Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Int J Cardiol ; 382: 68-75, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-37028710

RESUMO

BACKGROUND: The balloon expandable Myval transcatheter heart valve (THV) showed encouraging results regarding residual aortic regurgitation (AR) from multiple observational studies. The newly designed Myval Octacor has been introduced recently, aiming for a reduction in AR and improved performance. OBJECTIVES: The focus of this study is to report the incidence of AR using the validated quantitative Videodensitometry angiography technology (qLVOT-AR%) in the first in human use of the Myval Octacor THV system. METHODOLOGY: We report on the first in human use of the Myval Octacor THV system in 125 patients in 18 Indian centres. Independent retrospective analysis of the final aortograms following implantation of the Myval Octacor was performed using the CAAS-A-Valve software. AR is reported as a regurgitation fraction. The previously validated cutoff values have been used to identify ≥moderate AR (RF% >17%), mild (6% < RF% ≤17%), and none or trace AR (RF% ≤ 6%). RESULTS: Final aortogram was analysable for 103 patients (84.4%) among the 122 available aortograms. 64 (62%) patients, had tricuspid aortic valve (TAV), 38 (37%) with bicuspid AV (BAV), and one with unicuspid AV. The median absolute RF% was 2% [1, 6], moderate or more AR incidence was 1.9%, mild AR in 20.4%, and none or trace AR in 77.7%. The two cases with RF% >17% were in the BAV group. CONCLUSION: The initial results of Myval Octacor using quantitative angiography-derived regurgitation fraction demonstrated a favourable outcome regarding residual AR, possibly due to improved device design. Results must be confirmed in a larger randomised study, including other imaging modalities.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Aortografia/métodos , Próteses Valvulares Cardíacas/efeitos adversos , Desenho de Prótese , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
2.
Indian Heart J ; 69 Suppl 1: S24-S27, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28400035

RESUMO

BACKGROUND: Post-infarction ventricular septal rupture (VSR) is a rare but lethal mechanical complication of an acute myocardial infarction (AMI). Survival to 1 month without intervention is 6%. Given high surgical mortality, transcatheter closure has emerged as a potential strategy in selected cases. Indian data on percutaneous device closure of post AMI-VSR is scarce hence we report our single-centre experience with ASD occluder device (Amplatzer and lifetech) for closure of post-AMI VSR. METHODS AND RESULTS: In this single-centre, retrospective, cohort study, patients who underwent transcatheter closure of post-MI VSR between 2005 and 2015 at KIMS Hospital were included. Primary outcome was mortality rate at 30 days. Seven patients were included in the study (mean age, 58.29±9.8 years). 5 patients had anterior wall myocardial infarction (AWMI) & 2 had inferior wall myocardial infarction (IWMI). None of the patients received thrombolytic therapy. Device was successfully placed in 5 patients (71.4%) with minimal residual shunt in 2 patients (40%). Out of 7 cases 2 patients survived (29% survival rate) and are doing well on follow up at 1 and 5 years respectively. Cardiogenic shock, IWMI and serpigenious form of VSR were associated with poor outcomes. Delayed revascularization (PCI) was associated with better outcomes. CONCLUSION: Percutaneous closure is a potential technique in a selected group of patients. The presence of cardiogenic shock, IWMI and serpigeneous form of VSR constitutes important risk factors for mortality. Device implantation is in general successful with few procedure-related complications and should be applied on a case-by-case basis.


Assuntos
Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Dispositivo para Oclusão Septal , Choque Cardiogênico/etiologia , Cirurgia Assistida por Computador/métodos , Ruptura do Septo Ventricular/cirurgia , Idoso , Ecocardiografia Transesofagiana , Feminino , Fluoroscopia , Seguimentos , Humanos , Índia/epidemiologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/mortalidade , Taxa de Sobrevida/tendências , Resultado do Tratamento , Ruptura do Septo Ventricular/complicações , Ruptura do Septo Ventricular/diagnóstico
3.
J Clin Diagn Res ; 11(1): OD06-OD07, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28273994

RESUMO

In cases involving stenosis or occlusions in major parts of a long vessel, natural tapering of coronary vessels may create dilemma in deciding the optimal stent size during percutaneous coronary intervention. In this regard, tapered stents have been developed recently. Herein, we present a case of 67-year-old male patient with triple vessel disease including two tandem lesions in naturally tapered Left Anterior Descending (LAD) artery. The patient received a 3.0-2.5x60 mm Sirolimus-eluting BioMime Morph stent (Meril life Sciences, Gujarat, India) in the mid-distal LAD lesion along with conventional stent implantations in other two lesions. The procedure was successful and good coronary flow was obtained after revascularization. The patient remained asymptomatic thereafter. At one year, angiographic follow-up revealed good flow and no restenosis in the LAD vessel. We are of opinion that using tapered stents with decremented diameter may offer the advantages of excellent adaptation to vessel size, vessel tapering, and good apposition in patients with long coronary lesions in tapered vessels.

4.
BMJ Case Rep ; 20142014 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-25406218

RESUMO

An acquired aortopulmonary fistula is a rare and usually fatal phenomenon. Rarer still are reports of successful surgical repair of aortopulmonary fistulae. We present the case of a 48-year-old hypertensive man who presented with congestive cardiac failure. Examination revealed a bicuspid aortic valve and a large aneurysm of the arch of the aorta, which was communicating with the main pulmonary artery. The diagnosis of acquired aortopulmonary fistula was made using transthoracic echocardiography findings and confirmed by CT. The patient was successfully managed by surgery, with an uneventful postoperative recovery, with control of congestive cardiac failure. At 1-year follow-up, the patient had Class I symptoms.


Assuntos
Valva Aórtica/anormalidades , Fístula Artério-Arterial/cirurgia , Implante de Prótese Vascular/métodos , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Artéria Pulmonar/anormalidades , Valva Aórtica/cirurgia , Fístula Artério-Arterial/complicações , Fístula Artério-Arterial/diagnóstico , Doença da Válvula Aórtica Bicúspide , Ecocardiografia , Seguimentos , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Pulmonar/cirurgia , Tomografia Computadorizada por Raios X
5.
J Thromb Thrombolysis ; 31(4): 445-8, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-20972606

RESUMO

This is a retrospective study documenting the use of tenecteplase in 41 cases of suspected or confirmed pulmonary embolism receiving in-hospital tenecteplase as per weight-adjusted dosing in addition to standard heparin and oral anticoagulant therapy. The presenting symptoms of dyspnoea, chest pain, hemoptysis and syncope were found in 40 (97.56%), 19 (46.34%), 6 (14.63%) and 9 (21.95%) patients, respectively. There was one case of mortality who was a 26 yrs old female of postpartum pulmonary thrombo-embolism with severe hypotension, cyanosis, bilateral crepitations in lungs and pulmonary hypertension. In the 40 survived patients, there was alleviation of dyspnoea and hemoptysis in all patients. Significant reduction in tachycardia (P < 0.0001) and increase in the oxygen saturation (SaO2) (P < 0.0001) were seen at discharge as compared to at the time of presentation. Eighteen patients had hypotension which recovered in all patients till the time of discharge (P < 0.0001). There was a significant reduction in right ventricular systolic pressure in all 18 patients who underwent 2-D echocardiography both before and after the tenecteplase therapy. Resolution of pulmonary embolism on CT pulmonary angiography was documented in only two patients. No bleeding events or any other adverse events were reported during this study. The present study suggests favourable efficacy of tenecteplase in patients with suspected or confirmed acute pulmonary embolism. Although no major adverse events were noted, a large prospective study on the use of tenecteplase in pulmonary embolism is suggested.


Assuntos
Fibrinolíticos/administração & dosagem , Hipotensão/tratamento farmacológico , Embolia Pulmonar/tratamento farmacológico , Ativador de Plasminogênio Tecidual/administração & dosagem , Doença Aguda , Adulto , Idoso , Pressão Sanguínea/efeitos dos fármacos , Feminino , Humanos , Hipotensão/sangue , Hipotensão/diagnóstico por imagem , Hipotensão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Embolia Pulmonar/sangue , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/fisiopatologia , Radiografia , Estudos Retrospectivos , Tenecteplase
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...