1.
J Appl Clin Med Phys ; 23(6): e13640, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35536772

RESUMO

Plan checks are important components of a robust quality assurance (QA) program. Recently, the American Association of Physicists in Medicine (AAPM) published two reports concerning plan and chart checking, Task Group (TG) 275 and Medical Physics Practice Guideline (MPPG) 11.A. The purpose of the current study was to crosswalk initial plan check failure modes revealed in TG 275 against our institutional QA program and local incident reporting data. Ten physicists reviewed 46 high-risk failure modes reported in Table S1.A.i of the TG 275 report. The committee identified steps in our planning process which sufficiently checked each failure mode. Failure modes that were not covered were noted for follow-up. A multidisciplinary committee reviewed the narratives of 1599 locally-reported incidents in our Radiation Oncology Incident Learning System (ROILS) database and categorized each into the high-risk TG 275 failure modes. We found that over half of the 46 high-risk failure modes, six of which were top-ten failure modes, were covered in part by daily contouring peer-review rounds, upstream of the traditional initial plan check. Five failure modes were not adequately covered, three of which concerned pregnancy, pacemakers, and prior dose. Of the 1599 incidents analyzed, 710 were germane to the initial plan check, 23.4% of which concerned missing pregnancy attestations. Most, however, were caught prior to CT simulation (98.8%). Physics review and initial plan check were the least efficacious checks, with error detection rates of 31.8% and 31.3%, respectively, for some failure modes. Our QA process that includes daily contouring rounds resulted in increased upstream error detection. This work has led to several initiatives in the department, including increased automation and enhancement of several policies and procedures. With TG 275 and MPPG 11.A as a guide, we strongly recommend that departments consider an internal chart checking policy and procedure review.


Assuntos
Radioterapia (Especialidade) , Planejamento da Radioterapia Assistida por Computador , Automação , Humanos , Física , Planejamento da Radioterapia Assistida por Computador/métodos , Gestão de Riscos/métodos
2.
Int J Radiat Oncol Biol Phys ; 88(1): 204-9, 2014 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-24210671

RESUMO

PURPOSE: To prospectively evaluate a 2-dimensional transit dosimetry algorithm's performance on a patient population and to analyze the issues that would arise in a widespread clinical adoption of transit electronic portal imaging device (EPID) dosimetry. METHODS AND MATERIALS: Eleven patients were enrolled on the protocol; 9 completed and were analyzed. Pretreatment intensity modulated radiation therapy (IMRT) patient-specific quality assurance was performed using a stringent local 3%, 3-mm γ criterion to verify that the planned fluence had been appropriately transferred to and delivered by the linear accelerator. Transit dosimetric EPID images were then acquired during treatment and compared offline with predicted transit images using a global 5%, 3-mm γ criterion. RESULTS: There were 288 transit images analyzed. The overall γ pass rate was 89.1%±9.8% (average±1 SD). For the subset of images for which the linear accelerator couch did not interfere with the measurement, the γ pass rate was 95.7%±2.4%. A case study is presented in which the transit dosimetry algorithm was able to identify that a lung patient's bilateral pleural effusion had resolved in the time between the planning CT scan and the treatment. CONCLUSIONS: The EPID transit dosimetry algorithm under consideration, previously described and verified in a phantom study, is feasible for use in treatment delivery verification for real patients. Two-dimensional EPID transit dosimetry can play an important role in indicating when a treatment delivery is inconsistent with the original plan.


Assuntos
Algoritmos , Erros Médicos/prevenção & controle , Neoplasias/radioterapia , Aceleradores de Partículas/instrumentação , Garantia da Qualidade dos Cuidados de Saúde/métodos , Radiometria/instrumentação , Planejamento da Radioterapia Assistida por Computador/normas , Radioterapia de Intensidade Modulada/normas , Neoplasias Encefálicas/radioterapia , Estudos de Viabilidade , Humanos , Neoplasias Pulmonares/radioterapia , Masculino , Derrame Pleural/diagnóstico por imagem , Estudos Prospectivos , Neoplasias da Próstata/radioterapia , Garantia da Qualidade dos Cuidados de Saúde/normas , Radiografia , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos
3.
Med Phys ; 39(1): 87-98, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22225278

