Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
Eur J Nucl Med Mol Imaging ; 39(2): 316-25, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22124778

RESUMO

PURPOSE: State-of-the-art positron emission tomography/computed tomography (PET/CT) systems incorporate multislice CT technology, thus facilitating the acquisition of multiphase, contrast-enhanced CT data as part of integrated PET/CT imaging protocols. We assess the influence of a highly concentrated iodinated contrast medium (CM) on quantification and image quality following CT-based attenuation correction (CT-AC) in PET/CT. METHODS: Twenty-eight patients with suspected malignant liver lesions were enrolled prospectively. PET/CT was performed 60 min after injection of 400 MBq of (18)F-fluorodeoxyglucose (FDG) and following the biphasic administration of an intravenous CM (400 mg iodine/ml, Iomeron 400). PET images were reconstructed with CT-AC using any of four acquired CT image sets: non-enhanced, pre-contrast (n-PET), arterial phase (art-PET), portal venous phase (pv-PET) and late phase (late-PET). Normal tissue activity and liver lesions were assessed visually and quantitatively on each PET/CT image set. RESULTS: Visual assessment of PET following CT-AC revealed no noticeable difference in image appearance or quality when using any of the four CT data sets for CT-AC. A total of 44 PET-positive liver lesions was identified in 21 of 28 patients. There were no false-negative or false-positive lesions on PET. Mean standardized uptake values (SUV) in 36 evaluable lesions were: 5.5 (n-PET), 5.8 (art-PET), 5.8 (pv-PET) and 5.8 (late-PET), with the highest mean increase in mean SUV of 6%. Mean SUV changes in liver background increased by up to 10% from n-PET to pv-PET. CONCLUSION: Multiphase CT data acquired with the use of highly concentrated CM can be used for qualitative assessment of liver lesions in torso FDG PET/CT. The influence on quantification of FDG uptake is small and negligible for most clinical applications.


Assuntos
Meios de Contraste/farmacologia , Fluordesoxiglucose F18/farmacologia , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Diagnóstico por Imagem/métodos , Reações Falso-Positivas , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade
2.
Strahlenther Onkol ; 187(7): 426-32, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21713396

RESUMO

BACKGROUND AND PURPOSE: To investigate prostate movement during deep breathing and contraction of abdominal musculature by means of dynamic MRI and analyze implications for image-guided radiotherapy of prostate cancer. PATIENTS AND METHODS: A total of 43 patients and 8 healthy volunteers were examined with MRI. Images during deep respiration and during contraction of abdominal musculature (via a coughing maneuver) were obtained with dynamic two-dimensional (2D) balanced SSFP; 3 frames/s were obtained over an acquisition time of 15 s. Images were acquired in sagittal orientation to evaluate motion along both the craniocaudal (cc)-axis and anteroposterior (ap)-axis. Prostate motion was quantified semi-automatically using dedicated software tools. RESULTS: Respiratory induced mean cc-axis displacement of the prostate was 2.7 ± 1.9 (SD) mm (range, 0.5-10.6 mm) and mean ap-axis displacement 1.8 ± 1.0 (SD) mm (range, 0.3-10 mm). In 69% of the subjects, breathing-related prostate movements were found to be negligible (< 3 mm). The prostate displacement for abdominal contraction was significantly higher: mean cc-axis displacement was max. 8.4 ± 6.7 (SD) mm (range, 0.6-27 mm); mean anteroposterior movement was 8.3 ± 7.7 (SD) mm (range, 0.7-26 mm). CONCLUSION: Dynamic MRI is an excellent tool for noninvasive real-time imaging of prostate movement. Further investigations regarding possible applications in image-guided radiotherapy, e.g., for individualized planning and in integrated linac/MRI systems, are warranted.


Assuntos
Adenocarcinoma/radioterapia , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Próstata/efeitos da radiação , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Assistida por Computador/métodos , Técnicas de Imagem de Sincronização Respiratória/métodos , Músculos Abdominais/fisiopatologia , Adenocarcinoma/patologia , Adenocarcinoma/fisiopatologia , Adulto , Idoso , Humanos , Aumento da Imagem , Masculino , Pessoa de Meia-Idade , Movimento , Contração Muscular/fisiologia , Estadiamento de Neoplasias , Próstata/patologia , Próstata/fisiopatologia , Neoplasias da Próstata/patologia , Neoplasias da Próstata/fisiopatologia , Sensibilidade e Especificidade
3.
Strahlenther Onkol ; 187(4): 252-9, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21437769

