Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
Neuroradiol J ; 34(3): 205-212, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33417503

RESUMO

BACKGROUND: Brain metastasis and glioblastoma multiforme are two of the most common malignant brain neoplasms. There are many difficulties in distinguishing these diseases from each other. PURPOSE: The purpose of this study was to determine whether the mean apparent diffusion coefficient and absolute standard deviation derived from apparent diffusion coefficient measurements can be used to differentiate glioblastoma multiforme from brain metastasis based on cellularity levels. MATERIAL AND METHODS: Magnetic resonance images of 34 patients with histologically verified brain tumors were evaluated retrospectively. Apparent diffusion coefficient and standard deviation values were measured in the enhancing tumor, peritumoral region, and contralateral healthy white matter. Then, to determine whether there was a statistical difference between brain metastasis and glioblastoma multiforme, we analyzed different variables between the two groups. RESULTS: Neither mean apparent diffusion coefficient values and ratios nor standard deviation values and ratios were significantly different between glioblastoma multiforme and brain metastasis. Receiver operating characteristic curve analysis of the logistic model with backward stepwise feature selection yielded an area under the curve of 0.77, a specificity of 84%, a sensitivity of 67%, a positive predictive value of 83.33%, and a negative predictive value of 78.26% for distinguishing between glioblastoma multiforme and brain metastasis. The absolute standard deviation and standard deviation ratios were significantly higher in the peritumoral edema compared to the tumor region in each case. CONCLUSION: Apparent diffusion coefficient values and ratios, as well as standard deviation values and ratios in peritumoral edema, cannot be used to differentiate edema with infiltration of tumor cells from vasogenic edema. However, standard deviation values could successfully characterize areas of peritumoral edema from the tumoral region in each case.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Glioblastoma/diagnóstico por imagem , Glioblastoma/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
2.
Physiother Res Int ; 25(3): e1843, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32343035

RESUMO

OBJECTIVES: The effects of different physiotherapy protocols on patients suffering from grade-I spondylolisthesis have been thus far examined in a limited number of clinical trials. Therefore, the main purpose of this study was to compare the effects of lumbar segmental stabilization and general exercises on clinical and radiologic criteria in grade-I spondylolisthesis patients. METHODS: This study was a double-blind randomized controlled trial (RCT) with a test-retest design and parallel groups. A total of 26 patients with grade-I spondylolisthesis were thus randomly assigned to experimental group (13 patients, lumbar segmental stabilization exercises) and control group (13 patients, general exercises). Subsequently, pain, functional disability, kinesiophobia, translational motion, angular motion and slip percentage of the vertebra were investigated. RESULTS: Of the 120 people recruited in this study, only 26 patients were eligible. According to pre/post-intervention comparison, a statistically significant decrease was observed in the experimental group in terms of pain (p = 0.000), functional disability (p = 0.004), kinesiophobia (p = 0.002), translational motion (p = 0.043) and angular motion (p = 0.011), but not for slip percentage (p = 0.122). Considering the control group, a statistically significant decline was reported for pain (p = 0.043) and functional disability (p = 0.002). However, no significant differences were found for other variables in the control group. With regard to inter-group comparison, there was no statistically significant difference between the two groups regarding the given variables except for kinesiophobia (p = 0.040). CONCLUSION: Both lumbar segmental stabilization and general exercises led to reduction in pain and functional disability of patients with grade-I spondylolisthesis. Therefore, lumbar segmental stabilization exercises seemed to be better than general ones with reference to improving kinesiophobia and intervertebral movements.


Assuntos
Terapia por Exercício/métodos , Vértebras Lombares/fisiopatologia , Amplitude de Movimento Articular/fisiologia , Espondilolistese/reabilitação , Adulto , Método Duplo-Cego , Feminino , Humanos , Região Lombossacral/fisiopatologia , Masculino , Pessoa de Meia-Idade , Medição da Dor , Resultado do Tratamento
4.
Medicina (Kaunas) ; 55(7)2019 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-31336780

