Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Langenbecks Arch Surg ; 407(3): 1291-1301, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35088143

RESUMO

BACKGROUND: Parastomal hernia after radical cystectomy and ileal conduit urinary diversion is an underestimated and undertreated condition with significant impact on quality of life. However, its surgical treatment is challenging and prone to complications and the optimal surgical treatment of this condition remains to be determined. METHODS: In this article, we describe our surgical techniques in the minimally invasive treatment of ileal conduit parastomal hernia and present our preliminary results. In a retrospective single-center design, a prospectively maintained database was screened. Data from all patients undergoing surgical treatment for a parastomal hernia after cystectomy and ileal conduit urinary diversion in our center were collected. RESULTS: Between May 2016 and June 2020, 15 patients underwent minimally invasive repair of a parastomal hernia of an ileal conduit. Details on the surgical approach are provided, along with a flow chart to standardize the choice of surgical technique, depending on the presence of a concomitant midline incisional hernia and perioperative findings. The majority of patients were treated with robotic-assisted laparoscopic surgery (10/15; 66.7%). Median postoperative hospital stay was 5 days. One-third of patients developed a postoperative urinary infection. Median follow-up was 366 days. One patient developed a local recurrence of her parastomal hernia on day 66 postoperatively, treated with intraperitoneal mesh. CONCLUSION: The minimally invasive surgical treatment of a parastomal hernia after ileal conduit urinary diversion poses specific perioperative challenges that require a broad surgical armamentarium and a tailored approach. Preliminary results confirm a significant morbidity after this type of surgery.


Assuntos
Hérnia Incisional , Estomas Cirúrgicos , Derivação Urinária , Feminino , Humanos , Hérnia Incisional/etiologia , Hérnia Incisional/cirurgia , Qualidade de Vida , Estudos Retrospectivos , Telas Cirúrgicas/efeitos adversos , Estomas Cirúrgicos/efeitos adversos , Derivação Urinária/efeitos adversos
2.
Surg Endosc ; 36(3): 2105-2112, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-33796906

RESUMO

BACKGROUND: Transabdominal prostatectomy results in scarring of the retropubic space and this might complicate subsequent preperitoneal dissection and mesh placement during minimally invasive inguinal hernia repair. Therefore, it suggested that an open anterior technique should be used rather than a minimally invasive posterior technique in these patients. METHODS: In this single-center study, a retrospective analysis of a prospectively maintained database was performed. All patients undergoing inguinal hernia repair after previous transabdominal prostatectomy were included in this analysis, and the feasibility, safety, and short-term outcomes of open and robotic-assisted laparoscopic inguinal hernia repair were compared. RESULTS: From 907 inguinal hernia operations performed between March 2015 and March 2020, 45 patients met the inclusion criteria. As the number of patients treated with conventional laparoscopy was very low (n = 2), their data were excluded from statistical analysis. An open anterior repair with mesh (Lichtenstein) was performed in 21 patients and a robotic-assisted laparoscopic posterior transabdominal repair (rTAPP) in 22. Patient characteristics between groups were comparable. A transurethral urinary catheter was placed during surgery in 17 patients, most often in the laparoscopic cases (15/22, 68.2%). In the rTAPP group, a higher proportion of patients was treated for a bilateral inguinal hernia (50%, vs 19% in the Lichtenstein group). There were no intraoperative complications and no conversions from laparoscopy to open surgery. No statistically significant differences between both groups were observed in the outcome parameters. At 4 weeks follow-up, more patients who underwent rTAPP had an asymptomatic seroma (22.7% vs 5% in the Lichtenstein group) and two patients were treated postoperatively for a urinary tract infection (4.7%). CONCLUSION: A robotic-assisted laparoscopic approach to inguinal hernia after previous transabdominal prostatectomy seems safe and feasible and might offer specific advantages in the treatment of bilateral inguinal hernia repairs.


