Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38580083

RESUMO

PURPOSE: We aimed to demonstrate the clinical feasibility and safety of simulation-free hippocampal avoidance whole brain radiation therapy (HA-WBRT) in a pilot study (NCTXXX). MATERIALS/METHODS: Ten HA-WBRT candidates were enrolled for treatment on a commercially available computed tomography (CT)-guided linear accelerator with online adaptive capabilities. Planning structures were contoured on patient-specific diagnostic MRIs, which were registered to a CT of similar head shape, obtained from an atlas-based database (AB-CT). These patient-specific diagnostic MRI and AB-CT datasets were used for pre-plan calculation, using NRG-CC001 constraints. At first fraction, AB-CTs were used as primary datasets and deformed to patient-specific cone-beam CTs (CBCT) to give patient-matched density information. Brain, ventricle, and brainstem contours were matched through rigid translation and rotation to the corresponding anatomy on CBCT. Lens, optic nerve, and brain contours were manually edited based on CBCT visualization. Pre-plans were then re-optimized through online adaptation to create final, simulation-free plans, which were utilized if they met all objectives. Workflow tasks were timed. In addition, patients underwent CT-simulation to create immobilization devices and for prospective dosimetric comparison of simulation-free and simulation-based plans. RESULTS: Median time from MRI importation to completion of "pre-plan" was one week-day (range: 1-4). Median on-table workflow duration was 41 minutes (range: 34-70). NRG-CC001 constraints were achieved by 90% of the simulation-free plans. One patient's simulation-free plan failed a planning target volume (PTV) coverage objective (89% instead of 90% coverage); this was deemed acceptable for first-fraction delivery, with an offline replan used for subsequent fractions. Both simulation-free and simulation-CT-based plans otherwise met constraints, without clinically meaningful differences. CONCLUSION: Simulation-free HA-WBRT using online ART is feasible, safe, and results in dosimetrically comparable treatment plans to simulation-CT-based workflows while providing convenience and time-savings for patients.

2.
J Appl Clin Med Phys ; 25(4): e14242, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38178622

RESUMO

PURPOSE: High-quality CBCT and AI-enhanced adaptive planning techniques allow CBCT-guided stereotactic adaptive radiotherapy (CT-STAR) to account for inter-fractional anatomic changes. Studies of intra-fractional respiratory motion management with a surface imaging solution for CT-STAR have not been fully conducted. We investigated intra-fractional motion management in breath-hold Ethos-based CT-STAR and CT-SBRT (stereotactic body non-adaptive radiotherapy) using optical surface imaging combined with onboard CBCTs. METHODS: Ten cancer patients with mobile lower lung or upper abdominal malignancies participated in an IRB-approved clinical trial (Phase I) of optical surface image-guided Ethos CT-STAR/SBRT. In the clinical trial, a pre-configured gating window (± 2 mm in AP direction) on optical surface imaging was used for manually triggering intra-fractional CBCT acquisition and treatment beam irradiation during breath-hold (seven patients for the end of exhalation and three patients for the end of inhalation). Two inter-fractional CBCTs at the ends of exhalation and inhalation in each fraction were acquired to verify the primary direction and range of the tumor/imaging-surrogate (donut-shaped fiducial) motion. Intra-fractional CBCTs were used to quantify the residual motion of the tumor/imaging-surrogate within the pre-configured breath-hold window in the AP direction. Fifty fractions of Ethos RT were delivered under surface image-guidance: Thirty-two fractions with CT-STAR (adaptive RT) and 18 fractions with CT-SBRT (non-adaptive RT). The residual motion of the tumor was quantified by determining variations in the tumor centroid position. The dosimetric impact on target coverage was calculated based on the residual motion. RESULTS: We used 46 fractions for the analysis of intra-fractional residual motion and 43 fractions for the inter-fractional motion analysis due to study constraints. Using the image registration method, 43 pairs of inter-fractional CBCTs and 100 intra-fractional CBCTs attached to dose maps were analyzed. In the motion range study (image registration) from the inter-fractional CBCTs, the primary motion (mean ± std) was 16.6 ± 9.2 mm in the SI direction (magnitude: 26.4 ± 11.3 mm) for the tumors and 15.5 ± 7.3 mm in the AP direction (magnitude: 20.4 ± 7.0 mm) for the imaging-surrogate, respectively. The residual motion of the tumor (image registration) from intra-fractional breath-hold CBCTs was 2.2 ± 2.0 mm for SI, 1.4 ± 1.4 mm for RL, and 1.3 ± 1.3 mm for AP directions (magnitude: 3.5 ± 2.1 mm). The ratio of the actual dose coverage to 99%, 90%, and 50% of the target volume decreased by 0.95 ± 0.11, 0.96 ± 0.10, 0.99 ± 0.05, respectively. The mean percentage of the target volume covered by the prescribed dose decreased by 2.8 ± 4.4%. CONCLUSION: We demonstrated the intra-fractional motion-managed treatment strategy in breath-hold Ethos CT-STAR/SBRT using optical surface imaging and CBCT. While the controlled residual tumor motion measured at 3.5 mm exceeded the predetermined setup value of 2 mm, it is important to note that this motion still fell within the clinically acceptable range defined by the PTV margin of 5 mm. Nonetheless, additional caution is needed with intra-fractional motion management in breath-hold Ethos CT-STAR/SBRT using optical surface imaging and CBCT.


