Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
2.
Microvasc Res ; 148: 104545, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37146675

RESUMO

BACKGROUND: nailfold capillaroscopy (NCF) is a non-invasive imaging technique to seek peripheral microcirculation abnormalities in children and adults. Familial hypercholesterolemia is a genetic disorder caused by mutations capable of increasing blood levels of low-density lipoproteins cholesterol (LDL-C), thus triggering early atherosclerosis. The study aims at evaluating peripheral microcirculation in children with heterozygous familial hypercholesterolemia (HeFH) by means of NFC in comparison with healthy peers and at searching for possible correlations between these abnormalities and patients' lipid panel. METHODS: thirty-six HeFH patients were enrolled (13 males and 23 females. Mean age 8 ± 3 years; age range 3-13 years). They had increased levels of total cholesterol (237.9 ± 34.2 mg/dl) and LDL-C (154.2 ± 37.6 mg/dl). Both values were ≥95th gender and age specific centile. All the subjects in the study underwent NFC. RESULTS: In 69.4 % of HeFH children nailfold capillaries were tortuous (p < 0.00001 compared to healthy controls). In 41.6 % the number of capillaries was markedly reduced (<7 capillaries/mm). The mean number of capillaries was 8.4 ± 2.6/mm in HeFH and 12.2 ± 1.4/mm in healthy controls (p < 0.00001). In 100 % of the sample size capillary blood flow was slowed down (p < 0.00001). In 50 % of the sample size a blood "sludge" phenomenon was seen (p < 0.00001). No gender differences were detected. Sludge phenomenon was seen only in those with LDL-C over 99th centile (p < 0.00001). CONCLUSION: NCF allows the identification of an early peripheral microvascular dysfunction in HeFH children which is similar to that already seen in atherosclerotic disease. Prompt identification of these capillary abnormalities may be crucial in implementing early prevention measures.


Assuntos
Capilares , Erros Inatos do Metabolismo Lipídico , Angioscopia Microscópica , Humanos , Masculino , Feminino , Pré-Escolar , Criança , Adolescente , Capilares/diagnóstico por imagem , Capilares/patologia , Angioscopia Microscópica/métodos , Microcirculação , Erros Inatos do Metabolismo Lipídico/diagnóstico por imagem , Erros Inatos do Metabolismo Lipídico/patologia
3.
Cardiology ; 144(3-4): 101-111, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31614346

RESUMO

BACKGROUND: The purpose of the study was to assess biventricular parameters of wall deformation with three-dimensional speckle tracking echocardiography (3DSTE) in adolescents and young adults with human immunodeficiency virus (HIV) infection on antiretroviral therapy in order to detect a possible subclinical myocardial dysfunction. METHODS: Twenty-one patients aged 12-39 years with HIV, 21 normal controls of the same age and sex, and 21 patients with idiopathic nonischemic dilated cardiomyopathy (DCM) were studied with 3DSTE. All HIV patients were stable in terms of HIV infection, with no history of heart disease or other chronic systemic disease except HIV infection, and were on highly active antiretroviral therapy with good immunological control. Standard echocardiographic measures of left ventricular (LV)-right ventricular (RV) function were assessed. 3D LV global longitudinal strain (GLS), circumferential strain, radial strain, and LV twist were calculated. Global area strain (GAS) was calculated by 3DSTE as percentage variation in surface area defined by the longitudinal and circumferential strain vectors. 3D RV global and free-wall longitudinal strain (FWLS) were obtained. RESULTS: LV GLS and GAS were lower in HIV patients compared to normal controls (p = 0.002, and p = 0.01, respectively). There were no significant differences in LV ejection fractions between the groups. There was a weak positive correlation between LV GLS and age (r = 0.215, p = 0.034) and a weak negative correlation between LV GLS and nadir-CD4 T-cells count (r = 0.198, p = 0.043). DCM patients had more marked and widespread reduction in LV GLS and GAS compared to controls (p < 0.001), whereas in HIV patients LV strain impairment (p < 0.05) was more localized in basal and apical regions. RV FWLS was significantly reduced in HIV patients when compared with the control group (p = 0.03). No patient had pulmonary systolic pressure higher than 35 mm Hg. CONCLUSIONS: 3DSTE may help to identify HIV patients at high cardiovascular risk allowing early detection of biventricular dysfunction in the presence of normal LV ejection fraction and in the absence of pulmonary hypertension. LV strain impairment in HIV patients is less prominent and widespread compared to DCM patients.


