1.
Anal Chem ; 83(22): 8439-47, 2011 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-21932784

RESUMO

The feasibility of implementing pyrosequencing chemistry within droplets using electrowetting-based digital microfluidics is reported. An array of electrodes patterned on a printed-circuit board was used to control the formation, transportation, merging, mixing, and splitting of submicroliter-sized droplets contained within an oil-filled chamber. A three-enzyme pyrosequencing protocol was implemented in which individual droplets contained enzymes, deoxyribonucleotide triphosphates (dNTPs), and DNA templates. The DNA templates were anchored to magnetic beads which enabled them to be thoroughly washed between nucleotide additions. Reagents and protocols were optimized to maximize signal over background, linearity of response, cycle efficiency, and wash efficiency. As an initial demonstration of feasibility, a portion of a 229 bp Candida parapsilosis template was sequenced using both a de novo protocol and a resequencing protocol. The resequencing protocol generated over 60 bp of sequence with 100% sequence accuracy based on raw pyrogram levels. Excellent linearity was observed for all of the homopolymers (two, three, or four nucleotides) contained in the C. parapsilosis sequence. With improvements in microfluidic design it is expected that longer reads, higher throughput, and improved process integration (i.e., "sample-to-sequence" capability) could eventually be achieved using this low-cost platform.


Assuntos
DNA Fúngico/análise , DNA Fúngico/genética , Técnicas Analíticas Microfluídicas/métodos , Análise de Sequência de DNA/métodos , Sequência de Bases , Candida/genética , Desoxirribonucleotídeos/análise , Desoxirribonucleotídeos/genética , Desoxirribonucleotídeos/metabolismo , Eletrodos , Enzimas/química , Enzimas/metabolismo , Técnicas Analíticas Microfluídicas/instrumentação , Análise de Sequência de DNA/instrumentação , Moldes Genéticos
2.
Clin Chem ; 57(10): 1444-51, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21859904

RESUMO

BACKGROUND: Newborn screening for lysosomal storage diseases (LSDs) has been gaining considerable interest owing to the availability of enzyme replacement therapies. We present a digital microfluidic platform to perform rapid, multiplexed enzymatic analysis of acid α-glucosidase (GAA) and acid α-galactosidase to screen for Pompe and Fabry disorders. The results were compared with those obtained using standard fluorometric methods. METHODS: We performed bench-based, fluorometric enzymatic analysis on 60 deidentified newborn dried blood spots (DBSs), plus 10 Pompe-affected and 11 Fabry-affected samples, at Duke Biochemical Genetics Laboratory using a 3-mm punch for each assay and an incubation time of 20 h. We used a digital microfluidic platform to automate fluorometric enzymatic assays at Advanced Liquid Logic Inc. using extract from a single punch for both assays, with an incubation time of 6 h. Assays were also performed with an incubation time of 1 h. RESULTS: Assay results were generally comparable, although mean enzymatic activity for GAA using microfluidics was approximately 3 times higher than that obtained using bench-based methods, which could be attributed to higher substrate concentration. Clear separation was observed between the normal and affected samples at both 6- and 1-h incubation times using digital microfluidics. CONCLUSIONS: A digital microfluidic platform compared favorably with a clinical reference laboratory to perform enzymatic analysis in DBSs for Pompe and Fabry disorders. This platform presents a new technology for a newborn screening laboratory to screen LSDs by fully automating all the liquid-handling operations in an inexpensive system, providing rapid results.


Assuntos
Ensaios Enzimáticos Clínicos/instrumentação , Doença de Fabry/diagnóstico , Doença de Depósito de Glicogênio Tipo II/diagnóstico , Dispositivos Lab-On-A-Chip , Técnicas Analíticas Microfluídicas/instrumentação , alfa-Galactosidase/sangue , alfa-Glucosidases/sangue , Fluorometria , Humanos , Recém-Nascido , Triagem Neonatal
3.
Expert Rev Mol Diagn ; 11(4): 393-407, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21545257

RESUMO

Digital microfluidics based on electrowetting is a type of microfluidic platform in which liquids are processed as individual unit-sized droplets that are dispensed from a source, merged together, split apart or transported between locations on demand. These devices are implemented using arrays of surface electrodes to control the shape and position of droplets through the electrowetting effect. A major thrust of digital microfluidics research has been the development of integrated lab-on-a-chip devices to perform clinical in vitro diagnostic assays. A variety of preparatory and analytical processes have been implemented and feasibility has been demonstrated for test types ranging from clinical chemistries to immunoassays, nucleic acid tests and cell-based assays. In this article, the current state and future potential of digital microfluidics for clinical diagnostic testing is reviewed and evaluated.


Assuntos
Técnicas de Laboratório Clínico , Eletroumectação , Técnicas Analíticas Microfluídicas , Humanos , Manejo de Espécimes/métodos
4.
Diagn Microbiol Infect Dis ; 67(1): 22-9, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20227222

RESUMO

Rapid, accurate diagnosis of community-acquired pneumonia (CAP) due to Mycoplasma pneumoniae is compromised by low sensitivity of culture and serology. Polymerase chain reaction (PCR) has emerged as a sensitive method to detect M. pneumoniae DNA in clinical specimens. However, conventional real-time PCR is not cost-effective for routine or outpatient implementation. Here, we evaluate a novel microfluidic real-time PCR platform (Advanced Liquid Logic, Research Triangle Park, NC) that is rapid, portable, and fully automated. We enrolled patients with CAP and extracted DNA from nasopharyngeal wash (NPW) specimens using a biotinylated capture probe and streptavidin-coupled magnetic beads. Each extract was tested for M. pneumoniae-specific DNA by real-time PCR on both conventional and microfluidic platforms using Taqman probe and primers. Three of 59 (5.0%) NPWs were positive, and agreement between the methods was 98%. The microfluidic platform was equally sensitive but 3 times faster and offers an inexpensive and convenient diagnostic test for microbial DNA.