Assuntos
Neoplasias Pulmonares , Radiocirurgia , Radioterapia Guiada por Imagem , Tomografia Computadorizada de Feixe Cônico Espiral , Humanos , Suspensão da Respiração , Tomografia Computadorizada de Feixe Cônico/métodos , Estudos de Viabilidade , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/patologia , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos
3.
World J Orthop ; 15(1): 39-44, 2024 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-38293257

RESUMO

BACKGROUND: Total hip arthroplasty (THA) is a common procedure for end stage osteoarthritis. The learning curve for THA is complex and challenging. One of the most difficult skills to master is acetabular reaming. We wish to identify if experience in arthroplasty leads to preservation of more bone stock. AIM: To investigate if increasing surgeon experience will predict an ever decreasing acetabular cup size. METHODS: A retrospective case series of four attending orthopaedic surgeons was completed. All uncemented elective total hip arthroplasties since appointment were selected for inclusion. The size of acetabular cup used was noted and logistic regression was used to identify if a trend to smaller cups existed. RESULTS: A total of 1614 subjects were included with a mean age of 64 years. Overall cups were on average 0.18mm smaller per year (95% confidence interval -0.25 to -0.11, P < 0.001). Individual surgeon trends showed cup sizes to decrease 0.27 mm/year for surgeon A, 0.02 mm/year for surgeon B, 0.15 mm/year for surgeon C and 0.29 mm/year for surgeon D. Three of the four surgeons had a more pronounced trend to smaller cups for male subjects than their female counterparts. CONCLUSION: We found increasing surgeon experience to be associated with an ever-decreasing acetabular cup size. Smaller acetabular cup size may act as a surrogate marker of surgical proficiency by virtue of decreased acetabular reaming.

4.
Microorganisms ; 12(1)2024 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-38257974

RESUMO

The Makgadikgadi Salt Pans are the remnants of a mega paleo-lake system in the central Kalahari, Botswana. Today, the Makgadikgadi Basin is an arid to semi-arid area receiving water of meteoric origin during the short, wet season. Large microbial mats, which support primary production, are formed due to desiccation during the dry season. This study aimed to characterise the microbial diversity of the microbial mats and the underlying sediment. The focus was the Ntwetwe Pan, located west of the Makgadikgadi Basin. Metagenomic analyses demonstrated that the mats consisted of a high relative abundance of Cyanobacteriota (synonym Cyanobacteria) (20.50-41.47%), Pseudomonadota (synonym Proteobacteria) (15.71 to 32.18%), and Actinomycetota (synonym Actinobacteria) (8.53-32.56%). In the underlying sediments, Pseudomonadota, Actinomycetota, and Euryarchaeota represented over 70% of the community. Localised fluctuations in water content and pH did not significantly affect the microbial diversity of the sediment or the mats.

5.
Adv Health Care Manag ; 222024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38262009

RESUMO

Barriers to adequate healthcare in rural areas remain a grand challenge for local healthcare systems. In addition to patients' travel burdens, lack of health insurance, and lower health literacy, rural healthcare systems also experience significant resource shortages, as well as issues with recruitment and retention of healthcare providers, particularly specialists. These factors combined result in complex change management-focused challenges for rural healthcare systems. Change management initiatives are often resource intensive, and in rural health organizations already strapped for resources, it may be particularly risky to embark on change initiatives. One way to address these change management concerns is by leveraging socio-technical simulation models to estimate techno-economic feasibility (e.g., is it technologically feasible, and is it economical?) as well as socio-utility feasibility (e.g., how will the changes be utilized?). We present a framework for how healthcare systems can integrate modeling and simulation techniques from systems engineering into a change management process. Modeling and simulation are particularly useful for investigating the amount of uncertainty about potential outcomes, guiding decision-making that considers different scenarios, and validating theories to determine if they accurately reflect real-life processes. The results of these simulations can be integrated into critical change management recommendations related to developing readiness for change and addressing resistance to change. As part of our integration, we present a case study showcasing how simulation modeling has been used to determine feasibility and potential resistance to change considerations for implementing a mobile radiation oncology unit. Recommendations and implications are discussed.


Assuntos
Gestão de Mudança , Impulso (Psicologia) , Humanos , Simulação por Computador , Engenharia , Instalações de Saúde
6.
Prostate Cancer Prostatic Dis ; 27(1): 37-45, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37296271

RESUMO

Artificial intelligence (AI) applications have enabled remarkable advancements in healthcare delivery. These AI tools are often aimed to improve accuracy and efficiency of histopathology assessment and diagnostic imaging interpretation, risk stratification (i.e., prognostication), and prediction of therapeutic benefit for personalized treatment recommendations. To date, multiple AI algorithms have been explored for prostate cancer to address automation of clinical workflow, integration of data from multiple domains in the decision-making process, and the generation of diagnostic, prognostic, and predictive biomarkers. While many studies remain within the pre-clinical space or lack validation, the last few years have witnessed the emergence of robust AI-based biomarkers validated on thousands of patients, and the prospective deployment of clinically-integrated workflows for automated radiation therapy design. To advance the field forward, multi-institutional and multi-disciplinary collaborations are needed in order to prospectively implement interoperable and accountable AI technology routinely in clinic.


Assuntos
Inteligência Artificial , Neoplasias da Próstata , Masculino , Humanos , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/terapia , Estudos Prospectivos , Algoritmos , Biomarcadores
7.
Radiother Oncol ; 191: 110064, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38135187

RESUMO

BACKGROUND AND PURPOSE: Radiation dose escalation may improve local control (LC) and overall survival (OS) in select pancreatic ductal adenocarcinoma (PDAC) patients. We prospectively evaluated the safety and efficacy of ablative stereotactic magnetic resonance (MR)-guided adaptive radiation therapy (SMART) for borderline resectable (BRPC) and locally advanced pancreas cancer (LAPC). The primary endpoint of acute grade ≥ 3 gastrointestinal (GI) toxicity definitely related to SMART was previously published with median follow-up (FU) 8.8 months from SMART. We now present more mature outcomes including OS and late toxicity. MATERIALS AND METHODS: This prospective, multi-center, single-arm open-label phase 2 trial (NCT03621644) enrolled 136 patients (LAPC 56.6 %; BRPC 43.4 %) after ≥ 3 months of any chemotherapy without distant progression and CA19-9 ≤ 500 U/mL. SMART was delivered on a 0.35 T MR-guided system prescribed to 50 Gy in 5 fractions (biologically effective dose10 [BED10] = 100 Gy). Elective coverage was optional. Surgery and chemotherapy were permitted after SMART. RESULTS: Mean age was 65.7 years (range, 36-85), induction FOLFIRINOX was common (81.7 %), most received elective coverage (57.4 %), and 34.6 % had surgery after SMART. Median FU was 22.9 months from diagnosis and 14.2 months from SMART, respectively. 2-year OS from diagnosis and SMART were 53.6 % and 40.5 %, respectively. Late grade ≥ 3 toxicity definitely, probably, or possibly attributed to SMART were observed in 0 %, 4.6 %, and 11.5 % patients, respectively. CONCLUSIONS: Long-term outcomes from the phase 2 SMART trial demonstrate encouraging OS and limited severe toxicity. Additional prospective evaluation of this novel strategy is warranted.


Assuntos
Neoplasias Pancreáticas , Radiocirurgia , Humanos , Idoso , Neoplasias Pancreáticas/patologia , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Planejamento da Radioterapia Assistida por Computador , Radiocirurgia/efeitos adversos
8.
Phys Imaging Radiat Oncol ; 28: 100491, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37772278

RESUMO

Background and Purpose: Hippocampal-avoidance whole brain radiotherapy (HA-WBRT) can be a time-consuming process compared to conventional whole brain techniques, thus potentially limiting widespread utilization. Therefore, we evaluated the in silico clinical feasibility, via dose-volume metrics and timing, by leveraging a computed tomography (CT)-based commercial adaptive radiotherapy (ART) platform and workflow in order to create and deliver patient-specific, simulation-free HA-WBRT. Materials and methods: Ten patients previously treated for central nervous system cancers with cone-beam computed tomography (CBCT) imaging were included in this study. The CBCT was the adaptive image-of-the-day to simulate first fraction on-board imaging. Initial contours defined on the MRI were rigidly matched to the CBCT. Online ART was used to create treatment plans at first fraction. Dose-volume metrics of these simulation-free plans were compared to standard-workflow HA-WBRT plans on each patient CT simulation dataset. Timing data for the adaptive planning sessions were recorded. Results: For all ten patients, simulation-free HA-WBRT plans were successfully created utilizing the online ART workflow and met all constraints. The median hippocampi D100% was 7.8 Gy (6.6-8.8 Gy) in the adaptive plan vs 8.1 Gy (7.7-8.4 Gy) in the standard workflow plan. All plans required adaptation at first fraction due to both a failing hippocampal constraint (6/10 adaptive fractions) and sub-optimal target coverage (6/10 adaptive fractions). Median time for the adaptive session was 45.2 min (34.0-53.8 min). Conclusions: Simulation-free HA-WBRT, with commercially available systems, was clinically feasible via plan-quality metrics and timing, in silico.

9.
Clin Transl Radiat Oncol ; 42: 100661, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37529627

RESUMO

Introduction: Our institution was the first in the world to clinically implement MR-guided adaptive radiotherapy (MRgART) in 2014. In 2021, we installed a CT-guided adaptive radiotherapy (CTgART) unit, becoming one of the first clinics in the world to build a dual-modality ART clinic. Herein we review factors that lead to the development of a high-volume dual-modality ART program and treatment census over an initial, one-year period. Materials and Methods: The clinical adaptive service at our institution is enabled with both MRgART (MRIdian, ViewRay, Inc, Mountain View, CA) and CTgART (ETHOS, Varian Medical Systems, Palo Alto, CA) platforms. We analyzed patient and treatment information including disease sites treated, radiation dose and fractionation, and treatment times for patients on these two platforms. Additionally, we reviewed our institutional workflow for creating, verifying, and implementing a new adaptive workflow on either platform. Results: From October 2021 to September 2022, 256 patients were treated with adaptive intent at our institution, 186 with MRgART and 70 with CTgART. The majority (106/186) of patients treated with MRgART had pancreatic cancer, and the most common sites treated with CTgART were pelvis (23/70) and abdomen (20/70). 93.0% of treatments on the MRgART platform were stereotactic body radiotherapy (SBRT), whereas only 72.9% of treatments on the CTgART platform were SBRT. Abdominal gated cases were allotted a longer time on the CTgART platform compared to the MRgART platform, whereas pelvic cases were allotted a shorter time on the CTgART platform when compared to the MRgART platform. Our adaptive implementation technique has led to six open clinical trials using MRgART and seven using CTgART. Conclusions: We demonstrate the successful development of a dual platform ART program in our clinic. Ongoing efforts are needed to continue the development and integration of ART across platforms and disease sites to maximize access and evidence for this technique worldwide.

10.
Int J Radiat Oncol Biol Phys ; 117(4): 799-808, 2023 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-37210048

RESUMO

PURPOSE: Magnetic resonance (MR) image guidance may facilitate safe ultrahypofractionated radiation dose escalation for inoperable pancreatic ductal adenocarcinoma. We conducted a prospective study evaluating the safety of 5-fraction Stereotactic MR-guided on-table Adaptive Radiation Therapy (SMART) for locally advanced (LAPC) and borderline resectable pancreatic cancer (BRPC). METHODS AND MATERIALS: Patients with LAPC or BRPC were eligible for this multi-institutional, single-arm, phase 2 trial after ≥3 months of systemic therapy without evidence of distant progression. Fifty gray in 5 fractions was prescribed on a 0.35T MR-guided radiation delivery system. The primary endpoint was acute grade ≥3 gastrointestinal (GI) toxicity definitely attributed to SMART. RESULTS: One hundred thirty-six patients (LAPC 56.6%, BRPC 43.4%) were enrolled between January 2019 and January 2022. Mean age was 65.7 (36-85) years. Head of pancreas lesions were most common (66.9%). Induction chemotherapy mostly consisted of (modified)FOLFIRINOX (65.4%) or gemcitabine/nab-paclitaxel (16.9%). Mean CA19-9 after induction chemotherapy and before SMART was 71.7 U/mL (0-468). On-table adaptive replanning was performed for 93.1% of all delivered fractions. Median follow-up from diagnosis and SMART was 16.4 and 8.8 months, respectively. The incidence of acute grade ≥3 GI toxicity possibly or probably attributed to SMART was 8.8%, including 2 postoperative deaths that were possibly related to SMART in patients who had surgery. There was no acute grade ≥3 GI toxicity definitely related to SMART. One-year overall survival from SMART was 65.0%. CONCLUSIONS: The primary endpoint of this study was met with no acute grade ≥3 GI toxicity definitely attributed to ablative 5-fraction SMART. Although it is unclear whether SMART contributed to postoperative toxicity, we recommend caution when pursuing surgery, especially with vascular resection after SMART. Additional follow-up is ongoing to evaluate late toxicity, quality of life, and long-term efficacy.


Assuntos
Neoplasias Pancreáticas , Radiocirurgia , Humanos , Idoso , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/radioterapia , Neoplasias Pancreáticas/tratamento farmacológico , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Estudos Prospectivos , Planejamento da Radioterapia Assistida por Computador , Qualidade de Vida , Pâncreas , Espectroscopia de Ressonância Magnética , Radiocirurgia/métodos , Neoplasias Pancreáticas
11.
Adv Radiat Oncol ; 8(6): 101226, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37206996

RESUMO

Purpose: We conducted a prospective, in silico study to evaluate the feasibility of cone-beam computed tomography (CBCT)-guided stereotactic adaptive radiation therapy (CT-STAR) for the treatment of ultracentral thoracic cancers (NCT04008537). We hypothesized that CT-STAR would reduce dose to organs at risk (OARs) compared with nonadaptive stereotactic body radiation therapy (SBRT) while maintaining adequate tumor coverage. Methods and Materials: Patients who were already receiving radiation therapy for ultracentral thoracic malignancies underwent 5 additional daily CBCTs on the ETHOS system as part of a prospective imaging study. These were used to simulate CT-STAR, in silico. Initial, nonadaptive plans (PI) were created based on simulation images and simulated adaptive plans (PA) were based on study CBCTs. 55 Gy/5 fractions was prescribed, with OAR constraint prioritization over PTV coverage under a strict isotoxicity approach. PI were applied to patients' anatomy of the day and compared with daily PA using dose-volume histogram metrics, with selection of superior plans for simulated delivery. Feasibility was defined as completion of the end-to-end adaptive workflow while meeting strict OAR constraints in ≥80% of fractions. CT-STAR was performed under time pressures to mimic clinical adaptive processes. Results: Seven patients were accrued, 6 with intraparenchymal tumors and 1 with a subcarinal lymph node. CT-STAR was feasible in 34 of 35 simulated fractions. In total, 32 dose constraint violations occurred when the PI was applied to anatomy-of-the-day across 22 of 35 fractions. These violations were resolved by the PA in all but one fraction, in which the proximal bronchial tree dose was still numerically improved through adaptation. The mean difference between the planning target volume and gross total volume V100% in the PI and the PA was -0.24% (-10.40 to 9.90) and -0.62% (-11.00 to 8.00), respectively. Mean end-to-end workflow time was 28.21 minutes (18.02-50.97). Conclusions: CT-STAR widened the dosimetric therapeutic index of ultracentral thorax SBRT compared with nonadaptive SBRT. A phase 1 protocol is underway to evaluate the safety of this paradigm for patients with ultracentral early-stage NSCLC.