Assuntos
Hérnia Inguinal , Laparoscopia , Procedimentos Cirúrgicos Robóticos , Hérnia Inguinal/etiologia , Hérnia Inguinal/cirurgia , Herniorrafia/métodos , Humanos , Laparoscopia/efeitos adversos , Masculino , Prostatectomia/efeitos adversos , Prostatectomia/métodos , Estudos Retrospectivos , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Procedimentos Cirúrgicos Robóticos/métodos , Telas Cirúrgicas , Resultado do Tratamento
3.
BJS Open ; 5(1)2021 01 08.
Artigo em Inglês | MEDLINE | ID: mdl-33609369

RESUMO

BACKGROUND: There has been a rapid adoption of robot-assisted laparoscopic inguinal hernia repair in the USA, despite a lack of proven clinical advantage and higher material cost. No studies have been published regarding the cost and outcome of robotic inguinal hernia surgery in a European Union setting. METHODS: A retrospective comparative study was performed on the early outcome and costs related to laparoscopic inguinal hernia repair, with either conventional or robot-assisted surgery. RESULTS: The study analysed 676 patients undergoing laparoscopic inguinal hernia repair (272 conventional and 404 robotic repairs). Conventional laparoscopic and robotic repair groups were comparable in terms of duration of surgery (57.6 versus 56.2 min respectively; P = 0.224), intraoperative complication rate (1.1 versus 1.2 per cent; P = 0.990), in-hospital complication rate (4.4 versus 4.5 per cent; P = 0.230) and readmission rate (3.3 versus 1.2 per cent; P = 0.095). There was a significant difference in hospital stay in favour of the robotic approach (P = 0.014), with more patients treated on an outpatient basis in the robotic group (59.2 per cent versus 70.0 per cent for conventional repair). At 4-week follow-up, equal numbers of seromas or haematomas were recorded in the conventional laparoscopic and robotic groups (13.3 versus 15.7 per cent respectively; P = 0.431), but significantly more umbilical wound infections were seen in the conventional group (3.0 per cent versus 0 per cent in the robotic group; P = 0.001). Robotic inguinal hernia repair was significantly more expensive overall, with a mean cost of €2612 versus €1963 for the conventional laparoscopic approach (mean difference €649; P < 0.001). CONCLUSION: Robot-assisted laparoscopic inguinal hernia repair was significantly more expensive than conventional laparoscopy. More patients were treated as outpatients in the robotic group. Postoperative complications were infrequent and mild.


Assuntos
Hérnia Inguinal/cirurgia , Herniorrafia/métodos , Procedimentos Cirúrgicos Robóticos/economia , Procedimentos Cirúrgicos Robóticos/instrumentação , Procedimentos Cirúrgicos Robóticos/métodos , Análise Custo-Benefício , Feminino , Herniorrafia/economia , Humanos , Laparoscopia/economia , Laparoscopia/métodos , Tempo de Internação , Masculino , Análise Multivariada , Duração da Cirurgia , Avaliação de Resultados em Cuidados de Saúde , Complicações Pós-Operatórias , Estudos Retrospectivos
4.
Hernia ; 22(6): 1101-1111, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30244344

RESUMO

PURPOSE: The use of extraperitoneal mesh in place of intra-peritoneal mesh is gaining popularity in laparoscopic ventral hernia repair. We have adopted a robotic assisted laparoscopic technique using a lateral single-dock robotic access with retromuscular mesh placement after opening the ipsilateral posterior rectus fascia. In this study, we wanted to evaluate the changes in operative times during the initial experience with this novel technique. METHODS: The initial consecutive patients undergoing robotic assisted transabdominal retromuscular umbilical prosthetic repair (r-TARUP) using a 15 × 15 cm self-fixating mesh were prospectively entered in the study and the operative times during the separate steps of the surgical procedure were recorded. Complications were reported up to 4 week post operatively and quality of life was assessed using the EuraHS-QoL score. RESULTS: Over a 5 month inclusion period, 41 patients with either a primary (n = 34) or a trocar site hernia (n = 7) at the umbilicus were identified. All hernias had a mean diameter of less than 4 cm. The total OR time decreased significantly during the learning curve (tertile 1: 126 min versus tertile 3: 102 min; p = 0.002) due to a decrease in the skin-to-skin operating time (tertile 1: 81 min versus tertile 3:61 min; p = 0.002). The decrease in the retromuscular dissection time was the most significant of all the steps that comprised the console time (p = 0.004). The non-surgical time did not decrease (p = 0.15). The operation was performed on an outpatient basis in 68% of patients and with a one-night-stay in 29%. No complications related to the introduction of the robotic technique for this approach were observed and the early outcome is promising, with favorable quality-of-life evaluation at 4 weeks. CONCLUSIONS: The decrease in operative time during the adoption of r-TARUP was mainly related to the improved efficiency in the dissection phase of the procedure. The technique is reproducible and safe and the operative time compares favorably to published operative times for laparoscopic and open retromuscular umbilical hernia repair.