Assuntos
Ecocardiografia/métodos , Infecções por HIV/fisiopatologia , Imageamento Tridimensional , Função Ventricular Esquerda , Função Ventricular Direita , Adolescente , Adulto , Cardiomiopatia Dilatada/fisiopatologia , Estudos de Casos e Controles , Criança , Feminino , Humanos , Masculino , Projetos Piloto , Adulto Jovem
5.
Ultrasound Med Biol ; 44(6): 1198-1211, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29609808

RESUMO

Our aim was to analyze atrial function with 2-D (2-D-STE) and 3-D (3-D-STE) speckle tracking echocardiography in patients with atrial septal devices and paroxysmal atrial fibrillation (PAF). One hundred sixteen patients and a subgroup of 22 patients who developed PAF after device insertion were studied. Left atrial and right atrial peak longitudinal strain and standard deviations of time to peak strain (TPS) were calculated using 2-D-STE. The left atrial/right atrial emptying fraction and expansion index were determined using 3-D-STE. By multivariate analysis, pre-closure 3-D right atrial expansion index, left atrial time to peak strain, and 3-D left atrial expansion index were independently associated with PAF. Compared with the other indices, receiver operating characteristic analysis revealed better diagnostic accuracy for the combination of pre-closure time to peak strain and 3-D expansion index in detecting PAF. Patients with atrial septal devices have pre-existing left and right atrial dilation and dysfunction as assessed by 2-D-STE and 3-D-STE that appear sensitive for the stratification of PAF risk in this population.


Assuntos
Fibrilação Atrial/fisiopatologia , Função Atrial , Septo Interatrial/cirurgia , Ecocardiografia/métodos , Cardiopatias Congênitas/cirurgia , Adulto , Ecocardiografia Tridimensional/métodos , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes
6.
J Am Soc Echocardiogr ; 28(9): 1070-82, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25982249

RESUMO

BACKGROUND: The goal of this study was to determine changes in left ventricular (LV) and right ventricular (RV) function with three-dimensional (3D) speckle-tracking echocardiography (STE) after percutaneous mitral valve repair with the MitraClip system in high-risk surgical patients with moderate to severe or severe secondary mitral regurgitation (MR). METHODS: Thirty-two patients with MR undergoing MitraClip were prospectively included. Patients underwent two-dimensional (2D) and 3D transthoracic echocardiography before clip implantation and after 6-month follow-up. LV and RV longitudinal strain was obtained by 2D STE and 3D STE. LV circumferential, radial, and area strain was calculated by 3D STE. Data analysis was performed offline. RESULTS: At 6-month follow-up, significant improvements were seen in LV 2D global longitudinal strain (P < .005), 3D global longitudinal strain (P = .0002), and 3D area strain (P = .0001). Overall, significant improvements were also seen in 3D RV ejection fraction (P < .05) and 3D RV free-wall longitudinal strain (P < .05). A poor increase in LV strain after clip implantation (P = NS) occurred in patients with pronounced preexisting RV dysfunction. The areas under the receiver operating characteristic curves for LV and RV 3D speckle-tracking echocardiographic parameters showed high discriminative values (range, 0.87-0.91) in predicting unfavorable outcomes with persistent symptoms (New York Heart Association class > II) after the procedure. CONCLUSIONS: Three-dimensional STE showed overall LV and RV strain improvement after clip implantation as well as lower postprocedural LV strain values in patients with worse preexisting RV function. These findings could help in guiding MR treatment strategies, suggesting different therapies in the presence of marked RV impairment or anticipating the procedure in case of evolving RV dysfunction.


