Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Life (Basel) ; 14(4)2024 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-38672802

RESUMO

BACKGROUND AND OBJECTIVES: Diminutive polyps present a unique challenge in colorectal cancer (CRC) prevention strategies. This study aims to assess the characteristics and variables of diminutive polyps in a Romanian cohort, intending to develop a combined resect-and-retrieve or resect-and-discard strategy that reduces the need for an optical diagnosis. MATERIALS AND METHODS: A prospective cohort study was conducted at two endoscopy centers in Romania from July to December 2021. Adult patients undergoing colonoscopies where polyps were identified and resected were included. Endoscopic procedures employed advanced diagnostic features, including blue-light imaging (BLI) and narrow-band imaging (NBI). Logistic regression analysis was utilized to determine factors impacting the probability of adenomatous polyps with high-grade dysplasia (HGD). RESULTS: A total of 427 patients were included, with a mean age of 59.42 years (±11.19), predominantly male (60.2%). The most common indication for a colonoscopy was lower gastrointestinal symptoms (42.6%), followed by screening (28.8%). Adequate bowel preparation was achieved in 87.8% of cases. The logistic regression analysis revealed significant predictors of HGD in adenomatous polyps: age (OR = 1.05, 95% CI: 1.01-1.08, p = 0.01) and polyp size (>5 mm vs. ≤5 mm, OR = 4.4, 95% CI: 1.94-10.06, p < 0.001). Polyps classified as Paris IIa, Ip, and Isp were significantly more likely to harbor HGD compared to the reference group (Is), with odds ratios of 6.05, 3.68, and 2.7, respectively. CONCLUSIONS: The study elucidates significant associations between the presence of HGD in adenomatous polyps and factors such as age, polyp size, and Paris classification. These findings support the feasibility of a tailored approach in the resect-and-discard and resect-and-retrieve strategies for diminutive polyps, potentially optimizing CRC prevention and intervention practices. Further research is warranted to validate these strategies in broader clinical settings.

2.
Diagnostics (Basel) ; 14(3)2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38337862

RESUMO

Laparoscopic cholecystectomy (LC) is the gold standard treatment in acute cholecystitis. However, one in six cases is expected to be difficult due to intense inflammation and suspected adherence to and involvement of adjacent important structures, which may predispose patients to higher risk of vascular and biliary injuries. In this study, we aimed to identify the preoperative parameters with predictive value for surgical difficulties. A retrospective study of 255 patients with acute cholecystitis admitted in emergency was performed between 2019 and 2023. Patients in the difficult laparoscopic cholecystectomy (DLC) group experienced more complications compared to the normal LC group (33.3% vs. 15.3%, p < 0.001). Age (p = 0.009), male sex (p = 0.03), diabetes (p = 0.02), delayed presentation (p = 0.03), fever (p = 0.004), and a positive Murphy sign (p = 0.007) were more frequently encountered in the DLC group. Total leukocytes, neutrophils, and the neutrophil-to-lymphocyte ratio (NLR) were significantly higher in the DLC group (p < 0.001, p = 0.001, p = 0.001 respectively). The Tongyoo score (AUC ROC of 0.856) and a multivariate model based on serum fibrinogen, thickness of the gallbladder wall, and transverse diameter of the gallbladder (AUC ROC of 0.802) showed a superior predictive power when compared to independent parameters. The predictive factors for DLC should be assessed preoperatively to optimize the therapeutic decision.

3.
Diagnostics (Basel) ; 13(17)2023 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-37685341

RESUMO

Vibration-controlled transient elastography (VCTE) was the first non-invasive method used for assessing liver fibrosis in patients with chronic liver disease. Over the years, many studies have evaluated its performance. It is now used globally, and, in some countries, it represents the primary step in evaluating liver fibrosis. The aim of this study is to assess the feasibility of VCTE and highlight the prevalence of liver fibrosis stages assessed by VCTE in a large cohort of patients at a single study center. We also aimed to observe the trends in liver stiffness (LS) values over the years according to each type of hepatopathy. A retrospective study was conducted over a period of 13 years (2007-2019) and included patients who presented to our clinic for LS measurements (LSMs), either with known liver diseases or with suspected liver pathology who were undergoing fibrosis screening. The database contained a total of 23,420 measurements. Valid LSMs were obtained in 90.91% (21,291/23,420) of the cases, while 2129 (9.09%) of the measurements were either failed or unreliable. In untreated patients with chronic viral hepatitis, LS values tended to increase during the years, while in patients undergoing antiviral therapy LS values significantly decreased. Our comprehensive study, one of the largest of its kind spanning 13 years, emphasizes the reliability and significance of VCTE in real-world clinical settings.

