Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 79
Filtrar
1.
eNeuro ; 11(6)2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38844346

RESUMO

In measurement, a reference frame is needed to compare the measured object to something already known. This raises the neuroscientific question of which reference frame is used by humans when exploring the environment. Previous studies suggested that, in touch, the body employed as measuring tool also serves as reference frame. Indeed, an artificial modification of the perceived dimensions of the body changes the tactile perception of external object dimensions. However, it is unknown if such a change in tactile perception would occur when the body schema is modified through the illusion of owning a limb altered in size. Therefore, employing a virtual hand illusion paradigm with an elongated forearm of different lengths, we systematically tested the subjective perception of distance between two points [tactile distance perception (TDP) task] on the corresponding real forearm following the illusion. Thus, the TDP task is used as a proxy to gauge changes in the body schema. Embodiment of the virtual arm was found significantly greater after the synchronous visuotactile stimulation condition compared with the asynchronous one, and the forearm elongation significantly increased the TDP. However, we did not find any link between the visuotactile-induced ownership over the elongated arm and TDP variation, suggesting that vision plays the main role in the modification of the body schema. Additionally, significant effect of elongation found on TDP but not on proprioception suggests that these are affected differently by body schema modifications. These findings confirm the body schema malleability and its role as a reference frame in touch.


Assuntos
Percepção de Distância , Ilusões , Percepção do Tato , Realidade Virtual , Humanos , Feminino , Masculino , Percepção do Tato/fisiologia , Adulto Jovem , Adulto , Ilusões/fisiologia , Percepção de Distância/fisiologia , Propriocepção/fisiologia , Imagem Corporal , Antebraço/fisiologia
4.
Clin Neurophysiol ; 156: 98-105, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37918223

RESUMO

OBJECTIVE: To evaluate cortical circuits and excitability of the motor cortex in the hemisphere contralateral to the affected (AH) and to the unaffected arm (UH), in upper limb amputees. METHODS: Motor evoked potentials (MEP) were recorded in 17 subjects who had upper limb amputation: 11 trans-radial (TR) and 6 trans-humeral (TH). Motor thresholds (MT), short interval intracortical inhibition (SICI), and interhemispheric inhibition (IHI) in the available arm muscles of the stump were evaluated. RESULTS: There was no significant difference in MT between hemispheres. SICI was preserved in TR but not in TH group. Additionally, in the TR group, the MEP amplitudes in AH were higher than in UH. A significant IHI was observed in the whole sample but not in each hemisphere or patient group. CONCLUSIONS: In our population of TR amputees, we found increased corticospinal excitability in the AH with preserved intracortical inhibition. This finding was not observed in the TH population. SIGNIFICANCE: Understanding the changes in intracortical excitability in amputees may enhance knowledge of the functional reorganization of the brain in the post-amputation phase, bringing useful information for prosthetic rehabilitation.


Assuntos
Amputados , Córtex Motor , Humanos , Braço , Estimulação Magnética Transcraniana , Amputação Cirúrgica , Potencial Evocado Motor/fisiologia , Inibição Neural/fisiologia
5.
J Neuroeng Rehabil ; 20(1): 118, 2023 09 09.
Artigo em Inglês | MEDLINE | ID: mdl-37689701

RESUMO

Proprioception plays a key role in moving our body dexterously and effortlessly. Nevertheless, the majority of investigations evaluating the benefits of providing supplemental feedback to prosthetics users focus on delivering touch restitution. These studies evaluate the influence of touch sensation in an attempt to improve the controllability of current robotic devices. Contrarily, investigations evaluating the capabilities of proprioceptive supplemental feedback have yet to be comprehensively analyzed to the same extent, marking a major gap in knowledge within the current research climate. The non-invasive strategies employed so far to restitute proprioception are reviewed in this work. In the absence of a clearly superior strategy, approaches employing vibrotactile, electrotactile and skin-stretch stimulation achieved better and more consistent results, considering both kinesthetic and grip force information, compared with other strategies or any incidental feedback. Although emulating the richness of the physiological sensory return through artificial feedback is the primary hurdle, measuring its effects to eventually support the integration of cumbersome and energy intensive hardware into commercial prosthetic devices could represent an even greater challenge. Thus, we analyze the strengths and limitations of previous studies and discuss the possible benefits of coupling objective measures, like neurophysiological parameters, as well as measures of prosthesis embodiment and cognitive load with behavioral measures of performance. Such insights aim to provide additional and collateral outcomes to be considered in the experimental design of future investigations of proprioception restitution that could, in the end, allow researchers to gain a more detailed understanding of possibly similar behavioral results and, thus, support one strategy over another.


