Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 86
Filtrar
1.
Heart Rhythm O2 ; 5(1): 34-40, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38312199

RESUMO

Background: Long-term rhythm monitoring to detect atrial fibrillation (AF) following a cryptogenic stroke (CS) is well established. However, the burden of organized atrial arrhythmias in this population is not well defined. Objective: The purpose of this study was to assess the incidence and risk factors for organized atrial arrhythmias in patients with CS. Methods: We evaluated all patients with CS who received an insertable cardiac monitor (ICM) between October 2014 and April 2020. All ICM transmissions categorized as AF, tachycardia, or bradycardia were reviewed. We evaluated the time to detection of organized AF and the combination of either organized atrial arrhythmia or AF. Results: A total of 195 CS patients with ICMs were included (51% men; mean age 66 ± 12 years; mean CHA2DS2-VASC score 4.6). Over mean follow-up of 18.9 ± 11.2 months, organized atrial arrhythmias lasting ≥30 seconds were detected in 45 patients (23%), of whom 62% did not have AF. Seventeen patients had both organized atrial arrhythmia and AF, and another 21 patients had AF only. Compared to those with normal left atrial size, patients with left atrial enlargement had a higher adjusted risk for development of atrial arrhythmias (mild left atrial enlargement: hazard ratio 1.99; 95% confidence interval 1.06-3.75; moderate/severe left atrial enlargement: hazard ratio 3.06; 95% confidence interval 1.58-5.92). Conclusion: Organized atrial arrhythmias lasting ≥30 seconds are detected in nearly one-fourth of CS patients. Two-thirds of these patients did not have AF. Further studies are required to evaluate the impact of organized atrial arrhythmias on recurrent stroke risk.

3.
JACC Clin Electrophysiol ; 10(1): 31-39, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37943190

RESUMO

BACKGROUND: Bilateral cardiac sympathetic denervation (BCSD) for refractory life-threatening ventricular arrhythmias is a neuromodulatory intervention targeting sympathetically driven focal or re-entrant ventricular arrhythmias. OBJECTIVES: This study sought to provide a more complete and successful option for intervention in patients in whom premature ventricular contraction (PVC) ablation is not feasible or has been unsuccessful. METHODS: A total of 43 patients with >5% PVC burden and concomitant nonischemic cardiomyopathy (NICM) who previously failed medical and ablation therapies were referred for BCSD. All patients underwent bilateral video-assisted thoracoscopic surgical approach with T1-T4 sympathectomy. Primary effectiveness endpoints were postprocedural PVC burden resolution, improvement in left ventricular ejection fraction (LVEF), and cessation of antiarrhythmic drugs (AADs). Safety endpoints included peri- and postprocedural complications. Outcomes were assessed over a 1-year follow-up period. RESULTS: Among the 43 patients who underwent BCSD, the mean age was 52.3 ± 14.7 years, 69.8% of whom were male patients. Presenting mean LVEF was 38.7% ± 7.8%, and PVC burden was 23.7% ± 9.9%. There were significant reductions in PVC burden postprocedurally (1.3% ± 1.1% post-BCSD, compared with 23.7% ± 9.9% pre-BCSD, P < 0.001) and improvements in LVEF (46.3% ± 9.5% post-BCSD, compared with 38.7% ± 7.8% pre-BCSD, P < 0.001). The rate of ICD therapies decreased from 81.4% (n = 35) to 11.6% (n = 5) (P < 0.001), leading to a significant reduction in use of AADs (100.0% to 11.6%, P < 0.001) and improvement in mean NYHA functional class (2.5 ± 0.5 to 1.4 ± 0.2, P < 0.001). Major intraoperative complications were seen in 4.7% of patients (hemothorax and chylothorax). Of the patients, 81.4% (n = 35) experienced no mortality or major complications over a 1-year follow-up period, with the remaining still within their first year postprocedure. CONCLUSIONS: BCSD is effective for the management of refractory PVCs and ventricular tachycardia who have failed previous ablation therapy.


