Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Arrhythm ; 37(2): 338-347, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33850575

RESUMO

BACKGROUND: Substrate analysis of the left atrium in patients undergoing atrial fibrillation ablation has limitations when performed by means of simple bipolar acquisition. OBJECTIVE: To evaluate the incidence of low-voltage zones (LVZs) through maps constructed by means of various catheters: multipolar (MC), omnipolar (OC), and circular catheters (CMCs) with the 3D electro-anatomical systems (3d-S) CARTO3 and EnSite Precision. METHODS: To assess LVZs, we acquired maps by means of CMC and MC in the voltage range 0.05-0.5 mV in 70 consecutive patients in sinus rhythm. In the case of OC only, we made an intra-patient comparison of bipolar maps constructed by means of the along and across, and HD-Wave configurations of the EnSite 3d-S in the ranges of 0.05-0.5 and 0.5-1.0 mV. On the basis of this comparison, we chose the range that best identified LVZs as a set of different colors (SDC) compatible with patchy fibrosis (qualitative analysis). Subsequently, we detected the voltage values corresponding to purple and gray points, close to SDC, and the value inside corresponding to blue, green, and red colors, and we evaluated the color change in other voltage ranges. Finally, we performed a quantitative analysis of LVZs by applying the qualitative characteristics described above. RESULTS: On the basis of our settings, for OC, the optimal range identifying LVZs was 0.3-0.6 mV. OC revealed smaller LVZs than MC (P < .05 or P < .001), except in the lateral wall. No significant differences were observed between CMCs. CONCLUSIONS: In our experience, OC does not present the limits of bipolar HD maps, though further studies are needed in order to confirm that 0.3-0.6 mV is the optimal voltage range within which to identify LVZs.

2.
Ann Noninvasive Electrocardiol ; 24(1): e12547, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-29673010

RESUMO

We present the case of a spontaneously aborted sudden cardiac death related to an high-rate ventricular tachycardia in an healthy man with bileaflet mitral valve prolapse. An effective treatment of the patient, with complete suppression of ventricular ectopic activity, was achieved only combining medical therapy, ICD and catheter ablation, thus overcoming the limitations of each approach.


Assuntos
Ablação por Cateter/métodos , Morte Súbita Cardíaca/prevenção & controle , Eletrocardiografia/métodos , Prolapso da Valva Mitral/diagnóstico por imagem , Fibrilação Ventricular/diagnóstico por imagem , Fibrilação Ventricular/cirurgia , Terapia Combinada , Desfibriladores Implantáveis , Serviços Médicos de Emergência , Seguimentos , Humanos , Unidades de Terapia Intensiva , Masculino , Pessoa de Meia-Idade , Prolapso da Valva Mitral/complicações , Admissão do Paciente , Medição de Risco , Síncope/diagnóstico , Síncope/etiologia , Resultado do Tratamento , Fibrilação Ventricular/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...