Assuntos
Membros Artificiais , Humanos , Propriocepção , Cinestesia , Neurofisiologia , Manejo da Dor
6.
Neurosci Biobehav Rev ; 153: 105351, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37544389

RESUMO

Our interaction with the world rests on the knowledge that we are a body in space and time, which can interact with the environment. This awareness is usually referred to as sense of embodiment. For the good part of the past 30 years, the rubber hand illusion (RHI) has been a prime tool to study embodiment in healthy and people with a variety of clinical conditions. In this paper, we provide a critical overview of this research with a focus on the RHI paradigm as a tool to study prothesis embodiment in individuals with amputation. The RHI relies on well-documented multisensory integration mechanisms based on sensory precision, where parietal areas are involved in resolving the visuo-tactile conflict, and premotor areas in updating the conscious bodily representation. This mechanism may be transferable to prosthesis ownership in amputees. We discuss how these results might transfer to technological development of sensorised prostheses, which in turn might progress the acceptability by users.

7.
Front Psychol ; 14: 1190103, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37397340

RESUMO

"Crossmodal correspondences" are the consistent mappings between perceptual dimensions or stimuli from different sensory domains, which have been widely observed in the general population and investigated by experimental psychologists in recent years. At the same time, the emerging field of human movement augmentation (i.e., the enhancement of an individual's motor abilities by means of artificial devices) has been struggling with the question of how to relay supplementary information concerning the state of the artificial device and its interaction with the environment to the user, which may help the latter to control the device more effectively. To date, this challenge has not been explicitly addressed by capitalizing on our emerging knowledge concerning crossmodal correspondences, despite these being tightly related to multisensory integration. In this perspective paper, we introduce some of the latest research findings on the crossmodal correspondences and their potential role in human augmentation. We then consider three ways in which the former might impact the latter, and the feasibility of this process. First, crossmodal correspondences, given the documented effect on attentional processing, might facilitate the integration of device status information (e.g., concerning position) coming from different sensory modalities (e.g., haptic and visual), thus increasing their usefulness for motor control and embodiment. Second, by capitalizing on their widespread and seemingly spontaneous nature, crossmodal correspondences might be exploited to reduce the cognitive burden caused by additional sensory inputs and the time required for the human brain to adapt the representation of the body to the presence of the artificial device. Third, to accomplish the first two points, the benefits of crossmodal correspondences should be maintained even after sensory substitution, a strategy commonly used when implementing supplementary feedback.

8.
PLoS One ; 18(6): e0286566, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37289675

RESUMO

Somatosensation greatly increases the ability to control our natural body. This suggests that supplementing vision with haptic sensory feedback would also be helpful when a user aims at controlling a robotic arm proficiently. However, whether the position of the robot and its continuous update should be coded in a extrinsic or intrinsic reference frame is not known. Here we compared two different supplementary feedback contents concerning the status of a robotic limb in 2-DoFs configuration: one encoding the Cartesian coordinates of the end-effector of the robotic arm (i.e., Task-space feedback) and another and encoding the robot joints angles (i.e., Joint-space feedback). Feedback was delivered to blindfolded participants through vibrotactile stimulation applied on participants' leg. After a 1.5-hour training with both feedbacks, participants were significantly more accurate with Task compared to Joint-space feedback, as shown by lower position and aiming errors, albeit not faster (i.e., similar onset delay). However, learning index during training was significantly higher in Joint space feedback compared to Task-space feedback. These results suggest that Task-space feedback is probably more intuitive and more suited for activities which require short training sessions, while Joint space feedback showed potential for long-term improvement. We speculate that the latter, despite performing worse in the present work, might be ultimately more suited for applications requiring long training, such as the control of supernumerary robotic limbs for surgical robotics, heavy industrial manufacturing, or more generally, in the context of human movement augmentation.


Assuntos
Robótica , Humanos , Robótica/métodos , Retroalimentação , Movimento/fisiologia , Retroalimentação Sensorial/fisiologia , Extremidades
9.
Foods ; 12(7)2023 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-37048375

RESUMO

Although GM food production is considered an important strategy to meet the growing food needs of the population around the world, a majority of the GM food consumers express doubts about purchasing and eating them. However, it can be argued that consumers have different opinions about GM foods and their influence on human health and the natural environment. GM food producer Corporate Social Responsibility (CSR) may significantly affect such opinions, but the effect of this variable has been partially neglected in previous research studies. To address this gap, the present study investigates Iranian consumers' concerns about GM foods, trust in these products, and perception of GM food producer CSR as determinants of attitudes towards GM food. Data were collected from Iranian consumers. A cross-sectional survey research with a multi-stage random sampling approach was employed to capture the responses of 372 Iranian consumers. The results showed that consumers have both negative and positive attitudes towards GM foods. Perceived social equity, trust, and health concerns were the most important determinants of attitude towards GM foods. According to the results, these variables could account for 52.9% (Cox and Snell R2) and up to 70.6% (Nagelkerke R2) of the variance of the dependent variable. Furthermore, results revealed statistically significant differences among the consumers with different educational levels in terms of perceived social equity, perceived environmental responsibility, and environmental concern. The research contributes to the body of knowledge in GM food consumption by evolving the CSR to assess attitudes of users concerning GM foods.

10.
Front Neurorobot ; 17: 1130770, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37009638

RESUMO

Introduction: Robotic therapy allow to propose sessions of controlled and identical exercises, customizing settings, and characteristics on the individual patient. The effectiveness of robotic assisted therapy is still under study and the use of robots in clinical practice is still limited. Moreover, the possibility of treatment at home allows to reduce the economic costs and time to be borne by the patient and the caregiver and is a valid tool during periods of pandemic such as covid. The aim of this study is to assess whether a robotic home-based treatment rehabilitation using the iCONE robotic device has effects on a stroke population, despite the chronic condition of patients involved and the absence of a therapist next to the patient while performing the exercises. Materials and methods: All patients underwent an initial (T0) and final (T1) assessment with the iCONE robotic device and clinical scales. After T0 evaluation, the robot was delivered to the patient's home for 10 days of at-home treatment (5 days a week for 2 weeks). Results: Comparison between T0 and T1 evaluations revealed some significant improvements in robot-evaluated indices such as Independence and Size for the Circle Drawing exercise and Movement Duration for Point-to-Point exercise, but also in the MAS of the elbow. From the analysis of the acceptability questionnaire, a general appreciation of the robot emerged: patients spontaneously asked for the addition of further sessions and to continue therapy. Discussion: Telerehabilitation of patients suffering from a chronic stroke is an area that is still little explored. From our experience, this is one of the first studies to carry out a telerehabilitation with these characteristics. The use of robots can become a method to reduce the rehabilitation health costs, to ensure continuity of care, and to arrive in more distant places or where the availability of resources is limited. Conclusion: From the data obtained, this rehabilitation seems to be promising for this population. Moreover, promoting the recovery of the upper limb, iCONE can improve patient's quality of life. It would be interesting to conduct RCT studies to compare a conventional treatment in structure with a robotic telematics treatment.

11.
Sci Rep ; 13(1): 6789, 2023 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-37100797

RESUMO

Pointing at a screen using wrist and forearm movements is a kinematically redundant task, and the Central Nervous System seems to manage this redundancy by using a simplifying strategy, named Donders' Law for the wrist. In this work we investigated (1) whether this simplifying approach is stable over time and (2) whether a visuomotor perturbation provided in the task space influences the strategy used to solve the redundancy problem. We conducted two experiments asking participants to perform the same pointing task in four different days (first experiment), and providing a visual perturbation, i.e. a visuomotor rotation to the controlled cursor (second experiment), while recording their wrist and forearm rotations. Results showed that the participant-specific wrist redundancy management (described by the Donders' surfaces) (1) neither changes over time (2) nor varies when a visuomotor perturbation is provided in the task space.


Assuntos
Movimento , Punho , Humanos , Punho/fisiologia , Fenômenos Biomecânicos/fisiologia , Movimento/fisiologia , Antebraço/fisiologia , Articulação do Punho , Desempenho Psicomotor/fisiologia
12.
Neurosci Lett ; 804: 137212, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36966962

RESUMO

Auditory white noise (WN) is widely used in daily life for inducing sleep, and in neuroscience to mask unwanted environmental noise and cues. However, WN was recently reported to influence corticospinal excitability and behavioral performance. Here, we expand previous preliminary findings on the influence of WN exposure on cortical functioning, and we hypothesize that it may modulate cortical connectivity. We tested our hypothesis by performing magnetoencephalography in 20 healthy subjects. WN reduces cortical connectivity of the primary auditory and motor regions with very distant cortical areas, showing a right lateralized connectivity reduction for primary motor cortex. The present results, together with previous finding concerning WN impact on corticospinal excitability and behavioral performance, further support the role of WN as a modulator of cortical function. This suggest avoiding its unrestricted use as a masking tool, while purposely designed and controlled WN application could be exploited to harness brain function and to treat neuropsychiatric conditions.


