Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
AJNR Am J Neuroradiol ; 33(1): 69-76, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22095961

RESUMO

BACKGROUND AND PURPOSE: Quantifying MVA rather than MVD provides better correlation with survival in HGG. This is attributed to a specific "glomeruloid" vascular pattern, which is better characterized by vessel area than number. Despite its prognostic value, MVA quantification is laborious and clinically impractical. The DSC-MR imaging measure of rCBV offers the advantages of speed and convenience to overcome these limitations; however, clinical use of this technique depends on establishing accurate correlations between rCBV, MVA, and MVD, particularly in the setting of heterogeneous vascular size inherent to human HGG. MATERIALS AND METHODS: We obtained preoperative 3T DSC-MR imaging in patients with HGG before stereotactic surgery. We histologically quantified MVA, MVD, and vascular size heterogeneity from CD34-stained 10-µm sections of stereotactic biopsies, and we coregistered biopsy locations with localized rCBV measurements. We statistically correlated rCBV, MVA, and MVD under conditions of high and low vascular-size heterogeneity and among tumor grades. We correlated all parameters with OS by using Cox regression. RESULTS: We analyzed 38 biopsies from 24 subjects. rCBV correlated strongly with MVA (r = 0.83, P < .0001) but weakly with MVD (r = 0.32, P = .05), due to microvessel size heterogeneity. Among samples with more homogeneous vessel size, rCBV correlation with MVD improved (r = 0.56, P = .01). OS correlated with both rCBV (P = .02) and MVA (P = .01) but not with MVD (P = .17). CONCLUSIONS: rCBV provides a reliable estimation of tumor MVA as a biomarker of glioma outcome. rCBV poorly estimates MVD in the presence of vessel size heterogeneity inherent to human HGG.


Assuntos
Neoplasias Encefálicas/patologia , Neoplasias Encefálicas/cirurgia , Glioma/patologia , Glioma/cirurgia , Angiografia por Ressonância Magnética/métodos , Microvasos/patologia , Recidiva Local de Neoplasia/patologia , Adulto , Determinação do Volume Sanguíneo , Neoplasias Encefálicas/irrigação sanguínea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/irrigação sanguínea , Recidiva Local de Neoplasia/prevenção & controle , Neovascularização Patológica/patologia , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estatística como Assunto , Técnicas Estereotáxicas , Resultado do Tratamento
2.
AJNR Am J Neuroradiol ; 31(1): 40-8, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19749223

RESUMO

BACKGROUND AND PURPOSE: Relative cerebral blood volume (rCBV) accuracy can vary substantially depending on the dynamic susceptibility-weighted contrast-enhanced (DSC) acquisition and postprocessing methods, due to blood-brain barrier disruption and resulting T1-weighted leakage and T2- and/or T2*-weighted imaging (T2/T2*WI) residual effects. We set out to determine optimal DSC conditions that address these errors and maximize rCBV accuracy in differentiating posttreatment radiation effect (PTRE) and tumor. MATERIALS AND METHODS: We recruited patients with previously treated high-grade gliomas undergoing image-guided re-resection of recurrent contrast-enhancing MR imaging lesions. Thirty-six surgical tissue samples were collected from 11 subjects. Preoperative 3T DSC used 6 sequential evenly timed acquisitions, each by using a 0.05-mmol/kg gadodiamide bolus. Preload dosing (PLD) and baseline subtraction (BLS) techniques corrected T1-weighted leakage and T2/T2*WI residual effects, respectively. PLD amount and incubation time increased with each sequential acquisition. Corresponding tissue specimen stereotactic locations were coregistered to DSC to measure localized rCBV under varying PLD amounts, incubation times, and the presence of BLS. rCBV thresholds were determined to maximize test accuracy (average of sensitivity and specificity) in distinguishing tumor (n = 21) and PTRE (n = 15) samples under the varying conditions. Receiver operator characteristic (ROC) areas under the curve (AUCs) were statistically compared. RESULTS: The protocol that combined PLD (0.1-mmol/kg amount, 6-minute incubation time) and BLS correction methods maximized test AUC (0.99) and accuracy (95.2%) compared with uncorrected rCBV AUC (0.85) and accuracy (81.0%) measured without PLD and BLS (P = .01). CONCLUSIONS: Combining PLD and BLS correction methods for T1-weighted and T2/T2*WI errors, respectively, enables highly accurate differentiation of PTRE and tumor growth.


Assuntos
Neoplasias Encefálicas/diagnóstico , Neoplasias Encefálicas/cirurgia , Glioma/diagnóstico , Glioma/cirurgia , Angiografia por Ressonância Magnética/métodos , Angiografia por Ressonância Magnética/normas , Adulto , Neoplasias Encefálicas/patologia , Feminino , Glioma/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...