance with chicken carcass rinse was confirmed in an independent laboratory study. Additionally, in robustness testing, small, deliberate changes to the assay parameters minimally affected ANSR method performance. Finally, accelerated stability results from three independently manufactured lots supported a shelf life of 6 months when stored at 4°C. The ANSR assay offered greater efficiency and flexibility when compared to the reference method with a 20-24 h single-step enrichment in a microaerobic or an aerobic atmosphere.


Assuntos
Campylobacter/isolamento & purificação , Carne/microbiologia , Temperatura , Animais , Galinhas/microbiologia , Software , Espectrometria de Fluorescência , Perus/microbiologia
2.
J AOAC Int ; 99(3): 705-16, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27297839

RESUMO

A performance validation of the ANSR(®) for E. coli O157:H7 method was conducted in selected food matrixes. This assay uses selective nicking enzyme amplification technology to amplify target genes. Samples are enriched for 12-24 h and then lysed. The assay is completed within 40 min using real-time detection in a combination incubator/fluorescence detector and software. When 44 distinct strains of Escherichia coli O157:H7 and 6 strains of E. coli O157:NM were tested for inclusivity, all 50 strains produced positive results. In exclusivity testing, 57 strains representing 33 species of closely related Gram-negative bacteria belonging to the Enterobacteriaceae family, including 11 non-H7 O157 strains and shiga toxin-producing E. coli other than O157:H7, were evaluated. All 57 nontarget strains generated negative ANSR assay results. Using 80% lean ground beef and beef trim (approximately 20% fat), ANSR method performance was compared to the U.S. Department of Agriculture, Food Safety and Inspection Service Microbiology Laboratory Guidebook reference culture procedure. ANSR performance with baby spinach and sprout irrigation water was measured against the U.S. Food and Drug Administration Bacteriological Analytical Manual reference method. ANSR method performance was not statistically different to that of the reference methods using two different enrichment options. For ground beef and beef trim, the standard enrichment in modified Tryptone Soya Broth can be analyzed using the ANSR assay with a 1:10 dilution of the enrichment in phosphate-buffered saline and produces equivalent results to the reference method. Additionally, in most matrixes tested (exception is spinach which required 24 h enrichment) the assay offers great efficiency and flexibility over the reference method with a 12-24 h single-step enrichment. Equivalent results were observed at both time points (12 and 24 h) to reference methods. Small changes to the assay parameters minimally affected ANSR method performance. Finally, accelerated stability results from three independently manufactured lots support a shelf-life of 6 months when stored at 4°C.


Assuntos
Técnicas Bacteriológicas , Escherichia coli O157/isolamento & purificação , Software , Espectrometria de Fluorescência
3.
J AOAC Int ; 99(1): 98-111, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27053468

RESUMO

A study was conducted to validate minor reagent formulation, enrichment, and procedural changes to the ANSR(®) Listeria method, Performance-Tested Method(SM) 101202. In order to improve ease of use and diminish risk of amplicon contamination, the lyophilized reagent components were reformulated for increased solubility, thus eliminating the need to mix by pipetting. In the alternative procedure, an aliquot of the lysate is added to lyophilized ANSR reagents, immediately capped, and briefly mixed by vortexing. When three foods (hot dogs, Mexican-style cheese, and cantaloupe) and sponge samples taken from a stainless steel surface were tested, significant differences in performance between the ANSR and U.S. Food and Drug Administration Bacteriological Analytical Manual or U.S. Department of Agriculture, Food Safety and Inspection Service Microbiology Laboratory Guidebook reference culture procedures were seen with hot dogs and Mexican-style cheese after 16 h enrichment, with the reference methods producing more positive results. After 24 h enrichment, however, there were no significant differences in method performance for any of the four matrixes tested. Robustness testing was also conducted, with variations to lysis buffer volume, lysis time, and sample volume having no demonstrable effect on assay results. Accelerated stability testing was carried out over a 10-week period and showed no diminishment in assay performance. A second phase of the study examined performance of the ANSR assay following enrichment in a new medium, LESS Plus broth, designed for use with all food and environmental sample types. With the alternative LESS Plus broth, there were no significant differences in performance between the ANSR method and the reference culture procedures for any of the matrixes tested after either 16 or 24 h enrichment, although 24 h enrichment is recommended for hot dogs due to higher sensitivity. Results of inclusivity and exclusivity testing using LESS Plus broth showed that the ANSR assay is highly specific, with 100% expected results for target and nontarget bacteria.