12.
Radiother Oncol ; 182: 109603, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36889595

RESUMO

INTRODUCTION: We aimed to develop knowledge-based tools for robust adaptive radiotherapy (ART) planning to determine on-table adaptive DVH metric variations or planning process errors for stereotactic pancreatic ART. We developed volume-based dosimetric identifiers to identify deviations of ART plans from simulation plans. MATERIALS AND METHODS: Two patient cohorts who were treated on MR-Linac for pancreas cancer were included in this retrospective study; a training cohort and a validation cohort. All patients received 50 Gy in 5 fractions. PTV-OPT was generated by subtracting the critical organs plus a 5 mm-margin from PTV. Several metrics that potentially can identify failure-modes were calculated including PTV & PTV_OPT V95% and PTV & PTV_OPT D95%/D5%. The difference between each DVH metric in each adaptive plan with the DVH metric in simulation plan was calculated. The 95% confidence interval (CI) of the variations in each DVH metric was calculated for the patient training cohort. Variations in DVH metrics that exceeded the 95% CI for all fractions in training and validation cohort were flagged for retrospective investigation for root-cause analysis to determine their predictive power for identifying failure-modes. RESULTS: The CIs for the PTV & PTV_OPT V95% and PTV & PTV_OPT D95%/D5% were ± 13%, ± 5%, ± 0.1, ± 0.03, respectively. We estimated the positive predictive value and negative predictive value of our method to be 77% and 89%, respectively, for the training cohort, and 80% for both in the validation cohort. DISCUSSION: We developed dosimetric indicators for ART planning QA to identify population-based deviations or planning errors during online adaptive process for stereotactic pancreatic ART. This technology may be useful as an ART clinical trial QA tool and improve overall ART quality at an institution.


Assuntos
Neoplasias Pancreáticas , Radioterapia de Intensidade Modulada , Humanos , Dosagem Radioterapêutica , Estudos Retrospectivos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Órgãos em Risco , Neoplasias Pancreáticas/radioterapia , Neoplasias Pancreáticas
13.
Phys Imaging Radiat Oncol ; 25: 100423, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36852334

RESUMO

Contouring during adaptive radiotherapy (ART) can be a time-consuming process. This study describes the generation of patient specific contouring regions of interest (CRoI) for evaluating the high dose fall-off in stereotactic abdominal ART. An empirical equation was derived to determine the radius of a cylindrical patient specific CRoIs. These CRoIs were applied to 60 patients and their adaptive fractions (301 unique treatment plans). Out of the 301 unique treatment plans, 284 (94%) treatment plans contained the high dose fall-off within the CRoI. There was an expected predicted average timesaving of 2.9-min-per case. Patient specific CRoIs improves the efficiency of ART.

14.
Adv Radiat Oncol ; 8(3): 101138, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36691450

RESUMO

Purpose: This study aimed to develop a routine quality assurance method for a dose accumulation technique provided by a radiation therapy platform for online treatment adaptation. Methods and Materials: Two commonly used phantoms were selected for the dose accumulation QA: Electron density and anthropomorphic pelvis. On a computed tomography (CT) scan of the electron density phantom, 1 target (gross tumor volume [GTV]; insert at 6 o'clock), a subvolume within this target, and 7 organs at risk (OARs; other inserts) were contoured in the treatment planning system (TPS). Two adaptation sessions were performed in which the GTV was recontoured, first at 7 o'clock and then at 5 o'clock. The accumulated dose was exported from the TPS after delivery. Deformable vector fields were also exported to manually accumulate doses for comparison. For the pelvis phantom, synthetic Gaussian deformations were applied to the planning CT image to simulate organ changes. Two single-fraction adaptive plans were created based on the deformed planning CT and cone beam CT images acquired onboard the radiation therapy platform. A manual dose accumulation was performed after delivery using the exported deformable vector fields for comparison with the system-generated result. Results: All plans were successfully delivered, and the accumulated dose was both manually calculated and derived from the TPS. For the electron density phantom, the average mean dose differences in the GTV, boost volume, and OARs 1 to 7 were 0.0%, -0.2%, 92.0%, 78.4%, 1.8%, 1.9%, 0.0%, 0.0%, and 2.3%, respectively, between the manually summed and platform-accumulated doses. The gamma passing rates for the 3-dimensional dose comparison between the manually generated and TPS-provided dose accumulations were >99% for both phantoms. Conclusions: This study demonstrated agreement between manually obtained and TPS-generated accumulated doses in terms of both mean structure doses and local 3-dimensional dose distributions. Large disagreements were observed for OAR1 and OAR2 defined on the electron density phantom due to OARs having lower deformation priority over the target in addition to artificially large changes in position induced for these structures fraction-by-fraction. The tests applied in this study to a commercial platform provide a straightforward approach toward the development of routine quality assurance of dose accumulation in online adaptation.

15.
Clin Transl Radiat Oncol ; 39: 100561, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36594078

RESUMO

We conducted a prospective pilot study evaluating the feasibility of same day MRI-only simulation and treatment with MRI-guided adaptive palliative radiotherapy (MAP-RT) for urgent palliative indications (NCT#03824366). All (16/16) patients were able to complete 99% of their first on-table attempted fractions, and no grades 3-5 toxicities occurred.