RESUMO

BACKGROUND: Hypoxia inducible factor-1 has been identified as a potential target to overcome hypoxia-induced radioresistance The aim of the present study was to investigate whether selective HIF-1 inhibition via small interfering RNA (siRNA) targeting hypoxia-inducible factor 1α (HIF-1α) affects hypoxia-induced radioresistance in HT 1080 human fibrosarcoma cells. MATERIAL AND METHODS: HIF-1α expression in HT 1080 human fibrosarcoma cells in vitro was silenced using HIF-1α siRNA sequence primers. Quantitative real-time polymerase chain reaction assay was performed to quantify the mRNA expression of HIF-1α. HIF-1α protein levels were studied by Western blotting at 20% (air) or after 12 hours at 0.1% O2 (hypoxia). Cells were assayed for clonogenic survival after irradiation with 2, 5, or 10 Gy, under normoxic or hypoxic conditions in the presence of HIF-1α-targeted or control siRNA sequences. A modified oxygen enhancement ratio (OER´) was calculated as the ratio of the doses to achieve the same survival at 0.1% O(2) as at ambient oxygen tensions. OER´ was obtained at cell survival levels of 50%, 37%, and 10%. RESULTS: HIF-1α-targeted siRNA enhanced radiation treatment efficacy under severely hypoxic conditions compared to tumor cells treated with scrambled control siRNA. OER was reduced on all survival levels after treatment with HIF-1α-targeted siRNA, suggesting that inhibition of HIF-1 activation by using HIF-1α-targeted siRNA increases radiosensitivity of hypoxic tumor cells in vitro. CONCLUSION: Inhibition of HIF-1 activation by using HIF-1α-targeted siRNA clearly acts synergistically with radiotherapy and increase radiosensitivity of hypoxic cells in vitro.


Assuntos
Hipóxia Celular/genética , Sobrevivência Celular/genética , Sobrevivência Celular/efeitos da radiação , Fibrossarcoma/patologia , Inativação Gênica , Subunidade alfa do Fator 1 Induzível por Hipóxia/genética , Tolerância a Radiação/genética , Transcrição Gênica/genética , Células Tumorais Cultivadas/efeitos da radiação , Linhagem Celular Tumoral , Relação Dose-Resposta à Radiação , Humanos , RNA Mensageiro/genética , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Ensaio Tumoral de Célula-Tronco
4.
Int J Radiat Oncol Biol Phys ; 77(5): 1369-74, 2010 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-19932943

RESUMO

PURPOSE: Normal tissue changes (NTC) of the normal lung parenchyma are commonly seen after stereotactic single-dose radiotherapy (radiosurgery) of lung tumors. The aim of this study was to investigate the extent and dynamics of NTCs after radiosurgery. METHODS AND MATERIALS: Fifty lung tumors in 49 patients were treated with radiosurgery. Follow-up CTs were anatomically matched to the treatment planning CTs, incorporating the treatment plan and enabling spatial correlation of initial radiation dose distribution and subsequent NTCs of the lung. Lung parenchyma was divided into nine areas of different radiation dose exposures (range, 6-35 Gy). Areas were investigated and compared at different time points according to the development of NTCs. RESULTS: Twenty-six patients developed NTCs during follow-up. The evaluation of the dependency of the extent of NTCs on the amount of radiation dose lead to a linear model for the fixed effects: Fraction of reacting volume =Intercept(T) +0.0208 * Dose ("Dose" should be given in Gy). Dose had a slope of 0.0208 (fraction of normal tissue reaction/Gy) (SE 0.000804, p < 0.0001), implying a significant correlation between dose level and the extent of NTC. CONCLUSION: For radiosurgery of lung tumors, a significant correlation of radiation dose and the extent of NTCs could be demonstrated. Using the introduced formula, a preview on the extent of NTCs to develop in normal lung parenchyma according to the dose level can be performed.


Assuntos
Neoplasias Pulmonares/cirurgia , Pulmão/efeitos da radiação , Lesões por Radiação/patologia , Radiocirurgia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Fibrose Pulmonar/diagnóstico por imagem , Fibrose Pulmonar/etiologia , Lesões por Radiação/diagnóstico por imagem , Radiografia , Radiocirurgia/efeitos adversos , Dosagem Radioterapêutica , Fatores de Tempo
5.
Korean J Radiol ; 10(6): 559-67, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19885311

