Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 13(11): e0207342, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30408127

RESUMO

We investigated the performance of the handheld radial shape discrimination (hRSD) test in detecting the development of neovascular AMD (nAMD) in a prospective, longitudinal, observational study. Patients diagnosed with unilateral nAMD, with no nAMD in the other eye (the study eye, SE), completed the hRSD test on consecutive, routine clinic visits up to a maximum of 12, or until they were diagnosed with nAMD in the SE based on slit-lamp biomicroscopy and spectral-domain OCT assessment, with fluorescein angiography confirmation. Masked grading was carried out to confirm the diagnosis of nAMD, and to ensure no cases of nAMD were missed. Receiver operating characteristics (ROC) analysis was used to explore the diagnostic performance of the hRSD test relative to clinical diagnosis. Data were available from 179 patients of whom 19 (10.6%; "converters") developed nAMD in the SE. The mean hRSD threshold at conversion was -0.47 (95% CI -0.38 to -0.55) logMAR compared to -0.53 (-0.50 to -0.57) logMAR in 160 non-converters. hRSD threshold in the converters began to decline 190 days before diagnosis of nAMD. The ROC curve demonstrated that at an hRSD cut-off of -0.60 logMAR, sensitivity was 0.79 (0.54-0.94) with a specificity of 0.54 (0.46-0.62); positive and negative predictive values were 0.16 and 0.96 respectively. We conclude that the hRSD test has moderate sensitivity for detecting the earliest stages of nAMD in the at-risk fellow eyes of patients with unilateral nAMD, compared to clinical diagnosis. Given its relative inexpensiveness, ease of use and the inherent connectivity of the platforms it can be presented on, it may have a role in early detection of nAMD in the population at large.


Assuntos
Olho , Degeneração Macular , Neovascularização Retiniana , Idoso , Idoso de 80 Anos ou mais , Olho/patologia , Olho/fisiopatologia , Feminino , Humanos , Estudos Longitudinais , Degeneração Macular/diagnóstico , Degeneração Macular/patologia , Degeneração Macular/fisiopatologia , Masculino , Pessoa de Meia-Idade , Neovascularização Retiniana/diagnóstico , Neovascularização Retiniana/patologia , Neovascularização Retiniana/fisiopatologia , Fatores de Risco
2.
PeerJ ; 4: e2650, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27833815

RESUMO

BACKGROUND: Central vision, critical for everyday tasks such as reading and driving, is impacted by age-related changes in the eye and by diseases such as age-related macular degeneration. The detection of changes in macular function is therefore important. The Radial Shape Discrimination (RSD) test measures the threshold at which distortions in a radial frequency pattern can be detected and there is evidence that it is more sensitive to macular pathology than visual acuity (VA). It also provides a more quantitative measure of macular function than the commonly available Amsler grid. Recently, handheld versions of the test (hRSD) in which stimuli are presented on mobile devices (e.g., Apple iPod Touch, iPhone) have been developed. We investigated the characteristics of the hRSD test in healthy participants. METHODS: Data were collected using both three-alternative forced choice (3AFC) and 4AFC versions of the hRSD test, presented on an Apple iPod Touch. For the 3AFC version, data from a single test session were available for 186 (72 male; mean ± SD age 42 ± 17y; range 16-90y) healthy participants. Test-retest data were available for subgroups of participants (intra-session: N = 74; tests approximately 2 months apart: N = 30; tests 39 months apart: N = 15). The 3AFC and 4AFC versions were directly compared in 106 participants who also completed a usability questionnaire. Distance and near VA and Pelli Robson Contrast Sensitivity (CS) data were collected and undilated fundoscopy performed on the majority of participants. RESULTS: Mean (±SD) 3AFC hRSD threshold was -0.77 ± 0.14 logMAR, and was statistically significantly correlated with age (Pearson r = 0.35; p < 0.001). The linear regression of hRSD threshold on age had a slope of +0.0026 compared to +0.0051 for near VA (which also correlated with age: r = 0.51; p < 0.001). There were no statistically significant differences in hRSD thresholds for any of the test-retest subgroups. We also observed no statistically significant difference between 3AFC (-0.82 ± 0.11 logMAR) and 4AFC (-0.80 ± 0.12 logMAR) hRSD thresholds (t = 1.85, p = 0.067) and participants reported excellent test usability with no strong preference expressed between the 3AFC and 4AFC versions of the test. DISCUSSION: The 3AFC hRSD thresholds we report are consistent with a number of previous studies, as is its greater stability in ageing compared to VA. We have also shown that in the absence of pathology, thresholds are stable over short and long timescales. The 4AFC thresholds we have reported provide a baseline for future investigations, and we have confirmed that 3AFC and 4AFC thresholds are similar, providing a basis of comparisons between studies using the different versions. As the hRSD test is easy to use and relatively inexpensive, clinical studies are now required to establish its ability to detect and monitor macular pathologies.

3.
Br Ir Orthopt J ; 12: 9-15, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-27738450

RESUMO

AIMS: With the arrival of effective treatments for neovascular age-related macular degeneration (nvAMD) there is a need to find improved tests that would allow early detection. Ideally, these tests would allow monitoring of vision by patients themselves from home. The aim of this review is to discuss the available evidence for two recently developed vision tests designed for this purpose: the Preferential Hyperacuity Perimeter (PHP) test and the Radial Shape Discrimination (RSD) test. METHODS: Articles that investigated detection of nvAMD were reviewed. The methodology of the clinical evidence, where available, was judged for bias and applicability of the results to the general population using the QUADAS-2 quality assessment tool. RESULTS: The PHP test has proved to be good at detecting nvAMD but many studies assessed in this review were biased in the selection of patients, restricting the results to only those patients who can use the test and produce reliable results. On the other hand the RSD test is a simple test, well accepted by elderly patients with AMD. However, clinical studies to determine its value in the detection of early signs of nvAMD are still required. CONCLUSIONS: To date, more studies have investigated the utility of the PHP test compared with the RSD test for detection of nvAMD. Both tests show promise but further evidence is needed to determine the real generalisability of the PHP test and the sensitivity of the RSD test.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...