Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Chemistry ; 30(35): e202400783, 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38629399

RESUMO

Glycosaminoglycans (GAGs) are linear and acidic polysaccharides. They are ubiquitous molecules, which are involved in a wide range of biological processes. Despite being structurally simple at first glance, with a repeating backbone of alternating hexuronic acid and hexosamine dimers, GAGs display a highly complex structure, which predominantly results from their heterogeneous sulfation patterns. The commonly applied method for compositional analysis of all GAGs is "disaccharide analysis." In this process, GAGs are enzymatically depolymerized into disaccharides, derivatized with a fluorescent label, and then analysed through liquid chromatography. The limiting factor in the high throughput analysis of GAG disaccharides is the time-consuming liquid chromatography. To address this limitation, we here utilized trapped ion mobility-mass spectrometry (TIM-MS) for the separation of isomeric GAG disaccharides, which reduces the measurement time from hours to a few minutes. A full set of disaccharides comprises twelve structures, with eight possessing isomers. Most disaccharides cannot be differentiated by TIM-MS in underivatized form. Therefore, we developed chemical modifications to reduce sample complexity and enhance differentiability. Quantification is performed using stable isotope labelled standards, which are easily available due to the nature of the performed modifications.


Assuntos
Dissacarídeos , Glicosaminoglicanos , Dissacarídeos/química , Dissacarídeos/análise , Glicosaminoglicanos/química , Glicosaminoglicanos/análise , Espectrometria de Mobilidade Iônica/métodos , Espectrometria de Massas/métodos , Isomerismo , Cromatografia Líquida/métodos
2.
Nat Commun ; 15(1): 2611, 2024 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-38521783

RESUMO

The dense O-glycosylation of mucins plays an important role in the defensive properties of the mucus hydrogel. Aberrant glycosylation is often correlated with inflammation and pathology such as COPD, cancer, and Crohn's disease. The inherent complexity of glycans and the diversity in the O-core structure constitute fundamental challenges for the analysis of mucin-type O-glycans. Due to coexistence of multiple isomers, multidimensional workflows such as LC-MS are required. To separate the highly polar carbohydrates, porous graphitized carbon is often used as a stationary phase. However, LC-MS workflows are time-consuming and lack reproducibility. Here we present a rapid alternative for separating and identifying O-glycans released from mucins based on trapped ion mobility mass spectrometry. Compared to established LC-MS, the acquisition time is reduced from an hour to two minutes. To test the validity, the developed workflow was applied to sputum samples from cystic fibrosis patients to map O-glycosylation features associated with disease.


Assuntos
Mucinas , Espectrometria de Massas em Tandem , Humanos , Mucinas/metabolismo , Espectrometria de Massas em Tandem/métodos , Reprodutibilidade dos Testes , Polissacarídeos/química , Glicosilação
3.
J Am Soc Mass Spectrom ; 34(10): 2403-2406, 2023 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-37602654

RESUMO

Nanoelectrospray ionization (nano-ESI) is a highly efficient and a widely used technique for the ionization of minute amounts of analyte. Offline nano-ESI sources are convenient for the direct infusion of complex mixtures that suffer from high matrix content and are crucial for the native mass spectrometric analysis of proteins. For Bruker instruments, no such source is readily available. Here we close this gap and present a 3D-printable nano-ESI source for Bruker instruments, which can be assembled by anyone with access to 3D printers. The source can be fitted to any Bruker mass spectrometer with an ionBooster ESI source and only requires minor, reversible changes to the original Bruker hardware. The general utility was demonstrated by recording high-resolution MS spectra of small molecules, intact proteins, as well as complex biological samples in negative and positive ion mode on two different Bruker instruments.

4.
Anal Chem ; 94(39): 13323-13331, 2022 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-36121379

RESUMO

Complex carbohydrates are ubiquitous in nature and represent one of the major classes of biopolymers. They can exhibit highly diverse structures with multiple branched sites as well as a complex regio- and stereochemistry. A common way to analytically address this complexity is liquid chromatography (LC) in combination with mass spectrometry (MS). However, MS-based detection often does not provide sufficient information to distinguish glycan isomers. Ion mobility-mass spectrometry (IM-MS)─a technique that separates ions based on their size, charge, and shape─has recently shown great potential to solve this problem by identifying characteristic isomeric glycan features such as the sialylation and fucosylation pattern. However, while both LC-MS and IM-MS have clearly proven their individual capabilities for glycan analysis, attempts to combine both methods into a consistent workflow are lacking. Here, we close this gap and combine hydrophilic interaction liquid chromatography (HILIC) with IM-MS to analyze the glycan structures released from human alpha-1-acid glycoprotein (hAGP). HILIC separates the crude mixture of highly sialylated multi-antennary glycans, MS provides information on glycan composition, and IMS is used to distinguish and quantify α2,6- and α2,3-linked sialic acid isomers based on characteristic fragments. Further, the technique can support the assignment of antenna fucosylation. This feature mapping can confidently assign glycan isomers with multiple sialic acids within one LC-IM-MS run and is fully compatible with existing workflows for N-glycan analysis.