RESUMO

OBJECTIVE: To estimate a new technique for quantifying regional lung motion using 3D-MRI in healthy volunteers and to apply the technique in patients with intra- or extrapulmonary tumors. MATERIALS AND METHODS: Intraparenchymal lung motion during a whole breathing cycle was quantified in 30 healthy volunteers using 3D-dynamic MRI (FLASH [fast low angle shot] 3D, TRICKS [time-resolved interpolated contrast kinetics]). Qualitative and quantitative vector color maps and cumulative histograms were performed using an introduced semiautomatic algorithm. An analysis of lung motion was performed and correlated with an established 2D-MRI technique for verification. As a proof of concept, the technique was applied in five patients with non-small cell lung cancer (NSCLC) and 5 patients with malignant pleural mesothelioma (MPM). RESULTS: The correlation between intraparenchymal lung motion of the basal lung parts and the 2D-MRI technique was significant (r = 0.89, p < 0.05). Also, the vector color maps quantitatively illustrated regional lung motion in all healthy volunteers. No differences were observed between both hemithoraces, which was verified by cumulative histograms. The patients with NSCLC showed a local lack of lung motion in the area of the tumor. In the patients with MPM, there was global diminished motion of the tumor bearing hemithorax, which improved significantly after chemotherapy (CHT) (assessed by the 2D- and 3D-techniques) (p < 0.01). Using global spirometry, an improvement could also be shown (vital capacity 2.9 +/- 0.5 versus 3.4 L +/- 0.6, FEV1 0.9 +/- 0.2 versus 1.4 +/- 0.2 L) after CHT, but this improvement was not significant. CONCLUSION: A 3D-dynamic MRI is able to quantify intraparenchymal lung motion. Local and global parenchymal pathologies can be precisely located and might be a new tool used to quantify even slight changes in lung motion (e.g. in therapy monitoring, follow-up studies or even benign lung diseases).


Assuntos
Carcinoma Pulmonar de Células não Pequenas/fisiopatologia , Imageamento Tridimensional , Neoplasias Pulmonares/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Mesotelioma/fisiopatologia , Movimento/fisiologia , Estudos de Casos e Controles , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade
6.
Int J Radiat Oncol Biol Phys ; 73(3): 919-26, 2009 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-19215826

RESUMO

PURPOSE: Four-dimensional (4D) imaging is a key to motion-adapted radiotherapy of lung tumors. We evaluated in a ventilated ex vivo system how size and displacement of artificial pulmonary nodules are reproduced with helical 4D-CT, 4D-MRI, and linac-integrated cone beam CT (CBCT). METHODS AND MATERIALS: Four porcine lungs with 18 agarose nodules (mean diameters 1.3-1.9 cm), were ventilated inside a chest phantom at 8/min and subject to 4D-CT (collimation 24 x 1.2 mm, pitch 0.1, slice/increment 24 x 10(2)/1.5/0.8 mm, pitch 0.1, temporal resolution 0.5 s), 4D-MRI (echo-shared dynamic three-dimensional-flash; repetition/echo time 2.13/0.72 ms, voxel size 2.7 x 2.7 x 4.0 mm, temporal resolution 1.4 s) and linac-integrated 4D-CBCT (720 projections, 3-min rotation, temporal resolution approximately 1 s). Static CT without respiration served as control. Three observers recorded lesion size (RECIST-diameters x/y/z) and axial displacement. Interobserver- and interphase-variation coefficients (IO/IP VC) of measurements indicated reproducibility. RESULTS: Mean x/y/z lesion diameters in cm were equal on static and dynamic CT (1.88/1.87; 1.30/1.39; 1.71/1.73; p > 0.05), but appeared larger on MRI and CBCT (2.06/1.95 [p < 0.05 vs. CT]; 1.47/1.28 [MRI vs. CT/CBCT p < 0.05]; 1.86/1.83 [CT vs. CBCT p < 0.05]). Interobserver-VC for lesion sizes were 2.54-4.47% (CT), 2.29-4.48% (4D-CT); 5.44-6.22% (MRI) and 4.86-6.97% (CBCT). Interphase-VC for lesion sizes ranged from 2.28% (4D-CT) to 10.0% (CBCT). Mean displacement in cm decreased from static CT (1.65) to 4D-CT (1.40), CBCT (1.23) and MRI (1.16). CONCLUSIONS: Lesion sizes are exactly reproduced with 4D-CT but overestimated on 4D-MRI and CBCT with a larger variability due to limited temporal and spatial resolution. All 4D-modalities underestimate lesion displacement.


Assuntos
Neoplasias Pulmonares , Pulmão , Movimento , Nódulos Pulmonares Múltiplos , Respiração , Animais , Tomografia Computadorizada de Feixe Cônico/métodos , Desenho de Equipamento , Pulmão/diagnóstico por imagem , Pulmão/patologia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Imageamento por Ressonância Magnética/métodos , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/patologia , Variações Dependentes do Observador , Aceleradores de Partículas , Imagens de Fantasmas , Reprodutibilidade dos Testes , Suínos , Tomografia Computadorizada Espiral/métodos
7.
Invest Radiol ; 43(10): 737-44, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18791416