4.
J Clin Med ; 12(17)2023 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-37685663

RESUMO

Cystic echinococcosis is an often-overlooked condition that otherwise negatively impacts both the individual and the community, prompting major public health concerns. Early diagnosis and treatment, as well as collaboration between specialties including surgery and parasitology, are essential for avoiding complications and disease relapse. To better illustrate this, we present the case of an elderly person with a rare localization of the disease at the muscular level. The patient underwent numerous surgical interventions, and received multiple courses of antiparasitic treatment over the course of 40 years as a result of the multivisceral dissemination of the parasite.

5.
Int J Mol Sci ; 24(12)2023 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-37373501

RESUMO

The ordered mesoporous silica MCM-48 with cubic Ia3d structure was synthesized using the cationic surfactant hexadecyltrimethylammonium bromide (CTAB) as a template agent and tetraethylorthosilicate (TEOS) as a silica source. The obtained material was first functionalized with (3-glycidyloxypropyl)trimethoxysilane (KH560); further, two types of amination reagents were used: ethylene diamine (N2) and diethylene triamine (N3). The modified amino-functionalized materials were characterized by powder X-ray diffraction (XRD) at low angles, infrared spectroscopy (FT-IR) and nitrogen adsorption-desorption experiments at 77 K. Characterization from a structural point of view reveals that the ordered MCM-48 mesoporous silica has a highly ordered structure and a large surface area (1466.059 m2/g) and pore volume (0.802 cm3/g). The amino-functionalized MCM-48 molecular sieves were tested for CO2 adsorption-desorption properties at different temperatures using thermal program desorption (TPD). Promising results for CO2 adsorption capacities were achieved for MCM-48 sil KH560-N3 at 30 °C. At 30 °C, the MCM-48 sil KH560-N3 sample has an adsorption capacity of 3.17 mmol CO2/g SiO2, and an efficiency of amino groups of 0.58 mmol CO2/mmolNH2. After nine adsorption-desorption cycles, the results suggest that the performance of the MCM-48 sil KH N2 and MCM-48 sil KH N3 adsorbents is relatively stable, presenting a low decrease in the adsorption capacity. The results reported in this paper for the investigated amino-functionalized molecular sieves as absorbents for CO2 can be considered as promising.


Assuntos
Dióxido de Carbono , Dióxido de Silício , Dióxido de Silício/química , Dióxido de Carbono/química , Espectroscopia de Infravermelho com Transformada de Fourier , Cetrimônio , Adsorção
6.
Obesity (Silver Spring) ; 31(7): 1755-1766, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37245331

RESUMO

OBJECTIVE: Although intake of specific macronutrients has been associated with sleep parameters, interventional evidence is lacking. Therefore, this randomized trial was conducted to examine how a more unhealthy high-fat/high-sugar (HFHS) diet impacts sleep in humans. METHODS: In a crossover study, 15 healthy young men consumed two isocaloric diets in random order for a week: an HFHS and a low-fat/low-sugar diet. Following each diet, in-lab sleep was recorded using polysomnography during a full night of sleep and during recovery sleep after extended wakefulness. Sleep duration, macrostructure, and microstructure (oscillatory pattern and slow waves) were investigated using machine learning-based algorithms. RESULTS: Sleep duration did not differ across the diets based on actigraphy and the in-lab polysomnography. Sleep macrostructure was similar after 1 week on each diet. Compared with the low-fat/low-sugar diet, consumption of the HFHS diet resulted in reduced delta power, delta to beta ratio, and slow wave amplitude but increased alpha and theta power during deep sleep. During recovery sleep, similar sleep oscillatory changes were observed. CONCLUSIONS: Short-term consumption of a more unhealthy diet alters sleep oscillatory features that regulate the restorative properties of sleep. Whether such changes can mediate adverse health outcomes associated with consumption of an unhealthier diet warrants investigation.