Assuntos
Córtex Auditivo , Córtex Motor , Humanos , Ruído , Magnetoencefalografia/métodos , Sinais (Psicologia)
13.
Psychol Rep ; 126(3): 1322-1338, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35147062

RESUMO

PURPOSE: Employing a hierarchical model of personality, prior research suggests that cardinal traits such as conscientiousness and agreeability predict central traits such as materialism and need for arousal that in turn impact surface traits such as onychophagia and compulsive buying. More research is needed to explore additional central traits and their effect on onychophagia and compulsive buying. Thus, the goal of the current research is to examine how another central trait-negative perfectionism-impacts onychophagia and compulsive buying. DESIGN/METHODOLOGY/APPROACH: A survey was administered both online and face-to-face resulting in a sample of 634 subjects of which 391 were individuals with onychophagia. Through a multi-group analysis, a causal model was tested to identify personality traits and their relationship with compulsive buying. RESULTS: Results showed that onychophagia was affected by other obsessive-compulsive disorders-particularly trichotillomania, and excoriation disorder, which significantly increased the likelihood that the participant was a compulsive buyer.


Assuntos
Hábito de Roer Unhas , Transtorno Obsessivo-Compulsivo , Humanos , Comportamento Compulsivo/diagnóstico , Transtornos da Personalidade , Transtorno Obsessivo-Compulsivo/diagnóstico , Personalidade
14.
Clin Neurophysiol ; 144: 135-141, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36210268

RESUMO

OBJECTIVE: Sensorimotor integration is a crucial process for adaptive behaviour and can be explored non-invasively with a conditioned transcranial magnetic stimulation (TMS) paradigm - i.e. short-latency afferent inhibition (SAI). To gain insight into the sensorimotor integration phenomenon, we used two different approaches to combine peripheral and cortical stimulation in the SAI paradigm, measuring not only the latency of low frequency somatosensory evoked potentials (SEPs) but also the peaks of high frequency oscillations (HFOs) underlying SEPs. METHODS: The interstimulus intervals (ISIs) between the electrical stimulation of the median nerve and the motor cortex magnetic stimulation were determined relative to the latency of the earliest SEPs cortical potential (N20) or the HFOs peaks. In particular, the first and last negative and positive peaks of HFOs were extracted through a custom-made MATLAB script. RESULTS: Thirty-three healthy subjects participated in this study. We found out that muscle responses after TMS were suppressed when ISIs were comprised between -1 to +3 ms relative to the N20 peak and at all ISIs relative to HFOs peaks, except for the first negative peak. CONCLUSIONS: Coupling peripheral and cortical stimulation at early interstimulus intervals - before the SEPs N20 peak - may modulate muscle response. SIGNIFICANCE: Our findings confirm that afferent inhibition is produced both through a direct (thalamus-motor cortex) and indirect (thalamus-somatosensory-motor cortex) pathway.


Assuntos
Potencial Evocado Motor , Córtex Motor , Humanos , Potencial Evocado Motor/fisiologia , Inibição Neural/fisiologia , Estimulação Magnética Transcraniana , Córtex Motor/fisiologia , Potenciais Somatossensoriais Evocados/fisiologia , Nervo Mediano/fisiologia , Estimulação Elétrica , Vias Aferentes/fisiologia
15.
Sci Rep ; 12(1): 13108, 2022 07 30.
Artigo em Inglês | MEDLINE | ID: mdl-35907889

RESUMO

Auditory white noise (WN) is widely used in neuroscience to mask unwanted environmental noise and cues, e.g. TMS clicks. However, to date there is no research on the influence of WN on corticospinal excitability and potentially associated sensorimotor integration itself. Here we tested the hypothesis, if WN induces M1 excitability changes and improves sensorimotor performance. M1 excitability (spTMS, SICI, ICF, I/O curve) and sensorimotor reaction-time performance were quantified before, during and after WN stimulation in a set of experiments performed in a cohort of 61 healthy subjects. WN enhanced M1 corticospinal excitability, not just during exposure, but also during silence periods intermingled with WN, and up to several minutes after the end of exposure. Two independent behavioural experiments highlighted that WN improved multimodal sensorimotor performance. The enduring excitability modulation combined with the effects on behaviour suggest that WN might induce neural plasticity. WN is thus a relevant modulator of corticospinal function; its neurobiological effects should not be neglected and could in fact be exploited in research applications.