Assuntos
Hérnia Umbilical/cirurgia , Herniorrafia/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Telas Cirúrgicas , Músculos Abdominais/cirurgia , Parede Abdominal/cirurgia , Adulto , Idoso , Dissecação , Feminino , Herniorrafia/instrumentação , Herniorrafia/estatística & dados numéricos , Humanos , Laparoscopia , Curva de Aprendizado , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Estudos Prospectivos , Implantação de Prótese/instrumentação , Implantação de Prótese/métodos
5.
J Clin Monit Comput ; 32(6): 969-976, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29569112

RESUMO

Induction of general anesthesia frequently induces arterial hypotension, which is often treated with a vasopressor, such as phenylephrine. As a pure α-agonist, phenylephrine is conventionally considered to solely induce arterial vasoconstriction and thus increase cardiac afterload but not cardiac preload. In specific circumstances, however, phenylephrine may also contribute to an increase in venous return and thus cardiac output (CO). The aim of this study is to describe the initial time course of the effects of phenylephrine on various hemodynamic variables and to evaluate the ability of advanced hemodynamic monitoring to quantify these changes through different hemodynamic variables. In 24 patients, after induction of anesthesia, during the period before surgical stimulus, phenylephrine 2 µg kg-1 was administered when the MAP dropped below 80% of the awake state baseline value for > 3 min. The mean arterial blood pressure (MAP), heart rate (HR), end-tidal CO2 (EtCO2), central venous pressure (CVP), stroke volume (SV), CO, pulse pressure variation (PPV), stroke volume variation (SVV) and systemic vascular resistance (SVR) were recorded continuously. The values at the moment before administration of phenylephrine and 5(T5) and 10(T10) min thereafter were compared. After phenylephrine, the mean(SD) MAP, SV, CO, CVP and EtCO2 increased by 34(13) mmHg, 11(9) mL, 1.02(0.74) L min-1, 3(2.6) mmHg and 4.0(1.6) mmHg at T5 respectively, while both dynamic preload variables decreased: PPV dropped from 20% at baseline to 9% at T5 and to 13% at T10 and SVV from 19 to 11 and 14%, respectively. Initially, the increase in MAP was perfectly aligned with the increase in SVR, until 150 s after the initial increase in MAP, when both curves started to dissociate. The dissociation of the evolution of MAP and SVR, together with the changes in PPV, CVP, EtCO2 and CO indicate that in patients with anesthesia-induced hypotension, phenylephrine increases the CO by virtue of an increase in cardiac preload.


Assuntos
Anestesia Geral/efeitos adversos , Débito Cardíaco/efeitos dos fármacos , Monitorização Hemodinâmica/métodos , Hipotensão/tratamento farmacológico , Hipotensão/etiologia , Fenilefrina/uso terapêutico , Idoso , Feminino , Monitorização Hemodinâmica/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Fenilefrina/administração & dosagem , Estudos Prospectivos , Fatores de Tempo , Vasoconstritores/administração & dosagem , Vasoconstritores/uso terapêutico
6.
Hernia ; 20(2): 271-7, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26350395

RESUMO

BACKGROUND: Wounds resulting from the closure of temporary stomas have a high risk of developing an incisional hernia (IH) with incidences around 30% in studies designed to investigate this outcome. A temporary diverting ileostomy (TDI) is often used in patients after low anterior resection (LAR) for rectal cancer. METHODS: The OSTRICH study is a retrospective cohort study of rectal cancer patients who had a LAR with a reversed TDI and at least one CT scan during follow-up. Two radiologists independently evaluated all abdominal CT scans to diagnose IH at the ileostomy wound and additionally, IH at the laparotomy site. RESULTS: From the oncological database of rectal cancer patients treated from 2003 till 2012 (n = 317) a cohort of 153 patients that fulfilled the inclusion criteria was identified. Rectal cancer resection was performed by laparoscopy in 53 patients (34.6%) and by laparotomy in 100 patients (65.4%). A total of 17 IH (11.1%) was diagnosed at the former stoma site after a mean follow-up of 2.6 years. Of these, 8 IH were in patients who had a laparoscopic LAR (15.1%) and 9 IH in patients who had an open LAR (9.0%) (Fisher's exact test; p = 0.28). IH on the other abdominal wall incisions was reported in 69 patients (45.1%). Of these, 10 patients underwent laparoscopic rectal surgery (18.9%) and in 59 patients had open rectal surgery (59.0%) (Fisher's exact test; p < 0.0001). CONCLUSION: We found a lower number of incisional hernias (11.1%) after reversal of ileostomies than expected from the literature. In contrast to the findings at the ileostomy site, a very high frequency of IH (59.0%) after LAR by laparotomy was found, which was significantly higher than after laparoscopic LAR.


