Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
1.
Sci Rep ; 14(1): 663, 2024 01 05.
Artigo em Inglês | MEDLINE | ID: mdl-38182726

RESUMO

In clinical practice, diagnosis of suspected carious lesions is verified by using conventional dental radiography (DR), including panoramic radiography (OPT), bitewing imaging, and dental X-ray. The aim of this study was to evaluate the use of magnetic resonance imaging (MRI) for caries visualization. Fourteen patients with clinically suspected carious lesions, verified by standardized dental examination including DR and OPT, were imaged with 3D isotropic T2-weighted STIR (short tau inversion recovery) and T1 FFE Black bone sequences. Intensities of dental caries, hard tissue and pulp were measured and calculated as aSNR (apparent signal to noise ratio) and aHTMCNR (apparent hard tissue to muscle contrast to noise ratio) in both sequences. Imaging findings were then correlated to clinical examination results. In STIR as well as in T1 FFE black bone images, aSNR and aHTMCNR was significantly higher in carious lesions than in healthy hard tissue (p < 0.001). Using water-sensitive STIR sequence allowed for detecting significantly lower aSNR and aHTMCNR in carious teeth compared to healthy teeth (p = 0.01). The use of MRI for the detection of caries is a promising imaging technique that may complement clinical exams and traditional imaging.


Assuntos
Cárie Dentária , Humanos , Cárie Dentária/diagnóstico por imagem , Suscetibilidade à Cárie Dentária , Imageamento por Ressonância Magnética , Inversão Cromossômica , Nível de Saúde
2.
Innov Surg Sci ; 8(3): 137-148, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38077486

RESUMO

In mandibular reconstruction, computer-assisted procedures, including virtual surgical planning (VSP) and additive manufacturing (AM), have become an integral part of routine clinical practice. Especially complex cases with extensive defects after ablative tumor surgery benefit from a computer-assisted approach. Various CAD/CAM-manufactured tools such as surgical guides (guides for osteotomy, resection and predrilling) support the transition from virtual planning to surgery. Patient-specific implants (PSIs) are of particular value as they facilitate both osteosynthesis and the positioning of bone elements. Computer-based approaches may be associated with higher accuracy, efficiency, and superior patient outcomes. However, certain limitations should be considered, such as additional costs or restricted availability. In the future, automation of the planning process and augmented reality techniques, as well as MRI as a non-ionizing imaging modality, have the potential to further improve the digital workflow.

3.
Eur Radiol ; 2023 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-37855855

RESUMO

OBJECTIVES: T2 STIR MRI sequences can detect preclinical changes associated with periodontal inflammation, i.e. intraosseous edema in the tooth-supporting bone. In this study, we assessed whether MRI can be used for monitoring periodontal disease. MATERIAL AND METHODS: In a prospective cohort study, we examined 35 patients with periodontitis between 10/2018 and 04/2019 by using 3D isotropic T2-weighted short tau inversion recovery (STIR) and Fast Field Echo T1-weighted Black bone sequences. All patients received standardized clinical exams before and three months after non-surgical periodontal therapy. Bone marrow edema extent was quantified in the STIR sequence at 922 sites before and after treatment. Results were compared with standard clinical findings. Non-parametric statistical analysis was performed. RESULTS: Non-surgical periodontal treatment caused significant improvement in mean probing depth (p < 0.001) and frequency of bleeding on probing (p < 0.001). The mean depth of osseous edema per site was reduced from a median [IQR] of 2 [1, 3] mm at baseline to 1 [0, 3] mm, (p < 0.001). Periodontal treatment reduced the frequency of sites with edema from 35 to 24% (p < 0.01). CONCLUSION: The decrease of periodontal bone marrow edema, as observed with T2 STIR MR imaging, is indicative of successful periodontal healing. CLINICAL RELEVANCE STATEMENT: T2 STIR hyperintense bone marrow edema in the periodontal bone decreases after treatment and can therefore be used to evaluate treatment success. Furthermore, MRI reveals new options to depict hidden aspects of periodontitis. KEY POINTS: • T2 STIR hyperintense periodontal intraosseous edema was prospectively investigated in 35 patients with periodontitis before and after treatment and compared to clinical outcomes. • The frequency of affected sites was reduced from 35 to 24% (p < 0.001), and mean edema depth was reduced from a median [IQR] of 2 [1, 3] mm at baseline to 1 [0, 3] mm 3 months after treatment. (p < 0.001). • T2 STIR sequences can be used to monitor the posttreatment course of periodontitis.

5.
Clin Oral Investig ; 27(9): 5403-5412, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37464086

RESUMO

OBJECTIVES: To detect and evaluate early signs of apical periodontitis using MRI based on a 3D short-tau-inversion-recovery (STIR) sequence compared to conventional panoramic radiography (OPT) and periapical radiographs in patients with apical periodontitis. MATERIALS AND METHODS: Patients with clinical evidence of periodontal disease were enrolled prospectively and received OPT as well as MRI of the viscerocranium including a 3D-STIR sequence. The MRI sequences were assessed for the occurrence and extent of bone changes associated with apical periodontitis including bone edema, periradicular cysts, and dental granulomas. OPTs and intraoral periapical radiographs, if available, were assessed for corresponding periapical radiolucencies using the periapical index (PAI). RESULTS: In total, 232 teeth of 37 patients (mean age 62±13.9 years, 18 women) were assessed. In 69 cases reactive bone edema was detected on MRI with corresponding radiolucency according to OPT. In 105 cases edema was detected without corresponding radiolucency on OPT. The overall extent of edema measured on MRI was significantly larger compared to the radiolucency on OPT (mean: STIR 2.4±1.4 mm, dental radiograph 1.3±1.2 mm, OPT 0.8±1.1 mm, P=0.01). The overall PAI score was significantly higher on MRI compared to OPT (mean PAI: STIR 1.9±0.7, dental radiograph 1.3±0.5, OPT 1.2±0.7, P=0.02). CONCLUSION: Early detection and assessment of bone changes of apical periodontitis using MRI was feasible while the extent of bone edema measured on MRI exceeded the radiolucencies measured on OPT. CLINICAL RELEVANCE: In clinical routine, dental MRI might be useful for early detection and assessment of apical periodontitis before irreversible bone loss is detected on conventional panoramic and intraoral periapical radiographs.


Assuntos
Periodontite Periapical , Dente não Vital , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Tratamento do Canal Radicular , Periodontite Periapical/complicações , Radiografia , Imageamento por Ressonância Magnética , Dente não Vital/diagnóstico por imagem
6.
Clin Oral Investig ; 27(9): 5063-5072, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37382718

RESUMO

OBJECTIVE: To determine the accuracy of maxillary positioning using computer-designed and manufactured occlusal splints or patient-specific implants in orthognathic surgery. MATERIAL AND METHODS: A retrospective analysis of 28 patients that underwent virtually planned orthognathic surgery with maxillary Le Fort I osteotomy either using VSP-generated splints (n = 13) or patient-specific implants (PSI) (n = 15) was conducted. The accuracy and surgical outcome of both techniques were compared by superimposing preoperative surgical planning with postoperative CT scans and measurement of translational and rotational deviation for each patient. RESULTS: The 3D global geometric deviation between the planned position and the postoperative outcome was 0.60 mm (95%-CI 0.46-0.74, range 0.32-1.11 mm) for patients with PSI and 0.86 mm (95%-CI 0.44-1.28, range 0.09-2.60 mm) for patients with surgical splints. Postoperative differences for absolute and signed single linear deviations between planned and postoperative position were a little higher regarding the x-axis and pitch but lower regarding the y- and z-axis as well as yaw and roll for PSI compared to surgical splints. There were no significant differences regarding global geometric deviation, absolute and signed linear deviations in the x-, y-, and z-axis, and rotations (yaw, pitch, and roll) between both groups. CONCLUSIONS: Regarding accuracy for positioning of maxillary segments after Le Fort I osteotomy in orthognathic surgery patient-specific implants and surgical splints provide equivalent high accuracy. CLINICAL RELEVANCE: Patient-specific implants for maxillary positioning and fixation facilitate the concept of splintless orthognathic surgery and can be reliably used in clinical routines.


Assuntos
Implantes Dentários , Cirurgia Ortognática , Procedimentos Cirúrgicos Ortognáticos , Cirurgia Assistida por Computador , Humanos , Placas Oclusais , Procedimentos Cirúrgicos Ortognáticos/métodos , Estudos Retrospectivos , Cirurgia Assistida por Computador/métodos , Maxila/cirurgia , Computadores , Imageamento Tridimensional/métodos , Osteotomia de Le Fort/métodos
7.
Medicina (Kaunas) ; 59(5)2023 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-37241232

RESUMO

Background and Objectives: Antiresorptive drugs are widely used in osteology and oncology. An important adverse effect of these drugs is medication-induced osteonecrosis of the jaw (MRONJ). There is scientific uncertainty about the underlying pathomechanism of MRONJ. A promising theory suspects infectious stimuli and local acidification with adverse effects on osteoclastic activity as crucial steps of MRONJ etiology. Clinical evidence showing a direct association between MRONJ and oral infections, such as periodontitis, without preceding surgical interventions is limited. Large animal models investigating the relationship between periodontitis and MRONJ have not been implemented. It is unclear whether the presence of infectious processes without surgical manipulation can trigger MRONJ. The following research question was formulated: is there a link between chronic oral infectious processes (periodontitis) and the occurrence of MRONJ in the absence of oral surgical procedures? Materials and Methods: A minipig large animal model for bisphosphonate-related ONJ (BRONJ) using 16 Göttingen minipigs divided into 2 groups (intervention/control) was designed and implemented. The intervention group included animals receiving i.v. bisphosphonates (zoledronate, n = 8, 0.05 mg/kg/week: ZOL group). The control group received no antiresorptive drug (n = 8: NON-ZOL group). Periodontitis lesions were induced by established procedures after 3 months of pretreatment (for the maxilla: the creation of an artificial gingival crevice and placement of a periodontal silk suture; for the mandible: the placement of a periodontal silk suture only). The outcomes were evaluated clinically and radiologically for 3 months postoperatively. After euthanasia a detailed histological evaluation was performed. Results: Periodontitis lesions could be induced successfully in all animals (both ZOL and NON-ZOL animals). MRONJ lesions of various stages developed around all periodontitis induction sites in the ZOL animals. The presence of MRONJ and periodontitis was proven clinically, radiologically and histologically. Conclusions: The results of this study provide further evidence that the infectious processes without prior dentoalveolar surgical interventions can trigger MRONJ. Therefore, iatrogenic disruption of the oral mucosa cannot be the decisive step in the pathogenesis of MRONJ.


Assuntos
Osteonecrose da Arcada Osseodentária Associada a Difosfonatos , Conservadores da Densidade Óssea , Periodontite , Animais , Suínos , Osteonecrose da Arcada Osseodentária Associada a Difosfonatos/diagnóstico por imagem , Osteonecrose da Arcada Osseodentária Associada a Difosfonatos/etiologia , Osteonecrose da Arcada Osseodentária Associada a Difosfonatos/tratamento farmacológico , Porco Miniatura , Difosfonatos/efeitos adversos , Ácido Zoledrônico/efeitos adversos , Conservadores da Densidade Óssea/efeitos adversos , Modelos Animais de Doenças , Periodontite/etiologia , Seda
8.
Cancers (Basel) ; 14(17)2022 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-36077775

RESUMO

The impact of neck involvement and occult metastasis (OM) in patients with oral squamous cell carcinoma (OSCC) favors an elective neck dissection. However, there are barely any existing data on survival for patients with OM compared with patients with positive lymph nodes detected preoperatively. This study aims to compare survival curves of patients suffering from lymph nodal metastases in a preoperatively N+ neck with those suffering from OM. In addition, clinical characteristics of the primary tumor were analyzed to predict occult nodal disease. This retrospective cohort study includes patients with an OSCC treated surgically with R0 resection with or without adjuvant chemoradiotherapy between 2010 and 2016. Minimum follow-up was 60 months. Kaplan-Meier analysis was used to compare the survival between patients with and without occult metastases and patients with N+ neck to those with occult metastases. Logistic regression was used to detect potential risk factors for occult metastases. The patient cohort consisted of 226 patients. Occult metastases occurred in 16 of 226 patients. In 53 of 226 patients, neck lymph nodes were described as suspect on CT imaging but had a pN0 neck. Higher tumor grading increased the chance of occurrence of occult metastasis 2.7-fold (OR = 2.68, 95% CI: 1.07-6.7). After 12, 24, 48 and 60 months, 82.3%, 73.8%, 69% and 67% of the N0 patients, respectively, were progression free. In the group with OM occurrence, for the same periods 66.6%, 50%, 33.3% and 33.3% of the patients, respectively, were free of disease. For the same periods, respectively, 81%, 63%, 47% and 43% of the patients in the N+ group but without OM remained disease free. The predictors for progression-free survival were a positive N status (HR = 1.44, 95% CI: 1.08-1.93) and the occurrence of OM (HR = 2.33, 95% CI: 1.17-4.64). The presence of occult metastasis could lead to decreased survival and could be a burdening factor requiring treatment escalation and a more aggressive follow-up than nodal disease detected in the preoperative diagnostic imaging.

