Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 82
Filtrar
1.
Phys Rev Lett ; 131(22): 222501, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38101385

RESUMO

We report on the results obtained with the global CUPID-0 background model, which combines the data collected in the two measurement campaigns for a total exposure of 8.82 kg×yr of ^{82}Se. We identify with improved precision the background sources within the 3 MeV energy region, where neutrinoless double ß decay of ^{82}Se and ^{100}Mo is expected, making more solid the foundations for the background budget of the next-generation CUPID experiment. Relying on the excellent data reconstruction, we measure the two-neutrino double ß-decay half-life of ^{82}Se with unprecedented accuracy: T_{1/2}^{2ν}=[8.69±0.05(stat)_{-0.06}^{+0.09}(syst)]×10^{19} yr.

2.
Sci Rep ; 13(1): 10432, 2023 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-37369729

RESUMO

There is an urgent need for new, better instrumentation and techniques for detecting and characterizing special nuclear material (SNM), i.e., highly enriched uranium and plutonium. The development of improved instruments and techniques requires experiments performed with the SNM itself, which is of limited availability. This paper describes the findings of experiments performed at the National Criticality Experiments Research Center conducted using new instruments and techniques on unclassified, kg-quantity SNM objects. These experiments, performed in the framework of the Department of Energy, National Nuclear Security Administration Consortium for Monitoring, Technology, and Verification, focused on detecting, characterizing, and localizing SNM samples with masses ranging from 3.3 to 13.8 kg, including plutonium and highly enriched uranium using prototype detectors and techniques. The work demonstrates SNM detection and characterization using recently-developed prototype detection systems. Specifically, we present new results in passive detection and imaging of plutonium and uranium objects using gamma-ray and dual particle (fast neutron and gamma-ray) imaging. We also present a new analysis of the delayed neutron emissions during active interrogation of uranium using a neutron generator.

3.
Appl Radiat Isot ; 194: 110704, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36731392

RESUMO

Core-collapse Supernovae (SNe) are one of the most energetic events in the Universe, during which almost all the star's binding energy is released in the form of neutrinos. These particles are direct probes of the processes occurring in the stellar core and provide unique insights into the gravitational collapse. RES-NOVA will revolutionize how we detect neutrinos from astrophysical sources, by deploying the first ton-scale array of cryogenic detectors made from archaeological lead. Pb offers the highest neutrino interaction cross-section via coherent elastic neutrino-nucleus scattering (CEνNS). Such process will enable RES-NOVA to be equally sensitive to all neutrino flavours. For the first time, we propose the use archaeological Pb as sensitive target material in order to achieve an ultra-low background level in the region of interest (O(1 keV)). All these features make possible the deployment of the first cm-scale neutrino telescope for the investigation of astrophysical sources. In this contribution, we will characterize the radiopurity level and the performance of a small-scale proof-of-principle detector of RES-NOVA, consisting in a PbWO4 crystal made from archaeological-Pb operated as cryogenic detector.

4.
Phys Rev Lett ; 129(11): 111801, 2022 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-36154394

RESUMO

CUPID-0, an array of Zn^{82}Se cryogenic calorimeters, was the first medium-scale demonstrator of the scintillating bolometers' technology. The first project phase (March 2017-December 2018) allowed the most stringent limit on the neutrinoless double beta decay half-life of the isotope of interest, ^{82}Se, to be set. After a six month long detector upgrade, CUPID-0 began its second and last phase (June 2019-February 2020). In this Letter, we describe the search for neutrinoless double beta decay of ^{82}Se with a total exposure (phase I+II) of 8.82 kg yr^{-1} of isotope. We set a limit on the half-life of ^{82}Se to the ground state of ^{82}Kr of T_{1/2}^{0ν}(^{82}Se)>4.6×10^{24} yr (90% credible interval), corresponding to an effective Majorana neutrino mass m_{ßß}<(263-545) meV. We also set the most stringent lower limits on the neutrinoless decays of ^{82}Se to the 0_{1}^{+}, 2_{1}^{+}, and 2_{2}^{+} excited states of ^{82}Kr, finding 1.8×10^{23} yr, 3.0×10^{23} yr, and 3.2×10^{23} yr (90% credible interval) respectively.

