Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Med Tekh ; (3): 33-4, 1998.
Artigo em Russo | MEDLINE | ID: mdl-9720016

RESUMO

The advantages of an original regimen of acetate-free biofiltration as an alternative to hemodialysis, which has been modified and used in the treatment of patients on programmed hemodialysis, are shown. The method has been first used in Russia and may be used with the routine artificial kidney apparatus.


Assuntos
Hemodiafiltração/métodos , Hemodiafiltração/instrumentação , Humanos , Rins Artificiais
2.
Ter Arkh ; 66(6): 60-5, 1994.
Artigo em Russo | MEDLINE | ID: mdl-7940372

RESUMO

Biocompatibility assessed by values of dialysis leukopenia, complement system activation, that of blood elements was compared in the first and second use of capillary dialyzers equipped with various membranes. In the dialyzers re-use biocompatibility improved. Electron microscopy of hollow fiber sections suggested the role of protein layer safety on the membrane surface in biocompatibility under successive employment of the dialyzers. Treatment of the latter with acetic and peracetic acids mixture proved advantageous against other methods. Clinical effect due to dialyzer re-use changed positively.


Assuntos
Diálise Renal/instrumentação , Análise de Variância , Proteínas do Sistema Complemento/análise , Reutilização de Equipamento/estatística & dados numéricos , Segurança de Equipamentos , Feminino , Humanos , Falência Renal Crônica/sangue , Falência Renal Crônica/epidemiologia , Falência Renal Crônica/terapia , Contagem de Leucócitos , Leucotrieno B4/sangue , Masculino , Membranas Artificiais , Diálise Renal/estatística & dados numéricos , Esterilização/métodos , Fator de Necrose Tumoral alfa/análise , beta-Tromboglobulina/análise
3.
Med Tekh ; (4): 40-2, 1990.
Artigo em Russo | MEDLINE | ID: mdl-2215175

RESUMO

The authors provide the results of the clinical trial of the dialyzers DIP-03-02 manufactured by the USSR in cooperation with the FRG (Frezenius Company). In accordance with clearances of low-, medium- and high-molecular compounds as well as with the ultrafiltration characteristics, DIP-03-02 are similar to the modern capillary dialyzers from hollow fibers on the basis of cellulose membranes with an analogous surface. During manufacture of the dialyzers DIP-03-02, the polysulfone membrane possessing low permeability for liquid was obtained for the first time. The tentative data on biocompatibility (the complement activation test) are positive.


Assuntos
Falência Renal Crônica/terapia , Rins Artificiais , Adolescente , Adulto , Materiais Biocompatíveis , Estudos de Avaliação como Assunto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polímeros , Sulfonas
4.
Med Tekh ; (4): 33-4, 1990.
Artigo em Russo | MEDLINE | ID: mdl-2215172

RESUMO

The authors describe a method of hemodiafiltration with preparing the replacement solution from dialysis liquid by means of the AK-10 apparatus (Gambro Company, Sweden) and a sterilizing hemofilter. The studies attest to the high efficacy and safety of the procedure. An opportunity is provided of increasing the replacement velocity, with the rate of filtration being stable and even reduced, which is of paramount importance in cases of unstable hemodynamics. Such a scheme enables one to simplify the procedure and decrease the cost of hemodiafiltration, thus forming the basis for its broad-scale application.


Assuntos
Hemofiltração/métodos , Diálise Renal/métodos , Hemofiltração/instrumentação , Humanos , Diálise Renal/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...