Assuntos
Dieta com Restrição de Gorduras , Sono , Masculino , Humanos , Estudos Cross-Over , Polissonografia , Açúcares
7.
Materials (Basel) ; 16(7)2023 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-37049135

RESUMO

Adsorption recovery of precious metals on a variety of solid substrates has steadily gained increased attention in recent years. Special attention was paid to the studies on the characterization of the adsorptive properties of materials with a high affinity for gold depending on the nature of the pendant groups present in the structure of the material. The aim of the present work was to synthesize and characterize a new material by using the sol-gel synthesis method (designated as BCb/CB). In this case, synthesis involved the following precursors: bismuth carbonate (III), carbon black, and IGEPAL surfactant (octylphenoxypolyethoxyethanol). Immobilization of the heterojunction as bismuth oxide over a flexible support such as carbon black (CB) can prevent their elution in solution and make it versatile for its use in a system. In this work, a new adsorbent material based on bismuth carbonate supported over carbon black (BCb/CB) was developed and used further for gold recovery from aqueous solutions. The required material was characterized physically/chemically by scanning electron microscopy (SEM); energy dispersive X-ray spectrometry (EDX); X-ray diffraction (XRD); thermal analysis (DTG/DTA); atomic force microscopy (AFM). The Brunauer-Emmett-Teller (BET) method was used to determine the specific surface area indicating a value of approximately 40 m2/g, higher than the surface of CB precursor (36 m2/g). The adsorptive properties and the adsorption mechanism of the materials were highlighted in order to recover Au(III). For this, static adsorption studies were carried out. The parameters that influence the adsorption process were studied, namely: the pH, the contact time, the temperature, and the initial concentration of the gold ions in the used solution. In order to establish the mechanism of the adsorption process, kinetic, thermodynamic, and equilibrium studies were carried out. Experimental data proved that the gold recovery can be conducted with maximum performance at pH 3, at room temperature. Thermodynamic studies proved that the gold adsorption on BCb/CB material is a spontaneous and endothermal process. The results indicate a total adsorption capacity of 13.1 mg Au(III)/g material. By using this material in real solutions, a recovery efficiency of 90.5% was obtained, concomitant with a higher selectivity (around 95%).

8.
Diagnostics (Basel) ; 13(7)2023 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-37046471

RESUMO

Various statistical models predict the probability of developing hepatocellular carcinoma (HCC) in patients with cirrhosis, with GALAD being one of the most extensively studied scores. Biomarkers like alpha-fetoprotein (AFP), AFP-L3, and des-g-carboxyprothrombin (DCP) are widely used alone or in conjunction with ultrasound to screen for HCC. Our study aimed to compare the effectiveness of Cytokeratin 19 (CK19) and Glypican-3 (GPC3) as standalone biomarkers and in a statistical model to predict the likelihood of HCC. We conducted a monocentric prospective study involving 154 participants with previously diagnosed liver cirrhosis, divided into two groups: 95 patients with confirmed HCC based on clinical, biological, and imaging features and 59 patients without HCC. We measured the levels of AFP, AFP-L3, DCP, GPC3, and CK19 in both groups. We used univariate and multivariate statistical analyses to evaluate the ability of GPC3 and CK19 to predict the presence of HCC and incorporated them into a statistical model-the GALKA score-which was then compared to the GALAD score. AFP performed better than AFP-F3, DCP, GPC3, and CK19 in predicting the presence of HCC in our cohort. Additionally, GPC3 outperformed CK19. We used multivariate analysis to compute the GALKA score to predict the presence of HCC. Using these predictors, the following score was formulated: 0.005*AFP-L3 + 0.00069*AFP + 0.000066*GPC3 + 0.01*CK19 + 0.235*Serum Albumin-0.277. The optimal cutoff was >0.32 (AUROC = 0.98, sensitivity: 96.8%, specificity: 93%, positive predictive value-95.8%, negative predictive value-94.8%). The GALKA score had a similar predictive value to the GALAD score for the presence of HCC. In conclusion, AFP, AFP-L3, and DCP were the best biomarkers for predicting the likelihood of HCC. Our score performed well overall and was comparable to the GALAD score.