Assuntos
Cardiomiopatias , Complexos Ventriculares Prematuros , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Volume Sistólico , Função Ventricular Esquerda , Antiarrítmicos/uso terapêutico , Simpatectomia/efeitos adversos , Simpatectomia/métodos
4.
J Interv Card Electrophysiol ; 67(3): 625-635, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37858000

RESUMO

BACKGROUND: Frailty is associated with significant morbidity and mortality and may have clinical implications in an advanced age population with atrial fibrillation undergoing left atrial appendage occlusion (LAAO). We sought to develop a novel frailty scale to predict worse outcomes in patients undergoing LAAO. METHODS: Patients in the NCDR LAAO Registry between 2016 and 2021 receiving percutaneous LAAO devices were categorized as non-frail (0 points), pre-frail (1-3 points), or frail (4-5 points) based on a 5-point scale representing multiple domains of frailty: hemoglobin <13.0 g/dL in male, <12.0 g/dL in female; creatinine ≥1.2 mg/dL; albumin <3.5 g/dL; body mass index <20 kg/m2; and increased risk of falls. RESULTS: Of 57,728 patients, 44,360 (76.8%) were pre-frail and 7693 (13.3%) were frail. Compared to non-frail, pre-frail and frail patients were older, had a higher burden of co-morbidities, and more disability based on the Modified Rankin Scale. Compared to non-frail patients after adjustment, frail patients were at higher risk of in-hospital major complication (OR 1.29, 95% 1.02-1.62, p = 0.01), any complication (OR 1.29, 95% CI 1.09-1.52, p = 0.0005), and death (OR 5.79, 95% CI 1.75-19.17, p = 0.001), while no difference was observed in pre-frail patients. At 45-day follow-up, there was no difference in the risk of complications in frail patients as compared to non-frail, although mortality was significantly higher (OR 3.01, 95% CI 1.97-4.85, p < 0.0001). CONCLUSION: A simple and practical frailty scale accurately predicts adverse events in patients undergoing LAAO. The 13% of patients considered frail were at significantly higher risk of in-hospital adverse events and 45-day mortality.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Fragilidade , Acidente Vascular Cerebral , Humanos , Masculino , Feminino , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fragilidade/epidemiologia , Fragilidade/complicações , Estudos Retrospectivos , Sistema de Registros , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
7.
Artigo em Inglês | MEDLINE | ID: mdl-37773559

RESUMO

BACKGROUND: Pulmonary vein isolation (PVI) is the cornerstone of catheter ablation of atrial fibrillation (AF); however, the results are suboptimal for persistent AF. The left atrial posterior wall (LAPW) is thought to be a major additional area in initiation and perpetuation of persistent AF. Therefore, adjunctive ablation of the posterior wall may reduce AF recurrence in patients with persistent AF. OBJECTIVE: The objective of this study was to compare outcomes of catheter ablation in patients with persistent AF using PVI alone versus a combination of PVI and LAPW isolation. METHODS: Literature search was conducted in PubMed, PubMed Central, Scopus, and Embase since inception to February 2023. Screening of studies was done via Covidence software. Risk of bias assessment was done using appropriate tools. Data extraction and a narrative synthesis were carried out accordingly. RESULTS: Ten studies were included, of which five were randomized controlled trials. PVI with LAPW ablation group had significantly lower recurrence of overall atrial tachyarrhythmia (OR 0.47, CI 0.32-0.70) and AF (OR 0.39, CI 0.23-0.69). In sensitivity analysis, freedom from atrial arrhythmias was noted to be significantly higher in the PVI with LAPW ablation group (OR 2.22, CI 1.36-3.64). However, there was no significant difference in occurrence of atrial flutter (OR 1.36, CI 0.86-2.14) or with periprocedural adverse events (OR 1.10, CI 0.60-1.99). CONCLUSION: LAPW ablation, in addition to PVI, significantly improves the rates of arrhythmia freedom and reduces the recurrence of overall atrial tachyarrhythmia. There was no significant difference in atrial flutter or periprocedural adverse events.

9.
Curr Cardiol Rep ; 25(9): 909-915, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37584874

RESUMO

PURPOSE OF REVIEW: Left atrial appendage closure (LAAC) has shown to be non-inferior to oral anticoagulation (OAC) for non-valvular atrial fibrillation (AF). LAAC is now becoming a leading method for stroke prophylaxis in patients who have atrial fibrillation and are unable to tolerate OAC. There are currently two FDA-approved endocardial closure devices, namely, the Watchman FLX and Amplatzer Amulet. RECENT FINDINGS: Current data highlights that both devices offer similar efficacy and safety for LAAC. While the two devices differ in terms of intraprocedural complication rates, they offer similar short- to long-term outcomes in regard to peri-device leaks, device-related thrombosis, and mortality. With similar risk and safety profiles, both devices are indicated for patients who are unable to tolerate OAC. Newer clinical studies are directed to establish the efficacy of both devices as the primary method for stroke prevention in AF as an alternate to OAC.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , Apêndice Atrial/cirurgia , Resultado do Tratamento , Procedimentos Cirúrgicos Cardíacos/métodos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/tratamento farmacológico , Anticoagulantes/uso terapêutico
10.
Heart Rhythm O2 ; 4(6): 374-381, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37361614