RESUMO

OBJECTIVE: To evaluate and compare the role of computed tomography (CT), positron emission tomography (PET), PET/CT, and magnetic resonance imaging (MRI) in the correct staging of patients with limited malignant pleural mesothelioma (MPM). MATERIALS AND METHODS: Fifty-four patients with an epithelial MPM (34 men and 20 women) were included in this study. Patients were referred to our department for staging in a predicted resectable state (stage II/III). Within 3 days, PET/CT and MRI was performed in all patients. Images were evaluated by 3 specialists in the field of PET/CT and MRI. The subexaminations of PET/CT, PET, and CT were independently evaluated with respect to tumor stage. Subexaminations were compared with each other, with MRI and PET/CT. N-stage was verified by mediastinoscopy. Afterward, consensus reading was performed.In 52 patients, surgery served as gold standard. In 2 patients, follow-up control served as gold standard as an inoperable situation with distant metastases was found. Additionally, interobserver variability (kappa value) was calculated. RESULTS: In stage II, accuracy was 0.77 (CT), 0.86 (PET), 0.8 (MRI), 1.0 (PET/CT), and in stage III 0.75, 0.83, 0.9, 1.0. PET/CT was significantly more accurate (P < 0.05) in stages II and III compared with all other techniques. CT and MRI were not able to detect distant metastases in 2 patients, which changed therapy (operable vs. inoperable). Interobserver variability was 0.7, 0.9, 0.8, 1.0 in stage II and 0.9, 0.9, 0.9, 1.0 in stage III. CONCLUSION: PET/CT makes it possible to stage patients with limited MPM with high accuracy and low interobserver variability.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Mesotelioma/diagnóstico , Tomografia por Emissão de Pósitrons/instrumentação , Idoso , Feminino , Humanos , Avaliação de Estado de Karnofsky , Masculino , Mesotelioma/fisiopatologia , Pessoa de Meia-Idade , Estadiamento de Neoplasias/instrumentação , Estadiamento de Neoplasias/métodos , Tomografia Computadorizada por Raios X/instrumentação
8.
J Nucl Med ; 49 Suppl 2: 43S-63S, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18523065

RESUMO

Molecular imaging of tumor metabolism has gained considerable interest, since preclinical studies have indicated a close relationship between the activation of various oncogenes and alterations of cellular metabolism. Furthermore, several clinical trials have shown that metabolic imaging can significantly impact patient management by improving tumor staging, restaging, radiation treatment planning, and monitoring of tumor response to therapy. In this review, we summarize recent data on the molecular mechanisms underlying the increased metabolic activity of cancer cells and discuss imaging techniques for studies of tumor glucose, lipid, and amino acid metabolism.


Assuntos
Transformação Celular Neoplásica/metabolismo , Neoplasias/metabolismo , Aminoácidos/metabolismo , Animais , Transporte Biológico , Transformação Celular Neoplásica/patologia , Estruturas Celulares/metabolismo , Fluordesoxiglucose F18 , Glucose/metabolismo , Humanos , Metabolismo dos Lipídeos , Imageamento por Ressonância Magnética , Neoplasias/diagnóstico por imagem , Neoplasias/patologia , Oncogenes/fisiologia , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos
9.
Invest Radiol ; 43(5): 290-7, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18424949

RESUMO

OBJECTIVE: To evaluate and compare positron emission tomography/computed tomography (PET/CT) with whole-body magnetic resonance imaging (wbMRI) in the correct staging of patients with advanced nonsmall cell lung cancer (NSCLC). MATERIALS AND METHODS: Fifty-two patients with an NSCLC stage IIIa or IIIb (36 males and 16 females) were included in this study. Patients were referred to our department for restaging. Within 1 week PET/CT and wbMRI were performed in all patients. Images were examined independently by 2 experienced physicians from the Department of Nuclear Medicine and Radiology. Afterward, consensus reading was performed. In 22 patients, surgery served as gold standard, whereas in 30 patients, follow-up controls (after 2 months) were performed. RESULTS: The use of wbMRI correctly T-staged all patients. Especially volume interpolated breathhold examination sequence correctly T-staged all tumors. PET/CT did not correctly stage chest wall infiltration in 4 cases [sensitivity 92.3% (P < 0.05 to wbMRI)/specificity 100%], verified by surgery. PET/CT correctly N-staged 51 patients (sensitivity 96.1%/specificity 100%). WbMRI showed a significant tendency to understage N-status [sensitivity 88.5% (P < 0.05)/specificity 96.1%]. Different N-status by PET/CT changed operability in 4 patients. In 2 patients, distant metastases were detected by both techniques. CONCLUSION: In the correct staging of advanced NSCLC, PET/CT has advantages in N-staging. This is of high relevance for therapy planning. WbMRI especially using volume interpolated breathhold examination sequences, has certain advantages in T-staging.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/diagnóstico , Pulmão/patologia , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Imagem Corporal Total/métodos , Idoso , Carcinoma Pulmonar de Células não Pequenas/cirurgia , Meios de Contraste/administração & dosagem , Feminino , Fluordesoxiglucose F18 , Seguimentos , Humanos , Aumento da Imagem/métodos , Iohexol/análogos & derivados , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
Eur Radiol ; 18(8): 1635-43, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18369634