RESUMO

Background and Objectives: The brain imaging of the pituitary gland in females has shown a change in pituitary size and volume in the female's population. It has been proven that the pituitary gland is affected by pregnancy, giving birth, and hormone-related factors. Therefore, this study aimed to evaluate the factors which may have an impact on the pituitary size in females at reproductive age and compare the pituitary size in females with a history of pregnancy, those at the postpartum period, and nullipara females. Materials and Methods: This population-based study was conducted on 208 healthy women aged 12-55 years old. Participants underwent cranial Magnetic resonance imaging (MRI), and pituitary diameters (craniocaudal, anteroposterior, and transverse) and volume were measured for each subject. The correlation of age, gravity, parity, lactation, and intake of oral contraceptives with pituitary size were analyzed. Results: One-hundred and eighty females met the criteria for participation. The pituitary volume correlated negatively with hormone-related factors. The gravity (r = -0.35) and parity (r = -0.35) had significant negative effects on the pituitary volume (p < 0.001). The use of oral contraceptives and lactation were also in negative correlation with the pituitary volume (r = -0.20, p = 0.006, r = -0.56, p < 0.001, respectively). The craniocaudal diameter was also affected by gravity (r = -0.62), parity (r = -0.57), intake of contraceptives (r = -0.32), and lactation (r = -0.70), p < 0.001. The anteroposterior diameter of the pituitary gland associated significantly with gravity (r = -0.19, p = 0.009), parity (r = -0.20, p = 0.007), and lactation (r = -0.25, p = 0.001). The transverse diameter of the pituitary gland also related negatively with reproductive factors such as gravity (r = -0.15, p = 0.04), parity (r = -0.17, p = 0.02), and lactation (r = -0.17, p = 0.02). The pituitary gland of nullipara females was the greatest in size. Recent pregnancy led to increased craniocaudal and anteroposterior diameters. Conclusions: In this study, we found a negative effect of pregnancy and giving birth on pituitary size. Nullipara females were found to have the greatest pituitaries, even greater than the females in the postpartum period.


Assuntos
Fatores Etários , Hipófise/patologia , Saúde Reprodutiva/normas , Pesos e Medidas/normas , Adolescente , Adulto , Criança , Feminino , Humanos , Pessoa de Meia-Idade , Hipófise/fisiopatologia , Gravidez , Pesos e Medidas/instrumentação
5.
Curr Med Imaging Rev ; 15(10): 922-932, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-32008520

RESUMO

BACKGROUND: Scoliosis is a three-dimensional deformity of the spine. It is usually assessed by measuring Cobb angle. Nowadays, due to increasing effectiveness of image processing and machine vision, willingness to apply these methods has improved considerably in determining scoliosis of Cobb angle. METHODS: In accordance with the PRISMA guideline, a broad electronic search of all English language literature was conducted on the topic through four databases, including MEDLINE, Web of Science, Scopus, and the Cochrane Library from 2012 (last search date from earlier review) to 30 March 2017. RESULTS: Twelve studies were included. 90% labeled high-quality were selected for analysis. Eighty percent of the selected studies were published in the period between 2012 and 2017. Three new procedures were used to measure the Cobb angle. One study used automated procedure (7%), two studies used smartphone procedure (14%), and nine studies used the semiautomatic procedure of Cobb measurement (79%). Seven studies reported reproducibility and repeatability. Reproducibility range was 0.72 to 1 in reporting of ICC. Repeatability has a high range in three separated methods. CONCLUSION: Computerized assessment method (Automatic and Semi-automatic) is most commonly performed in Cobb measurement. Semi-automatic is an effective measurement option for computerized assessment Cobb angle. There is no significant difference between manual, computer- based, and smartphone-based methods in described measures.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Escoliose/diagnóstico por imagem , Coluna Vertebral/diagnóstico por imagem , Viés , Sistemas de Apoio a Decisões Clínicas , Progressão da Doença , Humanos , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Radiografia/métodos , Reprodutibilidade dos Testes , Smartphone/estatística & dados numéricos
6.
Niger Med J ; 57(6): 353-356, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27942104

RESUMO

BACKGROUND: Cognitive disorders and dementia are common problems, and Alzheimer's disease is one of the major leading causes of death worldwide. Thyroid hormone disorders as a common problem effect on hippocampus size which as a prognostic factor in dementia. The aim of the present study was to investigate the relationship between serum thyroid-stimulating hormone (TSH) level and the size of hippocampus in patients with mild cognitive disorders. MATERIALS AND METHODS: In a descriptive-analytical study, 41 patients with symptoms of mild cognitive disorders whom referred to take the brain magnetic resonance image (MRI) in a radiology center under the direction of Tabriz University of Medical Sciences (Tabriz, Iran) were evaluated. The right and left hippocampal and brain volume was calculated by MRI at coronal T1-weighted. Serum TSH level was also measured in these patients. Correlation between serum TSH level and hippocampal volume size was evaluated. RESULTS: Male to female ratio was 1.05:1 with mean age of 54.09 ± 3.11 years. Mean serum TSH level of patients was 1.55 ± 1.45 uU/ml. The right and left hippocampal volumes were 1.61 ± 0.42 and 1.62 ± 0.39 ml, respectively. There were slight negative correlations between the right and left hippocampal volumes with TSH level (r = -0.133 and r = -0.092, respectively). Correlations between the right and left hippocampal volumes with TSH level were not statistically significant (P = 0.406, P = 0.566, respectively). CONCLUSION: Based on findings of the present study, there was a weak negative correlation between serum level of TSH with the right and left hippocampal and brain volume ratio, but the correlation was not statistically significant. It seems that controlling of clinical or subclinical hypothyroidism may have a role in slowing of dementia progression and also have a preventive role.

7.
Br J Radiol ; 89(1066): 20150152, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27452260

RESUMO

OBJECTIVE: To examine the effect of using different b-values on the utility of diffusion-weighted (DW) MRI in differentiating acute infectious spondylitis from Modic type 1 and the discriminative accuracy of related apparent diffusion coefficient (ADC), claw-sign and amorphous increased signal. METHODS: 43 patients with equivocal diagnosis of acute infectious spondylitis/Modic type 1 by using MR images were prospectively studied. The discriminative accuracy of DW MRI using three b-values of 50, 400, 800 s mm(-2), ADC, claw sign and amorphous increased signal was examined. RESULTS: DW MRI differentiated infectious spondylitis from Modic type 1 change most accurately when a b-value of 800 s mm(-2) was chosen [sensitivity, 91.7%; specificity, 96.8%; positive-predictive value (PPV), 91.7%; negative-predictive value (NPV), 96.8%; and accuracy, 95.3%]. The optimal cut-off ADC value was 1.52 × 10(-3) mm(2) s(-1) (sensitivity, 91.7%; specificity, 100%; PPV, 100%; NPV, 96.9%; and accuracy, 97.7%). Best visualized at a b-value of 50 s mm(-2), claw sign (for degeneration) and amorphous increased signal (for infection) were 100% accurate. CONCLUSION: Should DW MRI be used in differentiating acute infectious spondylitis from degeneration, large b-values are required. With low b-values, however, claw sign and amorphous increased signal are very accurate in this regard. ADVANCES IN KNOWLEDGE: DW MRI using large b-values could be used in differentiating acute infectious spondylitis from Modic type I.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Espondilite/diagnóstico por imagem , Espondilite/patologia , Adulto , Idoso , Diagnóstico Diferencial , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Biópsia Guiada por Imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tomografia Computadorizada por Raios X
8.
Acta Neurochir (Wien) ; 158(3): 473-9, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26782826

RESUMO

BACKGROUND: Because of a degenerative component, degenerative rotatory scoliosis seems different from congenital and idiopathic subtypes of the disease. This study aims to examine the orientation of facet joints, as a known cause of degeneration, in patients with degenerative rotatory scoliosis. METHODS: Lumbar magnetic resonance (MR) images and plain radiographs of 52 symptomatic patients (mean age, 50.17 years) with degenerative rotatory lumbar scoliosis (mean curve, 19.22 degrees) and 50 healthy individuals were reviewed. Facet joint angles in rotated segments and the minimum neural foramen width at all lumbar levels were measured by three observers and the average was recorded. RESULTS: The maximum vertebral rotation was most frequent at L4-L5 (75 %), and the majority was of type I (84.6 %) according to the Nash-Moe classification. At all lumbar spinal levels the mean facet joint angles were significantly higher on the side of rotation (L2-L3, 57.92 degrees; L3-L4, 45.00 degrees; L4-L5, 43.88 degrees) compared to those on the contralateral side (L2-L3, 20.42 degrees; L3-L4, 15.48 degrees; L4-L5, 13.12 degrees) and in controls (L2-L3, 30.21 degrees; L3-L4, 40.81 degrees; L4-L5, 45.20 degrees) (p < 0.001 for all comparisons). The mean facet joint angle increased significantly from L4-L5 to L2-L3 in cases and reversely in controls. The mean minimum neural foramen width was 1.29 ± 0.85 mm on the side of rotation, 5.50 ± 1.09 mm on the contralateral side, and 6.78 ± 1.75 mm in controls (p < 0.001). CONCLUSIONS: Substantial asymmetries and abnormal orientations in facet joints were documented in patients with degenerative rotatory lumbar scoliosis. Such asymmetries may adversely affect neural foramen width.