5.
Phys Rev Lett ; 127(22): 222502, 2021 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-34889623

RESUMO

We investigate the angular momentum removal from fission fragments (FFs) through neutron and γ-ray emission, finding that about half the neutrons are emitted with angular momenta ≥1.5ℏ and that the change in angular momentum after the emission of neutrons and statistical γ rays is significant, contradicting usual assumptions. Per fission event, in our simulations, the neutron and statistical γ-ray emissions change the spin of the fragment by 3.5-5ℏ, with a large standard deviation comparable to the average value. Such wide angular momentum removal distributions can hide any underlying correlations in the fission fragment initial spin values. Within our model, we reproduce data on spin measurements from discrete transitions after neutron emissions, especially in the case of light FFs. The agreement further improves for the heavy fragments if one removes from the analysis the events that would produce isomeric states. Finally, we show that while in our model the initial FF spins do not follow a sawtoothlike behavior observed in recent measurements, the average FF spin computed after neutron and statistical γ emissions exhibits a shape that resembles a sawtooth. This suggests that the average FF spin measured after statistical emissions is not necessarily connected with the scission mechanism as previously implied.

6.
Eur Phys J C Part Fields ; 81(8): 722, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34720725

RESUMO

Localization and modeling of radioactive contaminations is a challenge that ultra-low background experiments are constantly facing. These are fundamental steps both to extract scientific results and to further reduce the background of the detectors. Here we present an innovative technique based on the analysis of α - α delayed coincidences in 232 Th and 238 U decay chains, developed to investigate the contaminations of the ZnSe crystals in the CUPID-0 experiment. This method allows to disentangle surface and bulk contaminations of the detectors relying on the different probability to tag delayed coincidences as function of the α decay position.

7.
Int J Oral Maxillofac Implants ; 36(1): 75-85, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33600526

RESUMO

PURPOSE: This study evaluated the mechanical behavior of different configurations of the All-on-4 treatment concept designed with straight short (6-mm-length), straight standard (11-mm-length), or tilted standard (30-degree angled; 11-mm-length) posterior implants. MATERIALS AND METHODS: The All-on-4 configurations were performed in atrophic mandible models and consisted of anterior straight standard and posterior tilted standard implants (H1 model), anterior straight standard and posterior straight short implants (H2 model), and anterior and posterior straight standard implants (H3 model). Three oblique forces of 100 N were simulated in the posterior region of the prosthetic bar. The values of stress were obtained for the ductile materials using the von Mises equivalent stress (σvm) criteria. The stress peaks in the peri-implant bone crest were measured by the maximum (σmax) and minimum (σmin) principal stresses. The two-way analysis of variance (two-way ANOVA) and Tukey post hoc tests determined significant differences (P < .01) of stress values among the ductile materials (implant and prosthetic components). RESULTS: The use of tilted standard posterior implants (H1 model) showed the lowest values of σmax and σmin in the posterior region of the peri-implant bone area. On the other hand, the use of straight short (H2 model) or straight standard (H3 model) posterior implants significantly reduced the von Mises mean stresses in the bar screws, abutments, and abutment screws (P < .01). CONCLUSION: The higher odds of technical failures (screw fracture/loosening) may be expected when the All-on-4 configuration is performed with tilted standard posterior implants. Also, peri-implant bone overload may occur when the All-on-4 design is performed with straight short or straight standard posterior implants in atrophic mandibles.


Assuntos
Implantes Dentários , Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante , Análise do Estresse Dentário , Análise de Elementos Finitos , Mandíbula/cirurgia , Estresse Mecânico
8.
Radiat Prot Dosimetry ; 191(3): 319-327, 2020 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-33112389

RESUMO

Traditionally available handheld dosemeters are generally sensitive to only one type of radiation: neutrons or photons. Some dosemeters also rely on very specific attenuation correlations between response and dose, are not scalable in size and multiple dosemeters are required to characterise mixed-particle fields. The research presented here serves as a proof-of-concept for a method to simultaneously measure dose rates from neutrons and photons using a particle discriminating organic scintillation detector without the need for spectral deconvolution. The method was compared with traditional instruments and to simulation. Isotopic photon dose rates measured with this method were within 4% of simulated truth, whereas fission spectrum neutron dose rates were measured within 21%. Measurements of dose rates from both particles agree with simulated truth better than traditional instruments. This new method allows for measurement of dose equivalent from both neutrons and photons with a single instrument and no reliance on spectral deconvolution.


Assuntos
Proteção Radiológica , Nêutrons , Fótons , Doses de Radiação , Dosímetros de Radiação
9.
Radiat Prot Dosimetry ; 191(2): 125-128, 2020 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-33125499

RESUMO

The estimation of the indoor radon exposure of the population of a country is generally carried out by the means of surveys designed in order to have sample representativeness as a target (population-based survey). However, the estimates of radon concentration distributions could be affected by biases if sampling was not random or in case of differences between sample and target population characteristics. In this work, we performed a preliminary check of the representativeness of the sample used for the second Italian national survey aimed to evaluate radon concentration distribution in each Province. We found that sampled dwellings are mostly located in the main administrative centres, where average radon concentration is generally lower, as compared with the other towns of the Province. The potential source of bias identified in this work suggests to carefully control the occurrence of a sampling imbalance between 'main' cities and other cities of Province and to take it into account in data analysis.