9.
Biomedicines ; 11(3)2023 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-36979917

RESUMO

The estimation of viscosity by measuring the shear-wave dispersion (SWD) using ultrasound 2D shear-wave elastography (SWE) is becoming more and more popular. Recent research suggests that SWD can be used in addition to 2D-SWE (shear-wave speed) to diagnose diffuse liver disease. Viscosity was studied for the assessment of normal thyroid tissue. This study aims to evaluate the use of viscosity measurements in patients with chronic autoimmune thyroiditis using the SuperSonic MACH®30 ultrasound machine (Hologic SuperSonic Imagine, Aix-en-Provence, France) which provides the Vi PLUS mode for viscosity and the 2D SWE PLUS mode for shear-wave speed measurements. Valid measurements were obtained in 308 cases, 153 with chronic autoimmune thyroiditis (CAT) and 155 with no thyroid pathology (95.95% feasibility of the methods). The differences between the healthy group and the CAT group were statistically significant both for Vi PLUS (2.5 ± 0.4 vs. 2.8 ± 0.5, p < 0.0001) and for 2D-SWE PLUS (13.5 ± 3.3 vs. 23.1 ± 8.3, p < 0.0001). The diagnostic performance was poor for Vi PLUS alone (AUC = 0.69; cut-off > 2.5 Pa·s, se = 68.6%; sp = 64.52%) and good for 2D-SWE PLUS alone (AUC = 0.861; cut-off > 18.4 kPa, se = 69.9%; sp = 92.2%). Vi PLUS correlated with 2D-SWE PLUS, with the presence of CAT, the thyroid volume, levothyroxine replacement therapy and age. Statistically significant differences were found between the CAT subgroup receiving thyroid replacement therapy and the subgroup without therapy: 24.74 ± 8.33 vs. 21.93 ± 8.12 kPa for 2D-SWE (p = 0.0380) and 3 ± 0.5 vs. 2.7 ± 0.4 Pa·s for Vi PLUS (p = 0.0193). Elastography-based methods improve the classic ultrasound evaluation: 2D-SWE PLUS performed somewhat better in distinguishing CAT from normal thyroid tissue, while Vi PLUS made a slightly better assessment regarding the functional status.

10.
Med Ultrason ; 24(4): 406-413, 2022 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-36546434

RESUMO

Non-invasive tests have been developed to determine the severity of liver disease in patients with alcohol use disorder (AUD). We aimed to assess the severity of liver steatosis and liver fibrosis (LF) in a cohort of patients with AUD using liver elastography and biological scores. MATERIALS AND METHODS: A prospective study was performed on 172 subjects, without previously known liver disease, with a positive AUDIT-C score, serum markers, and vibration-controlled transient elastography (VCTE) with Controlled Attenuation Parameter (CAP). RESULTS: From 172 subjects with positive AUDIT-C test, VCTE diagnosed advanced fibrosis (F3) in 13.9% (24/172) of the subjects and liver cirrhosis (F4) in 17.5% (30/172). Moderate and severe steatosis was found in 18.6% (32/172), respectively 52.3% (90/172). Significant correlations were found between liver stiffness and APRI (r=0.33, p=0.001), FIB-4(r=0.31, p=0.0012) and the age-platelet index (r=0.25, p=0.008). FIB-4 (p=0.01) and age-platelet index (p=0.03) were independently associated with the presence of advanced fibrosis. Age-platelet index (AUC- 0.82) performed significantly better than AST/ALT (AUC- 0.55) and APRI (AUC- 0.58) (p= 0.0001 and p= 0.0014, respectively), but no differences were found when compared to FIB-4 (AUC- 0.77) (p=0.35) for predicting advanced fibrosis. CONCLUSION: In conclusion, in a cohort of patients with AUD, 70.9% presented moderate and severe liver steatosis and 17.5% were newly diagnosed with liver cirrhosis.


Assuntos
Técnicas de Imagem por Elasticidade , Fígado Gorduroso , Hepatopatias Alcoólicas , Hepatopatia Gordurosa não Alcoólica , Humanos , Estudos Prospectivos , Aspartato Aminotransferases , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/complicações , Fígado/diagnóstico por imagem , Fibrose , Hepatopatias Alcoólicas/complicações , Hepatopatias Alcoólicas/patologia , Fígado Gorduroso/complicações , Biomarcadores , Biópsia , Hepatopatia Gordurosa não Alcoólica/complicações
11.
Biomedicines ; 10(11)2022 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-36359379

RESUMO

Introduction: There is currently a lack of published data on kidney elasticity and viscosity. Non-invasive techniques, such as two-dimensional shear-wave elastography (2D-SWE PLUS) and viscosity plane-wave ultrasound (Vi PLUS), have surfaced as new detection methods, which, thanks to efficient processing software, are expected to improve renal stiffness and viscosity measurements. This study aims to be the first one to assess the normal range values in normal renal function subjects and to investigate the factors that impact them. Methods: We conducted a cross-sectional study employing 50 participants (29 women and 21 men) with a mean age of 42.22 ± 13.17, a mean estimated glomerular filtration rate (eGFR) of 97.12 ± 11 mL/min/1.73 m2, a mean kidney length of 10.16 ± 0.66 cm, and a mean body mass index (BMI) of 24.24 ± 3.98. With a C6-1X convex transducer and the Ultra-FastTM software available on the Hologic Aixplorer Mach 30 ultrasound system, we acquired five measurements of renal cortical stiffness and viscosity (achieved from five distinct images in the middle part of the subcapsular cortex) from each kidney. The ten measurements' median values correlated with the participant's demographical, biological, and clinical parameters. Results: The mean kidney elasticity was 31.88 ± 2.89 kiloPascal (kPa), and the mean viscosity was 2.44 ± 0.57 Pascal.second (Pa.s) for a mean measurement depth 4.58 ± 1.02 cm. Renal stiffness seemed to be influenced by age (r = −0.7047, p < 0.0001), the measurement depth (r = −0.3776, p = 0.0075), and eGFR (r = 0.6101, p < 0.0001) but not by BMI (r = −0.2150, p = 0.1338), while viscosity appeared to be impacted by age (r = −0.4251, p = 0.0021), eGFR (r = 0.4057, p = 0.0038), the measurement depth (r = −0.4642, p = 0.0008), and BMI (r = −0.3676, p = 0.0086). The results of the one-way ANOVA used to test the differences in the variables among the three age sub-groups are statistically significant for both 2D-SWE PLUS (p < 0.001) and Vi PLUS (p = 0.015). The method found good intra-operator reproducibility for the 2D-SWE PLUS measurements, with an ICC of 0.8365 and a 95% CI of 0.7512 to 0.8990, and for the Vi PLUS measurements, with an ICC of 0.9 and a 95% CI of 0.8515 to 0.9397. Conclusions: Renal stiffness and viscosity screening may become an efficacious, low-cost way to gather supplemental diagnostic data from patients with chronic kidney disease (CKD). The findings demonstrate that these non-invasive methods are highly feasible and not influenced by gender and that their values correlate with renal function and decrease with age progression. Nevertheless, more research is required to ascertain their place in clinical practice.

12.
Diagnostics (Basel) ; 12(11)2022 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-36359490

RESUMO

This is a retrospective single-center study that included 87 subjects. All subjects had chronic hepatitis B or HBV cirrhosis and underwent nucleos(t)ide analogs (NUC) treatment for more than one year. The study aimed to evaluate the dynamic changes in liver stiffness (LS) measured by transient elastography (TE) during a median interval of 64 months. Patients were assessed prior to starting therapy and followed up annually. Liver stiffness measurements (LSM) were performed annually, and ten valid LSMs were obtained in each session. Reliable LSMs were defined as the median value of 10 measurements with Interquartile range/median (IQR/M) ≤ 30%. A significant decrease in liver stiffness values (p < 0.001) was observed during follow-up. In patients with liver cirrhosis, the LSMs decreased significantly after only one year, 24.6 ± 4.3 kPa vs. 13.5 ± 4.2 kPa (p = 0.007), whereas the decrease in non-cirrhotic patients was not significant, 7.31 ± 3.62 vs. 6.80 ± 2.41 (p = 0.27). Liver stiffness decrease was more significant in patients with initially higher transaminases. Undetectable viral load was achieved in 73.5% of patients in year one, 82.7% in year two, and 90.8% in year three of treatment. In conclusion, our study reveals a decrease in liver stiffness by TE in patients with chronic hepatitis B when undergoing anti-HBV therapy in the first two years. It can be used as a method for follow-up in patients undergoing NUC therapy.