Assuntos
Escoliose/patologia , Articulação Zigapofisária/patologia , Adulto , Índice de Massa Corporal , Estudos de Casos e Controles , Estudos Transversais , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Degeneração do Disco Intervertebral/patologia , Região Lombossacral/patologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Rotação
9.
Iran J Radiol ; 12(4): e11905, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26715977

RESUMO

BACKGROUND: Failed visualization of the fetal nasal bone (NB) by ultrasound at 11 - 14 weeks of gestation is strongly associated with chromosomal abnormalities. Meanwhile, the incidence of the absent fetal NB in normal fetuses in the first trimester in mothers of different ethnic origins differs significantly. It is, therefore, important to assess ethnic variations in the first-trimester visualization of the fetal NB before introducing this marker into routine screening programs for aneuploidy. OBJECTIVES: The objectives of this study were to determine the NB length and the prevalence of the NB absence as well as calculating the likelihood ratio (LR) for the absence of the NB in normal fetuses of Iranian women undergoing first-trimester screening for trisomy 21. PATIENTS AND METHODS: In 767 normal fetuses, the fetal profile was examined by ultrasound for the absence/presence of the NB. The NB length was also measured, and the LR for the NB absence was also determined. RESULTS: The NB was absent in 2/767 (0.26%) of the fetuses. The mean length of the NB was 3.6 ± 0.69 mm for the fetuses of 11 - 14 weeks gestational age. The LR value of the absent NB was equal to 250 in the normal fetuses of the Iranian population living in the North-West provinces. CONCLUSION: The low prevalence of the NB absence in normal fetuses in the present study is compatible with the larger size of the NB in Iranian people compared to other communities. Meanwhile, the reference range of the NB length in normal Iranian fetuses was established so that basic data could be recorded for further studies regarding the absence or presence of the NB in screening for chromosomal abnormalities (Down syndrome) within the Iranian population.

10.
Eur Spine J ; 24(10): 2315-20, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26071946

RESUMO

PURPOSE: The purpose of this study was to evaluate magnetic resonance (MR)-detected redundant nerve roots (RNRs) of the cauda equina in patients with lumbar spinal canal stenosis. METHODS: A total of 500 lumbar MR studies in patients with lumbar spinal canal stenosis were reviewed for the presence and characteristics of RNRs of the cauda equina. The length of the RNRs relative to the height of the upper vertebral body of the level of the stenosis was used as a prognostic indicator. RESULTS: RNRs were detected in 15% of the patients, the majority above the level of the stenosis (85%) and loop shaped (72%). Advanced age (i.e., ≥56 years old, odds ratio=1), a lumbar spinal canal stenosis at L2-4 (odds ratio=2.5), and the presence of an intracanal protuberance with sharp margin in the site of the stenosis (odds ratio=7.2) were independent risk factors for the development of RNRs. A direct, significant correlation was found between the relative length of the RNRs and patients' age (Pearson r=0.36, p=0.001). The mean relative length of the RNRs was significantly higher in patients with RNRs located above the level of the stenosis than those with RNRs located below the site of the block. The degree of stenosis was associated with neither the presence nor the relative length of the RNRs. CONCLUSIONS: With an occurrence rate of 15%, RNRs of the cauda equina are not uncommon in cases with lumbar spinal canal stenosis. Advanced age, a canal stenosis at L2-4, and the presence of a sharp intracanal protuberance in the site of the stenosis are the related risk factors. Patients' age and the location of RNRs may be of prognostic value.


