Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Am J Cardiol ; 149: 78-85, 2021 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-33753040

RESUMO

Conduction disturbances remain common following transcatheter aortic valve implantation (TAVI). Aside from high-degree atrioventricular block (HAVB), their optimal management remains elusive. Invasive electrophysiological studies (EPS) may help stratify patients at low or high risk of HAVB allowing for an early discharge or permanent pacemaker (PPM) implantation among patients with conduction disturbances. We evaluated the safety and diagnostic performances of an EPS-guided PPM implantation strategy among TAVI recipients with conduction disturbances not representing absolute indications for PPM. All patients who underwent TAVI at a single expert center from June 2017 to July 2020 who underwent an EPS during the index hospitalization were included in the present study. False negative outcomes were defined as patients discharged without PPM implantation who required PPM for HAVB within 6 months of the initial EPS. False positive outcomes were defined as patients discharged with a PPM with a ventricular pacing percentage <1% at follow-up. A total of 78 patients were included (median age 83.5, 39% female), among whom 35 patients (45%) received a PPM following EPS. The sensitivity, specificity, positive and negative predictive values of the EPS-guided PPM implantation strategy were 100%, 89.6%, 81.5%, and 100%, respectively. Six patients suffered a mechanical HAVB during EPS and received a PPM. These 6 patients showed PPM dependency at follow-up. In conclusion, an EPS-guided PPM implantation strategy for managing post-TAVI conduction disturbances appears effective to identify patients who can be safely discharged without PPM implantation.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bloqueio Atrioventricular/terapia , Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial/métodos , Técnicas Eletrofisiológicas Cardíacas , Complicações Pós-Operatórias/terapia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Bloqueio Atrioventricular/fisiopatologia , Bloqueio de Ramo/fisiopatologia , Doença do Sistema de Condução Cardíaco/fisiopatologia , Doença do Sistema de Condução Cardíaco/terapia , Reações Falso-Negativas , Reações Falso-Positivas , Feminino , Humanos , Masculino , Marca-Passo Artificial , Complicações Pós-Operatórias/fisiopatologia , Implantação de Prótese/métodos , Resultado do Tratamento
3.
Arch Cardiovasc Dis ; 111(5): 340-348, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29133182

RESUMO

BACKGROUND: Atrial fibrillation ablation is often performed by achieving pulmonary vein isolation using the "wide antral circumferential ablation" (WACA) technique, but many pulmonary veins remain connected because of conduction gaps in the ablation line. AIM: To analyse the efficacy of a novel technique based on pacing manoeuvres to detect gaps in an initial WACA lesion. METHODS: Patients referred for radiofrequency atrial fibrillation ablation were enrolled prospectively. A WACA lesion set was performed, isolating ipsilateral pulmonary veins together. If pulmonary vein isolation was not achieved, the atria were paced using an ablation catheter. For each pacing site, "activation delay" and "activation sequence" were analysed using a circular mapping catheter positioned at the pulmonary vein ostium. RESULTS: Twenty-one patients were included. A total of 25 non-isolated WACA lesion sets were studied. Three patterns were identified: (1) the activation delays converged towards one point with the shortest delay; no modification of the activation sequence (indicating one gap); (2) the activation delays converged towards at least two close locations; no change in the activation sequence (indicating at least two close gaps); (3) the activation delays converged towards at least two remote locations; modification of the activation sequence (indicating at least two remote gaps). Pacing manoeuvres and effect of ablation allowed precise localization of gaps, ultimately leading to pulmonary vein isolation in all patients. CONCLUSION: This simple pacing method accurately detected the location of residual connections after WACA lesion sets performed for atrial fibrillation ablation, allowing pulmonary vein isolation to be achieved.


Assuntos
Fibrilação Atrial/cirurgia , Estimulação Cardíaca Artificial/métodos , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Recidiva , Fatores de Tempo , Resultado do Tratamento
4.
Int J Cardiol ; 245: 168-173, 2017 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-28874289

RESUMO

INTRODUCTION: Atrioventricular node (AVN) ablation is usually a simple procedure but may sometimes be challenging. We aimed at identifying pre-procedural clinical predictors of challenging AVN ablation. METHODS: Patients referred for AVN ablation from 2009 to 2015 were retrospectively included. Baseline clinical data, procedural variables and outcomes of AVN ablation were collected. A "challenging procedure" was defined 1) total radiofrequency delivery to get persistent AVN block≥400s, 2) need for left-sided arterial approach or 3) failure to obtain AVN ablation. RESULTS: 200 patients were included (71±10years). A total of 37 (18.5%) patients had "challenging" procedures (including 9 failures, 4.5%), while 163 (81.5%) had "non-challenging" ablations. In multivariable analysis, male sex (Odds ratio (OR)=4.66, 95% confidence interval (CI): 1.74-12.46), body mass index (BMI, OR=1.08 per 1kg/m2, 95%CI 1.01-1.16), operator experience (OR=0.40, 95%CI 0.17-0.94), and moderate-to-severe tricuspid regurgitation (TR, OR=3.65, 95%CI 1.63-8.15) were significant predictors of "challenging" ablations. The proportion as a function of number of predictors was analyzed (from 0 to 4, including male sex, operator inexperience, a BMI>23.5kg/m2 and moderate-to-severe TR). There was a gradual increase in the risk of "challenging" procedure with the number of predictors by patient (No predictor: 0%; 1 predictor: 6.3%; 2 predictors: 16.5%; 3 predictors: 32.5%; 4 predictors: 77.8%). CONCLUSIONS: Operator experience, male sex, higher BMI and the degree of TR were independent predictors of "challenging" AVN ablation procedure. The risk increases with the number of predictors by patient.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Nó Atrioventricular/cirurgia , Índice de Massa Corporal , Ablação por Cateter/métodos , Frequência Cardíaca/fisiologia , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Estudos de Coortes , Feminino , Humanos , Complicações Intraoperatórias/diagnóstico , Complicações Intraoperatórias/fisiopatologia , Complicações Intraoperatórias/prevenção & controle , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA