Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Pharm Biomed Anal ; 241: 115982, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38237542

RESUMO

In recent years, there has been a growing interest in the therapeutic potential of natural compounds, particularly of plant origin, owing to their demonstrated anti-inflammatory properties. Among these, Anacardium occidentale, commonly known as cashew, has garnered significant attention due to its reputed health benefits. This study aim to establish a correlation between the bioactive compounds contained in the extracts of Anacardium occidentale and its anti-inflammatory activity. Dried Anacardium occidentale leaves powder was used as the extraction matrix. Extraction techniques are maceration, pressurized fluid extraction (PFE), and supercritical fluid extraction (SFE). The preliminary analysis of extracts was made by LC-MS/MS. The Response Surface Methodology (RSM), Principal Component Analysis (PCA), and heat maps were employed to model the influence of experimental conditions on extraction yield and peak area of specific compounds from the plant. To evaluate anti-inflammatory activity, RAW 264.7 cells were cultured, activated with LPS, and treated with varying concentrations of the plant extracts. Cell proliferation was assessed using the XTT assay. Indeed, Anacardium occidentale extracts contain anacardic acids, cardanols, and cardol, with distinct profiles yielded by SFE and ethanol-based methods. RSM shows that temperature and ethanol, as additives to CO2, significantly affect extraction efficiency in both PFE and SFE. Moreover, this composition with SFE demonstrate higher selectivity for specific group of compounds. The extracts exhibit anti-inflammatory properties without cytotoxicity in macrophages, reducing levels of pro-inflammatory proteins COX-2, COX-1, and TLR4 in activated cells. This suggests their potential as anti-inflammatory agents without adverse effects on cell viability or pro-inflammatory protein levels in non-activated cells. Overall, these findings underscore the promising therapeutic potential of Anacardium occidentale extracts in mitigating inflammation, while also providing crucial insights into optimizing the extraction process for targeted compound isolation. Thus, this makes a good prospect for the development of anti-inflammatory drugs from this plant.


Assuntos
Alcaloides , Anacardium , Dióxido de Carbono , Cromatografia Líquida , Espectrometria de Massas em Tandem , Anti-Inflamatórios/farmacologia , Extratos Vegetais/farmacologia , Etanol
2.
Cancer Cell Int ; 23(1): 268, 2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-37950262

RESUMO

Colorectal cancer (CRC) is one of the foremost causes of cancer-related deaths. Lately, a close connection between the course of CRC and the intestinal microbiota has been revealed. Vitamin K2 (VK2) is a bacterially derived compound that plays a crucial role in the human body. Its significant anti-cancer properties may result, inter alia, from a quinone ring possessing a specific chemical structure found in many chemotherapeutics. VK2 can be supplied to our body exogenously, i.e., through dietary supplements or fermented food (e.g., yellow cheese, fermented soybeans -Natto), and endogenously, i.e., through the production of bacteria that constantly colonize the human microbiome of the large intestine.This paper focuses on endogenous K2 synthesized by the most active members of the human gut microbiome. This analysis tested 86 intestinally derived bacterial strains, among which the largest VK2 producers (Lactobacillus, Bifidobacterium, Bacillus) were selected. Moreover, based on the chosen VK2-MK4 homolog, the potential of VK2 penetration into Caco-2 cells in an aqueous environment without the coexistence of fats, pancreatic enzymes, or bile salts has been displayed. The influence of three VK2 homologs: VK2-MK4, VK2-MK7 and VK2-MK9 on apoptosis and necrosis of Caco-2 cells was tested proving the lack of their harmful effects on the tested cells. Moreover, the unique role of long-chain homologs (VK2-MK9 and VK2-MK7) in inhibiting the secretion of pro-inflammatory cytokines such as IL-8 (for Caco-2 tissue) and IL-6 and TNFα (for RAW 264.7) has been documented.

3.
Mikrochim Acta ; 190(10): 391, 2023 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-37704761

RESUMO

A original electrochemical sensing platform, based on screen-printed electrodes modification with plasma polymerized acrylonitrile (pp-AN) nanofilms is proposed. For that purpose, plasma-enhanced chemical vapor deposition (PECVD) process was conducted in a parallel plate (13.56 MHz) plasma reactor for 2 min with discharge power of 10 W. The surface topography and electrochemical properties of prepared sensors were investigated by X-ray photoelectron spectroscopy, scanning electron microscopy, energy dispersion spectroscopy, electrochemical impedance spectroscopy, and cyclic voltammetry. The electrochemical characteristics of pp-AN/SPCE and pp-AN/SPAuE sensors was investigated for model redox pair [Fe(CN)6]4-/3-. Conducted research confirmed the excellent chemical stability, durability, wide potential window, high signal-to-noise (S/N) ratio, and, most importantly, the ability to standardize the sensors. The pp-AN/SPCE sensor was applied to the determination of bupropion, an antidepressant drug whose intake has increased dramatically during the COVID-19 pandemic. The voltammetric response of pp-AN/SPCE for BUP was linear in two concentration ranges of 0.63-10.0 and 10.0-50.0 µmol L-1, with a detection limit of 0.21 µmol L-1. Satisfactory recoveries (96.2-102%) and good precision (RSD below 4.1%) obtained for environmental and biological samples confirmed the usefulness of the sensor for the analysis of various kinds of samples.

4.
J Hazard Mater ; 448: 130953, 2023 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-36860040

RESUMO

In this work, the fabrication and analytical application of a novel, unique, mercury-free, and user-friendly voltammetric sensor of Ni(II) based on glassy carbon electrode (GCE) modified with zeolite(MOR)/graphite(G)/dimethylglyoxime(DMG) composite (MOR/G/DMG-GCE) and the voltammetric procedure for highly selective, ultra-trace determination of nickel ions were reported for the first time. Deposition of a thin layer of the chemically active MOR/G/DMG nanocomposite enables the selective and effective accumulation of Ni(II) ions in the form of the DMG-Ni(II) complex. In 0.1 mol L-1 ammonia buffer (pH 9.0), the MOR/G/DMG-GCE exhibited linear response in the Ni(II) ions concentration range of 0.86 - 19.61 µg L-1 and 0.57 - 15.75 µg L-1, for the accumulation time of 30 s and 60 s, respectively. For 60 s of accumulation time, the limit of detection (S/N = 3) was 0.18 µg L-1 (3.04 nM), and sensitivity of 0.202 µA L µg-1 was achieved. The developed protocol was validated by the analysis of wastewater certified reference materials. Its practical usefulness was confirmed by the determination of nickel released from metallic jewelry submerged in artificial sweat and stainless steel pot during water boiling. The obtained results were verified by electrothermal atomic absorption spectroscopy as a reference method.

5.
Molecules ; 27(14)2022 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-35889475

RESUMO

A novel voltammetric method for the sensitive and selective determination of cadmium and lead ions using screen-printed carbon electrodes (SPCEs) modified with carbon-deposited natural halloysite (C_Hal) and multi-walled carbon nanotubes (MWCNTs) was developed. The electrochemical properties of the proposed sensor were investigated by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV), while the morphology and structure were established by scanning electron microscopy (SEM) and X-ray powder diffraction (XRD). A two-factorial central composite design (CCD) was employed to select the composition of the nanocomposite modifying the electrode surface. The optimal measuring parameters of differential pulse anodic stripping voltammetry (DPASV) used for quantitative analysis were established with the Nelder-Mead simplex method. In the analytical investigation of Cd(II) and Pb(II) ions by DPASV, the MWCNTs/C_Hal/Nafion/SPCE exhibited a linear response in the concentration range of 0.1-10.0 µmol L-1 (for both ions) with a detection limit of 0.0051 and 0.0106 µmol L-1 for Pb(II) and Cd(II), respectively. The proposed sensor was successfully applied for the determination of metal ions in different natural water and honey samples with recovery values of 96.4-101.6%.