Assuntos
Cauda Equina , Vértebras Lombares/patologia , Imageamento por Ressonância Magnética , Estenose Espinal/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Cauda Equina/patologia , Cauda Equina/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
11.
Acta Med Iran ; 53(4): 250-5, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25871025

RESUMO

We report a patient diagnosed with Whipple's disease (WD) who presented only with neurological symptoms. Neuroimaging (MRI) showed lesions with marked mass effect similar to infiltrative tumors, which were hypersignal on long TR and hyposignal on short TR images, located in several areas of the brain. In serial controls, lesions resolved with gliosis and atrophic changes as well as migration of active infiltrative-like lesions to new areas. MR findings of the brain WD are discussed, which confirmed by stereotactic brain biopsy. Familiarity with the range of possible MR imaging appearances of WD enables the radiologist to place WD more effectively on the differential diagnosis which motivates the clinician to consider both the diagnosis and early initiation of treatment; so, this may significantly impact outcome. Moreover, repeated MR investigations may serve as a valuable method to evaluate efficacy of treatment and long term follow-up of WD involving the CNS.


Assuntos
Encefalopatias/diagnóstico , Imageamento por Ressonância Magnética/métodos , Doença de Whipple/diagnóstico , Adulto , Atrofia , Biópsia , Encéfalo/fisiopatologia , Encefalopatias/fisiopatologia , Diagnóstico Diferencial , Feminino , Humanos , Doença de Whipple/fisiopatologia
12.
Eur J Radiol ; 84(5): 921-6, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25715663

RESUMO

OBJECTIVES: To compare the degree of slip in spondylolisthesis on supine magnetic resonance (MR) images obtained with flexed and straightened lower extremities. METHODS: Supine spinal MR studies were performed in 100 cases of symptomatic spondylolisthesis with flexed and then straightened lower extremities. The angle of lumbar lordosis (by Cobb's method) and the degree of slip (by Taillard's method) were compared between the two sets of images. RESULTS: The mean angle of lumbar lordosis increased from 51.65±8.57° on MR images with flexed lower limbs to 57.39±9.05° on MR images with straightened lower limbs (p<0.001; mean percent increase: 11.51%). Similar change was also observed for the mean degree of slip (from 25.80±7.74% to 28.68±7.93%, p<0.001; mean percent increase: 12.60%). After MR imaging with straightened lower extremities 22 out of 54 initially grade I cases had grade II disease (p<0.001). CONCLUSIONS: Supine magnetic resonance imaging with straightened lower extremities detects higher degree of slippage in symptomatic patients with spondylolisthesis compared to conventional MRI with flexed lower extremities.


Assuntos
Disco Intervertebral/patologia , Lordose/patologia , Vértebras Lombares/patologia , Imageamento por Ressonância Magnética , Espondilolistese/patologia , Decúbito Dorsal , Adulto , Feminino , Humanos , Lordose/fisiopatologia , Extremidade Inferior/patologia , Vértebras Lombares/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Espondilolistese/fisiopatologia , Suporte de Carga
13.
J Pediatr Endocrinol Metab ; 28(1-2): 117-23, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25153566

RESUMO

OBJECTIVES: Growth hormone deficiency (GHD) is a major problem among children with short stature. In this study, the role of brain magnetic resonance imaging (MRI) in defining the underlying defects among short children with GHD is evaluated. METHODS: In a cross-sectional study, data of 158 children were evaluated. Growth hormone (GH) levels were measured using stimulating tests and brain MRI with gadolinium contrast was applied, as well. RESULTS: Some 25.3% of patients had GHD with a mean age of 8.01±3.40 years. MRI results showed 35 as normal, four with pituitary hypoplasia, and one with microadenoma. The MRI results were significantly associated with GH levels and presence of other endocrine disorders. There was a significant association between prenatal disorders and patients' bone age delay. CONCLUSIONS: In patients with severe GHD and patients with multiple pituitary hormone deficiencies, MRI is more likely to be abnormal, and bone age is much delayed in patients with history of prenatal disorders.