Assuntos
Ileostomia/efeitos adversos , Hérnia Incisional/diagnóstico por imagem , Neoplasias Retais/cirurgia , Idoso , Feminino , Humanos , Incidência , Hérnia Incisional/etiologia , Hérnia Incisional/cirurgia , Laparoscopia/efeitos adversos , Laparotomia/efeitos adversos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Estomas Cirúrgicos/efeitos adversos , Tomografia Computadorizada por Raios X
9.
Acta Clin Belg ; 69(1): 76-81, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24635405

RESUMO

We report the case of a 56-year-old male patient who was admitted to the emergency department with crescendo abdominal pain since 2 weeks. In the past 2 years, similar but less pronounced episodes were present, each time resolving spontaneously after spasmolytic drugs. Abdominal ultrasound revealed an ileocecal intussusception. An attempt for preoperative reduction was partially successful. A colonoscopy was performed and showed a tubulovillous adenomatous polyp with high-grade dysplasia, but subsequent right hemicolectomy revealed an underlying cecal adenocarcinoma. The combination of the low incidence and the non-specific symptoms of ileocecal intussusception in the adult makes this entity difficult to diagnose. In most cases, modern imaging techniques such as CT scan, ultrasound, or MRI make the correct preoperative diagnosis. Especially when colonic involvement is present, suspicion of a malignant lead point (i.e. culprit lesion) is primordial. The therapeutic strategy depends on several variables and asks for a patient-tailored, selective approach mostly involving surgery. Based on this case and a short review of literature, we discuss the clinical presentation, diagnostic tools, treatment, and challenges of adult ileocecal intussusception.


Assuntos
Doenças do Ceco/diagnóstico , Doenças do Ceco/cirurgia , Doenças do Íleo/diagnóstico , Doenças do Íleo/cirurgia , Intussuscepção/diagnóstico , Intussuscepção/cirurgia , Colectomia , Colonoscopia , Diagnóstico Diferencial , Humanos , Masculino , Pessoa de Meia-Idade
10.
Hernia ; 18(6): 797-802, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24445348

RESUMO

BACKGROUND: Incisional hernia (IH) is the most frequent complication after colorectal carcinoma (CRC) resection. The incidence depends on the method of follow-up, where ultrasound yields a significant number of additional hernias compared to clinical examination alone. Not many studies have evaluated the value of computed tomography (CT) to diagnose IH. METHODS: The CorreCT study is a retrospective cohort study of IH after CRC surgery by clinical examination and by CT, as reported in the medical files. Additional independent reviewing of all CTs by two radiologists was performed. RESULTS: From the oncological database (2004-2008) of the hospital, 598 patients with CRC were identified. The data of 448 consecutive patients who underwent surgery were analyzed. Tumors were resected by laparotomy in 366 patients (81.7 %), by laparoscopy in 76 patients (17.0 %) and by laparotomy after conversion in 6 patients (1.3 %). A clinical follow-up by the surgeon in 282 patients (62.9 %) with a mean duration of 33 months, yielded 49 patients with IH (17.4 %). The mean time of IH diagnosis (T1) was 19 months. Only 16 patients (33 %) underwent a hernia repair. For 363 patients (81.0 %), CT follow-up was available for a mean period of 30 months. In 84 patients (23.1 %), an IH was diagnosed with a mean T1 of 21 months. The review of all CTs by two independent radiologists yielded additional IH in 19 and 21 patients, respectively, increasing the IH rate to 29.1 and 29.7 %, respectively, and with a decrease in mean T1 to 14 months. The inter-observer agreement between the radiologists had a Kappa-statistic of 0.73 (95 % CI 0.65-0.81). For those patients with disagreement between the radiologists, a final agreement was made during an additional reviewing session of both radiologists, increasing the IH rate to 35.0 %. Comparing clinical follow-up, routine CT follow-up, and reassessed CT follow-up we found a statistically significant difference between the three methods of IH detection (p < 0.0001). CONCLUSION: CT follow-up can identify significantly more IH than clinical examination alone, in particular if the radiologist focuses on IH development. Furthermore, we showed that focused CT evaluation diagnosed IH 7 months earlier than routine CT and 5 months earlier than clinical follow-up alone.


