Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biomaterials ; 229: 119577, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31704466

RESUMO

The durability of prosthetic arteriovenous (AV) grafts for hemodialysis access is low, predominantly due to stenotic lesions in the venous outflow tract and infectious complications. Tissue engineered blood vessels (TEBVs) might offer a tailor-made autologous alternative for prosthetic grafts. We have designed a method in which TEBVs are grown in vivo, by utilizing the foreign body response to subcutaneously implanted polymeric rods in goats, resulting in the formation of an autologous fibrocellular tissue capsule (TC). One month after implantation, the polymeric rod is extracted, whereupon TCs (length 6 cm, diameter 6.8 mm) were grafted as arteriovenous conduit between the carotid artery and jugular vein of the same goats. At time of grafting, the TCs were shown to have sufficient mechanical strength in terms of bursting pressure (2382 ±â€¯129 mmHg), and suture retention strength (SRS: 1.97 ±â€¯0.49 N). The AV grafts were harvested at 1 or 2 months after grafting. In an ex vivo whole blood perfusion system, the lumen of the vascular grafts was shown to be less thrombogenic compared to the initial TCs and ePTFE grafts. At 8 weeks after grafting, the entire graft was covered with an endothelial layer and abundant elastin expression was present throughout the graft. Patency at 1 and 2 months was comparable with ePTFE AV-grafts. In conclusion, we demonstrate the remodeling capacity of cellularized in vivo engineered TEBVs, and their potential as autologous alternative for prosthetic vascular grafts.


Assuntos
Implante de Prótese Vascular , Prótese Vascular , Artérias Carótidas/cirurgia , Veias Jugulares/cirurgia , Diálise Renal , Engenharia Tecidual , Grau de Desobstrução Vascular
2.
Biomech Model Mechanobiol ; 18(6): 1577-1590, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31069593

RESUMO

The vestibular system in the inner ear senses angular head manoeuvres by endolymph fluid which deforms a gelatinous sensory structure (the cupula). We constructed computer models that include both the endolymph flow (using CFD modelling), the cupula deformation (using FEM modelling), and the interaction between both (using fluid-structure interaction modelling). In the wide utricle, we observe an endolymph vortex. In the initial time steps, both the displacement of the cupula and its restorative forces are still small. As a result, the endolymph vortex causes the cupula to deform asymmetrically in an S-shape. The asymmetric deflection increases the cupula strain near the crista and, as a result, enhances the sensitivity of the vestibular system. Throughout the head manoeuvre, the maximal cupula strain is located at the centre of the crista. The hair cells at the crista centre supply irregularly spiking afferents, which are more sensitive than the afferents from the periphery. Hence, the location of the maximal strain at the crista may also increase the sensitivity of the semicircular canal, but this remains to be tested. The cupula overshoots its relaxed position in a simulation of the Dix-Hallpike head manoeuvre (3 s in total). A much faster head manoeuvre of 0.222 s showed to be too short to cause substantial cupula overshoot, because the cupula time scale of both models (estimated to be 3.3 s) is an order of magnitude larger than the duration of this manoeuvre.


Assuntos
Endolinfa/fisiologia , Canais Semicirculares/patologia , Adulto , Feminino , Humanos , Masculino , Modelos Biológicos , Pressão , Estresse Mecânico
3.
Opt Express ; 21(22): 26093-102, 2013 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-24216833

RESUMO

We describe a novel measurement method to study the contact line of a droplet at nanoscale level. The method is based on Total Internal Reflection Fluorescence Microscopy (TIRFM), which uses an evanescent excitation field produced by total internal reflection of light. The evanescent field depends on the angle of the incident light and has an exponential intensity decay, characterized by the penetration depth. The penetration depth is determined by imaging a fluorescent particle probe that is traversed using an Atomic Force Microscopy (AFM) setup. The result confirms the exponential behavior of the evanescent field intensity, and the value of the penetration depth also corresponds with the value predicted based on the optical configuration. By using the intensity distribution of a fluorescent dye and the value for the penetration depth of the evanescent wave, it is possible to reconstruct the interface of a partial wetting droplet. The reconstructed interface based on TIRFM is in good agreement with the interface obtained from two reference measurements: non-disturbing AFM-imaging and conventional contact angle measurement. The latter lacks spatial resolution, while the former is limited to particular droplets. This new non-contact measurement does not suffer from these drawbacks, making it a very useful tool to study the fundamental wetting behavior of both stationary and dynamic interfaces.