RESUMO

To evaluate and compare early therapy response according to RECIST (response evaluation criteria in solid tumours) and modified RECIST criteria using MRI techniques in patients with malignant pleural mesothelioma (MPM) in comparison with CT. Fifty patients with MPM (32 male/18 female) were included in this study. Early therapy response was evaluated after 9 weeks [three of six chemotherapy (CHT)] cycles. Additionally patients were examined before chemotherapy, 4 weeks after early therapy response evaluation and after six cycles to evaluate diagnostic follow-up. RECIST and modified RECIST criteria were applied using CT and MRI (HASTE, VIBE, T2-TSE sequences). In MRI additionally a volumetric approach measuring tumour weight (overall segmented tumour volume) was applied. Additionally vital capacity (VC) was measured for correlation. Image interpretation was performed by three independent readers independently and in consensus. The 'gold standard' was follow-up examination. Twenty-eight patients showed partial response, 12 patients stable disease and 10 patients progressive disease at early therapy response evaluation. In the follow-up these results remained. For MRI, in 46 cases patients were identically classified using RECIST and modified RECIST criteria. Modified RECIST criteria were identically classified as gold standards in all cases, whereas using RECIST criteria in four cases there was a mismatch (partial response vs. stable disease). Modified RECIST kappa values showed better interobserver variability compared with RECIST criteria (kappa=0.9-1.0 vs. 0.7-1.0). For CT, in 44 cases patients were identically classified using RECIST and modified RECIST criteria. Modified RECIST criteria were identically classified as in gold standards in 48 out of 50 patients, whereas using RECIST criteria in 6 cases there was a mismatch (partial response vs. stable disease). Modified RECIST kappa values showed better interobserver variability compared with RECIST criteria (kappa=0.9-1.0 vs. 0.6-1.0). Modified RECIST criteria especially in combination with high-resolution MRI is a very accurate and reproducible technique to correctly evaluate early therapy response in MPM.


Assuntos
Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Mesotelioma/diagnóstico , Mesotelioma/terapia , Neoplasias Pleurais/diagnóstico , Neoplasias Pleurais/terapia , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde/métodos , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Resultado do Tratamento
11.
Invest Radiol ; 42(10): 715-25, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17984769

RESUMO

OBJECTIVES: As pulmonary complications are life limiting in patients with cystic fibrosis (CF), repeated chest imaging [chest x-ray, computed tomography (CT)] is needed for follow up. With the continuously rising life expectancy of CF patients, magnetic resonance imaging (MRI) as a radiation-free imaging modality might become more and more attractive. The goal of this study was to prospectively assess the value of MRI for evaluation of morphologic pulmonary CF-changes in comparison to established imaging modalities. MATERIALS AND METHODS: Thirty-one CF patients (19 female, 12 male; mean age 16.7 years) with stable lung disease were examined by MRI: HASTE, coronal/transversal (TR/TE/alpha/TA: infinite/28 ms/180 degrees /18 s), multi-detector computed tomography (MDCT) (30 patients): 120 kV, dose modulated mAs, and chest x-ray (21 patients). Image evaluation: random order, 4 chest radiologists in consensus; chest x-ray: modified Chrispin-Norman score; CT and MRI: modified Helbich score. The maximal attainable score for chest x-ray was 34, for MRI and CT 25. Median scores, Pearson correlation coefficients, Bland-Altman plots, and concordance of MRI to CT on a lobar and segmental basis were calculated. RESULTS: The median MRI and MDCT scores were 13 (min 3, max 20) respectively 13.5 (min 0, max 20). The median chest x-ray score was 14 (min 5, max 32). Pearson correlation coefficients: MRI/CT = 0.80, P < 0.0001; MRI/chest x-ray = 0.63, P < 0.0018; chest x-ray/CT = 0.75, P < 0.0001. The median lobe related concordance was 80% for bronchiectasis, 77% for mucus plugging, 93%, for sacculation/abscesses, and 100% for collapse/consolidation. CONCLUSIONS: Morphologic MRI of the lung in CF patients demonstrates comparable results to MDCT and chest x-ray. Because radiation exposure is an issue in CF patients, MRI might have the ability to be used as an appropriate alternative method for pulmonary imaging.