9.
Head Face Med ; 18(1): 21, 2022 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-35768853

RESUMO

BACKGROUND: The aim of the present study was to examine the cytostatic effects of cold atmospheric plasma (CAP) on different head and neck squamous carcinoma (HNSCC) cell lines either in isolation or in combination with low dose cisplatin. The effect of CAP treatment was investigated by using three different HNSCC cell lines (chemo-resistant Cal 27, chemo-sensitive FaDu and OSC 19). MATERIALS AND METHOD: Cell lines were exposed to CAP treatment for 30, 60, 90, 120 and 180 s (s). Cisplatin was added concurrently (cc) or 24 h after CAP application (cs). Cell viability, DNA damage and apoptosis was evaluated by dye exclusion, MTT, alkaline microgel electrophoresis assay and Annexin V-Fit-C/PI respectively. RESULTS: In all cell lines, 120 s of CAP exposure resulted in a significant reduction of cell viability. DNA damage significantly increased after 60 s. Combined treatment of cells with CAP and low dose cisplatin showed additive effects. A possible sensitivity to cisplatin could be restored in Cal 27 cells by CAP application. CONCLUSION: CAP shows strong cytostatic effects in HNSCC cell lines that can be increased by concurrent cisplatin treatment, suggesting that CAP may enhance the therapeutic efficacy of low dose cisplatin.


Assuntos
Carcinoma de Células Escamosas , Citostáticos , Neoplasias de Cabeça e Pescoço , Gases em Plasma , Carcinoma de Células Escamosas/tratamento farmacológico , Carcinoma de Células Escamosas/genética , Linhagem Celular Tumoral , Cisplatino/farmacologia , Cisplatino/uso terapêutico , Citostáticos/uso terapêutico , Neoplasias de Cabeça e Pescoço/tratamento farmacológico , Humanos , Gases em Plasma/farmacologia , Gases em Plasma/uso terapêutico , Carcinoma de Células Escamosas de Cabeça e Pescoço/tratamento farmacológico
11.
Laryngoscope Investig Otolaryngol ; 7(2): 369-379, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35434332

RESUMO

Objective: To evaluate the feasibility and accuracy of implementing three-dimensional virtual surgical planning (VSP) and subsequent transfer by additive manufactured tools in the secondary reconstruction of residual post-traumatic deformities in the midface. Methods: Patients after secondary reconstruction of post-traumatic midfacial deformities were included in this case series. The metrical deviation between the virtually planned and postoperative position of patient-specific implants (PSI) and bone segments was measured at corresponding reference points. Further information collected included demographic data, post-traumatic symptoms, and type of transfer tools. Results: Eight consecutive patients were enrolled in the study. In five patients, VSP with subsequent manufacturing of combined predrilling/osteotomy guides and PSI was performed. In three patients, osteotomy guides, repositioning guides, and individually prebent plates were used following VSP. The median distances between the virtually planned and the postoperative position of the PSI were 2.01 mm (n = 18) compared to a median distance concerning the bone segments of 3.05 mm (n = 12). In patients where PSI were used, the median displacement of the bone segments was lower (n = 7, median 2.77 mm) than in the group with prebent plates (n = 5, 3.28 mm). Conclusion: This study demonstrated the feasibility of VSP and transfer by additive manufactured tools for the secondary reconstruction of complex residual post-traumatic deformities in the midface. However, the median deviations observed in this case series were unexpectedly high. The use of navigational systems may further improve the level of accuracy.