Assuntos
Técnicas Bacteriológicas , Análise de Alimentos , Microbiologia de Alimentos , Listeria/isolamento & purificação , Kit de Reagentes para Diagnóstico , Estados Unidos
4.
J AOAC Int ; 99(1): 112-23, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26833248

RESUMO

Work was conducted to validate performance of the ANSR(®) for Listeria monocytogenes method in selected food and environmental matrixes. This DNA-based assay involves amplification of nucleic acid via an isothermal reaction based on nicking enzyme amplification technology. Following single-step sample enrichment for 16-24 h for most matrixes, the assay is completed in 40 min using only simple instrumentation. When 50 distinct strains of L. monocytogenes were tested for inclusivity, 48 produced positive results, the exceptions being two strains confirmed by PCR to lack the assay target gene. Forty-seven nontarget strains (30 species), including multiple non-monocytogenes Listeria species as well as non-Listeria, Gram-positive bacteria, were tested, and all generated negative ANSR assay results. Performance of the ANSR method was compared with that of the U.S. Department of Agriculture, Food Safety and Inspection Service Microbiology Laboratory Guidebook reference culture procedure for detection of L. monocytogenes in hot dogs, pasteurized liquid egg, and sponge samples taken from an inoculated stainless steel surface. In addition, ANSR performance was measured against the U.S. Food and Drug Administration Bacteriological Analytical Manual reference method for detection of L. monocytogenes in Mexican-style cheese, cantaloupe, sprout irrigation water, and guacamole. With the single exception of pasteurized liquid egg at 16 h, ANSR method performance as quantified by the number of positives obtained was not statistically different from that of the reference methods. Robustness trials demonstrated that deliberate introduction of small deviations to the normal assay parameters did not affect ANSR method performance. Results of accelerated stability testing conducted using two manufactured lots of reagents predicts stability at the specified storage temperature of 4°C of more than 1 year.


Assuntos
Técnicas Bacteriológicas , Microbiologia Ambiental , Análise de Alimentos , Microbiologia de Alimentos , Listeria monocytogenes/isolamento & purificação , Listeria monocytogenes/genética , Kit de Reagentes para Diagnóstico , Estados Unidos
5.
J AOAC Int ; 98(5): 1290-300, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26525248

RESUMO

ANSR® Listeria was previously certified as Performance Tested Method(SM) 101202 for detection of Listeria spp. on selected environmental surfaces. This study proposes a matrix extension to the method for detection of Listeria spp. in selected food matrixes. The method is an isothermal nucleic acid amplification assay based on the nicking enzyme amplification reaction technology. Following single-step sample enrichment for 16-24 h, the assay is completed in less than 50 min, requiring only simple instrumentation. Inclusivity testing was performed using a panel of 51 strains of Listeria spp., representing the species L. grayi, L. innocua, L. ivanovii, L. monocytogenes, L. seeligeri, and L. welshimeri. All strains tested were detected by the ANSR assay. Exclusivity testing of 30 strains representing non-Listeria Gram-positive bacteria yielded no evidence of cross-reactivity. Performance of the ANSR method for detection of Listeria spp. was compared to that of reference culture procedures for pasteurized liquid egg, pasteurized 2% milk, Mexican-style cheese, ice cream, smoked salmon, lettuce, cantaloupe, and guacamole. Data obtained in these unpaired studies and analyzed using a probability of detection model demonstrated that there were no statistically significant differences in results between the ANSR and reference culture methods, except for milk at 16 h and cantaloupe. In milk and smoked salmon, ANSR sensitivity was low at 16 h and therefore the recommended incubation time is 24 h. In cantaloupe, ANSR was found to be more sensitive than the reference culture method at both 16 and 24 h in independent laboratory testing. The ANSR Listeria method can be used as an accurate, rapid, and simple alternative to standard culture methods for detection of Listeria spp. in selected food types.