Assuntos
Poluentes Radioativos do Ar , Poluição do Ar em Ambientes Fechados , Monitoramento de Radiação , Radônio , Poluentes Radioativos do Ar/análise , Poluição do Ar em Ambientes Fechados/análise , Cidades , Habitação , Radônio/análise
10.
Phys Med Biol ; 65(15): 155002, 2020 07 28.
Artigo em Inglês | MEDLINE | ID: mdl-32197258

RESUMO

Carbon-ion beams are increasingly used in the clinical practice for external radiotherapy treatments of deep-seated tumors. At therapeutic energies, carbon ions yield significant secondary products, including neutrons, which may be of concern for the radiation protection of the patient and personnel. We simulated the neutron yield produced by proton and carbon-ion pencil beams impinging on a clinical phantom at three different angles: 15°, 45° and 90°, with respect to the beam axis. We validated the simulated results using the measured response of organic scintillation detectors. We compared the results obtained with FLUKA 2011.2 and MCNPX 2.7.0 based on three different physics models: Bertini, Isabel, and CEM. Over the different ions, energies, and angles, the FLUKA simulation results agree better with the measured data, compared to the MCNPX results. Simulations of carbon ions at low angles exhibit both the highest deviation from measured data and inter-model discrepancy, which is probably due to the different treatment of the pre-equilibrium stage. The reported neutron yield results could help in the comparison of carbon-ion and proton treatments in terms of secondary neutron production for radiation protection applications.


Assuntos
Radioterapia com Íons Pesados , Nêutrons , Método de Monte Carlo , Imagens de Fantasmas , Terapia com Prótons , Proteção Radiológica , Dosagem Radioterapêutica
11.
Phys Rev Lett ; 123(3): 032501, 2019 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-31386478

RESUMO

CUPID-0 is the first pilot experiment of CUPID, a next-generation project for the measurement of neutrinoless double beta decay (0νDBD) with scintillating bolometers. The detector, consisting of 24 enriched and 2 natural ZnSe crystals, has been taking data at Laboratori Nazionali del Gran Sasso from June 2017 to December 2018, collecting a ^{82}Se exposure of 5.29 kg×yr. In this Letter we present the phase-I results in the search for 0νDBD. We demonstrate that the technology implemented by CUPID-0 allows us to reach the lowest background for calorimetric experiments: (3.5_{-0.9}^{+1.0})×10^{-3} counts/(keV kg yr). Monitoring 3.88×10^{25} ^{82}Se nuclei×yr we reach a 90% credible interval median sensitivity of T_{1/2}^{0ν}>5.0×10^{24} yr and set the most stringent limit on the half-life of ^{82}Se 0νDBD: T_{1/2}^{0ν}>3.5×10^{24} yr (90% credible interval), corresponding to m_{ßß}<(311-638) meV depending on the nuclear matrix element calculations.

12.
Phys Rev Lett ; 123(26): 262501, 2019 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-31951429

RESUMO

We report on the measurement of the two-neutrino double-ß decay of ^{82}Se performed for the first time with cryogenic calorimeters, in the framework of the CUPID-0 experiment. With an exposure of 9.95 kg yr of Zn^{82}Se, we determine the two-neutrino double-ß decay half-life of ^{82}Se with an unprecedented precision level, T_{1/2}^{2ν}=[8.60±0.03(stat) _{-0.13}^{+0.19}(syst)]×10^{19} yr. The very high signal-to-background ratio, along with the detailed reconstruction of the background sources allowed us to identify the single state dominance as the underlying mechanism of such a process, demonstrating that the higher state dominance hypothesis is disfavored at the level of 5.5σ.

13.
Phys Rev Lett ; 120(23): 232502, 2018 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-29932707

RESUMO

We report the result of the search for neutrinoless double beta decay of ^{82}Se obtained with CUPID-0, the first large array of scintillating Zn^{82}Se cryogenic calorimeters implementing particle identification. We observe no signal in a 1.83 kg yr ^{82}Se exposure, and we set the most stringent lower limit on the 0νßß ^{82}Se half-life T_{1/2}^{0ν}>2.4×10^{24} yr (90% credible interval), which corresponds to an effective Majorana neutrino mass m_{ßß}<(376-770) meV depending on the nuclear matrix element calculations. The heat-light readout provides a powerful tool for the rejection of α particles and allows us to suppress the background in the region of interest down to (3.6_{-1.4}^{+1.9})×10^{-3} counts/(keV kg yr), an unprecedented level for this technique.

