Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 95(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38421260

RESUMO

A soft x-ray varied-line-spacing (VLS) laminar-type spherical grating with a super-mirror-type (SMT) multilayer was designed for a soft x-ray high resolution flat-field spectrograph in a region of 2-4 keV. The effective groove density of the designed VLS grating is 3200 lines/mm, and the local groove density varies from 2700 to 3866 lines/mm. The geometrical imaging property was evaluated by numerical calculations. The resolving power estimated by means of ray tracing was up to ∼103. For the evaluation of diffraction efficiency, the SMT multilayer structure designed for 3200 lines/mm in our previous work, Koike et al., Rev. Sci. Instrum. 94, 045109 (2023), was employed, and the numerical calculation was performed considering the local groove density of VLS grooves and the local incidence angle being affected by the curvature of the spherical surface and the geometrical relation between the source and incidence point on the grating. The results showed that the SMT multilayer-coated grating exhibited about an order of magnitude higher diffraction efficiency compared with an Au-coated grating.

2.
Rev Sci Instrum ; 94(4)2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38081245

RESUMO

Soft x-ray diffraction gratings coated with a supermirror-type multilayer were designed to enhance diffraction efficiency in the energy range of 2-4 keV by means of numerical calculations. The optimized groove depth and incidence angle are 2.05 nm and 88.65°, respectively, for the grating having a groove density of 3200 grooves/mm. Regarding the multilayer structure, the optimum number of B4C/W layers pair was 11 and the thickness of B4C was increased from bottom to top, while that of W was kept constant. The replacement of the top layer of W by either Co, Cr, or Ni was an effective means of obtaining uniform diffraction efficiency. In the region of 2-4 keV, the calculated diffraction efficiency of the designed gratings was up to ∼5.3%, on average, and almost eight times larger than that of ∼0.7% of an Au coated grating.

3.
Rev Sci Instrum ; 94(12)2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38156956

RESUMO

Laminar-type spherical diffraction gratings overcoated with carbon-based materials were designed, fabricated, and evaluated for the purpose of enhancing the analytical sensitivity of the flat-field spectrograph in a vacuum ultraviolet region of 35-110 eV. As the design benchmark for numerical calculations, diffraction efficiency (DE) and spectral flux, which are defined by the product of the DE and numerical aperture and correlate with the analytical sensitivity of the spectrograph, were used. To simplify the feasibility study on the overcoating effects, we assumed a laminar-type grating having a grating constant of 1/1000 mm and coated with a Au layer of 30.0 nm thickness and an incidence angle of 84.0°. The optimized groove depth and duty ratio were 30.0 nm and 0.3, respectively. In addition, the optimum thicknesses of the overcoating layer were 44, 46, 24, and 30 nm for B4C, C, diamond-like-carbon, and SiC, respectively. Based on these results, we have fabricated a varied-line-spacing holographic grating overcoated with B4C with a thickness of 47 nm. For the experimental evaluation, we used the light source of Mg-L and Al-L emissions excited by the electron beam generated from an electron microscope, an objective flat-field spectrograph, and a CCD imaging detector. The experimental results showed that the spectrograph employing a new grating overcoated with the B4C layer indicated almost the same spectral resolution and 2.9-4.2 times higher analytical sensitivity compared with those obtained with a previously designed Au-coated grating having a grating constant of 1/1200 mm and used at an incidence of 86.0°.

4.
Rev Sci Instrum ; 92(11): 113102, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34852528

RESUMO

Accurate characterization of incident radiation is a fundamental challenge for diagnostic design. Herein, we present an efficient spectral analysis routine that is able to characterize multiple components within the spectral emission by analytically reducing the number of parameters. The technique is presented alongside the design of a hard x-ray linear absorption spectrometer using the example of multiple Boltzmann-like spectral distributions; however, it is generally applicable to all absorption based spectrometer designs and can be adapted to any incident spectral shape. This routine is demonstrated to be tolerable to experimental noise and suitable for real-time data processing at multi-Hz repetition rates.

5.
Phys Rev Lett ; 124(8): 084802, 2020 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-32167312

RESUMO

Acceleration of particles from the interaction of ultraintense laser pulses up to 5×10^{21} W cm^{-2} with thin foils is investigated experimentally. The electron beam parameters varied with decreasing spot size, not just laser intensity, resulting in reduced temperatures and divergence. In particular, the temperature saturated due to insufficient acceleration length in the tightly focused spot. These dependencies affected the sheath-accelerated protons, which showed poorer spot-size scaling than widely used scaling laws. It is therefore shown that maximizing laser intensity by using very small foci has reducing returns for some applications.