Assuntos
Análise de Alimentos/métodos , Contaminação de Alimentos/análise , Listeria/genética , Técnicas de Amplificação de Ácido Nucleico/normas , Laticínios/microbiologia , Ovos/microbiologia , Produtos Pesqueiros/microbiologia , Análise de Alimentos/instrumentação , Humanos , Desnaturação de Ácido Nucleico , Sensibilidade e Especificidade , Fatores de Tempo , Verduras/microbiologia
6.
J AOAC Int ; 96(4): 842-53, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24000759

RESUMO

ANSR Salmonella is a new molecular diagnostic assay for detection of Salmonella spp. in foods and environmental samples. The test is based on the nicking enzyme amplification reaction (NEAR) isothermal nucleic acid amplification technology. The assay platform features simple instrumentation, minimal labor, and, following a single-step 10-24 h enrichment (depending on sample type), an extremely short assay time of 30 min, including sample preparation. Detection is real-time using fluorescent molecular beacon probes. Inclusivity testing was performed using a panel of 113 strains of S. enterica and S. bongori, representing 109 serovars and all genetic subgroups. With the single exception of the rare serovar S. Weslaco, all serovars and genetic subgroups were detected. Exclusivity testing of 38 non-salmonellae, mostly Enterobacteriaceae, yielded no evidence of cross-reactivity. In comparative testing of chicken carcass rinse, raw ground turkey, raw ground beef, hot dogs, and oat cereal, there were no statistically significant differences in the number of positive results obtained with the ANSR and the U.S. Department of Agriculture-Food Safety and Inspection Service or U.S. Food and Drug Administration/Bacteriological Analytical Manual reference culture methods. In testing of swab or sponge samples from five different environmental surfaces, four trials showed no statistically significant differences in the number of positive results by the ANSR and the U.S. Food and Drug Administration/ Bacteriological Analytical Manual reference methods; in the trial with stainless steel surface, there were significantly more positive results by the ANSR method. Ruggedness experiments showed a high degree of assay robustness when deviations in reagent volumes and incubation times were introduced.


Assuntos
Microbiologia Ambiental , Microbiologia de Alimentos , Técnicas de Amplificação de Ácido Nucleico , Salmonella/isolamento & purificação , Kit de Reagentes para Diagnóstico , Reprodutibilidade dos Testes
7.
J AOAC Int ; 96(6): 1414-24, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24645523

RESUMO

ANSR Listeria is a new diagnostic assay for detection of Listeria spp. in sponge or swab samples taken from a variety of environmental surfaces. The method is an isothermal nucleic acid amplification assay based on the nicking enzyme amplification reaction technology. Following single-step sample enrichment for 16-24 h, the assay is completed in 40 min, requiring only simple instrumentation. In inclusivity testing, 48 of 51 Listeria strains tested positive, with only the three strains of L. grayi producing negative results. Further investigation showed that L. grayi is reactive in the ANSR assay, but its ability to grow under the selective enrichment conditions used in the method is variable. In exclusivity testing, 32 species of non-Listeria, Gram-positive bacteria all produced negative ANSR assay results. Performance of the ANSR method was compared to that of the U.S. Department of Agriculture-Food Safety and Inspection Service reference culture procedure for detection of Listeria spp. in sponge or swab samples taken from inoculated stainless steel, plastic, ceramic tile, sealed concrete, and rubber surfaces. Data were analyzed using Chi-square and probability of detection models. Only one surface, stainless steel, showed a significant difference in performance between the methods, with the ANSR method producing more positive results. Results of internal trials were supported by findings from independent laboratory testing. The ANSR Listeria method can be used as an accurate, rapid, and simple alternative to standard culture methods for detection of Listeria spp. in environmental samples.


Assuntos
Microbiologia Ambiental , Microbiologia de Alimentos/métodos , Listeria/metabolismo , Técnicas de Amplificação de Ácido Nucleico/métodos , Algoritmos , Técnicas Bacteriológicas/métodos , Monitoramento Ambiental/métodos , Listeria/genética , Kit de Reagentes para Diagnóstico , Reprodutibilidade dos Testes , Software , Aço Inoxidável , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...