Assuntos
Ecocardiografia Tridimensional/métodos , Implante de Prótese de Valva Cardíaca/instrumentação , Ventrículos do Coração/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico por imagem , Função Ventricular Esquerda/fisiologia , Função Ventricular Direita/fisiologia , Idoso , Desenho de Equipamento , Feminino , Seguimentos , Ventrículos do Coração/fisiopatologia , Humanos , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Período Pós-Operatório , Prognóstico , Desenho de Prótese , Curva ROC , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Fatores de Tempo
7.
Eur Heart J Cardiovasc Imaging ; 15(12): 1377-85, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25139906

RESUMO

AIMS: Percutaneous closure of patent foramen ovale (PFO) in cryptogenic cerebrovascular events is an alternative to medical therapy. The interpretation of residual shunts after implantation of different devices for PFO with different morphologies is controversial. METHODS AND RESULTS: Transcatheter PFO closure was performed in 123 patients with a history of ≥1 paradoxical embolism using three different devices: Amplatzer (n = 46), Figulla Occlutech (n = 41), and Atriasept Cardia (n = 36). Fifty-six patients presented with simple PFO and 67 patients had complex morphologies. All patients were studied with contrast enhanced transesophageal echocardiography (TEE) before interventional procedure and thereafter at 1 and 6 months and every 6-12 months in case of incomplete closure. Definite closure was confirmed in at least two consecutive TEE studies. Various PFO morphologies were identified by TEE before device implantation. The device size to PFO diameter ratio was significantly increased in patients with complex PFO compared with those patients with a simple PFO morphology (P < 0.05). The difference between the closure rate of S-PFO and C-PFO concerning each device type was significant (Amplatzer P = 0.0027, Figulla P = 0.0043, and Atriasept P < 0.01). The mean follow-up period was 3.4 years (median 2.7 years) with a cerebrovascular re-event rate of 2.4% per year. In three patients, thrombi were detected in the 6-month TEE controls and resolved after medical therapy. In three other patients, the implantation of an adjunctive device was necessary for residual shunt. CONCLUSION: In our series of patients, the closure rate was dependent on PFO morphology more than occluder size and type. An adjunctive device was implanted in selected cases.


Assuntos
Cateterismo Cardíaco , Ecocardiografia Transesofagiana/métodos , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/terapia , Implante de Prótese de Valva Cardíaca , Ultrassonografia de Intervenção , Adulto , Idoso , Meios de Contraste , Feminino , Seguimentos , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade , Fatores de Tempo , Resultado do Tratamento
8.
Eur Heart J Cardiovasc Imaging ; 14(10): 1010-20, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23299399

RESUMO

AIMS: Previous studies have shown distinct models of cardiac adaptations to the training in master athletes and different effects of endurance and strength-training on cardiovascular function. We attempted to assess left-ventricular (LV) function, aortic (Ao) function, and right-ventricular (RV) function in athletes with different forms of training by using three-dimensional (3D) echocardiography, tissue Doppler imaging (TDI) and speckle-tracking imaging (STI). METHODS AND RESULTS: We examined 35 male marathon runners (endurance-trained athletes, ETA), 35 powerlifting athletes (strength-trained athletes, STA), 35 martial arts athletes (mixed-trained athletes, MTA), and 35 sedentary untrained healthy men (controls, CTR). Two-dimensional and three-dimensional echocardiography were performed for the assessment of LV and RV systolic/diastolic function. LV and RV longitudinal strain (LS) and LV torsion (LVtor) were determined using STI (EchoPAC BT11, GE-Ultrasound). Maximum velocity of systolic wall expansion peaks (AoSvel) was determined using TDI. ETA experienced LV eccentric hypertrophy with increased 3D LV end-diastolic volume and mass and significant increase in peak systolic apical rotation and LVtor. In all groups of athletes, RV-LS was reduced at rest and improved after exercise. AoSvel was significantly increased in ETA and MTA and significantly decreased in STA compared with CTR. There were good correlations between LV remodelling and aortic stiffness values. Multivariate analysis showed aortic wall velocities to be independently related to LV mass index. CONCLUSION: In strength-trained, endurance-trained, and mixed-trained athletes, ventricular and vascular response assessed by 3DE, TDI, and STI underlies different adaptations of LV, RV, and aortic indexes.