RESUMO

Background: Remote monitoring (RM) has been accepted as a standard of care for follow-up of patients with cardiac implantable electronic devices (CIEDs). However, the resulting data deluge poses major challenge to device clinics. Objective: This study aimed to quantify the data deluge from CIED and stratify these data based on clinical relevance. Methods: The study included patients from 67 device clinics across the United States being remotely monitored by Octagos Health. The CIEDs included implantable loop recorders, pacemakers, implantable cardioverter-defibrillators, cardiac resynchronization therapy defibrillators, and cardiac resynchronization therapy pacemakers. Transmissions were either dismissed before reaching the clinical practice if they were repetitive or redundant or were forwarded if they were either clinically relevant or actionable transmission (alert). The alerts were further classified as level 1, 2, or 3 based on clinical urgency. Results: A total of 32,721 patients with CIEDs were included. There were 14,465 (44.2%) patients with pacemakers, 8381 (25.6%) with implantable loop recorders, 5351 (16.4%) with implantable cardioverter-defibrillators, 3531 (10.8%) with cardiac resynchronization therapy defibrillators, and 993 (3%) with cardiac resynchronization therapy pacemakers. Over a period of 2 years of RM, 384,796 transmissions were received. Of these, 220,049 (57%) transmissions were dismissed, as they were either redundant or repetitive. Only 164,747 (43%) transmissions were transmitted to the clinicians, of which only 13% (n = 50,440) had clinical alerts, while 30.6% (n = 114,307) were routine transmissions. Conclusion: Our study shows that data deluge from RM of CIEDs can be streamlined by utilization of appropriate screening strategies that will enhance efficiency of device clinics and provide better patient care.

11.
Am J Cardiol ; 201: 193-199, 2023 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-37385174

RESUMO

Surgical left atrial appendage (LAA) occlusion with an AtriClip (AtriCure, West Chester, Ohio) is frequently performed for stroke prophylaxis in patients with atrial fibrillation (AF). We conducted a retrospective analysis of all patients with long-standing persistent AF who underwent hybrid convergent ablation and LAA clipping. Contrast-enhanced cardiac computed tomography was performed at 3 to 6 months after LAA clipping to assess the degree of complete closure and the residual LAA stump. A total of 78 patients (64 ± 10 years, 72% male) underwent LAA clipping as part of hybrid convergent AF ablation, from 2019 to 2020. Median size of AtriClip used was 45 mm. Mean LA size was 4.6 ± 1 cm. At 3-to-6 months follow-up computed tomography, 46.2% of patients (n = 36) had a residual stump proximal to the deployed LAA clip. Mean depth of residual stump was 3.95 ± 5.5 mm, with 19% of patients (n = 15) having a stump depth of ≥10 mm and 1 patient requiring more endocardial LAA closure owing to large stump depth. During 1-year follow-up, 3 patients developed stroke; device leak of 6 mm was noted in 1 patient; and none of the patients had a thrombus proximal to the clip. In conclusion, high incidence of residual LAA stump was observed with AtriClip. Larger studies with long-term follow-up are needed to better assess the thromboembolic implications of a residual stump after AtriClip placement.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Acidente Vascular Cerebral , Humanos , Masculino , Feminino , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Procedimentos Cirúrgicos Cardíacos/métodos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Ecocardiografia Transesofagiana/efeitos adversos
12.
J Cardiovasc Electrophysiol ; 34(6): 1418-1426, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37161942

RESUMO

BACKGROUND: It is unclear if the location of implantation of the leadless pacemaker (LP) makes a difference in the incidence of pacing-induced cardiomyopathy (PICM). AIM: The aim of this study was to compare the incidence of PICM based on the location of implantation of LP. METHODS: A total of 358 consecutive patients [women: 171 (48%), mean age: 73 ± 15 years] with left ventricular ejection fraction (EF) > 50%, who received an LP (Micra) between January 2017 and June 2022, formed the study cohort. Micra-AV and Micra-VR were implanted in 122 (34%) and 236 (66%) patients, respectively. Fluoroscopically, the location of implantation of LP in the interventricular septum (IS) was divided into two equal halves (apex/apical septum [AS] and mid/high septum [HS]). During follow-up, PICM was defined as an EF drop of ≥10%. RESULTS: LP was implanted in 109 (34%) and 249 (66%) patients at AS and HS locations, respectively. During a mean 18 ± 8 months follow-up, 28 patients (7.8%) developed PICM. Among the 249 patients with HS placement of LP, 10 (4%) developed PICM, whereas among the 109 patients with AS placement of LP, 18 (16.5%) developed PICM (p = .002). AS location was associated with a higher risk of PICM compared to HS locations (adjusted hazard ratio: 4.42, p < .001). CONCLUSION: AS location of LP was associated with a higher risk of PICM compared to HS placement. Larger randomized studies are needed to confirm our findings.


Assuntos
Cardiomiopatias , Marca-Passo Artificial , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Pessoa de Meia-Idade , Cardiomiopatias/diagnóstico , Cardiomiopatias/terapia , Cardiomiopatias/epidemiologia , Marca-Passo Artificial/efeitos adversos , Volume Sistólico , Função Ventricular Esquerda
13.
Europace ; 2023 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-37184436

RESUMO

AIMS: No prior study has been adequately powered to evaluate real-world safety outcomes in those receiving adjunctive ablation lesions beyond pulmonary vein isolation (PVI). We sought to evaluate characteristics and in-hospital complications among patients undergoing PVI with and without adjunctive lesions. METHODS AND RESULTS: Patients in the National Cardiovascular Data Registry AFib Ablation Registry undergoing first-time atrial fibrillation (AF) ablation between 2016 and 2020 were identified and stratified into paroxysmal (PAF) and persistent AF, and separated into PVI only, PVI + cavotricuspid isthmus (CTI) ablation, and PVI + adjunctive (superior vena cava isolation, coronary sinus, vein of Marshall, atypical atrial flutter lines, other). Adjusted odds of adverse events were calculated using multivariable logistic regression. A total of 50 937 patients [PAF: 30 551 (60%), persistent AF: 20 386 (40%)] were included. Among those with PAF, there were no differences in the adjusted odds of complications between PVI + CTI or PVI + adjunctive when compared with PVI only. Among persistent AF, PVI + adjunctive was associated with a higher risk of any complication [3.0 vs. 4.5%, odds ratio (OR) 1.30, 95% confidence interval (CI) 1.07-1.58] and major complication (0.8 vs. 1.4%, OR 1.56, 95% CI 1.10-2.21), while no differences were observed in PVI + CTI compared with PVI only. Overall, there was high heterogeneity in adjunctive lesion type, and those receiving adjunctive lesions had a higher comorbidity burden. CONCLUSION: Additional CTI ablation was common without an increased risk of complications. Adjunctive lesions other than CTI are commonly performed in those with more comorbidities and were associated with an increased risk of complications in persistent AF, although the current analysis is limited by high heterogeneity in adjunctive lesion set type.

15.
JACC Clin Electrophysiol ; 9(4): 555-564, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-37014289

RESUMO

BACKGROUND: Inpatient initiation of sotalol is recommended owing to its proarrhythmic effects. OBJECTIVES: The DASH-AF (Feasibility and Safety of Intravenous Sotalol Administered as a Loading Dose to Initiate Oral Sotalol Therapy in Adult Patients With Atrial Fibrillation) trial evaluates the safety and feasibility of intravenous (IV) sotalol, achieving a steady state with maximum QTc prolongation within 6 hours instead of the traditional 5-dose inpatient oral (PO) titration. METHODS: DASH-AF is a prospective, nonrandomized, multicenter, open-label trial consisting of patients who underwent IV sotalol loading dose to initiate rapid oral therapy for atrial arrhythmias. IV dose was calculated based on the target oral dose as indicated by baseline QTc and renal function. Patients' QTc (in sinus) was measured via electrocardiography at 15-minute intervals and after IV loading completion. Patients were discharged 4 hours after first oral dose. All patients were monitored via mobile cardiac outpatient telemetry for 72 hours. The control group was composed of patients admitted for the traditional 5 PO doses. Safety outcomes were assessed in both groups. RESULTS: A total of 120 patients from 3 centers were enrolled from 2021 to 2022 in the IV loading group (compared with type of AF- and renal function-matched patients in the conventional PO loading cohort). This study demonstrated no significant change in ΔQTc in both groups, with a significantly lower number of patients requiring dose adjustment in the IV arm compared with the PO arm (4.1% vs 16.6%; P = 0.003). This led to potential cost savings of up to $3,500.68 per admission. CONCLUSIONS: The DASH-AF trial shows that rapid IV sotalol loading in atrial fibrillation/flutter patients for rhythm control is feasible and safe compared with conventional oral loading with significant cost reduction. (Feasibility and Safety of Intravenous Sotalol Administered as a Loading Dose to Initiate Oral Sotalol Therapy in Adult Patients With Atrial Fibrillation [DASH-AF]; NCT04473807).


