Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 89(10): 10I116, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399923

RESUMO

The JET gamma-ray cameras have been recently upgraded within the gamma-ray camera upgrade project in support of development of JET high performance deuterium plasma scenarios and in preparation of deuterium-tritium experiments. New, dedicated detectors based on a LaBr3 crystal and silicon photo-multipliers have been developed and replaced pre-existing CsI detectors in all 19 channels. The new instrument gives opportunity of making two-dimensional gamma-ray measurements with a counting rate capability exceeding 1 MCounts/s (MCps) and energy resolution better than 5% at 1.1 MeV. The upgrade is of relevance for fast ion and runaway electron physics studies in high performance deuterium discharges and also in plasmas with tritium at neutron yields in the range up to about 5 × 1017 n/s.

2.
Radiat Prot Dosimetry ; 180(1-4): 102-108, 2018 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-29040768

RESUMO

The design and operation of ITER experimental fusion reactor requires the development of neutron measurement techniques and numerical tools to derive the fusion power and the radiation field in the device and in the surrounding areas. Nuclear analyses provide essential input to the conceptual design, optimisation, engineering and safety case in ITER and power plant studies. The required radiation transport calculations are extremely challenging because of the large physical extent of the reactor plant, the complexity of the geometry, and the combination of deep penetration and streaming paths. This article reports the experimental activities which are carried-out at JET to validate the neutronics measurements methods and numerical tools used in ITER and power plant design. A new deuterium-tritium campaign is proposed in 2019 at JET: the unique 14 MeV neutron yields produced will be exploited as much as possible to validate measurement techniques, codes, procedures and data currently used in ITER design thus reducing the related uncertainties and the associated risks in the machine operation.


Assuntos
Deutério/análise , Nêutrons , Reatores Nucleares/instrumentação , Monitoramento de Radiação/instrumentação , Monitoramento de Radiação/métodos , Proteção Radiológica/instrumentação , Trítio/análise , Doses de Radiação
3.
Rev Sci Instrum ; 88(10): 103505, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29092477

RESUMO

The present paper describes the findings of the calibration of the neutron yield monitors on the Joint European Torus (JET) performed in 2013 using a 252Cf source deployed inside the torus by the remote handling system, with particular regard to the calibration of fission chambers which provide the time resolved neutron yield from JET plasmas. The experimental data obtained in toroidal, radial, and vertical scans are presented. These data are first analysed following an analytical approach adopted in the previous neutron calibrations at JET. In this way, a calibration function for the volumetric plasma source is derived which allows us to understand the importance of the different plasma regions and of different spatial profiles of neutron emissivity on fission chamber response. Neutronics analyses have also been performed to calculate the correction factors needed to derive the plasma calibration factors taking into account the different energy spectrum and angular emission distribution of the calibrating (point) 252Cf source, the discrete positions compared to the plasma volumetric source, and the calibration circumstances. All correction factors are presented and discussed. We discuss also the lessons learnt which are the basis for the on-going 14 MeV neutron calibration at JET and for ITER.

4.
Rev Sci Instrum ; 87(11): 11D833, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910565

RESUMO

A prototype Single crystal Diamond Detector (SDD) was installed at the Joint European Torus (JET) in 2013 along an oblique line of sight and demonstrated the possibility to carry out neutron spectroscopy measurements with good energy resolution and detector stability in discharges heated by neutral beam injection and radio-frequency waves. Starting from these positive results, within the Vertical Neutron Spectrometer project of the Joint European Torus, we have developed a pixelated instrument consisting of a matrix of 12 independent SDDs, called the Diamond Vertical Neutron Spectrometer (DVNS), which boosts the detection efficiency of a single SDD by an order of magnitude. In this paper we describe the main features of the DVNS, including the detector design, energy resolution, and data acquisition system for on-line processing. Preliminary spectroscopy measurements of 2.5 MeV neutrons from the present deuterium plasma at JET are finally presented.

5.
Rev Sci Instrum ; 87(11): 11D835, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910546

RESUMO

We present the results of analysis of triton burn-up process using the data from diamond detector. Neutron monitor based on CVD diamond was installed in JET torus hall close to the plasma center. We measure the part of 14 MeV neutrons in scenarios where plasma current varies in a range of 1-3 MA. In this experiment diamond neutron monitor was also able to detect strong gamma bursts produced by runaway electrons arising during the disruptions. We can conclude that CVD diamond detector will contribute to the study of fast particles confinement and help predict the disruption events in future tokamaks.