Assuntos
Potencial Evocado Motor , Córtex Motor , Acústica , Potencial Evocado Motor/fisiologia , Humanos , Córtex Motor/fisiologia , Plasticidade Neuronal , Estimulação Magnética Transcraniana
16.
Open Res Eur ; 1: 55, 2022 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-35747768

RESUMO

Background: The autonomic nervous system is the main determinant of the blood flow directed towards a body part, and it is tightly connected to the representation of the body in the brain; would the experimental modulation of the sense of limb ownership affect its blood perfusion? Methods: In healthy participants, we employed the rubber hand illusion paradigm to modulate limb ownership while we monitored the brachial artery blood flow and resistance index within the investigated limb. Results: In all conditions with brush-stroking, we found an initial drop in the blood flow due to tactile stimulation. Subsequently, in the illusion condition (where both the rubber and real hand synchronous brush-stroking were present), the blood flow rose significantly faster and reached significantly higher values. Moreover, the increase in blood flow correlated with the extent of embodiment as measured by questionnaires and correlated negatively with the change of peripherical vascular resistance. Conclusions: These findings suggest that modulating the representation of a body part impacts its blood perfusion.

17.
Artif Organs ; 46(10): 2034-2043, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35704435

RESUMO

BACKGROUND: Providing real-time haptic feedback is an important, but still not sufficiently explored aspect of the use of supernumerary robotic limbs (SRLs). We present a multi-pad electrode for conveying multi-modal proprioceptive and sensory information from SRL to the user's thigh and propose a method for stimuli calibration. METHODS: Within two pilot tests, we investigated return electrode configuration and active electrode discrimination in three healthy subjects to select the appropriate electrode pad topology. Based on the obtained results and anthropometric data from the literature, the electrode was designed to have three branches of 10 pads and two additional pads that can be displaced over/under the electrode branches. The electrode was designed to be connected to the stimulator that allows full multiplexing so that specific branches can serve as a common return electrode. To define the procedure for application of this system, the sensation, localization, and discomfort thresholds applicable for the novel electrode were determined and analyzed in 10 subjects. RESULTS: The results showed no overlaps between the three thresholds for individual pads, with significantly different average values, suggesting that the selected electrode positioning and design provide a good active range of useful current amplitude. The results of the subsequent analysis suggested that the stimuli intensity level of 200% of the sensation threshold is the most probable value of the localization threshold. Furthermore, this level ensures a low chance (i.e., 0.7%) of reaching the discomfort. CONCLUSIONS: We believe that envisioned electrotactile system could serve as a high bandwidth feedback channel that can be easily set up to provide proprioceptive and sensory feedback from supernumerary limbs.


Assuntos
Procedimentos Cirúrgicos Robóticos , Estimulação Elétrica , Eletrodos , Retroalimentação , Retroalimentação Sensorial , Humanos , Tato
18.
Molecules ; 27(10)2022 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-35630604

RESUMO

Invasive intraneural electrodes can control advanced neural-interfaced prostheses in human amputees. Nevertheless, in chronic implants, the progressive formation of a fibrotic capsule can gradually isolate the electrode surface from the surrounding tissue leading to loss of functionality. This is due to a nonspecific inflammatory response called foreign-body reaction (FBR). The commonly used poly(ethylene glycol) (PEG)-based low-fouling coatings of implantable devices can be easily encapsulated and are susceptible to oxidative damage in long-term in vivo applications. Recently, sulfobetaine-based zwitterionic hydrogels have emerged as an important class of robust ultra-low fouling biomaterials, holding great potential to mitigate FBR. The aim of this proof-of-principle in vitro work was to assess whether the organic zwitterionic-poly(sulfobetaine methacrylate) [poly(SBMA)]-hydrogel could be a suitable coating for Polyimide (PI)-based intraneural electrodes to reduce FBR. We first synthesized and analyzed the hydrogel through a mechanical characterization (i.e., Young's modulus). Then, we demonstrated reduced adhesion and activation of fibrogenic and pro-inflammatory cells (i.e., human myofibroblasts and macrophages) on the hydrogel compared with PEG-coated and polystyrene surfaces using cell viability assays, confocal fluorescence microscopy and high-content analysis of oxidative stress production. Interestingly, we successfully coated PI surfaces with a thin film of the hydrogel through covalent bond and demonstrated its high hydrophilicity via water contact angle measurement. Importantly, we showed the long-term release of an anti-fibrotic drug (i.e., Everolimus) from the hydrogel. Because of the low stiffness, biocompatibility, high hydration and ultra-low fouling characteristics, our zwitterionic hydrogel could be envisioned as long-term diffusion-based delivery system for slow and controlled anti-inflammatory and anti-fibrotic drug release in vivo.