Assuntos
Nanotubos de Carbono , Cádmio/química , Argila , Técnicas Eletroquímicas/métodos , Eletrodos , Íons , Chumbo/análise , Nanotubos de Carbono/química
6.
Mikrochim Acta ; 188(10): 323, 2021 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-34487246

RESUMO

The utilization of environmentally friendly nanoporous natural zeolite exchanged with Ni2+ ions (NiZ) and conductive carbon black (CB) in the fabrication of a novel and selective voltammetric sensor of vitamin B6 (VB6) is presented. The used clinoptilolite-rich zeolite material and CB were characterized in terms of morphology and textural properties. The superior properties of Ni-zeolite/carbon black modified glassy carbon electrode (NiZCB-GCE), arising from the synergistic effect of combining the unique features of zeolite and conductive carbon black, were confirmed by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) measurements. In the determination of VB6 with the use of differential pulse voltammetry (DPV), the optimization of the pH value of supporting electrolyte and instrumental parameters, as well as the interference study were performed. Under optimized conditions, the oxidation peak current at the potential +0.72 V vs. Ag | AgCl | 3 M KCl reference electrode was linear to the VB6 concentration in the range 0.050 to 1.0 mg L-1 (0.30-5.9 µmol L-1) (R = 0.9993). The calculated limit of detection (LOD, S/N = 3), equal to 15 µg L-1 (0.09 µmol L-1), was much better compared to chemically modified electrodes with other carbon-based materials. The RSD for 0.5 mg L-1 was in the range 2.5-5.4% (n = 4). The developed NiZCB-GCE was successfully applied to the determination of VB6 in commercially available multivitamin dietary supplements, food, and water samples. The obtained recoveries ranged from 95 to 106%.


Assuntos
Técnicas Eletroquímicas/métodos , Nanocompostos/química , Fuligem/química , Vitamina B 6/análise , Zeolitas/química , Suplementos Nutricionais/análise , Bebidas Energéticas/análise , Limite de Detecção , Níquel/química , Porosidade , Águas Residuárias/análise
7.
Talanta ; 232: 122491, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34074448

RESUMO

Urinalysis is a simple and non-invasive approach for the diagnosis and monitoring of various health disorders. While urinalysis is predominantly confined to clinical laboratories the non-invasive sample collection makes it applicable in wide range of settings outside of central laboratory confinements. In this respect, 3D printed devices integrating sensors for measuring multiple parameters may be one of the most viable approaches to ensure cost-effectiveness for widespread use. Here we evaluated such a system for the multiplexed determination of sodium, potassium and calcium ions in urine samples with ion-selective electrodes based on state of the art octadecylamine-functionalized multi-walled carbon nanotube (OD-MWCNT) solid contacts. The electrodes were tested in the clinically relevant concentration range, i.e. ca. 10-4 - 10-1 mol L-1 and were proven to have Nernstian responses under flow injection conditions. The applicability of the 3D printed flow manifold was investigated through the analysis of synthetic samples and two certified reference materials. The obtained results confirm the suitability of the proposed system for multiplexed ion analysis in urine.


Assuntos
Eletrodos Seletivos de Íons , Potássio , Eletrodos , Íons , Potenciometria , Impressão Tridimensional
8.
Mikrochim Acta ; 188(6): 184, 2021 05 11.
Artigo em Inglês | MEDLINE | ID: mdl-33977404

RESUMO

A voltammetric sensor has been developed based on glassy carbon electrode (GCE) modification with nanocomposite consisting of manganese-based metal-organic framework (JUK-2), multi-walled carbon nanotubes (MWCNTs), and gold nanoparticles (AuNPs) for detection of citalopram (CIT). The composition and morphology of JUK-2-MWCNTs-AuNPs/GCE were characterized by X-ray powder diffraction (XRD), Fourier-transform infrared spectroscopy (FT-IR), energy dispersion spectroscopy (EDS), and scanning electron microscopy (SEM). The electrochemical properties investigated using electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) indicated that the fabricated hybrid material exhibits the properties of mixed ion-electron conductor (MIEC). Using staircase voltammetry (SCV), under optimized conditions, the fabricated sensor shows a linear response in three CIT concentration ranges, 0.05-1.0, 1.0-10.0 and 15.0-115.0 µmol L-1, with a detection limit of 0.011 µmol L-1. The JUK-2-MWCNTs-AuNPs/GCE was successfully employed for the determination of CIT in pharmaceutical, environmental waters, and biological samples with satisfactory recoveries (98.6-104.8%).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...