16.
Clin Transl Radiat Oncol ; 39: 100577, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36718251

RESUMO

Two abdominal patients were treated with Lattice stereotactic body radiation therapy (SBRT) using magnetic resonance guided radiation therapy (MRgRT). This is one of the first reported treatments of Lattice SBRT with the use of MRgRT. A description of the treatment approach and planning considerations were incorporated into this report. MRgRT Lattice SBRT delivered similar planning quality metrics to established dosimetric parameters for Lattice SBRT. Increased signal intensity were seen in the MRI treatments for one of the patients during the course of treatment.

17.
Radiother Oncol ; 175: 144-151, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36063981

RESUMO

BACKGROUND AND PURPOSE: We conducted a prospective, in silico imaging clinical trial to evaluate the feasibility and potential dosimetric benefits of computed tomography-guided stereotactic adaptive radiotherapy (CT-STAR) for the treatment of locally advanced pancreatic cancer (LAPC). MATERIALS AND METHODS: Eight patients with LAPC received five additional CBCTs on the ETHOS system before or after their standard of care radiotherapy treatment. Initial plans were created based on their initial simulation anatomy (PI) and emulated adaptive plans were created based on their anatomy-of-the-day (PA). The prescription was 50 Gy/5 fractions. Plans were created under a strict isotoxicity approach, in which organ-at-risk (OAR) constraints were prioritized over planning target volume coverage. The PI was evaluated on the patient's anatomy-of-the-day, compared to the daily PA, and the superior plan was selected. Feasibility was defined as successful completion of the workflow in compliance with strict OAR constraints in ≥80% of fractions. RESULTS: CT-STAR was feasible in silico for LAPC and improved OAR and/or target dosimetry in 100% of fractions. Use of the PI based on the patient's anatomy-of-the-day would have yielded a total of 94 OAR constraint violations and ≥1 hard constraint violation in 40/40 fractions. In contrast, 39/40 PA met all OAR constraints. In one fraction, the PA minimally exceeded the large bowel constraint, although dosimetrically improved compared to the PI. Total workflow time per fraction was 36.28 minutes (27.57-55.86). CONCLUSION: CT-STAR for the treatment of LAPC cancer proved feasible and was dosimetrically superior to non-adapted CT-stereotactic body radiotherapy.


Assuntos
Segunda Neoplasia Primária , Neoplasias Pancreáticas , Radiocirurgia , Radioterapia Guiada por Imagem , Radioterapia de Intensidade Modulada , Humanos , Órgãos em Risco , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/radioterapia , Neoplasias Pancreáticas/cirurgia , Estudos Prospectivos , Radiocirurgia/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Radioterapia de Intensidade Modulada/métodos , Tomografia Computadorizada por Raios X
18.
Radiat Oncol ; 17(1): 157, 2022 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-36100866

RESUMO

BACKGROUND: Online adaptive stereotactic radiotherapy allows for improved target and organ at risk (OAR) delineation and inter-fraction motion management via daily adaptive planning. The use of adaptive SBRT for the treatment of pancreatic cancer (performed until now using only MRI or CT on rails-guided adaptive radiotherapy), has yielded promising outcomes. Herein we describe the first reported case of cone beam CT-guided stereotactic adaptive radiotherapy (CT-STAR) for the treatment of pancreatic cancer. CASE PRESENTATION: A 61-year-old female with metastatic pancreatic cancer presented for durable palliation of a symptomatic primary pancreatic mass. She was prescribed 35 Gy/5 fractions utilizing CT-STAR. The patient was simulated utilizing an end-exhale CT with intravenous and oral bowel contrast. Both initial as well as daily adapted plans were created adhering to a strict isotoxicity approach in which coverage was sacrificed to meet critical luminal gastrointestinal OAR hard constraints. Kilovoltage cone beam CTs were acquired on each day of treatment and the radiation oncologist edited OAR contours to reflect the patient's anatomy-of-the-day. The initial and adapted plan were compared using dose volume histogram objectives, and the superior plan was delivered. Use of the initial treatment plan would have resulted in nine critical OAR hard constraint violations. The adapted plans achieved hard constraints in all five fractions for all four critical luminal gastrointestinal structures. CONCLUSIONS: We report the successful treatment of a patient with pancreatic cancer treated with CT-STAR. Prior to this treatment, the delivery of ablative adaptive radiotherapy for pancreatic cancer was limited to clinics with MR-guided and CT-on-rails adaptive SBRT technology and workflows. CT-STAR is a promising modality with which to deliver stereotactic adaptive radiotherapy for pancreatic cancer.