Assuntos
Reação a Corpo Estranho , Hidrogéis , Eletrodos , Reação a Corpo Estranho/prevenção & controle , Humanos , Hidrogéis/química , Metacrilatos/química , Polietilenoglicóis/química
19.
Nat Commun ; 13(1): 1345, 2022 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-35292665

RESUMO

Augmenting the body with artificial limbs controlled concurrently to one's natural limbs has long appeared in science fiction, but recent technological and neuroscientific advances have begun to make this possible. By allowing individuals to achieve otherwise impossible actions, movement augmentation could revolutionize medical and industrial applications and profoundly change the way humans interact with the environment. Here, we construct a movement augmentation taxonomy through what is augmented and how it is achieved. With this framework, we analyze augmentation that extends the number of degrees-of-freedom, discuss critical features of effective augmentation such as physiological control signals, sensory feedback and learning as well as application scenarios, and propose a vision for the field.


Assuntos
Membros Artificiais , Retroalimentação Sensorial/fisiologia , Humanos , Aprendizagem/fisiologia , Movimento
20.
J Physiol ; 600(6): 1497-1514, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34921406

RESUMO

The integration of sensory inputs in the motor cortex is crucial for dexterous movement. We recently demonstrated that a closed-loop control based on the feedback provided through intraneural multichannel electrodes implanted in the median and ulnar nerves of a participant with upper limb amputation improved manipulation skills and increased prosthesis embodiment. Here we assessed, in the same participant, whether and how selective intraneural sensory stimulation also elicits a measurable cortical activation and affects sensorimotor cortical circuits. After estimating the activation of the primary somatosensory cortex evoked by intraneural stimulation, sensorimotor integration was investigated by testing the inhibition of primary motor cortex (M1) output to transcranial magnetic stimulation, after both intraneural and perineural stimulation. Selective sensory intraneural stimulation evoked a low-amplitude, 16 ms-latency, parietal response in the same area of the earliest component evoked by whole-nerve stimulation, compatible with fast-conducting afferent fibre activation. For the first time, we show that the same intraneural stimulation was also capable of decreasing M1 output, at the same time range of the short-latency afferent inhibition effect of whole-nerve superficial stimulation. The inhibition generated by the stimulation of channels activating only sensory fibres was stronger than that due to intraneural or perineural stimulation of channels activating mixed fibres. We demonstrate in a human subject that the cortical sensorimotor integration inhibiting M1 output previously described after the experimental whole-nerve stimulation is present also with a more ecological selective sensory fibre stimulation. KEY POINTS: Cortical integration of sensory inputs is crucial for dexterous movement. Short-latency somatosensory afferent inhibition of motor cortical output is typically produced by peripheral whole-nerve stimulation. We exploited intraneural multichannel electrodes used to provide sensory feedback for prosthesis control to assess whether and how selective intraneural sensory stimulation affects sensorimotor cortical circuits in humans. Activation of the primary somatosensory cortex (S1) was explored by recording scalp somatosensory evoked potentials. Sensorimotor integration was tested by measuring the inhibitory effect of the afferent stimulation on the output of the primary motor cortex (M1) generated by transcranial magnetic stimulation. We demonstrate in humans that selective intraneural sensory stimulation elicits a measurable activation of S1 and that it inhibits the output of M1 at the same time range of whole-nerve superficial stimulation.


Assuntos
Córtex Motor , Estimulação Elétrica , Potencial Evocado Motor/fisiologia , Potenciais Somatossensoriais Evocados/fisiologia , Humanos , Córtex Motor/fisiologia , Movimento , Córtex Somatossensorial/fisiologia , Estimulação Magnética Transcraniana
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...