Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Life (Basel) ; 13(2)2023 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-36836939

RESUMO

BACKGROUND: The benefit of prophylactic left ventricular (LV) unloading during venoarterial extracorporeal membrane oxygenation (VA-ECMO) in selected patients at risk of developing LV distension remains unclear. METHODS: We enrolled 136 patients treated with Impella pump decompression during VA-ECMO therapy for refractory cardiogenic shock. Patients were stratified by specific indication for LV unloading in the prophylactic vs. bail-out group. The bail-out unloading strategy was utilized to treat LV distension in VA-ECMO afterload-associated complications. The primary endpoint was all-cause 30-day mortality after VA-ECMO implantation. The secondary endpoint was successful myocardial recovery, transition to durable mechanical circulatory support (MCS), or heart transplantation. RESULTS: After propensity score matching, prophylactic unloading was associated with a significantly lower 30-day mortality risk (risk ratio 0.38, 95% confidence interval 0.23-0.62, and p < 0.001) and a higher probability of myocardial recovery (risk ratio 2.9, 95% confidence interval 1.48-4.54, and p = 0.001) compared with the bail-out strategy. Heart transplantation or durable MCS did not differ significantly between groups. CONCLUSIONS: Prophylactic unloading compared with the bail-out strategy may improve clinical outcomes in selected patients on VA-ECMO. Nevertheless, randomized trials are needed to validate these results.

2.
ESC Heart Fail ; 8(2): 1253-1262, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33480186

RESUMO

AIMS: Heart transplantation (HTx) represents optimal care for advanced heart failure. Left ventricular assist devices (LVADs) are often needed as a bridge-to-transplant (BTT) therapy to support patients during the wait for a donor organ. Prolonged support increases the risk for LVAD complications that may affect the outcome after HTx. METHODS AND RESULTS: A total of 342 patients undergoing HTx after LVAD as BTT in a 10-year period in two German high-volume HTx centres were retrospectively analysed. While 73 patients were transplanted without LVAD complications and with regular waiting list status (T, n = 73), the remaining 269 patients were transplanted with high urgency status (HU) and further divided with regard to the observed leading LVAD complications (infection: HU1, n = 91; thrombosis: HU2, n = 32; stroke: HU3, n = 38; right heart failure: HU4, n = 41; arrhythmia: HU5, n = 23; bleeding: HU6, n = 18; device malfunction: HU7, n = 26). Postoperative hospitalization was prolonged in patients with LVAD complications. Analyses of perioperative morbidity revealed no differences regarding primary graft dysfunction, renal failure, and neurological events except postoperative infections. Short-term survival, as well as Kaplan-Meier survival analysis, indicated comparable results between the different study groups without disadvantages for patients with LVAD complications. CONCLUSIONS: Left ventricular assist device therapy can impair the outcome after HTx. However, the occurrence of LVAD complications may not impact on outcome after HTx. Thus, we cannot support the prioritization or discrimination of HTx candidates according to distinct mechanical circulatory support-associated complications. Future allocation strategies have to respect that device-related complications may define urgency but do not impact on the outcome after HTx.


Assuntos
Transplante de Coração , Coração Auxiliar , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Listas de Espera
3.
J Card Surg ; 35(8): 1832-1839, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32557925

RESUMO

BACKGROUND: The clinical profile of left ventricular assist device (LVAD) candidates is rapidly changing, with increasing proportion of patients in more stable clinical conditions. However, early postoperative right ventricular failure (eRVF) is still one of the cornerstones associated with increased mortality and the preoperative recognition of associated risk factors remains challenging. The aim of this study was to identify predictive parameters for eRVF after LVAD implantation in patients with preoperative intermediate Intermacs (InM) risk profile 3-5. METHODS: Preoperative laboratory, echocardiography, and right heart catheterization data collected from 80 patients with InM profile 3-5 before LVAD implantation were retrospectively tested with respect to their ability to predict the risk for eRVF after the implantation of a continuous-flow LVAD. RESULTS: Preoperative higher bilirubin and blood urea nitrogen (BUN) levels, higher Model for End-stage Liver Disease score, lower estimated glomerular filtration rate, and higher central venous pressure to pulmonary capillary wedge pressure ratio (CVP/PCWP) were associated to higher risk of eRVF. Regarding the echocardiographic assessment, higher end diastolic linear dimensions of the RV, higher basal end diastolic RV linear dimension to LV ratio, severe tricuspid regurgitation, lower tricuspid annular plane systolic excursion, and lower RV fractional area contraction identified patients with higher risk for eRVF. In the multivariable analysis, a CVP/CPWP > 0.55 (odds ratio [OR]: 4, 95% confidence interval [CII]: 1.4-11.8;P = .01) and BUN > 44.5 mg/dL (OR: 6.6, 95% CI: 1.51-23; P = .011) independently predicted the risk of eRVF. CONCLUSION: Preoperative BUN > 44.5 mg/dL and CVP/PCWP > 0.55 are associated to an increased risk of eRVF following LVAD implantation in intermediate InM patients.


Assuntos
Insuficiência Cardíaca/etiologia , Coração Auxiliar/efeitos adversos , Disfunção Ventricular Direita/etiologia , Nitrogênio da Ureia Sanguínea , Progressão da Doença , Ventrículos do Coração , Humanos , Período Pré-Operatório , Pressão Propulsora Pulmonar , Fatores de Risco
4.
Transpl Immunol ; 41: 27-31, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28167272

RESUMO

OBJECTIVES: Identifying patients at risk for impaired long-term survival after heart transplantation (HT) remains a clinical challenge. The aim of this analysis was to investigate whether the gene expression profiling test AlloMap® is related to long-term survival after HT. METHODS: 46 patients who underwent HT between 2006 and 2007 who were originally included into the CARGO II trial at our institution were investigated. Patients were divided in two groups according to an increase or decrease of the AlloMap® score between 6 and 9months after HT. The primary endpoint of this study was long-term all-cause mortality. RESULTS: 23 patients showed an increase of the AlloMap® score between 6 and 9months after HT whereas the remaining 23 patients presented with a decrease of the score. After a median follow-up time of 8.1years (interquartile range 7.6-8.6), all-cause mortality was significantly elevated in patients with an AlloMap® increase compared with patients who showed a decrease of the score (log-rank p=0.005). A ratio of the AlloMap® at 9months to 6months of 1.02 or less was associated with a negative predictive value for all-cause mortality of 100%. CONCLUSIONS: Dynamic changes of the AlloMap® score between 6 and 9months after HT were strongly related to all-cause long-term survival after HT. These results suggest that AlloMap® potentially displays a useful tool to estimate the patients' risk for long-term mortality.


Assuntos
Regulação da Expressão Gênica , Insuficiência Cardíaca , Transplante de Coração , Adulto , Idoso , Intervalo Livre de Doença , Feminino , Seguimentos , Perfilação da Expressão Gênica , Insuficiência Cardíaca/metabolismo , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Taxa de Sobrevida
5.
Eur Heart J Cardiovasc Imaging ; 17(12): 1385-1393, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26758411

RESUMO

AIMS: New-onset conduction disturbances still represent a considerable problem after transcatheter aortic valve implantation (TAVI). The aim of this study was to identify calcification patterns with an elevated risk for permanent pacemaker implantation (PPI) after TAVI and investigate underlying mechanisms in an ex vivo setting. METHODS AND RESULTS: One hundred and sixty-two patients who underwent TAVI with the Edwards SAPIEN XT® or Medtronic CoreValve® at our institution were analysed. The calcium load of the device landing zone was quantified with 3mensio®, and calcium patterns with an elevated risk for PPI were identified. Ex vivo simulations of balloon valvuloplasty were performed in 3D-printed silicone annuli of patients matching the identified risk profile. Patients with a calcium load of the left coronary cusp (LCC) above 209 mm3 had a higher rate of PPI than patients below this threshold (16.7 vs. 2.6%, P = 0.003). Multivariate regression revealed pre-existing right bundle branch block (RBBB) and increased LCC calcification as independent predictors for PPI. Simulation of the TAVI procedure in a silicone annulus revealed an off-centreline shift of the valvuloplasty balloon and transcatheter heart valve away from the LCC towards the commissure between right- and non-coronary cusp. CONCLUSION: Pre-existing RBBB and elevated LCC calcification were identified as independent predictors for PPI. These two risk factors enabled us to distinguish between patients according to their risk for PPI after TAVI. Ex vivo simulations suggested an off-centreline shift of the balloon as a possible explanation.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estimulação Cardíaca Artificial/métodos , Ecocardiografia Tridimensional/métodos , Interpretação de Imagem Assistida por Computador , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Análise de Variância , Estenose da Valva Aórtica/mortalidade , Cálcio/metabolismo , Estudos de Coortes , Intervalos de Confiança , Eletrocardiografia/métodos , Feminino , Humanos , Masculino , Análise Multivariada , Razão de Chances , Marca-Passo Artificial , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/terapia , Prognóstico , Estudos Prospectivos , Medição de Risco , Taxa de Sobrevida , Substituição da Valva Aórtica Transcateter/efeitos adversos
6.
Eur Heart J Cardiovasc Imaging ; 17(5): 576-84, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26160399

RESUMO

AIMS: Calcification of the device landing zone is linked to paravalvular regurgitation after transcatheter aortic valve implantation (TAVI). The mechanisms remain incompletely understood and the performance of next-generation transcatheter heart valves (THV) has not been investigated. We evaluated the impact of calcification patterns on residual aortic regurgitation (AR) after TAVI with different THV in patients with severe aortic stenosis. METHODS AND RESULTS: TAVI was performed in 537 patients at two centres. Devices implanted were the Edwards Sapien XT (n = 254), Medtronic CoreValve (n = 123), JenaValve (n = 62), Medtronic Engager (n = 56), and Symetis Acurate (n = 42) prostheses. Calcification of the device landing zone was retrospectively assessed from contrast-enhanced multidetector computed tomography data and correlated with echocardiographic and clinical data. Calcium volumes of the aortic valve and left-ventricular outflow tract were associated with residual AR: No AR, 604 mm(3) (inter-quartile range, IQR 349-916); trace AR, 639 mm(3) (IQR 368-948); mild AR, 710 mm(3) (IQR 412-2078); ≥moderate AR, 1041 mm(3) (IQR 791-1417, P = 0.001). Device landing zone calcium, particularly if located in the left-ventricular outflow tract, and a low cover index were predictive of AR. Differences in the incidence of AR were observed with regard to THV type. Higher calcium volume was associated with the need for post-dilation (n = 134, median 852 [IQR 342-945] vs. 604 [IQR 542-1207] mm(3), P < 0.001). CONCLUSION: Calcification of the device landing zone, particularly if located inferior to the annulus, was independently associated with residual AR after TAVI with all evaluated THV; however, the incidence of paravalvular leakage differed significantly between the devices implanted.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Calcinose/diagnóstico por imagem , Calcinose/cirurgia , Ecocardiografia/métodos , Tomografia Computadorizada Multidetectores/métodos , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/métodos , Meios de Contraste/farmacologia , Feminino , Alemanha , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Substituição da Valva Aórtica Transcateter/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...