Assuntos
Fibrose Cística/patologia , Pneumopatias/patologia , Pulmão/patologia , Imageamento por Ressonância Magnética/instrumentação , Adolescente , Fibrose Cística/diagnóstico por imagem , Progressão da Doença , Feminino , Indicadores Básicos de Saúde , Humanos , Pulmão/diagnóstico por imagem , Pneumopatias/diagnóstico por imagem , Masculino , Estudos Prospectivos , Radiografia , Tomografia Computadorizada de Emissão/instrumentação
12.
J Magn Reson Imaging ; 26(6): 1523-9, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17968900

RESUMO

PURPOSE: To evaluate an optimized method for oxygen-enhanced MRI of the lung, using simultaneous electrocardiograph (ECG) and navigator triggering. To correlate oxygen-enhanced MRI with lung function tests assessing alveolar-capillary gas exchange. MATERIALS AND METHODS: A total of 12 healthy volunteers (aged 20-32 years) and 10 patients (aged 37-87 years) with interstitial lung diseases (ILD) underwent oxygen-enhanced MRI and pulmonary functional tests (PFTs) assessing alveolar-capillary gas exchange. The paradigm room-air-oxygen-room-air was acquired with a nonselective inversion-recovery half-Fourier single-shot turbo spin-echo sequence (inversion time = 1200 msec; acquisition time = 134.5 msec; slice thickness = 20 mm; matrix size = 128 x 128), using simultaneous double triggering (navigator plus ECG trigger). Cross-correlation was performed in regions of interest (ROIs) encompassing both lungs. The number of oxygen-activated pixels over the total number of pixels in the ROIs (OAP%) of volunteers and patients was compared. OAP%s were correlated with PFTs. RESULTS: The mean OAP% of patients was significantly lower than that of volunteers (36.7 vs. 81.7, P = 0.001). OAP% correlated with the transfer lung factor for carbon monoxide (Tlco) (r = 0.64; P = 0.002), the transfer coefficient (Kco) (r = 0.75; P = 0.001), the arterial partial pressure (r = 0.77; P < 0.001), and the saturation (r = 0.70; P < 0.001) of oxygen. CONCLUSION: Navigator-triggered oxygen-enhanced MRI of the lung may have a potential role in the quantitative assessment of lung function in ILD.


Assuntos
Doenças Pulmonares Intersticiais/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Eletrocardiografia , Estudos de Viabilidade , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Oxigênio/metabolismo , Troca Gasosa Pulmonar , Testes de Função Respiratória , Mecânica Respiratória , Estatísticas não Paramétricas
13.
Invest Radiol ; 42(9): 605-13, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17700275

RESUMO

OBJECTIVE: To evaluate the clinical potential of diffusion-weighted-imaging (DWI) with apparent diffusion coefficient (ADC)-mapping for tumor detection. MATERIALS AND METHODS: A single-shot echo-planar-imaging DWI sequence with fat suppression and ability for navigator-based respiratory triggering was implemented. Nineteen patients (11 melanoma, 4 prostate cancer, 1 non-Hodgkin lymphoma, and 3 lung cancer) were examined by positron emission tomography (PET) with an integrated computed tomography scanner (PET-CT) and DWI. Images at b = 0, 400, and 1000 s/mm2 were acquired and ADC maps were generated. PET examinations were used as a reference for tumor detection. Four hundred twenty-four regions of interest were used for DWI and 73 for PET data evaluation. RESULTS: DWI and ADC maps were of diagnostic quality. Metastases with increased tracer uptake were clearly visualized at b = 1000 s/mm2 with the exception of mediastinal lymph node metastases in cases of lung cancer. ADC mapping did not improve detection rates. CONCLUSIONS: DWI is a feasible clinical technique, improving the assessment of metastatic spread in routine magnetic resonance imaging examinations.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Neoplasias/diagnóstico , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Técnica de Subtração
14.
Eur J Cancer ; 43(3): 557-64, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17224266

RESUMO

The aim of our study was to compare the overall and site-based accuracy and impact on patient management of positron emission tomography/computed tomography (PET/CT) and whole-body (wb) magnetic resonance imaging (MRI) in staging of advanced melanoma. In a prospective blinded study, 64 patients with American Joint Committee on Cancer (AJCC) stage III/IV melanoma underwent 18F-fluorodeoxyglucose PET/CT and wbMRI. In total 420 lesions were evaluated. The overall accuracy of PET/CT was 86.7% compared to 78.8% for wbMRI (P=0.0007). PET/CT was significantly more accurate in N-staging and detecting of skin and subcutaneous metastases, whereas wbMRI was more sensitive in detecting liver, bone and brain metastases. WbMRI was less sensitive but more specific than PET/CT in classifying pulmonary lesions. In 41 patients (64%) whole-body imaging caused changes of treatment. Whole-body staging of patients with advanced melanoma is most accurate by combining wbPET/CT and organ-specific wbMRI including a brain, liver and bone marrow protocol.