14.
Eur Phys J C Part Fields ; 78(11): 888, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30881205

RESUMO

The CUPID-0 experiment searches for double beta decay using cryogenic calorimeters with double (heat and light) read-out. The detector, consisting of 24 ZnSe crystals 95 % enriched in 82 Se and two natural ZnSe crystals, started data-taking in 2017 at Laboratori Nazionali del Gran Sasso. We present the search for the neutrino-less double beta decay of 82 Se into the 0 1 + , 2 1 + and 2 2 + excited states of 82 Kr with an exposure of 5.74 kg · yr (2.24 × 10 25  emitters · yr). We found no evidence of the decays and set the most stringent limits on the widths of these processes: Γ ( 82 Se → 82 Kr 0 1 + )8.55 × 10 - 24  yr - 1 , Γ ( 82 Se → 82 Kr 2 1 + ) < 6.25 × 10 - 24  yr - 1 , Γ ( 82 Se → 82 Kr 2 2 + )8.25 × 10 - 24  yr - 1 (90 % credible interval).

15.
Eur Phys J C Part Fields ; 78(5): 428, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30996670

RESUMO

The CUPID-0 detector hosted at the Laboratori Nazionali del Gran Sasso, Italy, is the first large array of enriched scintillating cryogenic detectors for the investigation of 82 Se neutrinoless double-beta decay ( 0 ν ß ß ). CUPID-0 aims at measuring a background index in the region of interest (RoI) for 0 ν ß ß at the level of 10 - 3  counts/(keV kg years), the lowest value ever measured using cryogenic detectors. CUPID-0 operates an array of Zn 82 Se scintillating bolometers coupled with bolometric light detectors, with a state of the art technology for background suppression and thorough protocols and procedures for the detector preparation and construction. In this paper, the different phases of the detector design and construction will be presented, from the material selection (for the absorber production) to the new and innovative detector structure. The successful construction of the detector lead to promising preliminary detector performance which is discussed here.

16.
Eur Phys J C Part Fields ; 78(9): 734, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30839752

RESUMO

The suppression of spurious events in the region of interest for neutrinoless double beta decay will play a major role in next generation experiments. The background of detectors based on the technology of cryogenic calorimeters is expected to be dominated by α particles, that could be disentangled from double beta decay signals by exploiting the difference in the emission of the scintillation light. CUPID-0, an array of enriched Zn 82 Se scintillating calorimeters, is the first large mass demonstrator of this technology. The detector started data-taking in 2017 at the Laboratori Nazionali del Gran Sasso with the aim of proving that dual read-out of light and heat allows for an efficient suppression of the α background. In this paper we describe the software tools we developed for the analysis of scintillating calorimeters and we demonstrate that this technology allows to reach an unprecedented background for cryogenic calorimeters.

17.
Radiat Prot Dosimetry ; 177(1-2): 99-103, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-29036511

RESUMO

International recommendations and regulations require developing of National Radon Action Plans (NRAPs) to effectively manage the protection of workers and population from radon exposure. In Italy, a NRAP was published in 2002 and several activities have been carried out in this framework. Information and data regarding these and previous activities have been collected in a National Radon Archive (NRA). Activities carried out by institutionally involved institutes and agencies include several national and regional surveys, involving more than 50 000 indoor environments (dwellings, schools and workplaces), and remedial actions performed in ~350 buildings, largely in schools. Data collected in the NRA allowed also to estimate that lung cancer deaths attributable to radon exposure in Italy are ~3400 per year. On-going developments of the Italian NRA finalized to effectively use it as tool for developing, monitoring and updating the NRAP are also described.


Assuntos
Poluentes Radioativos do Ar/análise , Poluição do Ar em Ambientes Fechados/análise , Arquivos , Exposição Ambiental/análise , Neoplasias Pulmonares/mortalidade , Neoplasias Induzidas por Radiação/mortalidade , Exposição Ocupacional/análise , Monitoramento de Radiação/normas , Radônio/análise , Habitação , Humanos , Itália/epidemiologia , Instituições Acadêmicas , Local de Trabalho
18.
Med Phys ; 43(11): 5915, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27806590

RESUMO

PURPOSE: The primary objective of this work is to measure the secondary neutron field produced by an uncollimated proton pencil beam impinging on different tissue-equivalent phantom materials using organic scintillation detectors. Additionally, the Monte Carlo code mcnpx-PoliMi was used to simulate the detector response for comparison to the measured data. Comparison of the measured and simulated data will validate this approach for monitoring secondary neutron dose during proton therapy. METHODS: Proton beams of 155- and 200-MeV were used to irradiate a variety of phantom materials and secondary particles were detected using organic liquid scintillators. These detectors are sensitive to fast neutrons and gamma rays: pulse shape discrimination was used to classify each detected pulse as either a neutron or a gamma ray. The mcnpx-PoliMi code was used to simulate the secondary neutron field produced during proton irradiation of the same tissue-equivalent phantom materials. RESULTS: An experiment was performed at the Loma Linda University Medical Center proton therapy research beam line and corresponding models were created using the mcnpx-PoliMi code. The authors' analysis showed agreement between the simulations and the measurements. The simulated detector response can be used to validate the simulations of neutron and gamma doses on a particular beam line with or without a phantom. CONCLUSIONS: The authors have demonstrated a method of monitoring the neutron component of the secondary radiation field produced by therapeutic protons. The method relies on direct detection of secondary neutrons and gamma rays using organic scintillation detectors. These detectors are sensitive over the full range of biologically relevant neutron energies above 0.5 MeV and allow effective discrimination between neutron and photon dose. Because the detector system is portable, the described system could be used in the future to evaluate secondary neutron and gamma doses on various clinical beam lines for commissioning and prospective data collection in pediatric patients treated with proton therapy.


Assuntos
Nêutrons , Terapia com Prótons/métodos , Contagem de Cintilação , Humanos , Método de Monte Carlo , Imagens de Fantasmas
19.
Prog Brain Res ; 228: 295-328, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27590973

RESUMO

In the last decades, it has been a fast-growing concept in the neuroscience field. The passive brain-computer interface (p-BCI) systems allow to improve the human-machine interaction (HMI) in operational environments, by using the covert brain activity (eg, mental workload) of the operator. However, p-BCI technology could suffer from some practical issues when used outside the laboratories. In particular, one of the most important limitations is the necessity to recalibrate the p-BCI system each time before its use, to avoid a significant reduction of its reliability in the detection of the considered mental states. The objective of the proposed study was to provide an example of p-BCIs used to evaluate the users' mental workload in a real operational environment. For this purpose, through the facilities provided by the École Nationale de l'Aviation Civile of Toulouse (France), the cerebral activity of 12 professional air traffic control officers (ATCOs) has been recorded while performing high realistic air traffic management scenarios. By the analysis of the ATCOs' brain activity (electroencephalographic signal-EEG) and the subjective workload perception (instantaneous self-assessment) provided by both the examined ATCOs and external air traffic control experts, it has been possible to estimate and evaluate the variation of the mental workload under which the controllers were operating. The results showed (i) a high significant correlation between the neurophysiological and the subjective workload assessment, and (ii) a high reliability over time (up to a month) of the proposed algorithm that was also able to maintain high discrimination accuracies by using a low number of EEG electrodes (~3 EEG channels). In conclusion, the proposed methodology demonstrated the suitability of p-BCI systems in operational environments and the advantages of the neurophysiological measures with respect to the subjective ones.


Assuntos
Aviação , Interfaces Cérebro-Computador , Encéfalo/fisiologia , Desempenho Psicomotor/fisiologia , Análise e Desempenho de Tarefas , Carga de Trabalho/psicologia , Adulto , Análise de Variância , Eletroencefalografia , Humanos , Masculino , Pessoa de Meia-Idade , Testes Neuropsicológicos , Reprodutibilidade dos Testes , Autoavaliação (Psicologia) , Detecção de Sinal Psicológico , Fatores de Tempo
20.
Eur Phys J C Part Fields ; 76(7): 364, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-28280442

RESUMO

The R&D activity performed during the last years proved the potential of ZnSe scintillating bolometers to the search for neutrino-less double beta decay, motivating the realization of the first large-mass experiment based on this technology: CUPID-0. The isotopic enrichment in [Formula: see text]Se, the Zn[Formula: see text]Se crystals growth, as well as the light detectors production have been accomplished, and the experiment is now in construction at Laboratori Nazionali del Gran Sasso (Italy). In this paper we present the results obtained testing the first three Zn[Formula: see text]Se crystals operated as scintillating bolometers, and we prove that their performance in terms of energy resolution, background rejection capability and intrinsic radio-purity complies with the requirements of CUPID-0.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...