Assuntos
Neoplasias Pancreáticas , Radiocirurgia , Radioterapia Guiada por Imagem , Tomografia Computadorizada de Feixe Cônico , Feminino , Humanos , Pessoa de Meia-Idade , Órgãos em Risco , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/radioterapia , Radiocirurgia/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Tomografia Computadorizada por Raios X , Neoplasias Pancreáticas
19.
Materials (Basel) ; 15(14)2022 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-35888435

RESUMO

Using powder X-ray diffraction and AC impedance spectroscopy, we have found that the superprotonic CsH2PO4 (CDP) phase is stable at T = 250 °C when sealed in different volumes (15 mL and 50 mL) of dry air or inert gasses. Under these conditions, CDP's proton conductivity stays constant at 2.5 × 10-2 S·cm-1 for at least 10 h. On the other hand, removing the gas from the chamber leads to a sharp, two-order-of-magnitude drop in the proton conductivity. Our data show no evidence of a self-generated water vapor atmosphere in the chamber, and the gas pressure at T = 250 °C is several orders of magnitude below the pressures previously used to stabilize CDP's superprotonic phase. These results demonstrate that hermetically sealing CDP in small gas-filled volumes represents a new method to stabilize the superprotonic phase, which opens new paths for large-scale applications of phosphate-based solid acids as fuel cell electrolytes.

20.
Int J Radiat Oncol Biol Phys ; 114(5): 1022-1031, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-35768023

RESUMO

PURPOSE: We conducted a prospective, in silico clinical imaging study (NCT04008537) to evaluate the feasibility of cone beam computed tomography-guided stereotactic adaptive radiation therapy (CT-STAR) for the treatment of abdominal oligometastases. We hypothesized that CT-STAR produces improved dosimetry compared with nonadapted CT-stereotactic body radiation therapy (SBRT). METHODS AND MATERIALS: Eight patients receiving stereotactic body radiation therapy for abdominal oligometastatic disease received 5 additional kV cone beam CTs on the ETHOS system. These additional cone beam CTs were used for imaging during an emulator treatment session. Initial plans were created based on their simulation (PI) and emulated adaptive plans were based on anatomy-of-the-day. The prescription was 50 Gy out of 5 fractions. Organ-at-risk (OAR) constraints were prioritized over planning target volume coverage under a strict isotoxicity approach. The PI was applied to the patient's anatomy-of-the-day and compared with the reoptimized adaptive plans using dose-volume histogram metrics, with selection of the superior plan. Feasibility was defined as completion of the adaptive workflow and compliance with strict OAR constraints in ≥80% of fractions. Fractions were performed under time pressures by a physician and physicist to mimic the adaptive process. RESULTS: CT-STAR was feasible, with successful workflow completion in 38 out of 40 (95%) fractions. PI application to daily anatomy created OAR constraint violations in 30 out of 40 (75%) fractions. There were 8 stomach, 18 duodenum, 16 small bowel, and 11 large bowel PI OAR constraint violations. In contrast, OAR violations occurred in 2 out of 40 (5%) adaptive plans (both small bowel violations, both improved from the PI). CT-STAR also improved gross tumor volume V100 and D95 coverage in 25 out of 40 (63%) and 20 out of 40 (50%) fractions, respectively. Zero out of 40 (0%) fractions were deemed nonfeasible due to poor image quality and/or inability to delineate structures. Adaptation time per fraction was a median of 22.59 minutes (10.97-47.23). CONCLUSIONS: CT-STAR resolved OAR hard constraint violations and/or improved target coverage in silico compared with nonadapted CT-guided stereotactic body radiation therapy for the ablation of abdominal oligometastatic disease. Although limitations of this study include its small sample size and in silico design, the consistently high-quality cone beam CT images captured and comparable timing metrics to prior adaptive studies suggest that CT- STAR is a viable treatment paradigm for the ablation of abdominal oligometastatic disease. Clinical trials are in development to further evaluate CT-STAR in the clinic.


Assuntos
Radiocirurgia , Radioterapia Guiada por Imagem , Humanos , Órgãos em Risco , Estudos Prospectivos , Radiocirurgia/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...