Assuntos
Encéfalo/patologia , Nanismo Hipofisário/patologia , Transtornos do Crescimento/patologia , Hormônio do Crescimento Humano/deficiência , Hipopituitarismo/patologia , Imageamento por Ressonância Magnética , Adolescente , Determinação da Idade pelo Esqueleto , Estatura , Peso Corporal , Criança , Pré-Escolar , Estudos Transversais , Nanismo Hipofisário/complicações , Nanismo Hipofisário/diagnóstico , Feminino , Transtornos do Crescimento/complicações , Transtornos do Crescimento/diagnóstico , Humanos , Hipopituitarismo/complicações , Hipopituitarismo/diagnóstico , Masculino
14.
Asian Spine J ; 8(4): 405-11, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25187856

RESUMO

STUDY DESIGN: Case-control. PURPOSE: To determine whether a disproportion between two neighboring vertebral end plates is associated with degenerative disc disease. OVERVIEW OF LITERATURE: Recently, it has been suggested that disproportion of the end plates of two adjacent vertebrae may increase the risk of disc herniation. METHODS: Magnetic resonance (MR) images (n=160) with evidence of grades I-II lumbar degenerative disc disease (modified Pfirrmann's classification) and normal MR images of the lumbar region (n=160) were reviewed. On midsagittal sections, the difference of anteroposterior diameter of upper and lower end plates neighboring a degenerated (in the case group) or normal (in the control group) intervertebral disc was calculated (difference of end plates [DEP]). RESULTS: Mean DEP was significantly higher in the case group at the L5-S1 level (2.73±0.23 mm vs. 2.21±0.12 mm, p=0.03). Differences were not statistically significant at L1-L2 (1.31±0.13 mm in the cases vs. 1.28±0.08 mm in the controls, p=0.78), L2-L3 (1.45±0.12 mm in the cases vs. 1.37±0.08 mm in the controls, p=0.58), L3-L4 (1.52±0.13 mm in the cases vs. 1.49±0.10 mm in the controls, p=0.88), and L4-L5 (2.15±0.21 mm in the cases vs. 2.04±0.20 mm in the controls, p=0.31) levels. The difference at the L5-S1 level did not remain significant after adjusting for body mass index (BMI), which was significantly higher in the patients. CONCLUSIONS: End plate disproportion may be a significant, BMI-dependent risk factor for lumbar degenerative disc disease.

15.
Iran J Radiol ; 10(3): 185-7, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24348610

RESUMO

BACKGROUND: Normal morphological features of the maternal pelvis are an important prerequisite to vaginal delivery. OBJECTIVES: We aimed to evaluate the association between obstetric conjugate diameter (OCD) measured by ultrasonography and the type of delivery, vaginally (V) or by cesarean (C) section. PATIENTS AND METHODS: Pelvimetry was performed in 200 primigravid women for fetal cephalic presentation. The OCD was measured twice by transabdominal ultrasonography during 25-30 weeks and 30-35 weeks of pregnancy. RESULTS: The mean OCD of both sonographies in groups V and C was 125.51± 8.35 mm (105-144.5) and 112.99 ± 8.53 mm (96-134.5), respectively, which was significantly lower in group C (P<0.001). The values of OCD between the first and second measurements were not different significantly (P=0.065). C-section was indicated in 65 (32.5%) mothers. The optimal cut-off point for the OCD in the prediction of vaginal delivery was ≥ 119.75 mm, with a sensitivity and specificity of 80% and 78.5%, respectively. CONCLUSION: The US measurement of OCD might be an accurate method that almost always remains constant during late pregnancy; it is easy to measure and might be confidentially employed for predicting C-section, but needs more precise studies to be used widely.

16.
Acta Med Iran ; 51(8): 572-6, 2013 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-24026996

RESUMO

We present 16 years old girl with primary breast lymphoma involving the both breasts simultaneously and co-incidence of central nervous system (CNS) involvement which originated from the breast, in addition to evidence of lymphoma in multi-organ such as skin, mediastinum and some abdominal viscera. Bilaterality has been observed in some series, but reports are few and series are often very small. Radiologic features may be indistinguishable from those of the other breast malignancies, but it can be concluded that primary involvement of the breast with lymphoma should be considered when breast mass or inflammatory changes occur in a patient without any previously diagnosed lymphoma. The clinical behavior, imaging and therapeutic procedures are discussed. The findings of this report may have clinical impact on oncologists or that may alter the disease concept of bilateral breast lymphoma.