Assuntos
Fluordesoxiglucose F18 , Melanoma/diagnóstico , Neoplasias Cutâneas/diagnóstico , Adulto , Idoso , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Melanoma/terapia , Pessoa de Meia-Idade , Estadiamento de Neoplasias/métodos , Tomografia por Emissão de Pósitrons/métodos , Padrões de Referência , Neoplasias Cutâneas/terapia , Tomografia Computadorizada por Raios X , Imagem Corporal Total/métodos
15.
Eur Radiol ; 17(3): 716-24, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16941092

RESUMO

Cystic fibrosis (CF) is the most frequent inherited disorder leading to premature death in the Caucasian population. As life expectancy is limited by pulmonary complications, repeated imaging [chest X-ray, multislice high-resolution computed tomography (MS-HRCT)] is required in the follow-up. Magnetic resonance imaging (MRI) of the lung parenchyma is a promising new diagnostic tool. Its value for imaging lung changes caused by CF compared with CT is demonstrated. MRI performs well when compared with CT, which serves as the gold standard. Its lack in spatial resolution is obvious, but advantages in contrast and functional assessment compensate for this limitation. Thus, MRI is a reasonable alternative for imaging the CF lung and should be introduced as a radiation-free modality for follow-up studies in CF patients. For further evaluation of the impact of MRI, systematic studies comparing MRI and conventional imaging modalities are necessary. Furthermore, the value of the additional functional MRI (fMRI) information has to be studied, and a scoring system for the morphological and functional aspect of MRI has to be established.


Assuntos
Brônquios/patologia , Fibrose Cística/diagnóstico por imagem , Fibrose Cística/patologia , Imageamento por Ressonância Magnética , Muco/metabolismo , Adolescente , Adulto , Broncografia , Criança , Feminino , Humanos , Masculino , Tomografia Computadorizada por Raios X
16.
Cancer Imaging ; 6: S140-4, 2006 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-17114068

RESUMO

Novel technology has made dynamic magnetic resonance imaging (MRI) of lung motion and lung tumour mobility during continuous respiration feasible. This might be beneficial for planning of radiotherapy of lung tumours, especially when using high precision techniques. This paper describes the recent developments to analyze and visualize pulmonary nodules during continuous respiration using MRI. Besides recent dynamic two-dimensional approaches to quantify motion of pulmonary nodules during respiration novel three-dimensional techniques are presented. Beyond good correlation to pulmonary function tests MRI also provides regional information about differences between tumour-bearing and non-tumour bearing lung and the restrictive effects of radiotherapy as well as the compensation by the contralateral lung.


Assuntos
Neoplasias Pulmonares/radioterapia , Imageamento por Ressonância Magnética/métodos , Movimento (Física) , Planejamento de Assistência ao Paciente , Tomografia Computadorizada por Raios X/métodos , Sistemas Computacionais , Humanos , Imageamento Tridimensional , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Radioterapia/efeitos adversos , Respiração , Mecânica Respiratória , Carga Tumoral
17.
AJR Am J Roentgenol ; 187(2): 439-44, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16861549

RESUMO

OBJECTIVE: The purpose of this study was to use phase-contrast MRI to evaluate the influence of various breathing maneuvers on the hemodynamics of the pulmonary and systemic arterial circulation. SUBJECTS AND METHODS: Twenty-five volunteers were examined with phase-contrast MRI. Flow measurements were acquired in the aorta, pulmonary trunk, and left and right pulmonary arteries during deep, large-volume inspiratory breath-hold, expiratory breath-hold, and smooth respiration (no breath-hold). Parameters assessed were peak velocity, blood flow, velocity gradient, and acceleration time. RESULTS: Pulmonary blood flow and peak velocity were significantly reduced during inspiratory breath-hold and expiratory breath-hold compared with no breath-hold (p < 0.01). Pulmonary velocity gradient in inspiratory breath-hold was significantly (p

Assuntos
Circulação Sanguínea/fisiologia , Hemodinâmica/fisiologia , Imageamento por Ressonância Magnética , Circulação Pulmonar/fisiologia , Respiração , Adulto , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade
18.
Radiology ; 240(2): 537-45, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16801367

RESUMO

The purpose of this study was to prospectively evaluate the volumes and rotations of pulmonary nodules during respiration by using three-dimensional fast low-angle shot dynamic magnetic resonance (MR) imaging (1.5/0.6 [repetition time msec/echo time msec], 3.8 x 3.8 x 3.8-mm voxel size, imaging time per three-dimensional data set of 1 second). The feasibility of the technique was verified by using 130-, 40-, and 12-cm3 phantoms made of meatballs and in five patients with solitary intrapulmonary tumors (four men, one woman; median age, 60 years) at computed tomography and histologic analysis. All patients provided written informed consent, and the study was institutional review board approved. It was proved that there were no substantial differences among the 21 algorithms used to correct partial volume effects. The most precise algorithm (r > 0.9, P < .01) used to correct partial volume effects--with which mean phantom volumes of 120.8 cm3 +/- 4.1, 36.1 cm3 +/- 3.98, and 13.1 cm3 +/- 1.5 were calculated--yielded a root mean square error of 14%. The MR imaging-derived nodule volume and rotation during respiration could be quantified by using oriented bounding box techniques.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Neoplasias Pulmonares/patologia , Imageamento por Ressonância Magnética/métodos , Idoso , Algoritmos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Estudos Prospectivos , Respiração , Estatísticas não Paramétricas
19.
Eur Radiol ; 16(10): 2147-52, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16673092