Assuntos
Microscopia de Força Atômica/instrumentação , Microscopia de Fluorescência/instrumentação , Imagem Molecular/instrumentação , Nanopartículas/ultraestrutura , Nanotecnologia/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
NMR Biomed ; 25(1): 14-26, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21480417

RESUMO

The aim of this study was to validate the flow patterns measured by high-resolution, time-resolved, three-dimensional phase contrast MRI in a real-size intracranial aneurysm phantom. Retrospectively gated three-dimensional phase contrast MRI was performed in an intracranial aneurysm phantom at a resolution of 0.2 × 0.2 × 0.3 mm(3) in a solenoid rat coil. Both steady and pulsatile flows were applied. The phase contrast MRI measurements were compared with particle image velocimetry measurements and computational fluid dynamics simulations. A quantitative comparison was performed by calculating the differences between the magnitude of the velocity vectors and angles between the velocity vectors in corresponding voxels. Qualitative analysis of the results was executed by visual inspection and comparison of the flow patterns. The root-mean-square errors of the velocity magnitude in the comparison between phase contrast MRI and computational fluid dynamics were 5% and 4% of the maximum phase contrast MRI velocity, and the medians of the angle distribution between corresponding velocity vectors were 16° and 14° for the steady and pulsatile measurements, respectively. In the phase contrast MRI and particle image velocimetry comparison, the root-mean-square errors were 12% and 10% of the maximum phase contrast MRI velocity, and the medians of the angle distribution between corresponding velocity vectors were 19° and 15° for the steady and pulsatile measurements, respectively. Good agreement was found in the qualitative comparison of flow patterns between the phase contrast MRI measurements and both particle image velocimetry measurements and computational fluid dynamics simulations. High-resolution, time-resolved, three-dimensional phase contrast MRI can accurately measure complex flow patterns in an intracranial aneurysm phantom.


Assuntos
Meios de Contraste , Hidrodinâmica , Aneurisma Intracraniano/fisiopatologia , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Reologia/métodos , Animais , Velocidade do Fluxo Sanguíneo/fisiologia , Simulação por Computador , Fluxo Pulsátil/fisiologia , Ratos , Reprodutibilidade dos Testes
5.
J R Soc Interface ; 7(42): 91-103, 2010 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-19401309

RESUMO

In order to study the role of blood-tissue interaction in the developing chicken embryo heart, detailed information about the haemodynamic forces is needed. In this study, we present the first in vivo measurements of the three-dimensional distribution of wall shear stress (WSS) in the outflow tract (OFT) of an embryonic chicken heart. The data are obtained in a two-step process: first, the three-dimensional flow fields are measured during the cardiac cycle using scanning microscopic particle image velocimetry; second, the location of the wall and the WSS are determined by post-processing flow velocity data (finding velocity gradients at locations where the flow approaches zero). The results are a three-dimensional reconstruction of the geometry, with a spatial resolution of 15-20 microm, and provides detailed information about the WSS in the OFT. The most significant error is the location of the wall, which results in an estimate of the uncertainty in the WSS values of 20 per cent.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Embrião de Galinha/fisiologia , Coração/embriologia , Coração/fisiologia , Microscopia Confocal/métodos , Modelos Cardiovasculares , Reologia/métodos , Animais , Galinhas , Simulação por Computador , Resistência ao Cisalhamento/fisiologia
6.
Phys Rev E Stat Nonlin Soft Matter Phys ; 69(5 Pt 2): 056311, 2004 May.
Artigo em Inglês | MEDLINE | ID: mdl-15244936

RESUMO

A recently developed theoretical model for a turbulently flowing suspension has been applied to a homogeneous, isotropic, and decaying turbulent suspension. The predictions are compared with results from direct numerical simulations. The agreement is reasonable. Special attention is paid to a physical explanation of the influence of the particles on the turbulence of the carrier fluid.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...