Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 13(1): 10629, 2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37391450

RESUMO

Modern communication and navigation systems are increasingly relying on atomic clocks. As timing precision requirements increase, demands for lower SWaP (size, weight, and power) clocks rise. However, it has been challenging to break through the general trade-off trend between the clock stability performance and SWaP. Here we demonstrate micro mercury trapped ion clock (M2TIC) prototypes integrated with novel micro-fabricated technologies to simultaneously achieve high performance and low SWaP. The M2TIC prototypes could reach the [Formula: see text]-stability level in 1 day with a SWaP of 1.1 L, 1.2 kg, and under 6 W of power. This stability level is comparable to the widely used rack-mount Microchip 5071A cesium frequency standard. These standalone prototypes survived regular commercial shipping across the North American continent to a government laboratory, where their performance was independently tested. The M2TIC sets a new reference point for SWaP and performance and opens opportunities for high-performance clocks in terrestrial and space applications.


Assuntos
Césio , Mercúrio , Comunicação , Governo , Íons
2.
Artigo em Inglês | MEDLINE | ID: mdl-29856712

RESUMO

Routine use of one-way radiometric tracking for deep space navigation and radio science is not possible today because spacecraft frequency and time references that use state-of-the-art ultrastable oscillators introduce errors from their intrinsic drift and instability on timescales past 100 s. The Deep Space Atomic Clock (DSAC), currently under development as a NASA Technology Demonstration Mission, is an advanced prototype of a space-flight suitable, mercury-ion atomic clock that can provide an unprecedented frequency and time stability in a space-qualified clock. Indeed, the ground-based results of the DSAC space demonstration unit have already achieved an Allan deviation of at one day; space performance on this order will enable the use of one-way radiometric signals for deep space navigation and radio science.

3.
Rev Sci Instrum ; 87(5): 053112, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-27250397

RESUMO

We report on the development of a highly miniaturized vacuum package for use in an atomic clock utilizing trapped ytterbium-171 ions. The vacuum package is approximately 1 cm(3) in size and contains a linear quadrupole RF Paul ion trap, miniature neutral Yb sources, and a non-evaporable getter pump. We describe the fabrication process for making the Yb sources and assembling the vacuum package. To prepare the vacuum package for ion trapping, it was evacuated, baked at a high temperature, and then back filled with a helium buffer gas. Once appropriate vacuum conditions were achieved in the package, it was sealed with a copper pinch-off and was subsequently pumped only by the non-evaporable getter. We demonstrated ion trapping in this vacuum package and the operation of an atomic clock, stabilizing a local oscillator to the 12.6 GHz hyperfine transition of (171)Y b(+). The fractional frequency stability of the clock was measured to be 2 × 10(-11)/τ(1/2).

4.
Artigo em Inglês | MEDLINE | ID: mdl-27019481

RESUMO

There are many different atomic frequency standard technologies but only few meet the demanding performance, reliability, size, mass, and power constraints required for space operation. The Jet Propulsion Laboratory is developing a linear ion-trap-based mercury ion clock, referred to as DSAC (Deep-Space Atomic Clock) under NASA's Technology Demonstration Mission program. This clock is expected to provide a new capability with broad application to space-based navigation and science. A one-year flight demonstration is planned as a hosted payload following an early 2017 launch. This first-generation mercury ion clock for space demonstration has a volume, mass, and power of 17 L, 16 kg, and 47 W, respectively, with further reductions planned for follow-on applications. Clock performance with a signal-to-noise ratio (SNR)*Q limited stability of 1.5E-13/τ(1/2) has been observed and a fractional frequency stability of 2E-15 at one day measured (no drift removed). Such a space-based stability enables autonomous timekeeping of with a technology capable of even higher stability, if desired. To date, the demonstration clock has been successfully subjected to mechanical vibration testing at the 14 grms level, thermal-vacuum operation over a range of 42(°)C, and electromagnetic susceptibility tests.

SELEÇÃO DE REFERÊNCIAS