6.
Rev Sci Instrum ; 85(2): 023505, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24593359

RESUMO

The Joint European Torus (JET, Culham, UK) is the largest tokamak in the world devoted to nuclear fusion experiments of magnetic confined Deuterium (D)/Deuterium-Tritium (DT) plasmas. Neutrons produced in these plasmas are measured using various types of neutron detectors and spectrometers. Two of these instruments on JET make use of organic liquid scintillator detectors. The neutron emission profile monitor implements 19 liquid scintillation counters to detect the 2.45 MeV neutron emission from D plasmas. A new compact neutron spectrometer is operational at JET since 2010 to measure the neutron energy spectra from both D and DT plasmas. Liquid scintillation detectors are sensitive to both neutron and gamma radiation but give light responses of different decay time such that pulse shape discrimination techniques can be applied to identify the neutron contribution of interest from the data. The most common technique consists of integrating the radiation pulse shapes within different ranges of their rising and/or trailing edges. In this article, a step forward in this type of analysis is presented. The method applies a tomographic analysis of the 3-dimensional neutron and gamma pulse shape and pulse height distribution data obtained from liquid scintillation detectors such that n/γ discrimination can be improved to lower energies and additional information can be gained on neutron contributions to the gamma events and vice versa.

7.
Rev Sci Instrum ; 83(10): 10E124, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23130800

RESUMO

The neutron field parameters (fluence and energy distribution) at a specific location outside the JET Torus Hall have been measured by means of super-heated fluid detectors (or "bubble detectors") in combination with an independent, time-of-flight, technique. The bubble detector assemblies were placed at the end of a vertical line of sight at about 16 m from the tokamak mid plane. Spatial distributions of the neutron fluence along the radial and toroidal directions have been obtained using two-dimensional arrays of bubble detectors. Using a set of three bubble detector spectrometers the neutron energy distribution was determined over a broad energy range, from about 10 keV to above 10 MeV, with an energy resolution of about 30% at 2.5 MeV. The very broad energy response allowed for the identification of energy features far from the main fusion component (around 2.45 MeV for deuterium discharges).

8.
Rev Sci Instrum ; 81(10): 10D329, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21033851

RESUMO

Accuracy of 10% is demanded to the absolute fusion measurement on ITER. To achieve this accuracy, a functional combination of several types of neutron measurement subsystem, cross calibration among them, and in situ calibration are needed. Neutron transport calculation shows the suitable calibration source is a DT/DD neutron generator of source strength higher than 10(10) n/s (neutron/second) for DT and 10(8) n/s for DD. It will take eight weeks at the minimum with this source to calibrate flux monitors, profile monitors, and the activation system.

9.
Rev Sci Instrum ; 81(10): 10E136, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21061488

RESUMO

Notwithstanding the advances of the past decades, significant developments are still needed to satisfactorily diagnose "burning plasmas." D­T plasmas indeed require a series of additional measurements for the optimization and control of the configuration: the 14 MeV neutrons, the isotopic composition of the main plasma, the helium ash, and the redistribution and losses of the alpha particles. Moreover a burning plasma environment is in general much more hostile for diagnostics than purely deuterium plasmas. Therefore, in addition to the development and refinement of new measuring techniques, technological advances are also indispensable for the proper characterization of the next generation of devices. On JET an integrated program of diagnostic developments, for JET future and in preparation for ITER, has been pursued and many new results are now available. In the field of neutron detection, the neutron spectra are now routinely measured in the energy range of 1­18 MeV by a time of flight spectrometer and they have allowed studying the effects of rf heating on the fast ions. A new analysis method for the interpretation of the neutron cameras measurements has been refined and applied to the data of the last trace tritium campaign (TTE). With regard to technological upgrades, chemical vapor deposition diamond detectors have been qualified both as neutron counters and as neutron spectrometers, with a potential energy resolution of about one percent. The in situ calibration of the neutron diagnostics, in preparation for the operation with the ITER-like wall, is also promoting important technological developments. With regard to the fast particles, for the first time the temperature of the fast particle tails has been obtained with a new high purity Germanium detector measuring the gamma emission spectrum from the plasma. The effects of toroidal Alfven eigenmodes modes and various MHD instabilities on the confinement of the fast particles have been determined with a combination of gamma ray cameras, neutral particle analyzers, scintillator probe, and Faraday cups. From a more technological perspective, various neutron filters have been tested to allow measurement of the gamma ray emission also at high level of neutron yield.