13.
Diagnostics (Basel) ; 12(9)2022 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-36140595

RESUMO

Shear-wave elastography (SWE) is widely used in thyroid evaluation, but multiple factors influence thyroid stiffness. Estimating tissue viscosity may enhance the ultrasound diagnosis of thyroid diseases, along with the ultrasound (US) and the SWE assessment. In order to be able to detect diffuse thyroid disease by viscosity measurements, it is essential to firstly define the normal values of thyroid viscosity in healthy subjects. Currently there are no published data on thyroid viscosity measurements. This first prospective study aimed to determine the normal range of thyroid viscosity values in a cohort of healthy thyroids, as well as to determine the factors that may influence them. One hundred and twenty-one consecutive subjects without thyroid pathology were evaluated in the study by means of conventional ultrasound, two-dimensional SWE (2D SWE PLUS) and viscosity plane-wave ultrasound (ViPLUS) embedded in the Supersonic MACH® 30 ultrasound system. Five valid tissue viscosity measurements were obtained for each thyroid lobe in every patient and the median values were analyzed and correlated with the biological and demographic parameters of each patient. Our results reveal that ViPLUS is a highly feasible and reproducible technique for thyroid evaluation. Thyroid stiffness, age, gender, BMI and depth of measurements did not influence the thyroid viscosity values. The mean thyroid viscosity by ViPLUS for normal thyroid tissue was of 2.42 ± 0.41 Pa·s. Viscosity assessment by Supersonic ViPLUS is an innovative, non-invasive technique that has proven to be useful for thyroid US evaluation and remains to demonstrate its effectiveness in identifying patients with thyroid disease.

14.
Diagnostics (Basel) ; 12(6)2022 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-35741261

RESUMO

Liver fibrosis is the most significant prognostic factor in chronic liver disease (CLD). Clinical practice guidelines recommend the use of non-invasive techniques, such as two-dimensional shear-wave elastography (2D-SWE), to assess liver stiffness as a marker of fibrosis. Several other factors influence liver stiffness in addition to liver fibrosis. It is presumed that changes due to necro-inflammation modify the propagation of shear waves (dispersion). Therefore, new imaging techniques that investigate the dispersion properties of shear waves have been developed, which can serve as an indirect method of measuring liver viscosity (Vi PLUS). Defining the reference values in healthy subjects among different age groups and genders and analyzing the factors that influence these values is essential. However, published data on liver viscosity are still limited. This is the first study that aimed to assess the normal range of liver viscosity values in subjects with healthy livers and analyze the factors that influence them. One hundred and thirty-one consecutive subjects with healthy livers were enrolled in this prospective study. The results showed that Vi PLUS is a highly feasible method. Liver stiffness, age and BMI influenced the liver viscosity values. The mean liver viscosity by Vi PLUS in subjects with healthy livers was 1.59 Pa·s.