Assuntos
Técnicas Bacteriológicas/métodos , Microfluídica/métodos , Técnicas de Diagnóstico Molecular/métodos , Mycoplasma pneumoniae/isolamento & purificação , Pneumonia por Mycoplasma/diagnóstico , Reação em Cadeia da Polimerase/métodos , Automação , Infecções Comunitárias Adquiridas/microbiologia , Humanos , Mycoplasma pneumoniae/genética , Nasofaringe/microbiologia , Pneumonia por Mycoplasma/microbiologia , Sistemas Automatizados de Assistência Junto ao Leito , Sensibilidade e Especificidade , Fatores de Tempo
5.
Anal Chem ; 82(6): 2310-6, 2010 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-20151681

RESUMO

This paper details the development of a digital microfluidic platform for multiplexed real-time polymerase chain reactions (PCR). Liquid samples in discrete droplet format are programmably manipulated upon an electrode array by the use of electrowetting. Rapid PCR thermocycling is performed in a closed-loop flow-through format where for each cycle the reaction droplets are cyclically transported between different temperature zones within an oil-filled cartridge. The cartridge is fabricated using low-cost printed-circuit-board technology and is intended to be a single-use disposable device. The PCR system exhibited remarkable amplification efficiency of 94.7%. To test its potential application in infectious diseases, this novel PCR system reliably detected diagnostic DNA levels of methicillin-resistant Staphylococcus aureus (MRSA), Mycoplasma pneumoniae , and Candida albicans . Amplification of genomic DNA samples was consistently repeatable across multiple PCR loops both within and between cartridges. In addition, simultaneous real-time PCR amplification of both multiple different samples and multiple different targets on a single cartridge was demonstrated. A novel method of PCR speed optimization using variable cycle times has also been proposed and proven feasible. The versatile system includes magnetic bead handling capability, which was applied to the analysis of simulated clinical samples that were prepared from whole blood using a magnetic bead capture protocol. Other salient features of this versatile digital microfluidic PCR system are also discussed, including the configurability and scalability of microfluidic operations, instrument portability, and substrate-level integration with other pre- and post-PCR processes.


Assuntos
DNA Bacteriano/análise , DNA Fúngico/análise , Staphylococcus aureus Resistente à Meticilina/genética , Microfluídica/instrumentação , Reação em Cadeia da Polimerase/instrumentação , Candida albicans/genética , DNA Bacteriano/genética , DNA Fúngico/genética , Desenho de Equipamento , Mycoplasma pneumoniae/genética
6.
Lab Chip ; 8(12): 2188-96, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19023486

RESUMO

A digital microfluidic platform for performing heterogeneous sandwich immunoassays based on efficient handling of magnetic beads is presented in this paper. This approach is based on manipulation of discrete droplets of samples and reagents using electrowetting without the need for channels where the droplets are free to move laterally. Droplet-based manipulation of magnetic beads therefore does not suffer from clogging of channels. Immunoassays on a digital microfluidic platform require the following basic operations: bead attraction, bead washing, bead retention, and bead resuspension. Several parameters such as magnetic field strength, pull force, position, and buffer composition were studied for effective bead operations. Dilution-based washing of magnetic beads was demonstrated by immobilizing the magnetic beads using a permanent magnet and splitting the excess supernatant using electrowetting. Almost 100% bead retention was achieved after 7776-fold dilution-based washing of the supernatant. Efficient resuspension of magnetic beads was achieved by transporting a droplet with magnetic beads across five electrodes on the platform and exploiting the flow patterns within the droplet to resuspend the beads. All the magnetic-bead droplet operations were integrated together to generate standard curves for sandwich heterogeneous immunoassays on human insulin and interleukin-6 (IL-6) with a total time to result of 7 min for each assay.


Assuntos
Imunoensaio , Magnetismo , Microfluídica/instrumentação , Microfluídica/métodos , Humanos , Imunoensaio/métodos , Insulina/química , Interleucina-6/química , Magnetismo/instrumentação
7.
Lab Chip ; 3(1): 28-33, 2003 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15100802

RESUMO

Mixing of analytes and reagents is a critical step in realizing a lab-on-a-chip. However, mixing of liquids is very difficult in continuous flow microfluidics due to laminar flow conditions. An alternative mixing strategy is presented based on the discretization of liquids into droplets and further manipulation of those droplets by electrowetting. The interfacial tensions of the droplets are controlled with the application of voltage. The droplets act as virtual mixing chambers, and mixing occurs by transporting the droplet across an electrode array. We also present an improved method for visualization of mixing where the top and side views of mixing are simultaneously observed. Microliters of liquid droplets are mixed in less than five seconds, which is an order of magnitude improvement in reported mixing times of droplets. Flow reversibility hinders the process of mixing during linear droplet motion. This mixing process is not physically confined and can be dynamically reconfigured to any location on the chip to improve the throughput of the lab-on-a-chip.


Assuntos
Microquímica , Microfluídica , Eletroquímica/instrumentação , Eletrodos , Desenho de Equipamento , Indicadores e Reagentes/química , Microquímica/instrumentação , Microquímica/métodos , Microfluídica/instrumentação , Microfluídica/métodos , Tensão Superficial , Molhabilidade
SELEÇÃO DE REFERÊNCIAS