6.
Sci Rep ; 7(1): 17968, 2017 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-29269841

RESUMO

Burst Intensification by Singularity Emitting Radiation (BISER) is proposed. Singularities in multi-stream flows of emitting media cause constructive interference of emitted travelling waves, forming extremely localized sources of bright coherent emission. Here we for the first time demonstrate this extreme localization of BISER by direct observation of nano-scale coherent x-ray sources in a laser plasma. The energy emitted into the spectral range from 60 to 100 eV is up to ~100 nJ, corresponding to ~1010 photons. Simulations reveal that these sources emit trains of attosecond x-ray pulses. Our findings establish a new class of bright laboratory sources of electromagnetic radiation. Furthermore, being applicable to travelling waves of any nature (e.g. electromagnetic, gravitational or acoustic), BISER provides a novel framework for creating new emitters and for interpreting observations in many fields of science.

7.
Rev Sci Instrum ; 88(7): 073304, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28764503

RESUMO

A high repetition rate scintillator-based transverse beam profile diagnostic for laser-plasma accelerated proton beams has been designed and commissioned. The proton beam profiler uses differential filtering to provide coarse energy resolution and a flexible design to allow optimisation for expected beam energy range and trade-off between spatial and energy resolution depending on the application. A plastic scintillator detector, imaged with a standard 12-bit scientific camera, allows data to be taken at a high repetition rate. An algorithm encompassing the scintillator non-linearity is described to estimate the proton spectrum at different spatial locations.

8.
Sci Rep ; 5: 13436, 2015 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-26330230

RESUMO

We report, for the first time, that the energy of femtosecond optical laser pulses, E, with relativistic intensities I > 10(21) W/cm(2) is efficiently converted to X-ray radiation, which is emitted by "hot" electron component in collision-less processes and heats the solid density plasma periphery. As shown by direct high-resolution spectroscopic measurements X-ray radiation from plasma periphery exhibits unusual non-linear growth ~E(4-5) of its power. The non-linear power growth occurs far earlier than the known regime when the radiation reaction dominates particle motion (RDR). Nevertheless, the radiation is shown to dominate the kinetics of the plasma periphery, changing in this regime (now labeled RDKR) the physical picture of the laser plasma interaction. Although in the experiments reported here we demonstrated by observation of KK hollow ions that X-ray intensities in the keV range exceeds ~10(17) W/cm(2), there is no theoretical limit of the radiation power. Therefore, such powerful X-ray sources can produce and probe exotic material states with high densities and multiple inner-shell electron excitations even for higher Z elements. Femtosecond laser-produced plasmas may thus provide unique ultra-bright X-ray sources, for future studies of matter in extreme conditions, material science studies, and radiography of biological systems.

9.
Vopr Virusol ; 60(1): 46-9, 2015.
Artigo em Russo | MEDLINE | ID: mdl-26021075

RESUMO

The goal of this work was to describe methodological approaches to determination of sensitivity and specificity of the enzyme-linked immunosorbent assay kit (ELISA Kit) for detection of the specific anti-Junin virus (JV) antibody. Comparison of ELISA to plaque reduction neutralization test (PRNT) showed direct relationship between antibody titers in the samples of serum of immunized animals, determined by either PRNT or ELISA methods. The obtained results provided an opportunity to form the panels of positive and negative serum samples to determine the sensitivity and specificity of the ELISA Kit. Sensitivity of the ELISA Kit was at least 98% when studying the samples of serum of immunized guinea pigs and rabbits (determined as positive in PRNT). The sensitivity of the ELISA Kit was at least 68% when studying the samples determined by PNRT as uncertain positive. The specificity was 98%. The specificity of the ELISA Kit was 98%.


Assuntos
Anticorpos Antivirais , Febre Hemorrágica Americana , Vírus Junin/imunologia , Kit de Reagentes para Diagnóstico , Animais , Anticorpos Antivirais/sangue , Anticorpos Antivirais/imunologia , Ensaio de Imunoadsorção Enzimática , Cobaias , Febre Hemorrágica Americana/sangue , Febre Hemorrágica Americana/diagnóstico , Febre Hemorrágica Americana/imunologia , Humanos , Coelhos , Sensibilidade e Especificidade
10.
Rev Sci Instrum ; 85(2): 02A705, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24593439

RESUMO

High intensity laser-plasma interaction has attracted considerable interest for a number of years. The laser-plasma interaction is accompanied by generation of various charged particle beams, such as high-energy proton and ions with high charge to mass ratio (Q/M; same as multi-charged ions). Results of simultaneous novel measurements of electron-induced photonuclear neutrons (photoneutron), which are a diagnostic of the laser-plasma interaction, are proposed to use for optimization of the laser-plasma ion generation. The proposed method is demonstrated by the laser irradiation with the intensity of 1 × 10(21) W/cm(2) on the metal foil target. The photoneutrons are measured by using NE213 liquid scintillation detectors. Heavy-ion signal is registered with the CR-39 track detector simultaneously. The measured signals of the electron-induced photoneutrons are well reproduced by using the Particle and Heavy Ion Transport code System. The results obtained provide useful approach for analyzing the various laser based ion beams.

11.
Rev Sci Instrum ; 85(2): 02B904, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24593609

RESUMO

Experimental demonstration of multi-charged heavy ion acceleration from the interaction between the ultra-intense short pulse laser system and the metal target is presented. Al ions are accelerated up to 12 MeV/u (324 MeV total energy). To our knowledge, this is far the highest energy ever reported for the case of acceleration of the heavy ions produced by the <10 J laser energy of 200 TW class Ti:sapphire laser system. Adding to that, thanks to the extraordinary high intensity laser field of ∼10(21) W cm(-2), the accelerated ions are almost fully stripped, having high charge to mass ratio (Q/M).


Assuntos
Alumínio , Íons Pesados , Lasers , Aceleradores de Partículas/instrumentação
12.
Artigo em Russo | MEDLINE | ID: mdl-23805673

RESUMO

AIM: Optimization of conditions of quantitative evaluation of Argentine hemorrhagic fever causative agent. MATERIALS AND METHODS: Junin virus (XJ P37 strain) was obtained from National collection of viral hemorrhagic fever causative agents of the 1st pathogenicity group of the 33rd Central Research Testing Institute. Junin virus (XJ P37 strain) culture with biological activity of 5.2 lg PFUxm(-1) was used in the experiments. Vero B, 6619-1(D) and GMK-AH-1(D) were obtained from collection of cell culture of the Research Scientific Centre of the 33rd Central Research Testing Institute. Calculation of biological activity of Junin virus during titration in cell cultures was carried out by Kerber method with modification by I.P. Ashmarin. RESULTS: During incubation for 4 - 7 days after the infection of cell monolayer the determined biological activity was 4.4 - 6.4 lg PFUxml(-1); the size of the formed negative colonies--(1.5 +/- 0.5) mm. CONCLUSION: The conditions of quantitative evaluation of Argentine hemorrhagic fever were optimized by negative colonies method (using 5 - 7 day Vero B cell culture monolayer with staining of monolayer on day 5 of secondary incubation, recording of results at day 7 after the infection).


Assuntos
Vírus Junin/isolamento & purificação , Ensaio de Placa Viral/métodos , Animais , Chlorocebus aethiops , Febre Hemorrágica Americana/virologia , Vírus Junin/crescimento & desenvolvimento , Células Vero , Replicação Viral
13.
Rev Sci Instrum ; 83(5): 053502, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22667617

RESUMO

X-ray line spectra ranging from 17 to 77 keV were quantitatively measured with a Laue spectrometer, composed of a cylindrically curved crystal and a detector. Either a visible CCD detector coupled with a CsI phosphor screen or an imaging plate can be chosen, depending on the signal intensities and exposure times. The absolute sensitivity of the spectrometer system was calibrated using pre-characterized laser-produced x-ray sources and radioisotopes. The integrated reflectivity for the crystal is in good agreement with predictions by an open code for x-ray diffraction. The energy transfer efficiency from incident laser beams to hot electrons, as the energy transfer agency for specific x-ray line emissions, is derived as a consequence of this work.

14.
Phys Rev Lett ; 108(13): 135004, 2012 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-22540709

RESUMO

We demonstrate a new high-order harmonic generation mechanism reaching the "water window" spectral region in experiments with multiterawatt femtosecond lasers irradiating gas jets. A few hundred harmonic orders are resolved, giving µJ/sr pulses. Harmonics are collectively emitted by an oscillating electron spike formed at the joint of the boundaries of a cavity and bow wave created by a relativistically self-focusing laser in underdense plasma. The spike sharpness and stability are explained by catastrophe theory. The mechanism is corroborated by particle-in-cell simulations.

15.
Opt Express ; 19(5): 4560-5, 2011 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-21369288

RESUMO

Kα line emissions from Mo and Ag plates were experimentally studied using clean, ultrahigh-intensity femtosecond laser pulses. The absolute yields of Kα x-rays at 17 keV from Mo and 22 keV from Ag were measured as a function of the laser pulse contrast ratio and irradiation intensity. Significantly enhanced Kα yields were obtained for both Mo and Ag by employing high contrast ratios and irradiances. Conversion efficiencies of 4.28×10⁻5/sr for Mo and 4.84×10⁻5/sr for Ag, the highest values obtained to date, were demonstrated with contrast ratios in the range 10⁻¹° to 10⁻¹¹.