12.
J Oral Pathol Med ; 51(5): 421-428, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35430758

RESUMO

BACKGROUND: The objective was to assess the expression patterns of the cancer testis antigen PRAME, NY-ESO1, and SSX2 in oral squamous cell carcinoma (OSSC) and to correlate the expression with clinical and histopathological parameters including progression-free survival analysis. METHODS: The study variables of this retrospective cohort study (n = 83) included demographic data, histopathological data, and information on progression-free survival. PRAME expression patterns were rated based on immunohistochemistry on tissue microarrays (TMA). The survival rate was assessed by Kaplan-Meier method and Cox regression model. The primary predictor variable was defined as the expression of PRAME and the outcome variable was progression-free survival. RESULTS: Analysis of progression-free survival using Kaplan-Meier method showed that patients with positive expression of PRAME had lower probabilities of progression-free survival (p < 0.001). According to the Cox regression model, the level of PRAME expression had a considerable and significant independent influence on progression-free survival (positive PRAME expression increasing the hazards for a negative outcome by 285% in our sample; HR = 3.85, 95% CI: 1.45-10.2, p = 0.007). The expression of SSX2 (n = 1) and NY-ESO-1 (n = 5) in our samples was rare. CONCLUSION: PRAME is expressed in OSCC and appears to be a suitable marker of progression-free survival, correlates with severe course, and may allow identification of high-risk patients with aggressive progression.


Assuntos
Carcinoma de Células Escamosas , Neoplasias de Cabeça e Pescoço , Neoplasias Bucais , Antígenos de Neoplasias , Biomarcadores Tumorais/metabolismo , Intervalo Livre de Doença , Humanos , Masculino , Prognóstico , Estudos Retrospectivos , Carcinoma de Células Escamosas de Cabeça e Pescoço , Testículo/química , Testículo/metabolismo
13.
Clin Oral Investig ; 26(3): 2839-2852, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34812959

RESUMO

OBJECTIVES: While risk factors of bisphosphonate (BP) associated osteonecrosis of the jaw have been properly analyzed, studies focusing on risk factors associated with denosumab (DNO) are sparse. The purpose of this study was to identify risk factors influencing the onset of medication-related osteonecrosis of the jaw (MRONJ) in patients receiving antiresorptive treatment (ART) with DNO by comparing patients suffering from MRONJ and patients without MRONJ. Multiple variables were evaluated including the impact of a previous BP intake. MATERIALS AND METHODS: A retrospective single-center cohort study with patients receiving DNO was conducted. One-hundred twenty-eight patients were included and divided into three groups: I (control, n = 40) receiving DNO with absence of MRONJ; group II (Test 1, n = 46), receiving DNO with presence of MRONJ; and group III (Test 2, n = 42) sequentially receiving BP and DNO with presence of MRONJ. Patients' medical history, focusing on the identification of MRONJ risk factors, was collected and evaluated. Parameters were sex, age, smoking habit, alcohol consumption, underlying disease (cancer type, osteoporosis), internal diseases, additional chemo/hormonal therapy, oral inflammation, and trauma. RESULTS: The following risk factors were identified to increase MRONJ onset significantly in patients treated with DNO: chemo/hormonal therapy (p = 0.02), DNO dosage (p < 0.01), breast cancer (p = 0.03), intake of corticosteroids (p = 0.04), hypertension (p = 0.02), diabetes mellitus (p = 0.04), periodontal disease (p = 0.03), apical ostitis (p = 0.02), and denture use (p = 0.02). A medication switch did not affect MRONJ development (p = 0.86). CONCLUSIONS: Malignant diseases, additional chemotherapy, DNO dosage, and oral inflammations as well as diabetes mellitus and hypertension influence MRONJ onset in patients treated with DNO significantly. CLINICAL RELEVANCE: Patients receiving ART with DNO featuring aforementioned risk factors have a higher risk of MRONJ onset. These patients need a sound and regular prophylaxis in order to prevent the onset of MRONJ under DNO treatment.