Assuntos
Colectomia , Neoplasias Colorretais/cirurgia , Hérnia Abdominal , Complicações Pós-Operatórias , Idoso , Bélgica , Colectomia/efeitos adversos , Colectomia/métodos , Feminino , Seguimentos , Hérnia Abdominal/diagnóstico por imagem , Hérnia Abdominal/epidemiologia , Hérnia Abdominal/etiologia , Hérnia Abdominal/cirurgia , Herniorrafia/métodos , Humanos , Incidência , Laparoscopia , Laparotomia/efeitos adversos , Laparotomia/métodos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/cirurgia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
11.
Hernia ; 18(5): 671-80, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23881401

RESUMO

BACKGROUND: There is evidence that mesh repair for primary umbilical hernias results in less recurrences and similar wound complication rates compared to tissue repair. In recent years, several mesh devices for the repair of small ventral hernias have been developed, but some reports have been published on serious complications and adverse effects encountered with those mesh devices. METHODS: The Proceed™ Ventral Patch (PVP™) is a partially absorbable lightweight polypropylene mesh. We introduced PVP™ in our department in April 2009 and collected patient data and outcome in an observational study of 101 consecutive patients until December 2011 (Clinical.Trials.gov: NCT01307696). In addition to the routine control 3 weeks postoperative, prospective follow-up included a questionnaire, clinical investigation and ultrasound after 12 months. RESULTS: The study included 91 primary (76 umbilical/15 epigastric) and 10 incisional ventral hernias (including 6 trocar hernias). In all patients a PVP™ with a diameter of 6.4 cm was used. Wound problems were the most frequent complication (n = 18). Follow-up of at least 12 months was achieved in 98 patients (97 %) and the mean follow-up time was 15.9 months. Follow-up by clinical examination diagnosed a recurrence in 11/92 patients (12.0 %). Only four patients were aware of their recurrent hernia, the seven others reported no problems in the questionnaire. The additional ultrasound performed did not reveal recurrences that were not already diagnosed by clinical examination. In five patients a reoperation for repair of the recurrence was performed (reoperation rate 5/98 = 5.1 %). Hernia defect size (p = 0.032) and type of hernia (p = 0.029) were found to be a significant risk factors for development of a recurrent hernia (Fisher's exact test). Hernia size was a significant risk factor both in a univariate (p = 0.005) and in a multivariate Cox model (p = 0.017). Incisional hernia was of borderline significance in a univariate (p = 0.047) and in a multivariate Cox model (p = 0.08). CONCLUSION: Intensive clinical follow-up yields a high percentage (12.0 %) of clinically proven, but often asymptomatic recurrences after repair of small ventral hernias with the PVP™. Reoperation rate for recurrence was 5.1 %. Hernia defect size is a significant risk factor for recurrence. Therefore, we recommend using the PVP™ only for primary ventral hernias smaller than 2 cm. For larger or incisional hernias other techniques allowing the use of larger meshes is advocated.


Assuntos
Hérnia Ventral/cirurgia , Telas Cirúrgicas , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polipropilenos , Estudos Prospectivos , Resultado do Tratamento
12.
Hernia ; 17(5): 603-12, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23546864

RESUMO

BACKGROUND: Although laparoscopic intra-peritoneal mesh repair (LVHR) is a well-established treatment option to repair ventral and incisional hernias, no consensus in the literature can be found on the best method of fixation of the mesh to the abdominal wall. METHODS: Between December 2004 and July 2008, 76 patients undergoing a LVHR were randomized between mesh fixation using a double row of spiral tackers (DC) (n = 33) and mesh fixation with transfascial sutures combined with one row of spiral tackers (S&T) (n = 43), in the WoW trial (with or without sutures). Patients were clinically examined and evaluated using a visual analog scale for pain (VAS) in rest and after coughing 4 h post-operatively, after 4 weeks and 3 months after surgery. Primary endpoint of the study was abdominal wall pain, defined as a VAS score of at least 1.0 cm, at 3 months post-operative. Quality of life was quantified with the SF-36 questionnaire preoperatively and after 3 months. Secondary endpoint was the recurrence rate at 24-month follow-up. RESULTS: The DC and S&T group were comparable in age, gender, ASA score, BMI, indication, hernia, and mesh variables. The DC group had a significant shorter operating time compared with the S&T group (74 vs 96 min; p = 0.014) and a significant lower mean VAS score 4 h post-operatively (in rest; p = 0.028/coughing; p = 0.013). At 3 months, there were significant more patients in the S&T group with VAS score ≥1.0 cm (31.4 vs 8.3 %; p = 0.036). Clinical follow-up at 24 months was obtained in 63 patients (82.9 %). The recurrence rate at 24 months was 7.9 % overall (5/63). There were more recurrences in the S&T group (4/36) than in the DC group (1/27), but this difference was not significant (11.1 vs 3.7 %; p = 0.381). CONCLUSION: We found that double-crown fixation of intra-peritoneal mesh during laparoscopic ventral hernia repair was quicker, was less painful immediately post-operative and after 3 months, and did not increase the recurrence rate at 24 months. In hernias at a distance from the bony borders of the abdomen, transfascial sutures can be omitted if a double crown of tackers is placed.


Assuntos
Hérnia Ventral/cirurgia , Herniorrafia , Laparoscopia , Dor Pós-Operatória , Telas Cirúrgicas , Técnicas de Sutura , Técnicas de Fechamento de Ferimentos Abdominais/efeitos adversos , Adulto , Idoso , Feminino , Hérnia Ventral/fisiopatologia , Herniorrafia/efeitos adversos , Herniorrafia/instrumentação , Herniorrafia/métodos , Humanos , Laparoscopia/efeitos adversos , Laparoscopia/instrumentação , Laparoscopia/métodos , Masculino , Pessoa de Meia-Idade , Medição da Dor , Dor Pós-Operatória/diagnóstico , Dor Pós-Operatória/etiologia , Dor Pós-Operatória/fisiopatologia , Dor Pós-Operatória/prevenção & controle , Dor Pós-Operatória/psicologia , Qualidade de Vida , Prevenção Secundária , Índice de Gravidade de Doença , Resultado do Tratamento
13.
Hernia ; 15(4): 463-8, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20556448

RESUMO

Several mesh devices for the treatment of umbilical and other small ventral hernias have become available in recent years. These meshes have a dual layer consisting of a permanent or temporary barrier against adhesion formation between the viscera and the intraperitoneally exposed part of the mesh. We have seen several patients with serious late complications of these meshes placed intraperitoneally. Some of these patients needed small bowel resection and mesh removal. Others developed a recurrence because of improper deployment of the mesh in the intraperitoneal position. We think that, if preperitoneal deployment of such mesh devices is possible, this should be the preferred position, notwithstanding the fact that these meshes have a dual layer. There is a complete lack of convincing data on these mesh devices in the medical literature. No long-term data have been published, and, for three of the four mesh devices available, no publications on their use in humans were found. We think that surgeons adopting innovative mesh devices should register and follow their patients prospectively, at least until there are enough published studies with sufficiently large patient samples, acceptable follow up times, and favourable outcomes.


Assuntos
Perfuração Intestinal/etiologia , Intestino Delgado , Telas Cirúrgicas/efeitos adversos , Idoso , Feminino , Hérnia Umbilical/cirurgia , Herniorrafia/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese/efeitos adversos , Recidiva
14.
Intensive Care Med ; 33(7): 1297-1300, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17522843

RESUMO

OBJECTIVE: To compare intra-abdominal pressure (IAP) measurements obtained from an intragastric Compliance catheter with the pressure measured directly in the abdominal cavity. DESIGN AND SETTING: Prospective cohort study in an operating room of the Ghent University Hospital PATIENTS: Seven patients undergoing elective laparoscopic cholecystectomy. INTERVENTIONS: IAP was obtained from both an intragastric catheter and directly from the peritoneal cavity at 1-minute intervals in patients undergoing elective cholecystectomy and compared using Bland-Altman analysis. MEASUREMENTS AND RESULTS: In 156 paired measurements obtained from 7 patients the mean difference between IAPgastric and IAPref was 0.12+/-0.70 mmHg (95% CI 0.01-0.23). CONCLUSIONS: IAP measured using an intragastric Compliance catheter reliably reflects the reference IAP in patients undergoing laparoscopic cholecystectomy.


