Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Comput Methods Biomech Biomed Engin ; 21(16): 813-823, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30398077

RESUMO

The secondary lymphatic valve is a bi-leaflet structure frequent throughout collecting vessels that serves to prevent retrograde flow of lymph. Despite its vital function in lymph flow and apparent importance in disease development, the lymphatic valve and its associated fluid dynamics have been largely understudied. The goal of this work was to construct a physiologically relevant computational model of an idealized rat mesenteric lymphatic valve using fully coupled fluid-structure interactions to investigate the relationship between three-dimensional flow patterns and stress/deformation within the valve leaflets. The minimum valve resistance to flow, which has been shown to be an important parameter in effective lymphatic pumping, was computed as 268 g/mm4-s. Hysteretic behavior of the lymphatic valve was confirmed by comparing resistance values for a given transvalvular pressure drop during opening and closing. Furthermore, eddy structures were present within the sinus adjacent to the valve leaflets in what appear to be areas of vortical flow; the eddy structures were characterized by non-zero velocity values (up to ∼4 mm/s) in response to an applied unsteady transvalvular pressure. These modeling capabilities present a useful platform for investigating the complex interplay between soft tissue motion and fluid dynamics of lymphatic valves and contribute to the breadth of knowledge regarding the importance of biomechanics in lymphatic system function.


Assuntos
Hidrodinâmica , Vasos Linfáticos/fisiologia , Modelos Biológicos , Animais , Pressão , Ratos , Estresse Mecânico
2.
J Biomech Eng ; 2018 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-30029207

RESUMO

Transcatheter aortic valve replacement (TAVR) has emerged as an effective alternative to conventional surgical aortic valve replacement (SAVR) in high-risk elderly patients with calcified aortic valve disease. All currently FDA-approved TAVR devices use tissue valves that were adapted to but not specifically designed for TAVR use. Emerging clinical evidence indicates that these valves may get damaged during crimping and deployment- leading to valvular calcification, thrombotic complications, and limited durability. This impedes the expected expansion of TAVR to lower-risk and younger patients. Viable polymeric valves have the potential to overcome such limitations. We have developed a polymeric SAVR valve, which was optimized to reduce leaflet stresses and offer a thromboresistance profile similar to that of a tissue valve. This study compares the polymeric SAVR valve's hemodynamic performance and mechanical stresses to a new version of the valve- specifically designed for TAVR. Fluid-structure interaction (FSI) models were utilized and the valves' hemodynamics, flexural stresses, strains, orifice area, and wall shear stresses were compared. The TAVR valve had 42% larger opening area and 27% higher flow rate versus the SAVR valve, while wall shear stress distribution and mechanical stress magnitudes were of the same order, demonstrating the enhanced performance of the TAVR valve prototype. The TAVR valve FSI simulation and Vivitro pulse duplicator experiments were compared in terms of the leaflets' kinematics and the effective orifice area. The numerical methodology presented can be further used as a predictive tool for valve design optimization for enhanced hemodynamics and durability.

3.
J Cardiovasc Transl Res ; 7(9): 788-96, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25354999

RESUMO

The SynCardia total artificial heart (TAH) is the only Food and Drug Administration (FDA) approved device for replacing hearts in patients with congestive heart failure. It pumps blood via pneumatically driven diaphragms and controls the flow with mechanical valves. While it has been successfully implanted in more than 1300 patients, its size precludes implantation in smaller patients. This study's aim was to evaluate the viability of scaled-down TAHs by quantifying thrombogenic potentials from flow patterns. Simulations of systole were first conducted with stationary valves, followed by an advanced full-cardiac cycle model with moving valves. All the models included deforming diaphragms and platelet suspension in the blood flow. Flow stress accumulations were computed for the platelet trajectories and thrombogenic potentials were assessed. The simulations successfully captured complex flow patterns during various phases of the cardiac cycle. Increased stress accumulations, but within the safety margin of acceptable thrombogenicity, were found in smaller TAHs, indicating that they are clinically viable.


Assuntos
Coração Artificial , Hemodinâmica/fisiologia , Ativação Plaquetária/fisiologia , Desenho de Equipamento , Coração Artificial/efeitos adversos , Hidrodinâmica , Modelos Biológicos , Estresse Mecânico , Trombose/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...