15.
J Sleep Res ; 31(2): e13472, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34476847

RESUMO

The hormone fibroblast growth factor 21 (FGF21) modulates tissue metabolism and circulates at higher levels in metabolic conditions associated with chronic sleep-wake disruption, such as type 2 diabetes and obesity. In the present study, we investigated whether acute sleep loss impacts circulating levels of FGF21 and tissue-specific production, and response pathways linked to FGF21. A total of 15 healthy normal-weight young men participated in a randomised crossover study with two conditions, sleep loss versus an 8.5-hr sleep window. The evening before each intervention, fasting blood was collected. Fasting, post-intervention morning skeletal muscle and adipose tissue samples underwent quantitative polymerase chain reaction and DNA methylation analyses, and serum FGF21 levels were measured before and after an oral glucose tolerance test. Serum levels of FGF21 were higher after sleep loss compared with sleep, both under fasting conditions and following glucose intake (~27%-30%, p = 0.023). Fasting circulating levels of fibroblast activation protein, a protein which can degrade circulating FGF21, were not altered by sleep loss, whereas DNA methylation in the FGF21 promoter region increased only in adipose tissue. However, even though specifically the muscle exhibited transcriptional changes indicating adverse alterations to redox and metabolic homeostasis, no tissue-based changes were observed in expression of FGF21, its receptors, or selected signalling targets, in response to sleep loss. In summary, we found that acute sleep loss resulted in increased circulating levels of FGF21 in healthy young men, which may occur independent of a tissue-based stress response in metabolic peripheral tissues. Further studies may decipher whether changes in FGF21 signalling after sleep loss modulate metabolic outcomes associated with sleep or circadian disruption.


Assuntos
Diabetes Mellitus Tipo 2 , Estudos Cross-Over , Fatores de Crescimento de Fibroblastos/genética , Fatores de Crescimento de Fibroblastos/metabolismo , Humanos , Masculino , Sono
16.
Diagnostics (Basel) ; 11(5)2021 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-33926073

RESUMO

Non-alcoholic fatty liver disease (NAFLD) is the most common chronic liver disease worldwide. This study aimed to evaluate the performance of four ultrasound-based techniques for the non-invasive multiparametric (MPUS) assessment of liver fibrosis (LF), steatosis (HS), and inflammation in patients with NAFLD. We included 215 consecutive adult patients with NAFLD (mean age: 54.9 ± 11.7; 54.5% were male), in whom LF, HS, and viscosity were evaluated in the same session using four new ultrasound-based techniques embedded on the Aixplorer MACH 30 system: ShearWave Elastography (2D-SWE.PLUS), Sound Speed Plane-wave UltraSound (SSp.PLUS), Attenuation Plane-wave UltraSound (Att.PLUS), and Viscosity Plane-wave UltraSound (Vi.PLUS). Transient Elastography (TE) with Controlled Attenuation Parameter (CAP) (FibroScan) were considered as control. All elastographic measurements were performed according to guidelines. Valid liver stiffness measurements (LSM) were obtained in 98.6% of patients by TE, in 95.8% of patients by 2D-SWE.PLUS/Vi.PLUS, and in 98.1% of patients by Att.PLUS/SSp.PLUS, respectively. Therefore, 204 subjects were included in the final analysis. A strong correlation between LSMs by 2D-SWE.PLUS and TE (r = 0.89) was found. The best 2D-SWE.PLUS cut-off value for the presence of significant fibrosis (F ≥ 2) was 7 kPa. Regarding steatosis, SSp.PLUS correlated better than Att.PLUS with CAP values: (r = -0.74) vs. (r = 0.45). The best SSp.PLUS cut-off value for predicting the presence of significant steatosis was 1524 m/s. The multivariate regression analysis showed that Vi.PLUS values were associated with BMI and LSM by 2D-SWE.PLUS. In conclusion, MPUS was useful for assessing fibrosis, steatosis, and inflammation in a single examination in patients with NAFLD.

17.
Ultrasound Med Biol ; 47(7): 1692-1703, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33832824

RESUMO

The goal of this study was to evaluate the performance of two new ultrasound-based techniques (ShearWave PLUS elastography [2-D-SWE PLUS], SSp PLUS Imaging [SSp PLUS]) implemented on the Aixplorer Mach 30 ultrasound system (Supersonic Imagine, Aix-en-Provence, France) for the non-invasive assessment of liver steatosis and fibrosis, using transient elastography (TE) with the controlled attenuation parameter (CAP) as reference. This monocentric cross-sectional study included 133 consecutive adult patients with chronic hepatopathies. Liver stiffness and steatosis were evaluated in the same session using the techniques mentioned above. An excellent correlation was observed between liver stiffness measurements obtained with 2-D-SWE PLUS and TE (r = 0.92, p < 0.0001). The best cutoff value of 2-D-SWE PLUS for predicting F≥2 was 6.8 kPa; for F≥3, 8.4 kPa; and for F4, 11 kPa. With respect to steatosis evaluation, a strong negative correlation between CAP and SSp PLUS values (r = -0.70, p < 0.0001) was obtained. The best SSp PLUS cutoff value for predicting steatosis was 1537 m/s.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Fígado Gorduroso/diagnóstico por imagem , Cirrose Hepática/diagnóstico por imagem , Software , Adulto , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ultrassonografia/métodos
18.
Diagnostics (Basel) ; 10(9)2020 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-32878078

