1.
Europace ; 3(4): 317-23, 2001 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11678391

RESUMO

AIMS: This report describes the initial clinical results with a newly designed guiding catheter and an 'over the wire' pacing lead based on angiolasty technology to stimulate the left ventricle using the transvenous route via the coronary sinus (OTW-CV lead). METHODS AND RESULTS: In 75% of the 15 patients (6 males, 9 females, mean age of 53 +/- 9 years) with congestive heart failure, access to coronary sinus required less than 2 min; in one patient. the attempt failed. Mean R wave amplitudes plus or minus the standard deviation, measured at apical, mid-ventricular and basal positions the anterior (11.4 +/- 9.2, 10.8 +/- 6.2, 9.3 +/- 6.3 mV) and lateral or posterior veins (10.1 +/- 10.7, 8.6 +/- 6.4, 7.7 +/- 4.3 mV) showed a trend favouring the apex without statistical significance. Pacing impedance, measured at the same sites and vein tributaries, ranged from 670 +/- 191 to 915 +/- 145 ohms. Pacing thresholds measured at apical and mid ventricular sites were significantly lower than at the base in the anterior vein 2.5 +/- 2.8 and 2.8 +/- 1.8 vs 5.6 +/- 2.7 V at 0.5 ms, P<0.001). Thresholds in the lateral/posterior veins showed a similar trend but did not reach statistical significance (3.0 +/- 1.7, 3.6 +/- 1.4 +/- 1.8 V at 0.5 ms). In patients, in whom thresholds were determined in more than one vein, the 'best' mean threshold was 1.6 +/- 0.7 V. CONCLUSION: The new 'over the wire' lead and guiding catheter system allows uncomplicated access to the coronary sinus and the depth of the coronary vein tributaries. Left ventricular sensing and pacing thresholds are acceptable for chronic use in implanted cardiac rhythm management systems.


Assuntos
Estimulação Cardíaca Artificial/métodos , Insuficiência Cardíaca/terapia , Marca-Passo Artificial , Adulto , Cateterismo Cardíaco , Vasos Coronários/anatomia & histologia , Eletrodos Implantados , Desenho de Equipamento , Feminino , Ventrículos do Coração , Humanos , Masculino , Pessoa de Meia-Idade
2.
Acta Anaesthesiol Scand ; 42(6): 717-20, 1998 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-9689280

RESUMO

BACKGROUND: Pressure measuring systems using fluid-filled catheters can result in the recording of distorted pressure waveforms. It results in phase delay, overestimation of systolic and, to a lesser extent, of diastolic pressure. We designed and evaluated a method to correct this pressure waveform distortion using an appropriate transfer equation obtained from the dynamic response of the fluid-filled catheter. This transfer equation is based on the principle that a fluid-filled catheter recording system is considered as an underdamped dynamic system fully characterized by its natural frequency (omega n) and damping ratio (zeta). METHODS: Pressure waveforms, simultaneously recorded in vitro or in vivo by a fluid-filled catheter (Pc) and a micromanometer-tipped catheter (Pref), were used to validate the method. Dynamic response of the catheter used was obtained from a fastflush test. The corrected signal (Ppred) was obtained using omega n, zeta and the following transfer equation: d2Pc/dt2 + 2 omega n zeta dPc/dt + omega n 2Pc = C Ppred (t) After correction of Pc, Ppred was compared, using a linear regression, with Pref taken as reference. RESULTS: Our results showed that Ppred was fitted to Pref with excellent coefficient correlation (0.99). The mean error and the standard error of estimate were respectively -1.16 mmHg and 1.4 mmHg. CONCLUSION: This new method can convert the distorted pressure waveforms transmitted by any fluid-filled catheters into high-fidelity signals. It suppresses the phase delay and the over-estimation of systolic pressure induced by fluid-filled catheters.


Assuntos
Determinação da Pressão Arterial/métodos , Cateterismo Periférico/instrumentação , Animais , Determinação da Pressão Arterial/instrumentação , Interpretação Estatística de Dados , Suínos
3.
Cardiovasc Res ; 38(2): 375-82, 1998 May.
Artigo em Inglês | MEDLINE | ID: mdl-9709398

RESUMO

OBJECTIVE: We tested the hypothesis that right heart failure during endotoxin shock may result from altered ventriculovascular coupling responsible for impeding power transfer to the pulmonary circulation. METHODS: The changes in vascular pulmonary input impedance and right ventricular contractility produced by low-dose endotoxin infusion were studied in 6 intact anesthetized dogs. RESULTS: Endotoxin insult resulted in pulmonary hypertension (from 22 +/- 2 to 33 +/- 3 mmHg) associated with significant decreases in stroke volume (from 26.9 +/- 4 to 20.2 +/- 3 ml) and right ventricular ejection fraction (from 41 +/- 3 to 32 +/- 2%). The first minimum of input impedance spectrum and zero phase were shifted towards higher frequencies. Input resistance and characteristic resistance were dramatically increased. The latter change contributed to a significant increase in the pulsatile component of total right ventricular power output from 13 to 21%, indicating a reduction in the hydraulic right ventricle power output delivered into the main pulmonary artery. Overall changes in input pulmonary impedance were indicative of increased afterload facing the right ventricle leading to depressed performance. In contrast, right ventricular systolic elastance was simultaneously increased from 0.56 to 0.93 mmHg/ml indicating an increase in right heart contractility. CONCLUSION: These data suggest that pulmonary hypertension in the setting of experimental endotoxin shock is accompanied by deleterious changes in the pulmonary impedance spectrum, which are responsible for a mismatch of increased contractile state of the right ventricle to the varying hydraulic load ultimately leading to ventricular-vascular uncoupling.


Assuntos
Endotoxinas/farmacologia , Hipertensão Pulmonar/induzido quimicamente , Choque Séptico/fisiopatologia , Disfunção Ventricular Direita/induzido quimicamente , Análise de Variância , Animais , Cães , Hemodinâmica/efeitos dos fármacos , Hipertensão Pulmonar/fisiopatologia , Circulação Pulmonar/efeitos dos fármacos , Fluxo Sanguíneo Regional/efeitos dos fármacos , Resistência Vascular/efeitos dos fármacos , Disfunção Ventricular Direita/fisiopatologia
4.
Arch Physiol Biochem ; 105(7): 625-32, 1997 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-9693708

RESUMO

In 11 anaesthetised pigs the accuracy of the three-element (WK3) and the four-element (WK4) Windkessel models to describe hemodynamic properties of the pulmonary circulation was compared during six different experimental conditions increasing pulmonary arterial pressure: increase in left atrial pressure, increase in alveolar pressure, increase in pulmonary blood flow, endotoxin shock, mechanical obstruction of left pulmonary artery or histamine infusion. Our results showed that WK4 fitted better the data than did WK3 because values of 1-R2 decreased from 6 percent (WK3) to 1.4 percent (WK4) when WK4 was used (P < 0.0005). 1-R2 was an adequate marker of the accuracy of the linear regression used to solve equations of both models. Compliance values estimated by WK4 were decreased by 5% comparatively to WK3 (P = 0.008). However, this difference can be considered as not physiologically relevant. Values of characteristic resistance corresponding to R1 + (L/R2C) in WK4 and to R1 in WK3 were not different (P = 0.22). The relative changes in R1, R2, and C observed due to the different experimental conditions were comparable regardless of the model. In conclusion, the conversion of WK3 in WK4 by adding an inductance, whose physiological meaning is not clear, resulted in an increased statistical accuracy of the model, but did not seem to have relevant influence on parameters or their evolution during experimental conditions.


Assuntos
Hemorreologia , Modelos Biológicos , Circulação Pulmonar , Animais , Arteriopatias Oclusivas/fisiopatologia , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea/efeitos dos fármacos , Feminino , Átrios do Coração , Histamina/farmacologia , Masculino , Matemática , Respiração com Pressão Positiva , Alvéolos Pulmonares/fisiologia , Artéria Pulmonar , Circulação Pulmonar/efeitos dos fármacos , Choque Séptico/fisiopatologia , Suínos