Assuntos
Neoplasias da Mama/diagnóstico , Linfoma não Hodgkin/diagnóstico , Metástase Neoplásica , Adolescente , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/fisiopatologia , Feminino , Humanos , Linfoma não Hodgkin/tratamento farmacológico , Linfoma não Hodgkin/fisiopatologia , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X
17.
Iran Red Crescent Med J ; 15(1): 18-20, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23486529

RESUMO

The development of inhibitors against administered clotting factors may render replacement therapy ineffective for some hemophilia patients. Such patients are therefore at the highest risk of developing arthropathy. Elective orthopedic surgery (EOS) in hemophilic patients having such inhibitors remains a rare, expensive, and difficult surgery, whose management represents a significant challenge. We report the case of a 35-year-old man with a severe form of hemophilia A (factor VIII < 1%), who was suffering from repetitive spontaneous hemarthrosis, especially in his knee joints that had consequently become more susceptible to bleeding. The patient had a history of high levels of factor VIII inhibitor (> 5.0 Bethesda Unit [BU]/ml) as shown by the factor VIII inhibitor assay; therefore, we began treatment with factor VIIa for his mild-to-moderate bleeding (90 µg/kg intravenous bolus injections). The interval between injections varied with the severity of the hemorrhage in each bleeding episode. The inhibitor level reduced to 3.1 BU/ml after three months, to 1.6 BU/ml after six months, and disappeared completely after one year of treatment. We administered factor VIII at a dose of 50 IU/kg every eight hours during the first three post-operative days, then continued administration with a dose of 40 IU/kg every 12 hours for another four days, and observed a very good response to treatment with no bleeding. Recombinant activated factor VII (rFVIIa) is not an inhibitor-removal strategy, but an inhibitor-bypassing product. However, in our patient, the treatment of mild-to-moderate bleeding with short-term use of rFVIIa and no exposure to factor VIII caused a gradual reduction in the inhibitor level over a period of 1 year.

18.
Iran J Radiol ; 10(1): 27-32, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23599710

RESUMO

BACKGROUND: MRI is not able to directly measure the concentration of contrast agent. It is measured indirectly from the signal intensity (SI). It is very important to know how much contrast agent should be injected to receive a maximum SI in the region of interest (ROI). OBJECTIVES: The aim of this study was to investigate the maximum relationship between contrast concentration and signal intensity (SI) on T1-weighted images using spin echo (SE), fast spin echo (FSE) and inversion recovery (IR) sequences. MATERIALS AND METHODS: To assess the relationship between SI and concentration, a water-filled phantom containing vials of different concentrations of gadolinium DTPA (Gd-DTPA) (0 to 19.77 mmol/L) or a constant concentration (1.2 mmol/L) of contrast agent was used. The vials of constant concentration were used to measure coil nonuniformity. The mean SI was obtained in the ROI using T1-weighted images. All studies were carried out using a 0.3 T clinical MR scanner with a standard head coil. RESULTS: This study shows that maximum SI will appear at different ranges in different sequences. The maximum SI can be seen at concentrations of 5.95, 4.96 and 3.98mmol/L for SE, FSE and IR, respectively. CONCLUSION: Using standard imaging parameters, each MRI sequence reaches its maximum SI in a specific contrast concentration, which is highest in SE and least in IR in a comparison between SE, FSE and IR sequences.

19.
Iran J Radiol ; 9(4): 223-6, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23408237

RESUMO

A patient with a 3-month history of headache refractory to pain medication was admitted. The CT scan and MRI showed evidence of a posterior fossa mass. This was pathologically confirmed as an extra medullary plasmacytoma (EMP). He had a pathologic fracture of the left humerus 7 years ago while the radiologist was unaware at the time of diagnosis. A solitary bone plasmacytoma (SBP) was the cause of the pathologic fracture. This report includes the first description of MRI findings in a patient with a rare-incidence intracranial solitary extra medullary plasmacytoma (SEP) in Iran. There is a striking similarity between the features of intracranial SEP and meningiomas. Intracranial SEP, although rare, should be included in the differential diagnosis of brain tumors in areas where meningiomas commonly arise. The MRI findings and differential diagnosis of plasmacytoma are reviewed. Before this case report, only few cases have been reported in the literature. Nonetheless, this is the first report of posterior fossa EMP from Iran.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...