RESUMO

AIM: This study aimed to evaluate the diagnosis performance of time-harmonic elastography (THE) technique in real life in assessing liver fibrosis, considering vibration-controlled transient elastography (VCTE) as a reference method. MATERIAL AND METHOD: We prospectively evaluated outpatients from the gastroenterology department. Liver stiffness (LS) was measured by the THE system by dedicated operators, and by VCTE by experienced operators. The diagnostic accuracy of THE in staging liver fibrosis was assessed. We also performed an intra- and interobserver reproducibility sub-analysis on a sub-group of 27 subjects, where liver stiffness measurements (LSM) were performed by a novice, an elastography expert, and an ultrasound expert. RESULTS: Of the 165 patients, using VCTE cut-off values, 49.6% were F0-F1, 15.7% were F2, 6.6% were F3, and 28.1% were F4. A direct, significant and strong correlation (r = 0.82) was observed between LSM assessed by VCTE and THE, p < 0.0001. The cut-off for ruling out liver cirrhosis (LC) by THE on our study group was <1.61 m/s (7.77 kPa)-AUROC = 0.90 [95% CI (0.82-0.93)], Se = 90.7%, Sp = 66.6%, PPV = 55.7%, NPV = 93.9%. The cut-off for ruling in LC by THE was >1.83 m/s (10 kPa)-AUROC = 0.90 [95% CI (0.82-0.93)], p < 0.0001, Se = 65.1%, Sp = 96.7%, PPV = 90.3%, NPV = 85.7%. The overall agreement between examiners was excellent: 0.94 (95% CI: 0.89-0.97); still, the ICCs were higher for the more experienced elastography examiner: 0.92 (95% CI: 0.82-0.96) vs. 0.94 (95% CI: 0.87-0.97) vs. 0.97 (95% CI: 0.95-0.99). CONCLUSIONS: THE is a feasible and reproducible elastography technique that can accurately rule in and rule out advanced liver disease.

19.
Chirurgia (Bucur) ; 113(4): 486-496, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30183579

RESUMO

OBJECTIVE: The aim of this study is to verify if the experience on 4 years in using minimally invasive techniques in the treatment of CE could match regarding the indications and results with the major studies on topic. METHOD: During 03.2014 - 03. 2018 period, 38 PAIR, 28 MoCaT procedures and 7 percutaneous drainages have been performed at 51 patients from 76 cases of hydatid hepatic cysts (67,1%). There were 26 men and 25 women, and the age ranged from 19 to 78. 7 patients have had 2 hydatid hepatic cysts or more and 2 procedures were performed at 3 of those patients; other 11 patients needed the second procedure during the surveillance. Results: The evolution of the patients was favorable, and the surveillance was 2 years postintervention at least. There were no major surgical adverse effects. We defined as an expected result obtaining a scar lesion or a small cavity with calcified walls (hyperechoic). Only 2 (3,9%) patients needed conversion to open surgery. The complications we have faced were represented by the cystic-biliary fistula in 15 cases (29,4%) and the re-opening of the cyst's cavity in 11 cases (21,67%). Conclusions: The percutaneous treatment of CE is safe and effective, following the correct assignation according with the cysts type. The percutaneous treatment of CE is an easier alternative to the open surgery and has lower rate of complications and relapses, and a shorter hospitalisation. Now routine, it becomes slighty the first option for invasive treatment of CE. The role of open surgery is restricted to CE with severe complications.


Assuntos
Equinococose Hepática/cirurgia , Adulto , Idoso , Animais , Drenagem/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos , Recidiva , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...