Assuntos
Osteonecrose da Arcada Osseodentária Associada a Difosfonatos , Conservadores da Densidade Óssea , Denosumab , Osteonecrose da Arcada Osseodentária Associada a Difosfonatos/prevenção & controle , Conservadores da Densidade Óssea/efeitos adversos , Denosumab/efeitos adversos , Humanos , Estudos Retrospectivos , Fatores de Risco
14.
J Craniomaxillofac Surg ; 50(3): 281-288, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34887169

RESUMO

The purpose of this study was to determine the expression patterns of specific desmosomal cadherins (desmogleins [DSG] 1/2/3) in oral squamous cell carcinoma (OSCC), and to examine possible associations with clinicopathological parameters and recurrence rates. Changes in desmosomal cadherin assembly may promote tumor metastasis formation. Patients with surgically treated OSCC with 36-60 months of follow-up (median 46 months) qualified for inclusion in this retrospective cohort study. Demographic, clinical and pathohistological data were collected. DSG-1/2/3 expression patterns were determined by an immunohistochemical approach on tissue microarrays. Descriptive and inferential statistics and survival analyses were computed (p ≤ 0.05). The study sample consisted of 88 patients (female: 38; male: 50; average age: 63.02 ± 17.5 years). DSG-3 overexpression was detected in 45 of 88 specimens. The expression rates for DSG-1 (28/88) and DSG-2 (14/88) were low and inconspicuous. DSG-3 overexpression was significantly associated with poor histologic differentiation (G3, p = 0.001), the presence of cervical node metastasis at primary diagnosis (N+ status, p = 0.001) and early recurrence (p = 0.001). Due to its possible relevance for lymph node metastasis formation and early OSCC recurrence, determination of DSG-3 expression in OSCC specimens may be a valuable tool for treatment planning and post-therapeutic risk assessment.


Assuntos
Carcinoma de Células Escamosas , Neoplasias de Cabeça e Pescoço , Neoplasias Bucais , Idoso , Idoso de 80 Anos ou mais , Carcinoma de Células Escamosas/patologia , Feminino , Humanos , Imuno-Histoquímica , Masculino , Pessoa de Meia-Idade , Neoplasias Bucais/patologia , Prognóstico , Estudos Retrospectivos , Carcinoma de Células Escamosas de Cabeça e Pescoço
15.
Cancers (Basel) ; 13(16)2021 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-34439279

RESUMO

PURPOSE: To investigate the expression pattern of CD36 in a patient population with oral squamous cell carcinoma (OSCC) and to correlate CD36 expression with clinical and histopathological parameters. The hypothesis was that CD36 expression correlates with the occurrence of lymph node metastasis. METHODS: To address the study objectives, a retrospective cohort study was conducted. Study variables included demographic, histopathological and survival data. CD36 expression patterns were assessed by immunohistochemistry on tissue microarrays (TMA). Logistic regression analysis, survival analysis and Cox proportional hazards model were performed. RESULTS: High CD36 expression correlated significantly with a higher T-status, grading and occurrence of lymph node metastasis. The logistic regression with binary N status as a dependent variable showed that high CD36 expression increased the chance for lymph node metastasis 45-fold (OR = 44.7, 95% CI: 10.0-316). Patients with high CD36 expression had lower probabilities of progression-free survival. CD36 had a small and non-significant independent influence on progression-free survival. CONCLUSIONS: CD36 is expressed in OSCC and correlates with tumor grading, T-status, and especially the occurrence of lymph node metastasis. CD36 may be useful for risk stratification regarding lymph node metastasis in OSCC.

16.
Int J Oral Maxillofac Implants ; 36(4): 762-770, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34411218

RESUMO

PURPOSE: The aim of this study was to investigate the influence of different clinical parameters on the primary stability of a variable thread tapered implant system with a focus on surgical undersizing protocols. MATERIALS AND METHODS: This retrospective study evaluated patients who received NobelActive implants in a single institution. The relationship between the independent variables, bone quality, implant diameter, implant length, implantation time, region of the jaw, and surgical undersizing protocol, and the dependent variable, maximum insertion torque, was investigated. Statistical analysis was conducted using analysis of variance (ANOVA) and multiple linear regression. RESULTS: A total of 1,292 implants placed in 574 fully or partially edentulous patients were evaluated. For the total sample size, without further differentiation between bone qualities, statistically significantly higher primary stability values were shown for an 8% to 9% undersized group (50.33 ± 17.16 Ncm), compared with a 16% undersized group (41.88 ± 17.63 Ncm), a 20% undersized group (33.65 ± 15.78 Ncm), a 26% to 28% undersized group (34.53 ± 15.49 Ncm), and a 35% to 44% undersized group (32.78 ± 18.80 Ncm). No statistical differences were found for undersizing protocols in bone quality 4. Bone quality had the highest influence on primary stability (Welch-Test F(3, 65.57) = 119.48, P < .001, η2 = .20). Contrary to the other investigated independent variables, no statistically significant differences in primary stability were found for the different implantation times. CONCLUSION: Undersizing protocols exceeding 8% to 9% do not seem to enhance primary stability values. Further studies are needed to investigate the biologic consequences of undersizing, including the impact of implant design characteristics.


Assuntos
Implantes Dentários , Implantação Dentária Endóssea , Planejamento de Prótese Dentária , Humanos , Estudos Retrospectivos , Torque
17.
Comput Biol Med ; 137: 104791, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34464850

RESUMO

BACKGROUND: To assess the accuracy with which CAD/CAM-fabricated patient-specific titanium implants (PSI) are positioned for inferior and/or medial orbital wall reconstruction without the use of intraoperative navigation. METHODS: Patients who underwent a primary reconstruction of the orbital walls with PSI due to fractures were enrolled in this retrospective cohort analysis. The primary outcome variables were the mean surface distances (MSD) between virtually planned and postoperative PSI position and single linear deviations in the x-, y- and z-axis at corresponding reference points. Secondary outcome variables included demographic data, classification of orbital wall defects and clinical outcomes. RESULTS: A total of 33 PSI (orbital floor n = 22; medial wall, n = 11) were examined in 27 patients. MSD was on a comparable level for the orbital floor and medial wall (median 0.39 mm, range 0.22-1.53 mm vs. median 0.42 mm, range 0.21-0.98 mm; p = 0.56). Single linear deviations were lower for reconstructions of the orbital floor compared to the medial wall (median 0.45 vs. 0.79 mm; p < 0.05). There was no association between the occurrence of diplopia and the accuracy level (p = 0.418). CONCLUSIONS: Free-hand positioning of PSI reaches a clinically appropriate level of accuracy, limiting the necessity of navigational systems to selected cases.


Assuntos
Fraturas Orbitárias , Procedimentos de Cirurgia Plástica , Humanos , Órbita/cirurgia , Fraturas Orbitárias/diagnóstico por imagem , Fraturas Orbitárias/cirurgia , Próteses e Implantes , Estudos Retrospectivos
18.
Clin Implant Dent Relat Res ; 23(5): 779-788, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34318580

RESUMO

BACKGROUND: Providing accurate 3-dimensional virtual bone surface models is a prerequisite for virtual surgical planning and additive manufacturing in craniomaxillofacial surgery. For this purpose, magnetic resonance imaging (MRI) may be a radiation-free alternative to computed tomography (CT) and cone beam computed tomography (CBCT). PURPOSE: The aim of this study was to assess the geometric accuracy of 3-dimensional T1-weighted MRI-derived virtual bone surface models of the mandible in comparison to CT and CBCT. MATERIALS AND METHODS: Specimens of the mandible from porcine cadavers were scanned with (1) a 3-dimensional T1-weighted MRI sequence (0.6 mm isotropic voxel) optimized for bone imaging, (2) CT, and (3) CBCT. Cortical mandibular structures (n = 10) were segmented using semiautomated and manual techniques. Imaging-based virtual 3-dimensional models were aligned with a high-resolution optical 3-dimensional surface scan of the dissected bone (=ground truth) and global geometric deviations were calculated (mean surface distance [MSD]/root-mean-square distance [RMSD]). Agreement between the imaging modalities was assessed by equivalence testing and Bland-Altman analysis. RESULTS: Intra- and inter-rater agreement was on a high level for all modalities. Global geometric deviations (MSD/RMSD) between optical scans and imaging modalities were 0.225 ± 0.020 mm/0.345 ± 0.074 mm for CT, 0.280 ± 0.067 mm/0.371 ± 0.074 mm for MRI, and 0.352 ± 0.076 mm/0.454 ± 0.071 mm for CBCT. All imaging modalities were statistically equivalent within an equivalence margin of ±0.3 mm, and Bland-Altman analysis indicated high agreement as well. CONCLUSIONS: The results of this study indicate that the accuracy and reliability of MRI-derived virtual 3-dimensional bone surface models is equal to CT and CBCT. MRI may be considered as a reliable alternative to CT and CBCT in computer-assisted craniomaxillofacial surgery.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Mandíbula , Animais , Cadáver , Imageamento por Ressonância Magnética , Mandíbula/diagnóstico por imagem , Reprodutibilidade dos Testes , Suínos
19.
J Craniomaxillofac Surg ; 49(7): 598-612, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34020871

