Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
AJNR Am J Neuroradiol ; 42(4): 774-781, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33602745

RESUMO

BACKGROUND AND PURPOSE: Head motion causes image degradation in brain MR imaging examinations, negatively impacting image quality, especially in pediatric populations. Here, we used a retrospective motion correction technique in children and assessed image quality improvement for 3D MR imaging acquisitions. MATERIALS AND METHODS: We prospectively acquired brain MR imaging at 3T using 3D sequences, T1-weighted MPRAGE, T2-weighted TSE, and FLAIR in 32 unsedated children, including 7 with epilepsy (age range, 2-18 years). We implemented a novel motion correction technique through a modification of k-space data acquisition: Distributed and Incoherent Sample Orders for Reconstruction Deblurring by using Encoding Redundancy (DISORDER). For each participant and technique, we obtained 3 reconstructions as acquired (Aq), after DISORDER motion correction (Di), and Di with additional outlier rejection (DiOut). We analyzed 288 images quantitatively, measuring 2 objective no-reference image quality metrics: gradient entropy (GE) and MPRAGE white matter (WM) homogeneity. As a qualitative metric, we presented blinded and randomized images to 2 expert neuroradiologists who scored them for clinical readability. RESULTS: Both image quality metrics improved after motion correction for all modalities, and improvement correlated with the amount of intrascan motion. Neuroradiologists also considered the motion corrected images as of higher quality (Wilcoxon z = -3.164 for MPRAGE; z = -2.066 for TSE; z = -2.645 for FLAIR; all P < .05). CONCLUSIONS: Retrospective image motion correction with DISORDER increased image quality both from an objective and qualitative perspective. In 75% of sessions, at least 1 sequence was improved by this approach, indicating the benefit of this technique in unsedated children for both clinical and research environments.


Assuntos
Artefatos , Neuroimagem , Adolescente , Encéfalo/diagnóstico por imagem , Criança , Pré-Escolar , Humanos , Imageamento por Ressonância Magnética , Movimento (Física) , Estudos Retrospectivos
2.
Magn Reson Med ; 82(5): 1631-1645, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31183892

RESUMO

PURPOSE: To investigate the potential of continuous radiofrequency (RF) shifting (SWEEP) as a technique for creating densely sampled data while maintaining a stable signal state for dynamic imaging. METHODS: We present a method where a continuous stable state of magnetization is swept smoothly across the anatomy of interest, creating an efficient approach to dense multiple 2D slice imaging. This is achieved by introducing a linear frequency offset to successive RF pulses shifting the excited slice by a fraction of the slice thickness with each successive repeat times (TR). Simulations and in vivo imaging were performed to assess how this affects the measured signal. Free breathing, respiration resolved 4D volumes in fetal/placental imaging is explored as potential application of this method. RESULTS: The SWEEP method maintained a stable signal state over a full acquisition reducing artifacts from unstable magnetization. Simulations demonstrated that the effects of SWEEP on slice profiles was of the same order as that produced by physiological motion observed with conventional methods. Respiration resolved 4D data acquired with this method shows reduced respiration artifacts and resilience to non-rigid and non-cyclic motion. CONCLUSIONS: The SWEEP method is presented as a technique for improved acquisition efficiency of densely sampled short-TR 2D sequences. Using conventional slice excitation the number of RF pulses required to enter a true steady state is excessively high when using short-TR 2D acquisitions, SWEEP circumvents this limitation by creating a stable signal state that is preserved between slices.


Assuntos
Imageamento por Ressonância Magnética/métodos , Respiração , Artefatos , Mapeamento Encefálico/métodos , Simulação por Computador , Feminino , Humanos , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética , Placenta/irrigação sanguínea , Placenta/diagnóstico por imagem , Gravidez
3.
Phys Rev Lett ; 88(13): 137002, 2002 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-11955116

RESUMO

Evidence for static alternating magnetic fields in the vortex cores of underdoped YBa2Cu3O6+x is reported. Muon spin rotation measurements of the internal magnetic field distribution of the vortex state of YBa2Cu3O6.50 in applied fields of H = 1 T and H = 4 T reveal a feature in the high-field tail of the field distribution which is not present in optimally doped YBa2Cu3O6.95 and which fits well to a model with static magnetic fields in the vortex cores. The magnitude of the fields is estimated to be 18(2) G and decreases above T = 10 K. We discuss possible origins of the additional vortex core magnetism within the context of existing theories.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...