RESUMO

PURPOSE: A method to perform transit dosimetry with an electronic portal imaging device (EPID) by extending the commercial implementation of a published through-air portal dose image (PDI) prediction algorithm Van Esch et al. [Radiother. Oncol. 71, 223-234 (2004)] is proposed and validated. A detailed characterization of the attenuation, scattering, and EPID response behind objects in the beam path is used to convert through-air PDIs into transit PDIs. METHODS: The EPID detector response beyond a range of water equivalent thicknesses (0-35 cm) and field sizes (3×3 to 22.2×29.6 cm(2)) was analyzed. A constant air gap between the phantom exit surface and the EPID was utilized. A model was constructed that accounts for the beam's attenuation along the central axis, the presence of phantom scattered radiation, the detector's energy dependent response, and the difference in EPID off-axis pixel response relative to the central pixel. The efficacy of the algorithm was verified by comparing predicted and measured PDIs for IMRT fields delivered through phantoms of increasing complexity. RESULTS: The expression that converts a through-air PDI to a transit PDI is dependent on the object's thickness, the irradiated field size, and the EPID pixel position. Monte Carlo derived narrow-beam linear attenuation coefficients are used to model the decrease in primary fluence incident upon the EPID due to the object's presence in the beam. This term is multiplied by a factor that accounts for the broad beam scatter geometry of the linac-phantom-EPID system and the detector's response to the incident beam quality. A 2D Gaussian function that models the nonuniformity of pixel response across the EPID detector plane is developed. For algorithmic verification, 49 IMRT fields were repeatedly delivered to homogeneous slab phantoms in 5 cm increments. Over the entire set of measurements, the average area passing a 3%∕3mm gamma criteria slowly decreased from 98% for no material in the beam to 96.7% for 35 cm of material in the beam. The same 49 fields were delivered to a heterogeneous slab phantom and on average, 97.1% of the pixels passed the gamma criteria. Finally, a total of 33 IMRT fields were delivered to the anthropomorphic phantom and on average, 98.1% of the pixels passed. The likelihood of good matches was independent of anatomical site. CONCLUSIONS: A prediction of the transit PDI behind a phantom or patient can be created for the purposes of treatment verification via an extension of the Van Esch through-air PDI algorithm. The results of the verification measurements through phantoms indicate that further investigation through patients during their treatments is warranted.


Assuntos
Algoritmos , Radiometria/instrumentação , Radiometria/métodos , Radioterapia Conformacional/instrumentação , Radioterapia Conformacional/métodos , Ecrans Intensificadores para Raios X , Ar , Desenho de Equipamento , Análise de Falha de Equipamento , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Med Phys ; 37(6): 2425-34, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20632552

RESUMO

PURPOSE: Portal dose images acquired with an amorphous silicon electronic portal imaging device (EPID) suffer from artifacts related to backscattered radiation. The backscatter signal varies as a function of field size (FS) and location on the EPID. Most current portal dosimetry algorithms fail to account for the FS dependence. The ramifications of this omission are investigated and solutions for correcting the measured dose images for FS specific backscatter are proposed. METHODS: A series of open field dose images were obtained for field sizes ranging from 2 x 2 to 30 x 40 cm2. Each image was analyzed to determine the amount of backscatter present. Two methods to account for the relationship between FS and backscatter are offered. These include the use of discrete FS specific correction matrices and the use of a single generalized equation. The efficacy of each approach was tested on the clinical dosimetric images for ten patients, 49 treatment fields. The fields were evaluated to determine whether there was an improvement in the dosimetric result over the commercial vendor's current algorithm. RESULTS: It was found that backscatter manifests itself as an asymmetry in the measured signal primarily in the inplane direction. The maximum error is approximately 3.6% for 10 x 10 and 12.5 x 12.5 cm2 field sizes. The asymmetry decreased with increasing FS to approximately 0.6% for fields larger than 30 x 30 cm2. The dosimetric comparison between the measured and predicted dose images was significantly improved (p << .001) when a FS specific backscatter correction was applied. The average percentage of points passing a 2%, 2 mm gamma criteria increased from 90.6% to between 96.7% and 97.2% after the proposed methods were employed. CONCLUSIONS: The error observed in a measured portal dose image depends on how much its FS differs from the 30 x 40 cm2 calibration conditions. The proposed methods for correcting for FS specific backscatter effectively improved the ability of the EPID to perform dosimetric measurements. Correcting for FS specific backscatter is important for accurate EPID dosimetry and can be carried out using the methods presented within this investigation.


Assuntos
Algoritmos , Artefatos , Radiometria/instrumentação , Radioterapia Conformacional/instrumentação , Ecrans Intensificadores para Raios X , Desenho de Equipamento , Análise de Falha de Equipamento , Radiometria/métodos , Dosagem Radioterapêutica , Radioterapia Conformacional/métodos , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade