Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Head Neck ; 44(12): 2769-2778, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36114683

RESUMO

BACKGROUND: The 100 ml water swallow test (WST) is a validated swallow assessment used in head and neck cancer (HNC). We aimed to determine the level of agreement when completing the 100 ml WST via clinician-graded video-testing or patient self-testing compared to standard face-to-face assessment (FTF). METHODS: Convenience sampling from four UK centers. INCLUSION CRITERIA: patients with HNC treated with any modality prior to, or within 5 years of treatment. Participants were recruited to complete the 100 ml WST by video-testing or self-testing and compared with FTF. RESULTS: Sixty-three patients were recruited; 1 was unable to perform the task; 30 in video-testing; and 32 in self-testing. There was no difference in swallow capacity (p = 0.424) and volume (p = 0.363) for the video-testing or the self-testing swallow capacity (p = 0.777) and volume (p = 0.445). CONCLUSIONS: This study demonstrates that video-testing and self-testing are reliable methods of completing the 100 ml WST for this sample of patients with HNC.


Assuntos
Transtornos de Deglutição , Neoplasias de Cabeça e Pescoço , Humanos , Deglutição , Transtornos de Deglutição/diagnóstico , Transtornos de Deglutição/etiologia , Transtornos de Deglutição/terapia , Água , Neoplasias de Cabeça e Pescoço/diagnóstico
2.
BMJ Nutr Prev Health ; 5(2): 306-312, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36619325

RESUMO

The clinical objectives of this prospective, random, convenience series were: 1. Compare a novel fibre-optic pH test device (NGPOD) to gastric aspirate and pH testing for nasogastric tube (NGT) confirmation. 2. Determine if the new device reduces the need for chest radiography (chest X-ray, CXR). Methods: Recruitment of patients over the age of 18, requiring NGT feeding.Exclusion criteria: oesophageal gastrointestinal surgery within 3 months; all those with partial or total gastrectomy; bleeding gastric and duodenal ulcers; gastric cancer; those with oesophageal varices; those considered to be inappropriate.The index test, NGPOD, comprises a fine, flexible fibre-optic sensor passed down the NGT, then connected to an electronic device. A green light indicates pH ≤5.5, and a red light if pH is >5.5.The reference test is withdrawal of gastric aspirate and testing with universal pH indicator strips then comparison to a colour chart. Second-line testing is establishing NGT position by CXR or subjective clinical assessment (SCA) in intensive care unit (ICU). Results: The analysed data set contained 174 subjects who had undergone 496 tests, 96 initial and 400 repeat NGT checks.For all patients, NGPOD can reduce the need for CXR or SCA by 21.2%.In ICU, NGPOD can reduce the need for CXR or SCA by 24.5%.When performing initial tests, immediately after tube placement, NGPOD can reduce the need for CXR or SCA in 61% of patients.With repeat testing, NGPOD can reduce the need to progress to CXR or SCA in 16% of tests. Conclusions: The objective, yes-no result delivered by NGPOD, eliminates the subjective reading of a pH strip colour change, reducing the subjective element. The index test has the opportunity to reduce risk, improve safety and decrease the numbers of patients requiring X-ray. It, therefore, has the potential to reduce never events associated with NGT misplacement.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...