Assuntos
Lasers , Raios X , Desenho de Equipamento , Análise de Falha de Equipamento , Doses de Radiação
16.
Vopr Virusol ; 55(1): 45-8, 2010.
Artigo em Russo | MEDLINE | ID: mdl-20364672

RESUMO

The time course of changes in the activity of solutions of horseradish peroxidase conjugates with immunoglobulins against Ebola and Marburg fevers was studied in the presence of different components. The series of the conjugates of ELISA kits for the detection of Ebola and Marburg virus antigens, which were prepared on the basis of the designed stabilizing solution, preserved at less than 90% of its baseline activity during 10 months at a storage temperature of 2 to 8 degrees C.


Assuntos
Antígenos Virais/isolamento & purificação , Ebolavirus/isolamento & purificação , Peroxidase do Rábano Silvestre/química , Doença do Vírus de Marburg/diagnóstico , Marburgvirus/isolamento & purificação , Animais , Antígenos Virais/imunologia , Ebolavirus/imunologia , Estabilidade Enzimática , Ensaio de Imunoadsorção Enzimática , Doença pelo Vírus Ebola , Imunoglobulinas/química , Imunoglobulinas/imunologia , Marburgvirus/imunologia
17.
Vopr Virusol ; 54(6): 37-40, 2009.
Artigo em Russo | MEDLINE | ID: mdl-20030281

RESUMO

The efficacy of the antiviral agents nucleoside analogues manufactured in Russia and foreign countries against Bolivian hemorrhagic fever in the treatment and rapid prevention regimens was studied in guinea pigs. In rapid prevention and treatment of guinea pigs, the intraperitoneal injection of 1/10 of the equivalent dose of vero-ribavirin for this animal species was ascertained to protect 70% of the animals infected with Machupo virus strain Carvallo in doses 8 and 10 LD50.


Assuntos
Antivirais/uso terapêutico , Arenavirus do Novo Mundo/efeitos dos fármacos , Febre Hemorrágica Americana/tratamento farmacológico , Ribavirina/uso terapêutico , Administração Oral , Animais , Antivirais/administração & dosagem , Cápsulas , Modelos Animais de Doenças , Feminino , Cobaias , Injeções Intraperitoneais , Masculino , Ribavirina/administração & dosagem , Resultado do Tratamento
18.
Phys Rev Lett ; 103(16): 165002, 2009 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-19905702

RESUMO

An approach for accelerating ions, with the use of a cluster-gas target and an ultrashort pulse laser of 150-mJ energy and 40-fs duration, is presented. Ions with energy 10-20 MeV per nucleon having a small divergence (full angle) of 3.4 degrees are generated in the forward direction, corresponding to approximately tenfold increase in the ion energies compared to previous experiments using solid targets. It is inferred from a particle-in-cell simulation that the high energy ions are generated at the rear side of the target due to the formation of a strong dipole vortex structure in subcritical density plasmas.

19.
Phys Rev Lett ; 103(2): 025002, 2009 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-19659215

RESUMO

An ultrabright high-power x- and gamma-radiation source is proposed. A high-density thin plasma slab, accelerating in the radiation pressure dominant regime by an ultraintense electromagnetic wave, reflects a counterpropagating relativistically strong electromagnetic wave, producing extremely time-compressed and intensified radiation. The reflected light contains relativistic harmonics generated at the plasma slab, all upshifted with the same factor as the fundamental mode of the incident light. The theory of an arbitrarily moving thin plasma slab reflectivity is presented.

20.
Vopr Virusol ; 54(4): 42-4, 2009.
Artigo em Russo | MEDLINE | ID: mdl-19708556

RESUMO

The use of guinea pigs as a laboratory model was proven to be appropriate in investigating the protective properties of a heterological immunoglobulin against Bolivian hemorrhagic fever at the preclinical stage of the study. A highly pathogenic Machupo virus strain that caused guinea pigs' death with respect with an agent's dose was cultivated. Injection of 1.0 ml of the immunoglobulin provided a 100% protective effect for the guinea pigs infected with the highly pathogenic Machupo virus strain in a dose of 10 LD50.


Assuntos
Infecções por Arenaviridae/terapia , Arenavirus do Novo Mundo , Imunoglobulinas/administração & dosagem , Imunoglobulinas/imunologia , Animais , Modelos Animais de Doenças , Relação Dose-Resposta Imunológica , Avaliação Pré-Clínica de Medicamentos , Cobaias , Injeções Intramusculares
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...