10.
Rev Sci Instrum ; 81(10): 10D331, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21058458

RESUMO

In ITER, α particle loss measurements will be required in order to understand the alpha particle physics. Techniques capable of operating in a fusion reactor environment need further development. Recent experimental studies on JET demonstrated the potential of nuclear activation to measure the flux of escaping MeV ions. New results from MeV ion induced activation of metallic, ceramic, and crystal samples placed near the plasma edge are reported. Activation products were measured as function of orientation with respect to the magnetic field as well as function of the distance to the plasma. Sample activity was measured using ultralow-level gamma-ray spectrometry. Distribution of 14.68 MeV fusion proton induced activation products is strongly anisotropic in agreement with simulations and falls off sharply with increasing distance to the plasma. Prospects for using the technique in ITER are discussed.

11.
Rev Sci Instrum ; 80(6): 063505, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19572466

RESUMO

Burning plasma experiments such as ITER and DEMO require diagnostics capable of withstanding the harsh environment generated by the intense neutron flux and to maintain stable operating conditions for times longer than present day systems. For these reasons, advanced control and monitoring (CM) systems will be necessary for the reliable operation of diagnostics. This paper describes the CM system of the upgraded magnetic proton recoil neutron spectrometer installed at the Joint European Torus focusing in particular on a technique for the stabilization of the gain of the photomultipliers coupled to the neutron detectors. The results presented here show that this technique provides good results over long time scales. The technique is of general interest for all diagnostics that employ scintillators coupled to photomultiplier tubes.

12.
Rev Sci Instrum ; 79(10): 10E504, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19068503

RESUMO

Activation studies were performed in JET with new in-vessel activation monitors. Though primarily dedicated to R&D in the challenging issue of lost diagnostics for ITER, which is being addressed at JET with several techniques, these monitors provide for both neutron and charged particle fluences. A set of samples with different orientation with respect to the magnetic field is transported inside the torus by means of a manipulator arm (in contrast with the conventional JET activation system with pneumatic transport system). In this case, radionuclides with longer half-life were selected and ultralow background gamma-ray measurements were needed. The irradiation was closer to the plasma and this potentially reduces the neutron scattering problem. This approach could also be of interest for ITER, where the calibration methods have yet to be developed. The MCNP neutron transport model for JET was modified to include the activation probe and so provide calculations to help assess the new data. The neutron induced activity on the samples are well reproduced by the calculations.

13.
Phys Rev Lett ; 93(11): 115001, 2004 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-15447347

RESUMO

Gamma-ray spectra from nuclear reactions between fusion-born alpha (alpha) particles and Be impurities were measured for the first time in deuterium-tritium plasmas in the Joint European Torus. The time dependence of the measured spectra allowed the determination of the density evolution of fast alpha particles. Correlation between the decay time of the gamma-ray emission and the plasma parameters in different plasma scenarios was established. Results are consistent with classical slowing down of the alpha particles in discharges with high plasma currents and monotonic q-profiles. In low plasma current discharges and in the discharges with large on-axis current holes (extreme reversal central magnetic shear), the gamma-ray emission decay times are shorter than the classical slowing down times, indicating an alpha-particle confinement degradation in such discharges in line with theoretical predictions.

14.
Phys Rev Lett ; 89(11): 115004, 2002 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-12225145

RESUMO

Experiments on the JET tokamak show that the wave-induced pinch in the presence of toroidally asymmetric waves can provide a tool for controlling the profile of ion-cyclotron-resonant 3He ions. Direct evidence for the wave-induced pinch has been obtained from the measured gamma-ray emission profiles. Concurrent differences in the excitation of Alfvén eigenmodes (AEs), sawtooth stabilization, electron temperatures, and fast-ion stored energies are observed. The measured location of the AEs and gamma-ray emission profiles are consistent with the fast-ion radial gradient providing the drive for AEs.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA