Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Equine Vet J ; 52(3): 435-440, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31598997

RESUMO

BACKGROUND: Few noninvasive methods are available for equine hoof wall evaluation. The highly organised wall structures and composition of proteoglycans and collagens may make this region amenable to quantitative MRI (qMRI) techniques of T1ρ and T2 mapping to identify pathology related to proteoglycan content and collagen organisation respectively. OBJECTIVE: To establish normative T1ρ and T2 values of the equine hoof wall of 3-year-old Quarter Horses with histological comparison. STUDY DESIGN: Cadaveric anatomical study. METHODS: Six cadaveric left thoracic feet from 3-year-old racing Quarter Horses with no reported lameness were evaluated using T1ρ and T2 mapping. Mapping was performed at six regions of interest at the toe of each hoof including proximal and distal regions of the inner epidermis, stratum lamellatum and corium. Histology was evaluated for standard hoof morphology and proteoglycan staining. RESULTS: T2 values of the stratum lamellatum and corium were similar (42.9 [95% CI: 41.6-44.2] ms and 44 [95% CI: 42.7-45.3] ms respectively), but both were significantly different to the inner epidermis (35.8 [95% CI: 34.5-37.1] ms, P<0.001). T1ρ values for the inner epidermis, stratum lamellatum and corium were significantly different (25.1 [95% CI: 23.1-27.1] ms, 44.4 [95% CI: 42.4-46.4] ms and 50.1 [95% CI: 48.1-52.1] ms, respectively, P<0.001). Histology demonstrated normal organised morphology. Proteoglycan staining was only visible in the stratum lamellatum and corium. MAIN LIMITATIONS: Cadaveric study with frozen samples used. CONCLUSIONS: Variation of qMRI metrics through the depth of the equine hoof wall was found. Although the highly ordered environment of collagen may contribute to T2 values, there was lack of evidence to support proteoglycan content as a major contributor of T1ρ values. It is possible T1ρ values had a greater dependence on total water content as the lowest values were seen in the epidermis. Additional research using qMRI is needed to determine mapping values in different disease states.


Assuntos
Casco e Garras , Animais , Epiderme , Cavalos , Imageamento por Ressonância Magnética , Água
2.
Equine Vet J ; 48(3): 321-5, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-25627908

RESUMO

REASONS FOR PERFORMING STUDY: Post operative imaging in subjects with orthopaedic implants is challenging across all modalities. Magnetic resonance imaging (MRI) is preferred to assess human post operative musculoskeletal complications, as soft tissue and bones are evaluated without using ionising radiation. However, with conventional MRI pulse sequences, metal creates susceptibility artefact that distorts anatomy. Assessment of the post operative equine patient is arguably more challenging due to the volume of metal present, and MRI is often not performed in horses with implants. Novel pulse sequences such as multiacquisition variable resonance image combination (MAVRIC) now provide improved visibility in the vicinity of surgical-grade implants and offer an option for imaging horses with metal implants. OBJECTIVES: To compare conspicuity of regional anatomy in an equine fracture-repair model using MAVRIC, narrow receiver bandwidth (NBW) fast spin echo (FSE), and wide receiver bandwidth (WBW) FSE sequences. STUDY DESIGN: Nonrandomised in vitro experiment. METHODS: MAVRIC, NBW FSE and WBW FSE were performed on 9 cadaveric distal limbs with fractures and stainless steel implants in the third metacarpal bone and proximal phalanx. Objective measures of artefact reduction were performed by calculating the total artefact area in each transverse image as a percentage of the total anatomic area. The number of transverse images in which fracture lines were visible was tabulated for each sequence. Regional soft tissue conspicuity was assessed subjectively. RESULTS: Overall anatomic delineation was improved using MAVRIC compared with NBW FSE; delineation of structures closest to the metal implants was improved using MAVRIC compared with WBW FSE and NBW FSE. Total artefact area was the highest for NBW FSE and lowest for MAVRIC; the total number of transverse slices with a visible fracture line was highest in MAVRIC and lowest in NBW FSE. CONCLUSION: MAVRIC and WBW FSE are feasible additions to minimise artefact around implants.


Assuntos
Fraturas Ósseas/veterinária , Cavalos/lesões , Fixadores Internos/veterinária , Imageamento por Ressonância Magnética/veterinária , Aço Inoxidável , Animais , Cadáver , Fraturas Ósseas/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...