RESUMO

OBJECTIVE: This retrospective study evaluates the occurrence and frequency of different fracture patterns in a series of computed tomography (CT) scans in terms of the AOCMF Trauma Classification (TC) orbit module and correlates the assigned defects with measurements of the fracture area in order to get an approximate guideline for fracture size predictions on the basis of the classification. MATERIAL AND METHODS: CT scans of patients with orbital floor fractures were evaluated using the AOCMFTC to determine the topographical subregions. The coding consisted of: W = orbital wall, 1 = anterior orbit, 2 = midorbit, i = inferior, m = medial. The 3-dimensional surface area size of the fractures was quantified by the "defect body" method (Brainlab, Munich, Germany). The fracture area size and its confidence and prediction interval within each topographical subregion was estimated by regression analysis. RESULTS: A total of 137 CT scans exhibited 145 orbital floor fractures, which were combined with 34 medial orbital wall fractures in 31 patients. The floor fractures - W1(i)2(i) (n = 86) and W1(i) (n = 19) were the most frequent patterns. Combined floor and medial wall fractures most frequently corresponded to the pattern W1 (im)2 (im) (n = 15) ahead of W1 (im) 2(i) (n = 10). The surface area size ranged from 0.11 cm2 to 6.09 cm2 for orbital floor and from 0.29 cm2 to 5.43 cm2 for medial wall fractures. The prediction values of the mean fracture area size within the subregions were computed as follows: W1(i) = 2.25 cm2, W2(i) = 1.64 cm2, W1(i)2(i) = 3.10 cm2, W1(m) = 1.36 cm2, W2(m) = 1.65 cm2, W1(m)2(m) = 2.98 cm2, W1 (im) = 3.35 cm2, W1 (im) 2(i) = 4.63 cm2, W1 (im)2(m) = 4.06 cm2 and W1 (im)2 (im) = 7.16 cm2. CONCLUSION: The AOCMFTC orbital module offers a suitable framework for topographical allocation of fracture patterns inside the infero-medial orbital cavity. The involvement of the subregions is of predictive value providing estimations of the mean 3-D fracture area size.


Assuntos
Órbita , Fraturas Orbitárias , Alemanha , Humanos , Órbita/diagnóstico por imagem , Fraturas Orbitárias/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
20.
Sensors (Basel) ; 21(7)2021 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-33805353

RESUMO

Due to higher automation and predictive maintenance, it becomes more and more important to acquire as many data as possible during industrial processes. However, many scenarios require remote sensing since either moving parts would result in wear and tear of cables or harsh environments prevent a wired connection. In the last few years, resonant surface acoustic wave (SAW) sensors have promised the possibility to be interrogable wirelessly which showed very good results in first studies. Therefore, the sensor's resonance frequency shifts due to a changed measurand and thus has to be determined. However, up to now frequency reader systems showed several drawbacks like high costs or insufficient accuracy that blocked the way for a widespread usage of this approach in the mass market. Hence, this article presents a miniaturized and low cost six-port based frequency reader for SAW resonators in the 2.45 GHz ISM band that does not require an external calculation unit. It is shown that it can be either used to evaluate the scenario or measure the frequency directly with an amplitude or phase measurement, respectively. The performance of the system, including the hardware and embedded software, is finally shown by wired and contactless torque measurements.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...