Assuntos
Fibrilação Atrial , Sotalol , Humanos , Adulto , Sotalol/efeitos adversos , Antiarrítmicos/efeitos adversos , Estudos Prospectivos , Estudos de Viabilidade
16.
J Interv Card Electrophysiol ; 66(9): 2165-2175, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37106267

RESUMO

BACKGROUND: Leadless pacemakers (LP) and transvenous pacemakers (TVP) are two stable pacing platforms currently available in clinical practice. Observational data show mixed results with regards to their comparative safety. This meta-analysis was aimed to evaluate the comparative safety of LP over TVP. METHODS: The study protocol was registered in PROSPERO registry (CRD42022325376). Six databases were searched for published literature from inception to April 12, 2022. RevMan 5.4.1 was used for statistical analysis. Odds ratio (OR) and mean difference were used to estimate the outcome with a 95% confidence interval (CI). RESULTS: A total of 879 studies were imported from the databases. Among these, 41 papers were screened for full text and 17 meet the inclusion criteria. Among them, pooled results showed 42% lower odds of occurrence of complications in the LP group (OR 0.58, CI 0.42-0.80) compared to TVP group. Notably, 70% lower odds of device dislodgment (OR 0.30, CI 0.21-0.43), 46% lower odds of re-intervention (OR 0.54, CI 0.45-0.64), 87% lower odds of pneumothorax (OR 0.13, CI 0.03-0.57), albeit, 2.65 times higher odds of pericardial effusion (OR 2.65, CI 1.49-4.70) were observed in the LP group. CONCLUSIONS: This meta-analysis showed LP to be a significantly safer modality compared to TVP, in terms of re-intervention, device dislodgment, pneumothoraxes, and overall complications. However, there were higher rates of pericardial effusion in the LP group. There was a diverse number of patients included, and all studies were observational. Randomized trials are needed to validate our findings.


Assuntos
Marca-Passo Artificial , Derrame Pericárdico , Humanos , Desenho de Equipamento , Sistema de Registros , Resultado do Tratamento , Estimulação Cardíaca Artificial/métodos
20.
JACC Cardiovasc Interv ; 15(21): 2158-2170, 2022 11 14.
Artigo em Inglês | MEDLINE | ID: mdl-36357020

RESUMO

BACKGROUND: Incomplete left atrial appendage (LAA) closure is an evolving topic of clinical significance and thromboembolic potential, with recent long-term studies suggesting lower cutoffs for relevant leak size. OBJECTIVES: The aim of this prospective observational study was to assess 3 different closure techniques for persistent peridevice leaks after incomplete LAA closure and compare their efficacy and safety outcomes. METHODS: We studied 160 patients (mean age 72 ± 9 years; 71% men) who underwent 1 of the 3 available modalities (detachable embolization coils, vascular plugs or septal occluders, and radiofrequency ablation) for residual central or eccentric leak closure. Both acute postprocedural success (closure or <1-mm leak at the end of the procedure) and closure at 1-year follow-up transesophageal echocardiography imaging were evaluated. RESULTS: Of 160 patients, 0.6%, 41.3%, and 58.1% had mild (1-2 mm), moderate (3-5 mm), and severe (≥5 mm) leaks, respectively. Baseline LAA closure type was 72.5% Watchman FLX, 16.3% Lariat, 5.6% surgical ligation, 1.9% AtriClip, and 1.9% Amulet. Successful closure (0- or <1-mm leak) was seen in 100% of patients in all cohorts following intervention, with overall complete closure (0-1 mm) or mild or minimal leaks (1-2 mm) on 1-year follow-up transesophageal echocardiography seen in 100% of the atrial septal occluder or vascular plug cohort, 85.9% of the coil cohort, and 83.3% of the radiofrequency ablation cohort (P < 0.001). Two patients (1.3%) experienced cardiac tamponade, and there were no deaths or other complications. CONCLUSIONS: Peridevice leaks can safely and effectively be closed using 3 different modalities depending on size and location.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Dispositivo para Oclusão Septal , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/terapia , Fibrilação Atrial/complicações , Resultado do Tratamento , Ecocardiografia Transesofagiana , Cateterismo Cardíaco/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...