Assuntos
Espectrometria de Mobilidade Iônica , Ácido N-Acetilneuramínico , Humanos , Íons , Orosomucoide , Polissacarídeos/química , Ácidos Siálicos/análise
5.
J Am Chem Soc ; 143(36): 14827-14834, 2021 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-34473927

RESUMO

Mass spectrometry is routinely employed for structure elucidation of molecules. Structural information can be retrieved from intact molecular ions by fragmentation; however, the interpretation of fragment spectra is often hampered by poor understanding of the underlying dissociation mechanisms. For example, neutral headgroup loss from protonated glycerolipids has been postulated to proceed via an intramolecular ring closure but the mechanism and resulting ring size have never been experimentally confirmed. Here we use cryogenic gas-phase infrared (IR) spectroscopy in combination with computational chemistry to unravel the structures of fragment ions and thereby shed light on elusive dissociation mechanisms. Using the example of glycerolipid fragmentation, we study the formation of protonated five-membered dioxolane and six-membered dioxane rings and show that dioxolane rings are predominant throughout different glycerolipid classes and fragmentation channels. For comparison, pure dioxolane and dioxane ions were generated from tailor-made dehydroxyl derivatives inspired by natural 1,2- and 1,3-diacylglycerols and subsequently interrogated using IR spectroscopy. Furthermore, the cyclic structure of an intermediate fragment occurring in the phosphatidylcholine fragmentation pathway was spectroscopically confirmed. Overall, the results contribute substantially to the understanding of glycerolipid fragmentation and showcase the value of vibrational ion spectroscopy to mechanistically elucidate crucial fragmentation pathways in lipidomics.


Assuntos
Diglicerídeos/química , Fosfatidilcolinas/química , Fosfatidiletanolaminas/química , Lipidômica/métodos , Espectrofotometria Infravermelho/métodos
6.
Acc Chem Res ; 54(10): 2445-2456, 2021 05 18.
Artigo em Inglês | MEDLINE | ID: mdl-33900743

RESUMO

Ion mobility spectrometry and gas-phase IR action spectroscopy are two structure-sensitive mass-spectrometric methods becoming more popular recently. While ion mobility spectrometry provides collision cross sections as a size and shape dependent parameter of an ion of interest, gas-phase spectroscopy identifies functional groups and is capable of distinguishing different isomers. Both methods have recently found application for the investigation of supramolecular assemblies. We here highlight several aspects.Starting with the characterization of switching states in azobenzene photoswitches as well as redox-switchable lasso-type pseudorotaxanes, structures of isomers can be distinguished and mechanistic details analyzed. Ion mobility mass spectrometry in combination with gas-phase H/D-exchange reactions unravels subtle structural details as described for the chiral recognition of crown ether amino acid complexes. Gas-phase IR spectroscopy allows identification of details of the binding patterns in dimeric amino acid clusters as well as the serine octamer. This research can be extended into the analysis of peptide assemblies that are of medical relevance, for example, in Alzheimer's disease, and into a general hydrophobicity scale for natural as well as synthetic amino acids. The development of ultracold gas-phase spectroscopy that for example makes use of ions trapped in liquid helium droplets provides access to very well resolved spectra. The combination of ion mobility separation of ions with subsequent spectroscopic analysis even permits separation of different isomers and studying them separately with respect to their structure. This represents a great advantage of these gas-phase methods over solution experiments, in which the supramolecular complexes under study typically equilibrate and thus prevent a separate investigation of different isomers. At the end of this overview, we will discuss larger and more complex supramolecules, among them giant halogen-bonded cages and complex intertwined topologies such as molecular knots and Solomon links.

7.
Anal Bioanal Chem ; 412(3): 533-537, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31853603

RESUMO

Glycosaminoglycans (GAGs) are a physio- and pharmacologically highly relevant class of complex saccharides, possessing a linear sequence and strongly acidic character. Their repetitive linear core makes them seem structurally simple at first glance, yet differences in sulfation and epimerization lead to an enormous structural diversity with only a few GAGs having been successfully characterized to date. Recent infrared action spectroscopic experiments on sulfated mono- and disaccharide ions show great promise. Here, we assess the potential of two types of gas-phase action spectroscopy approaches in the range from 1000 to 1800 cm-1 for the structural analysis of complex GAG oligosaccharides. Synthetic tetra- and pentasaccharides were chosen as model compounds for this benchmark study. Utilizing infrared multiple photon dissociation action spectroscopy at room temperature, diagnostic bands are largely unresolved. In contrast, cryogenic infrared action spectroscopy of ions trapped in helium nanodroplets yields resolved infrared spectra with diagnostic features for monosaccharide composition and sulfation pattern. The analysis of GAGs could therefore significantly benefit from expanding the conventional MS-based toolkit with gas-phase cryogenic IR spectroscopy. Graphical abstract.


Assuntos
Glicosaminoglicanos/química , Oligossacarídeos/química , Espectrofotometria Infravermelho/métodos , Animais , Temperatura Baixa , Hélio/química , Humanos , Íons/química , Isomerismo , Espectrofotometria Infravermelho/instrumentação , Sulfatos/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...