1.
Talanta Open ; 6: 100155, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36212546

RESUMO

A severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is a cause of worldwide Coronavirus 2019 (COVID-19) disease pandemic. It is thus important to develop ultra-sensitive, rapid and easy-to-use methods for the identification of COVID-19 infected patients. Herein, an alternative electrochemical immunosensor based on poly(pyrrolepropionic acid) (pPPA) modified graphene screen-printed electrode (GSPE) was proposed for rapid COVID-19 detection. The method was based on a competitive enzyme immunoassay process utilizing horseradish peroxidase (HRP)-conjugated SARS-CoV-2 as a reporter binding molecule to compete binding with antibody against the SARS-CoV-2 receptor binding domain (SARS-CoV-2 RBD) protein. This strategy enhanced the current signal via the enzymatic reaction of HRP-conjugated SARS-CoV-2 RBD antibody on the electrode surface. The modification, immobilization, blocking, and detection processes were optimized and evaluated by amperometry. The quantitative analysis of SARS-CoV-2 was conducted based on competitive enzyme immunoassay with amperometric detection using a 3D-printed portable potentiostat for point-of-care COVID-19 diagnosis. The current measurements at -0.2 V yielded a calibration curve with a linear range of 0.01-1500 ng mL-1 (r2 = 0.983), a low detection limit of 2 pg mL-1 and a low quantification limit of 10 pg mL-1. In addition, the analyzed results of practical samples using the developed method were successfully verified with ELISA and RT-PCR. Therefore, the proposed portable electrochemical immunosensor is highly sensitive, rapid, and reliable. Thus, it is an alternative ready-to-use sensor for COVID-19 point-of-care diagnosis.

2.
Biosensors (Basel) ; 12(10)2022 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-36290989

RESUMO

As glucose biosensors play an important role in glycemic control, which can prevent the diabetic complications, the development of a glucose sensing platform is still in needed. Herein, the first proposal on the in-house fabricated paper-based screen-printed ionic liquid/graphene electrode (SPIL-GE) modified with MXene (Ti3C2Tx), prussian blue (PB), glucose oxidase (GOx), and Nafion is reported. The concentration of PB/Ti3C2Tx was optimized and the optimal detection potential of PB/Ti3C2Tx/GOx/Nafion/SPIL-GE is -0.05 V. The performance of PB/Ti3C2Tx/GOx/Nafion modified SPIL-GE was characterized by cyclic voltammetry and chronoamperometry technique. This paper-based platform integrated with nanomaterial composites were realized for glucose in the range of 0.0-15.0 mM with the correlation coefficient R2 = 0.9937. The limit of detection method and limit of quantification were 24.5 µM and 81.7 µM, respectively. In the method comparison, this PB/Ti3C2Tx/GOx/Nafion/SPIL-GE exhibits a good correlation with the reference hexokinase method. This novel glucose sensing platform can potentially be used for the good practice to enhance the sensitivity and open the opportunity to develop paper-based electroanalytical devices.


Assuntos
Técnicas Biossensoriais , Grafite , Líquidos Iônicos , Nanocompostos , Glucose Oxidase/química , Grafite/química , Hexoquinase , Enzimas Imobilizadas/química , Eletrodos , Nanocompostos/química , Técnicas Biossensoriais/métodos , Glucose , Técnicas Eletroquímicas/métodos
3.
J Colloid Interface Sci ; 583: 734-745, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-33075606

RESUMO

α-MnO2 nanofibers combined with nitrogen and sulfur co-doped reduced graphene oxide (α-MnO2/N&S-rGO) were prepared through simple hydrothermal and ball milling processes. Structural characterization results by X-ray diffraction, X-ray photoemission spectroscopy, electron microscopy and Raman spectroscopy demonstrated that α-MnO2 nanofibers with the average diameter of ~40 nm were well dispersed on N&S-rGO nanoflakes. The synthesized material was incorporated into supercapacitor (SC) electrodes and assembled with the quasi-solid-state electrolyte comprising N,N-Diethyl-N-methyl-N-(2-methoxy-ethyl)ammonium bis (trifluoromethyl-sulfonyl)amide [DEME][TFSA]/polyvinylidene fluoride-hexafluoropropylene (PVDF-co-HFP) to produce coin-cell SCs. Electrochemical performances of SCs were measured by cyclic voltammetry, galvanostatic charge-discharge, and electrochemical impedance spectroscopy. From the electrochemical data, SC using α-MnO2/N&S-rGO exhibited a good specific capacitance of 165F g-1 at 0.25 A g-1 with a wide potential window of 0-4.5 V, corresponding to a high energy density of 110 Wh kg-1 and a power density of 550 W kg-1. In addition, it exhibited good electrochemical stability with a capacitance retention of 75% after 10,000 cycles at 1 A g-1 and a low self-discharge loss. The attained energy-storage performances indicated that the α-MnO2/N&S-rGO composite could be highly promising for high-performance ionic liquid-based quasi solid-state supercapacitors.

4.
Anal Chim Acta ; 1078: 16-23, 2019 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-31358214

RESUMO

The adulteration of herbal medicines by dexamethasone or prednisolone is regarded as a serious problem in many communities. Herein, a novel platform for the separation and quantification of both target steroids in herbal medicines based on electrochemical paper-based analytical devices (ePADs) has been created. The ePAD was composed of Whatman SG81 chromatography paper, 3D-printed devices and a commercial screen-printed electrode. Whatman SG81 silica-coated paper was used for the separation of dexamethasone and prednisolone based on the difference in their partition coefficients during the flow of the mobile phase. The optimal mobile phase was composed of 60% ethyl acetate in cyclohexane and required 7 min for separation. The separated steroids on the paper were then quantified by electrochemical detection using differential pulse voltammetry, in which the 3D-printed devices facilitated the measurement. Analytical detection ranges of 10-500 µg mL-1 were obtained for both dexamethasone and prednisolone (r2 = 0.988 and 0.994, respectively). The limits of detection for dexamethasone and prednisolone were 3.59 and 11.98 µg mL-1, respectively, whereas the limits of quantification were 6.00 and 20.02 µg mL-1, respectively. The amounts of both target steroids derived from real herbal medicine samples determined by the proposed method were comparable to those obtained with assays using standard high-performance liquid chromatography. In addition, a simple evaporation step can be used to increase the concentration of the samples before analysis. These ePADs are simple, low-cost, rapid, and very promising for on-site quantitative detection.


Assuntos
Cromatografia em Papel/métodos , Dexametasona/análise , Técnicas Eletroquímicas/métodos , Preparações Farmacêuticas/análise , Preparações de Plantas/análise , Prednisolona/análise , Carbono/química , Cromatografia em Papel/instrumentação , Contaminação de Medicamentos , Técnicas Eletroquímicas/instrumentação , Eletrodos , Limite de Detecção , Papel , Impressão Tridimensional
5.
J Immunoassay Immunochem ; 39(3): 292-307, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29953329

RESUMO

ABO blood group is the most important blood type system for transfusion medicine. A paper-based analytical device (PAD) for ABO blood typing has been proposed. The device was composed of Whatman No. 113 paper, an absorbent gel pad, and a 3D-printing cassette. The 3D-printing cassette contained two circular holes for display of letters "A" and "B" on the PAD. Whole blood was dropped onto hydrophilic letters A and B on the PAD, in which the anti-A and anti-B were pre-immobilized, respectively. An absorbent gel pad was used to adsorb excess blood sample and washing solution during the washing step. The particle size of agglutinated red blood cells (RBCs) could not be eluted out of the paper by the elution solution. In contrast, non-agglutinated RBCs were washed out by means of elution solution. The devices could be used for real blood samples in a wide range of hematocrit levels, 21-59%. Unknown blood group samples (n = 500) were identified by the developed device and the results were compared with the conventional method, revealing 100% accuracy. Because of its compact size with low-cost fabrication, the portable ABO blood typing device has great potential for point-of-care testing, particularly in developing countries.