RESUMO

This paper is a feasibility study of magnetic resonance imaging (MRI) of lung perfusion in children with cystic fibrosis (CF) using contrast-enhanced 3D MRI. Correlation assessment of perfusion changes with structural abnormalities. Eleven CF patients (9 f, 2 m; median age 16 years) were examined at 1.5 T. Morphology: HASTE coronal, transversal (TR/TE/alpha/ST: 600 ms/28 ms/180 degrees /6 mm), breath-hold 18 s. Perfusion: Time-resolved 3D GRE pulse sequence (FLASH, TE/TR/alpha: 0.8/1.9 ms/40 degrees ), parallel imaging (GRAPPA, PAT 2). Twenty-five data sets were acquired after intravenous injection of 0.1 mmol/kg body weight of gadodiamide, 3-5 ml/s. A total of 198 lung segments were analyzed by two radiologists in consensus and scored for morphological and perfusion changes. Statistical analysis was performed by Mantel-Haenszel chi-square test. Results showed that perfusion defects were observed in all patients and present in 80% of upper, and 39% of lower lobes. Normal lung parenchyma showed homogeneous perfusion (86%, P<0.0001). Severe morphological changes led to perfusion defects (97%, P<0.0001). Segments with moderate morphological changes showed normal (53%) or impaired perfusion (47%). In conclusion, pulmonary perfusion is easy to judge in segments with normal parenchyma or severe changes. In moderately damaged segments, MRI of lung perfusion may help to better assess actual functional impairment. Contrast-enhanced 3D MRI of lung perfusion has the potential for early vascular functional assessment and therapy control in CF patients.


Assuntos
Fibrose Cística/fisiopatologia , Imageamento Tridimensional , Pulmão/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Distribuição de Qui-Quadrado , Criança , Meios de Contraste/administração & dosagem , Estudos de Viabilidade , Feminino , Gadolínio DTPA/administração & dosagem , Humanos , Pulmão/irrigação sanguínea , Masculino
20.
Invest Radiol ; 41(5): 443-8, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16625107

RESUMO

PURPOSE: To monitor lung motion in patients with malignant pleural mesothelioma (MPM) before and after chemotherapy (CHT) using 2-dimensional (2D) and 3-dimensional (3D) dynamic MRI (dMRI) in comparison with spirometry. METHODS AND MATERIALS: Twenty-two patients with MPM were examined before CHT, as well as after 3 and 6 CHT cycles (3 months and 6 months) using 2D dMRI (trueFISP; 3 images/s) and 3D dMRI (FLASH 3D, 1 slab (52 slices)/s) using parallel imaging in combination with view-sharing technique. Maximum craniocaudal lung dimensions (2D) and lung volumes (3D) were monitored, separated into the tumor-bearing and nontumor-bearing hemithorax. Vital capacity (VC) was measured for comparison using spirometry. RESULTS: Using 2D technique, there was a significant difference between the tumor-bearing and the nontumor-bearing hemithorax before CHT (P < 0.01) and after 3 CHT cycles (P < 0.05), whereas difference was not significant in the second control. In the tumor-bearing hemithorax, mobility increased significantly from the status before versus after 3 CHT cycles (4.1 +/- 1.1 cm vs. 4.8 +/- 1.4 cm, P < 0.05). Using 3D technique, at maximum inspiration, the volume of the tumor-bearing hemithorax was 0.6 +/- 0.4 L and of the nontumor-bearing hemithorax 1.25 +/- 0.4 L before CHT. In the follow-up exams, these volumes changed to 1.05 +/- 0.4 L (P < 0.05) and 1.4 +/- 0.5 L, respectively. Using spirometry, there was no significant change in VC (1.9 +/- 0.4 L vs. 2.2 +/- 0.7 L vs. 2.2 +/- 0.9 L). CONCLUSION: dMRI is capable of monitoring changes in lung motion and volumetry in patients with MPM not detected by global spirometry. Thus, dMRI is proposed for use as a further measure of therapy response.


Assuntos
Imageamento Tridimensional , Pulmão/patologia , Imageamento por Ressonância Magnética , Mesotelioma/fisiopatologia , Neoplasias Pleurais/fisiopatologia , Idoso , Antineoplásicos/uso terapêutico , Feminino , Humanos , Medidas de Volume Pulmonar , Masculino , Mesotelioma/tratamento farmacológico , Pessoa de Meia-Idade , Movimento , Neoplasias Pleurais/tratamento farmacológico , Espirometria , Capacidade Vital
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...