Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Poult Sci ; 98(9): 4016-4029, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-30953064

RESUMO

The influence of the grinding and physical form of diets on growth performance, gastrointestinal tract (GIT) development and nutrient digestibility was studied in layer pullets from hatch to 112 d of age. Diet formed a 2 × 2 factorial with 2 hammer mill screen sizes to grind cereals (4 and 8 mm) and 2 forms (mash and crumble). A total of 864 1-day-old layer chickens were randomly assigned to 1 of the 4 treatment groups with 8 replicates (27 birds per replicate). Cumulatively, pullets fed crumbles consumed less feed (P < 0.05) and had better feed conversion ratio (FCR; P < 0.01) than those fed mash. Coarse grinding cereals (CG) improved FCR (P < 0.05) without significant change in cumulative feed consumption compared to that of fine grinding (FG). With regard to body weight gain (BWG), pullets benefited from crumbles from 1 to 56 d of age (P < 0.01). There were interactions (P < 0.05) between screen size and feed form in relation to FCR (1 to 28 d) and overall BWG. At 112 d of age, the relative weight (RW, g/100 g body weight) of the crop, gizzard, pancreas, and liver of crumble-fed birds were lower (P < 0.05) than those for birds fed mash. Pullets fed coarsely ground feed had higher RW of the crop, proventriculus, gizzard, liver, and caecum compared to those fed finely ground feed. Compared to mash feeding, pullets fed crumbles increased (P < 0.05) total tract digestibility of ether extract and crude protein and the activities of pancreatic amylase and lipase. Digestibility of ether extract (P < 0.05) and pancreatic amylase activity (P < 0.01) were higher in birds fed a CG diet than in birds fed the FG regimen. Regarding the nutrition of egg-laying pullets, crumbles might be preferred to mash feed when the main objective is to improve FCR. Data also suggested that cereals used for pullet feed can be ground more coarsely than is in current practice.


Assuntos
Ração Animal/análise , Galinhas/fisiologia , Dieta/veterinária , Digestão/efeitos dos fármacos , Trato Gastrointestinal/efeitos dos fármacos , Nutrientes/metabolismo , Fenômenos Fisiológicos da Nutrição Animal/efeitos dos fármacos , Animais , Galinhas/crescimento & desenvolvimento , Feminino , Trato Gastrointestinal/fisiologia , Tamanho da Partícula
2.
J Laryngol Otol ; 122(5): 447-51, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-17625032

RESUMO

OBJECTIVE: To evaluate effectiveness of 5 mW laser irradiation in the treatment of chronic tinnitus. STUDY DESIGN: Prospective, randomised, double-blind study. METHODS: This investigation included 66 ears in 45 patients with chronic unilateral or bilateral tinnitus. A 5 mW laser with a wavelength of 650 nm, or placebo laser, was applied transmeatally for 15 minutes, once daily for a week. A questionnaire was administered which asked patients to score their symptoms on a five-point scale, before and two weeks after laser irradiation. A decrease of one scale point, regarding the loudness, duration and degree of annoyance of tinnitus, was accepted to represent an improvement. RESULTS: The loudness, duration and degree of annoyance of tinnitus were improved, respectively, in up to 48.8, 57.7 and 55.5 per cent of the patients in the active laser group. No significant improvement was observed in the placebo laser group. CONCLUSION: Transmeatal, low power (5 mW) laser irradiation was found to be useful for the treatment of chronic tinnitus.


Assuntos
Percepção Sonora/fisiologia , Terapia com Luz de Baixa Intensidade/métodos , Zumbido/radioterapia , Adulto , Idoso , Doença Crônica , Método Duplo-Cego , Feminino , Humanos , Terapia com Luz de Baixa Intensidade/normas , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Índice de Gravidade de Doença , Estatística como Assunto , Inquéritos e Questionários
3.
J Laryngol Otol ; 121(6): 609-10, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17359558

RESUMO

We report a patient who developed sudden, bilateral, sensorineural hearing loss during therapeutic use of iloprost for Raynaud's phenomenon. The sudden hearing loss was attributed to iloprost use and completely reversed in eight days with conservative therapy. Iloprost may be a potentially ototoxic drug, causing sudden hearing loss.


Assuntos
Perda Auditiva Bilateral/induzido quimicamente , Iloprosta/efeitos adversos , Vasodilatadores/efeitos adversos , Adulto , Testes Auditivos , Humanos , Masculino , Doença de Raynaud/tratamento farmacológico , Zumbido/induzido quimicamente
4.
J Oral Rehabil ; 31(6): 585-9, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15189317

RESUMO

The purpose of this study was to compare the retention of two different pre-fabricated posts cemented to the root canal with four different adhesive luting cements and a zinc phosphate cement. The crowns of 100 freshly extracted human mandibular central and lateral incisors were removed at the cementoenamel junction and divided into two main groups (A = ParaPost and B = Flexi-Post) and further divided into five subgroups to evaluate the effects of five different cements (Rely-X ARC, Panavia F, ParaPost Cement, Flexi-Flow Natural and Adhesor) each with 10 samples. Post-holes were prepared on all of the roots following the manufacturer's instructions. Each sample was placed into a specialized jig and tensile strength tests performed by using testing machine with a crosshead speed of 0.638 cm min(-1) and force applied until failure. The data were analysed with one-way anova (Post Hoc a Scheffe's S test) and two-way anova (P < 0.001). The Flexi-Post dowels had a mean of 54.21 kg (s.d. = 9.37) and demonstrated statistically higher retention than ParaPost dowels with a mean of 33.93 kg (s.d. = 10.69) for all of the cement groups (P < 0.001). In Flexi-Post and ParaPost dowel groups; Rely-X ARC was statistically higher than the Panavia F, ParaPost Cement, Flexi-Flow Natural and Adhesor (P < 0.05). Adhesor was significantly lower than the other subgroups (P < 0.05). Resin luting cements have demonstrated very high tensile strength potential for a strong bond to dentin.


Assuntos
Coroas , Retenção em Prótese Dentária/métodos , Restauração Dentária Permanente/métodos , Adesivos Dentinários , Técnica para Retentor Intrarradicular , Cimentos de Resina , Bis-Fenol A-Glicidil Metacrilato , Resinas Compostas , Cimentos Dentários , Análise do Estresse Dentário/métodos , Humanos , Incisivo , Polietilenoglicóis , Ácidos Polimetacrílicos , Resistência à Tração
5.
J Prosthet Dent ; 83(2): 210-5, 2000 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-10668034

RESUMO

STATEMENT OF PROBLEM: Resin bonding surface treatment methods for conventional silica-based dental ceramics are not reliable for glass infiltrated high alumina content In-Ceram ceramics. PURPOSE: This study developed an alternative surface treatment to improve resin bonding of glass-infiltrated aluminum oxide ceramic blasting with diamond particles and then observed the efficiency of this treatment. Material and methods. In-Ceram test specimens were prepared and divided into 2 groups. All specimens were sandblasted with Al(2)O(3), and blasted with diamond particles and 2 adhesive resins were applied. After bonding and storage in humid conditions, shear bond strength values were measured with a universal testing machine. Surface roughness and fracture interfaces were determined with a perthometer and a SEM. RESULTS: The highest bond strength was obtained on the samples blasted with diamond particles (group II). The differences between the 2 groups and the 2 adhesive resin cements were both statistically significant. CONCLUSION: Panavia-Ex cement exhibited higher bond strength than Super-Bond cement. This higher bond strength was attributed to ceramic oxide and ester bond and the mechanical properties of Panavia-Ex cement.


Assuntos
Óxido de Alumínio , Colagem Dentária , Porcelana Dentária , Cimentos de Resina , Análise de Variância , Compostos de Boro , Adesivos Dentinários , Diamante , Vidro , Teste de Materiais , Metacrilatos , Metilmetacrilatos , Microscopia Eletrônica de Varredura , Fosfatos , Propriedades de Superfície , Resistência à Tração
6.
Eur J Prosthodont Restor Dent ; 5(2): 79-83, 1997 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-9487816

RESUMO

The effects of diameter and position of implants on displacement and stress distribution, were investigated. ITI Hollow Cylinder two-stage implants with various diameters (3.5 mm, 4.5 mm and 6 mm) and positions are compared on the basis of a two dimensional finite element analysis. The mathematical results of this study demonstrate that, using conventional assumptions for stress levels in the crestal bone, relatively large diameter implants are preferable in the posterior mandibular area.


Assuntos
Dente Suporte/estatística & dados numéricos , Implantes Dentários/estatística & dados numéricos , Planejamento de Prótese Dentária/estatística & dados numéricos , Força de Mordida , Análise do Estresse Dentário/métodos , Análise do Estresse Dentário/estatística & dados numéricos , Elasticidade , Humanos , Modelos Biológicos , Análise Numérica Assistida por Computador , Estresse Mecânico , Suporte de Carga
7.
Eur J Prosthodont Restor Dent ; 5(2): 85-8, 1997 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-9487817

RESUMO

In order to avoid improper loading of implants, the type of prosthesis, as well as the number, localisation and position of the abutments, should be analysed. In this study three-unit fixed partial prostheses in the posterior mandibular region, supported by an angulated, standard or inclined Bonefit ITI Hollow-Cylinder two-stage implant connected to a natural tooth, are modelled and the stress distributions investigated using the finite element method. It is suggested that the angulated or inclined implant abutments may be recommended because of lower stress around the crestal region of the implant bone interface.


Assuntos
Dente Suporte/estatística & dados numéricos , Planejamento de Prótese Dentária/estatística & dados numéricos , Implantação Dentária Endóssea/estatística & dados numéricos , Prótese Dentária Fixada por Implante/estatística & dados numéricos , Análise do Estresse Dentário/métodos , Análise do Estresse Dentário/estatística & dados numéricos , Prótese Parcial Fixa/estatística & dados numéricos , Humanos , Modelos Biológicos , Análise Numérica Assistida por Computador , Estresse Mecânico , Suporte de Carga
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...