Assuntos
Cateterismo , Manometria/métodos , Colecistectomia Laparoscópica , Estudos de Coortes , Procedimentos Cirúrgicos Eletivos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cavidade Peritoneal , Estudos Prospectivos , Estômago
15.
Intensive Care Med ; 32(3): 455-9, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16477411

RESUMO

OBJECTIVE: The objective was to determine the minimum volume of instillation fluid for intra-abdominal pressure (IAP) measurement, and to evaluate the effect of instillation volume on transvesically measured IAP. DESIGN: Prospective cohort study SETTING: Twenty-two-bed surgical ICU of the Ghent University Hospital. PATIENTS AND PARTICIPANTS: Twenty patients at risk of intra-abdominal hypertension (IAH). INTERVENTIONS: Transvesical IAP measurement using volumes from 10 to 100 ml. Minimal volume at which an IAP was measured was recorded (IAP(min)), as well as IAP at 50 and 100 ml of instillation volume (IAP(50) and IAP(100)). The percentage difference for IAP(50) and IAP(100) was calculated. MEASUREMENTS AND RESULTS: The minimal volume for IAP measurement was 10 ml in all patients. Mean IAP(min) was 12.8 mmHg (+/- 4.9), mean IAP(50 )15 mmHg (+/- 4.5) and mean IAP(100) 17.1mmHg (+/- 4.7). The mean percentage difference for IAP(50) was 21% (+/- 17%), and 40% (+/-29%) for IAP(100.) Twelve patients were categorised as suffering from IAH when 10 ml of saline was used for IAP measurement, increasing to 15 and 17 patients respectively when using 50 and 100 ml. In patients with IAH, there was a significant correlation between the duration of bladder drainage and percentage difference for IAP(100) (Pearson correlation coefficient 0.60, p = 0.03). CONCLUSIONS: Using 50 or 100 ml of saline for IAP measurement in critically ill patients results in higher IAP values compared with the use of 10 ml, and possibly, in overestimation of the incidence of intra-abdominal hypertension.


Assuntos
Abdome , Síndromes Compartimentais/diagnóstico , Cuidados Críticos , Pressão , Cloreto de Sódio/administração & dosagem , Abdome/fisiologia , Administração Intravesical , Idoso , Bélgica , Estudos de Coortes , Síndromes Compartimentais/fisiopatologia , Estado Terminal , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos
16.
Acta Chir Belg ; 105(5): 504-7, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16315834

RESUMO

BACKGROUND: During the Belgian Surgical Week in May 2004 some controversy existed on the optimal treatment of spontaneous pneumothorax. Doubts raised about the safety of talc in performing pleurodesis because of reported complications. METHODS: A retrospective analysis of a consecutive series of thoracoscopic pleurodesis with talc was performed. Patients operated for spontaneous pneumothorax were analysed focusing on complications and freedom of recurrence. A literature search was performed on complications from the use of talc to treat pleural disease. RESULTS: From September 1999 till August 2004 forty-one patients had a thoracoscopic pleurodesis with talc. In 21 patients this was performed for recurrent malignant pleural effusion and in 20 for spontaneous pneumothorax. In 5 of these 20 patients we faced a secondary spontaneous pneumothorax. In seven patients an apical pulmonary wedge resection of bullae was performed. No intra-operative or serious postoperative complications were seen in these patients. All drains were removed after 4 to 6 days. No episodes of respiratory insufficiency occurred. No recurrence was encountered during a mean follow-up of 22.7 months. CONCLUSION: Thoracoscopic talc pleurodesis for spontaneous pneumothorax was effective and safe in our experience. In the literature no convincing evidence against the use of talc to treat pleural disease was found. Although some cases of ARDS are attributed to the pleural administration of talc, the incidence of complications after talc poudrage appears to be low.


Assuntos
Pleurodese/métodos , Pneumotórax/terapia , Talco/administração & dosagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Toracoscopia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...