Assuntos
Aorta/fisiologia , Ecocardiografia Tridimensional/métodos , Interpretação de Imagem Assistida por Computador/métodos , Esportes/fisiologia , Função Ventricular Esquerda/fisiologia , Função Ventricular Direita/fisiologia , Adaptação Fisiológica , Adolescente , Adulto , Antropometria , Atletas/estatística & dados numéricos , Estudos de Casos e Controles , Ecocardiografia Doppler de Pulso/métodos , Ergometria/métodos , Humanos , Masculino , Artes Marciais/fisiologia , Análise Multivariada , Contração Miocárdica/fisiologia , Resistência Física , Valores de Referência , Corrida/fisiologia , Volume Sistólico/fisiologia , Rigidez Vascular/fisiologia , Levantamento de Peso/fisiologia , Adulto Jovem
9.
Ann Ital Chir ; 82(3): 179-84, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21780558

RESUMO

AIM OF THE STUDY: The aim of the study was to considerate the effective usefulness of preoperative stress test and echocardiography in adult patients with coronary artery disease, undergoing non-cardiac surgery. MATERIALS AND METHODS: In the last three years, 200 patients aged 58-85, affected by stable ischemic pathology, undergoing non cardiac surgery, and treated with oral drugs, were enrolled for an assessment orotocol including anamnesis, objective examination, blood pressure, RCG, blood chemistry analysis, and was performed a cardiac risk evaluation. A second 50 patients control cohort of the same class was subjected to the same tests, and preoperative and exercise stress test. RESULTS: All patients showed a good hemodynamic compensation and a quick recovery, and the group of 200 patients for whom the risk was closed without further investigation has concluded the process on average three days before the group underwent echocardiography and exercise stress test. DISCUSSION: The clinical evaluation of cardiac patients waiting for non-cardiac surgery, performed through anamnesis, examinations and the ECGs, is the cornerstone of cardiac risk stratification. It also important the type of surgery, as well as some priority conditions like certain neoplastic: diseases, where it seems appropriate to speed up the diagnostic program. CONCLUSIONS: When patients are hemodynamically stable and their conditions controlled by appropriate therapy, it is sufficient to perform first-level tests for the preoperative stratification of cardiovascular risk. It's recommended to perform echocardiogram and stress test when the first level tests are abnormal, when there is a worsening of the conditions prior to admission, or when the patient is not hemodynamically stable.


Assuntos
Teste de Esforço , Cardiopatias/diagnóstico , Cuidados Pré-Operatórios , Procedimentos Cirúrgicos Operatórios , Idoso , Idoso de 80 Anos ou mais , Cardiopatias/diagnóstico por imagem , Humanos , Pessoa de Meia-Idade , Ultrassonografia
10.
Angiology ; 54(2): 219-27, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12678198

RESUMO

The ability of trimetazidine (2,3,4, trimethoxybenzylpiperazine dihydrochloride, TMZ) to protect the myocardium against anthracycline (ANT)-induced cardiotoxicity during chemotherapy has been evaluated in female patients with breast cancer. A clinical trial was conducted in 61 patients subdivided into three groups: group 1 (n = 15, G1 ) treated with standard ANT protocol and cardioprotection by dexrazoxane (DEX) plus TMZ (60 mg, daily dose); group 2 (n = 22, G2) treated with ANT and cardioprotection by TMZ only; and group 3 (n = 24, G3) scheduled to receive ANT therapy and DEX. All the patients submitted to an echocardiographic evaluation of diastolic function (E wave velocity, A wave velocity, isovolumetric relaxation time [IVRT], deceleration time [DT]) at enrollment (T0), at T1 time, at T2 time, and at T3 time. After a 12-month follow-up period, the patients showed a good conservation of diastolic function both in G1 and G2 groups. No statistically significant difference was observed in E wave and A wave velocity and E/A ratio after ANT treatment. TMZ produced a cardioprotective effect, comparable to DEX protection, against subacute and chronic subclinical cardiotoxicity with no significant changes in diastolic function after 1 year of follow-up.


Assuntos
Antibióticos Antineoplásicos/efeitos adversos , Antineoplásicos/efeitos adversos , Neoplasias da Mama/tratamento farmacológico , Coração/efeitos dos fármacos , Trimetazidina/uso terapêutico , Vasodilatadores/uso terapêutico , Idoso , Antibióticos Antineoplásicos/uso terapêutico , Antineoplásicos/uso terapêutico , Fármacos Cardiovasculares/uso terapêutico , Diástole/efeitos dos fármacos , Feminino , Humanos , Pessoa de Meia-Idade , Razoxano/uso terapêutico , Trimetazidina/farmacologia , Vasodilatadores/farmacologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...